Installation
Instructions
TM
2385.R SERIES
2385.W SERIES
LAVATORY FAUCETS
POP-UP DRAIN
Thank you for selecting American-Standard...the benchmark
of fine quality for over 100 years.
To ensure that your installation proceeds smoothly--please
read these instructions carefully before you begin.
STOPPER
DRAIN
FLANGE
FLANGE
GASKET
GASKET
WASHER
EXTENSION
THUMBSCREW
SET SCREW
CARTRIDGE
SCREWS
Certified to comply with ANSI A112.18.1M
U.S. PATENT NO. 4,294,289;
HANDLE
HANDLE
BUSHING
CAP
HOT LIMIT
STOP
CAP
RETAINER
78523C
NUT
DRAIN
BODY
PIVOT
ROD
Printed in U.S.A.
1
CAUTION
FAUCET INSTALLATION
Put U-CHANNEL, SPACERS, if necessary and NUTS
onto BOLTS.
Place PUTTY PLATE on SINK. Push faucet supplies
and studs through deck holes.
Insert POP-UP ROD to assure proper clearance when
faucet is assembled to the sink.
Position FAUCET on SINK.
Tighten HEXNUTS.
Turn off hot and cold water
supplies before beginning.
CLIP
1/2 GPM
FLOW DEVICE
AERATOR
KEY
UNDERBODY
SCREW
SUPPLY
NUT
POP-UP
ROD
BOLT
SEALS
U- CHANNEL
PUTTY
PLATE
CARTRIDGE
P0P-UP
ROD
U- CHANNEL
SPACER
HEX NUT
PUTTY
PLATE
Printed
on
Recycled
Paper
HEX NUT
SINK
CONNECT SUPPLIES
2
Carefully bend copper supplies to meet water supply lines using
the palms of the hands to avoid kinking.
Connect HOT water supply line to LEFT tube, and COLD water
supply line to RIGHT tube using appropriate connectors.
OR
3
INSTALL POP-UP DRAIN
FLANGE
Push DRAIN BODY down into trap.
Thread LOCKNUT, WASHER and GASKET onto
DRAIN BODY.
Feed DRAIN BODY up through SINK. Place FLANGE
GASKET over BODY and thread FLANGE FULLY
onto BODY.
Tighten LOCKNUT firmly, keeping the PIVOT ROD
pointed towards the back of the SINK.
Drop STOPPER into DRAIN BODY.
Position EXTENSION ROD onto POP-UP ROD and
tighten THUMBSCREW.
TEST INSTALLED FAUCET
4
Move handle down into "off" position and remove AERATOR.
For vandal-resistant FLOW DEVICE, insert KEY teeth into
slots near outlet and turn.
HOT LIMIT STOP
5
SINK
LOCKNUT
DRAIN
BODY
By restricting handle rotation and limiting the amount of hot
water allowed to mix with the cold, the HOT LIMIT SAFETY
STOP reduces risk of accidental scalding. To set the maximum
hot water temperature of your RELIANT faucets, all you need
to do is adjust the setting on the HOT LIMIT SAFETY STOP.
STOPPER
FLANGE
GASKET
GASKET
WASHER
PIVOT
ROD
TRAP
Turn on water supplies and check connections for leaks.
Operate handle up and down, left and right to flush water lines
thoroughly.
Move handle down to "off" position and replace AERATOR or FLOW
DEVICE.
PRY UPWARD TO UNLOCK
AND ROTATE COUNTER-
CLOCKWISE ONE CLICK
Remove one end of CLIP from PIVOT ROD by squeezing
ends together while sliding.
Insert PIVOT ROD into second or third hole in EXTENSION
and reassemble CLIP. (EXTENSION may need to be bent.)
Adjust STOPPER height by repositioning EXTENSION and
tightening THUMBSCREW.
POP-UP ROD
THUMBSCREW
DRAIN
BODY
TRAP
EXTENSION
ROD
FRONT
EXTENSION
ROD
"B"
PRY UPWARD TO UNLOCK
AND ROTATE CLOCKWISE
CLIP
"A"
PIVOT
ROD
CLIP
FRONT
Remove HANDLE, CAP and HOT LIMIT STOP. Follow "A" or "B"
to adjust maximum discharge temperature.
SERVICE
6
AERATOR may accumulate dirt causing distorted and reduced
water flow. Remove AERATOR. Clean AERATOR and FLOW
RESTRICTOR. Replace AERATOR.
If faucet drips, operate handle several times from "off" to "on".
Do not apply excessive force.
Clogged CARTRIDGE inlets may cause reduced flow in "full
on" hot or cold. To clean inlets, first turn off water supply,
then:
Remove HANDLE, CAP, HOT LIMIT STOP and CARTRIDGE.
Clean inlets and MANIFOLD.
Reassemble CARTRIDGE, alternately tightening screws. Replace
HOT LIMIT STOP , CAP and HANDLE. Check flow.
ADJUSTMENT WHEN
WATER IS TOO HOT
HANDLE
SET SCREW
HANDLE
BUSHING
CAP
HOT LIMIT
STOP
CARTRIDGE
SCREWS
CAP
RETAINER
For toll-free information and answers to your questions, call:
Weekdays 8:00 a.m. to 4:00 p.m. Eastern Time
Product names listed herein are trademarks of American Standard Inc.
C
American Standard Inc. 1993
ADJUSTMENT WHEN
WATER IS TOO COLD
CARTRIDGE
AERATOR
HOTLINE FOR HELP
1 (800) 223-0068
SEALS
P0P-UP
ROD
78523C