Installation
Instructions
ENFIELD
DECK-MOUNT BATH FILLER
with EverClean™ Finish
Congratulations on purchasing your American
Standard faucet with EverClean finish found
only on American Standard faucets.
EverClean Finish
• One wipe effortlessly removes spots
• Eliminates the need for cleaners and scrubbing
• Permanent surface protectant remains beautiful
for the life of the faucet
• EverClean™ available on: Polished Chrome, Satin Nickel,
Stainless Steel, Polished Brass (or any combination of these finishes)
To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin.
IMPORTANT NOTICE TO INSTALLER!
Please check with local Code Authority for the installation requirements of this product. Some codes require an
additional temperature mixing valve to limit the maximum hot water temperature and vacuum breaker
(for products with hand spray) to be installed with this product.
2373.900
2373.920
2373.901
2373.921
Certified to comply with ANSI A112.18.1M
M968288 Rev. 1.1
Required Tools
Flat Blade Screwdriver
ROUGHING-IN DIMENSIONS
MOUNTING
SURFACE
8"
Adjustable Wrench
5-3/16"
3-3/4"
1-1/8 DIA.
LEVER
HANDLE
2-7/8"
Channel Locks
ADJ. 6-1/2 TO 12
2-7/8
DIA.
1-1/4
MAX.
*Hex key
*Supplied with Fitting
CROSS
HANDLE
2-1/4
DIA.
3
*Wrench
2-1/16
DIA.
1-1/2 MAX.
8-3/16
3/4-14 MALE
N.P.T. INLETS
(H)
1-1/16 DIA.
1-3/16 DIA.
(C)
12 MAX

SPOUT ASSEMBLY
1
CAUTION
Install RING WASHER (1) into SPOUT BASE recess. Check
that O-RING (2) on end of SPOUT SHANK (3) is in place. Insert
SPOUT SHANK (3) through SPOUT ESCUTCHEON (4) and
into center hole on mounting surface.
Assemble RUBBER WASHER (5) and LOCKNUT (6) onto SPOUT
SHANK (1). Align SPOUT ASSEMBLY and from underside of ledge
secure SPOUT ASSEMBLY into position with LOCKNUT (6).
Turn off hot and cold water
supplies before beginning.
SPOUT
ASSEMBLY
PREPARE TUBE AND TEE ASSEMBLY
2
Prepare TUBE and TEE ASSEMBLY (1) to fit center to center
VALVE (2) location (between 6-1/2" and 12"). If necessary,
cut and/or bend TUBING carefully. Make sure tube bend is
close to the TEE (1) so that it will not effect the compression
joint at the VALVE CONNECTION.
Remove COUPLING NUT (3) and FERRULE (4) from each
VALVE (2) and slide onto TUBING (5).
4
3
1
5
3
4
SPOUT BASE
RECESS
2
2
1
3
4
5
6
VALVE ASSEMBLY
3
Install LOCKNUTS (1) and RUBBER WASHERS (2) onto valve shanks.
Push TUBING (3) ends into VALVE (4) side outlets. Insert VALVES (4)
into mounting holes from underside of ledge.
Press TEE (5) onto SPOUT SHANK (6) making certain that the O-RING (7) is
properly seated on SHANK (6). Push COUPLING (8 or 8a) into TEE (5) and
attach to SPOUT SHANK (6) and tighten. Note: For product with Hand
Shower, COUPLING (8) is tightened using a 10mm (3/8”)
Hex Wrench.
Thread of VALVE BODY (4) should extend at least 5/16 inch above
MOUNTING SURFACE (11). If necessary, adjust LOCKNUT (1).
Place RUBBER RING (10) into ESCUTCHEON ADAPTERS (9) and thread onto
valves until snug against internal stop.
Tighten LOCKNUT (1) to secure VALVE (4) position.
Slide FERRULE (12) and COUPLING NUT (13) to outlet of VALVE (4) and tighten
COUPLING NUT (13) firmly.
Connect HOT water supply to inlet of
left VALVE and COLD water supply to
inlet of right VALVE using appropriate
connector.
5/16'' MIN.
10
4
MOUNTING
SURFACE
9
11
2
1
NOTE
MOUNTING
SURFACE
FOR FITTING
LESS SPRAY
ADJ. 6-1/2 TO 12
VALVE inlet is 3/4-inch NPT male.
9
10
4
12
HOT
13
3
5
88a
MOUNTING
9
10
7
6
12
13
SURFACE
2
11
MOUNTING
SURFACE
4
COLD
M968288 Rev. 1.1

INSTALL HANDLES
4
Push ADAPTER (1) on VALVE STEM (2), so that the hole of the
ADAPTER (1) without a spline is facing up. See figure "A". Tighten
STEM SCREW (3) to secure ADAPTER (1).
Find correct position of LEVER HANDLE ASSEMBLY (4) or CROSS
HANDLE ASSEMBLY (5) by adjusting male teeth on ADAPTER (1) to
female teeth in HANDLE (4, 5).
Thread LEVER HANDLE ASSEMBLY (4) or CROSS HANDE ASSEMBLY (5)
onto DECK ADAPTER (6) until snug against mounting surface.
4 5
TOP
Figure "A"
THREAD ON
TO DECK
ADAPTER
1
3
2
SERVICE
5
To change direction of handle rotation,
proceed as follows:
Turn valve to OFF position. Unthread HANDLE BASE (1) from DECK
ADAPTER (2).
Pull HANDLE ASSEMBLY off VALVE STEM (3).
Remove SPRING CLIP (4). Lift STOP WASHER (5), turn 90° and replace.
Replace SPRING CLIP (4).
Find correct position of HANDLE ASSEMBLY by adjusting male teeth on
VALVE STEM (3) to female teeth in HANDLE.
Thread HANDLE ASSEMBLY onto DECK ADAPTER (2) until snug against
mounting surface.
HANDSHOWER INSTALLATION (FOR 2373.901/921)
6
SPLINE END DOWN
UNTHREAD
2
6
HANDLE ASSEMBLY
1
90$
3
5
4
Drop SPRAY ESCUTCHEON (1) through the fourth hole of the tub ledge (12" max from SPOUT
center) with SPRAY ESCUTCHEON (1) directed towards tub center. Be sure RUBBER RING (2)
is properly seated in ESCUTCHEON (1). Install RUBBER WASHER (3) and LOCKNUT (4) from
underside of ledge.
Secure SPRAY ESCUTCHEON (1) by tightening LOCKNUT.
Add SEAL WASHER (5) and connect HOSE (10) to outlet nipple
at the bottom of COUPLING (7). on the SPOUT SHANK (6).
Tighten firmly.
Slip SHOWER HOSE (8) with COUPLING NUT through SPRAY
ESCUTCHEON (1). Install SEALS (9) and connect both HOSES (8)
and (10), Connect HAND SHOWER (11) to SPRAY HOSE (8).
NOTE
When not in use, HANDSHOWER should be seated
in the HOLDER.
7
5
10
11
9
6
1
2
3
4
LOCKNUT
8
9
M968288 Rev. 1.1

TEST INSTALLED FAUCET
7
Turn VALVES (1) to "off" position.
With handles in "off" position, turn on water supplies and check
all connections for leaks.
Operate both handles and flush water lines thoroughly.
Check SPOUT (2) mounting for leaks.
Lift HAND SHOWER (3) from holder, direct spray into tub, lift
TRANSFER KNOB (4) to check HAND SHOWER (3) and HOSES for leaks.
Turn VALVES "off."
If spout drips, operate handles several times from OFF to ON position.
Do not force - handles turn only 90°.
CAUTION
The flow rate of this Tub Filler exceeds 20 gallons/minute
at higher water pressure. Do not fill bathtub unattended.
1 4
1
2
3
Before the bathroom is completely finished, you may
want to remove spout, hand shower, and handles.
8
To remove handles, reverse steps in section 4.
To remove SPOUT (1), proceed as follows:
Lift TRANSFER ROD (8) and unscrew KNOB (2).
Remove PLUG BUTTON (3) and remove SET SCREW (4) using 5mm hex
wrench supplied.
Lift SPOUT (1) off SHANK (5) carefully and remove RUBBER
RING (6).
Unscrew SHANK SLEEVE (7) and lift TRANSFER ROD (8) from
SHANK (5).
Reverse sequence to re-install SPOUT (1). Be sure RUBBER
RING (6) is properly seated in its recess at the base of SPOUT (1).
Make certain SET SCREW (5) is properly aligned and tight so that
SPOUT (1) is locked in place.
EverClean™ Finish Care Instructions
9
2
1
8
American Standard’s EverClean finish will wipe clean with a soft, dry cloth. A soft cloth with
clean water may also be used, if desired. No additional cleaning products are required.
4
3
Hex wench, supplied
6
7
5
DO NOT USE: Soaps, acid, polish, abrasives, harsh cleaners, or a cloth with a coarse surface.
For toll-free information and answers to your questions, call:
IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)
Product names listed herein are trademarks of American Standard Inc.
©American Standard Inc. 2002
HOT LINE FOR HELP
1 (800) 442-1902
Weekdays 8:00 a.m. to 8:00 p.m. EST
IN MEXICO 01-800-839-12-00
Weekdays 8:00 a.m. to 7:00 p.m. EST
M968288 Rev. 1.1