American Standard 0421.018, 0431.066 User Manual

PRISON LAVATORY
• Integral spout and drinking nozzle
• Soap depression
• Outlet connection to slip 1-1/4" O.D. tubing
0421.018 China only with integral drain
0431.066 China only w/non-removable stopper
Available Components:
002250.090 Self-closing hot and cold tting for
0" to 4" (0 to 102mm) wall
002250.108 Self-closing hot and cold tting for
4" to 9" (102 to 229mm) wall
002423.010 Drain with non-removable stopper
Nominal Dimensions:
356 x 324mm (14" x 12-3/4")
Compliance Certications ­Meets or Exceeds the Following Specications:
• ASME A112.19.2 for Vitreous China Fixtures
PRISON LAVATORY
VITREOUS CHINA
SEE REVERSE FOR ROUGHING-IN DIMENSIONS
To Be Specied:
1-1/4" Trap:
Available in White Only
© 2008 AS America Inc.
M39
Revised 6/04
PRISON LAVATORY
787 mm
(31 )
TO FINISH ED FL OOR
298 mm
(11 -3/4)
121 mm
(4- 3/4)
241 mm (9- 1/2)
51m m
(2)
57m m (2- 1/4)
356 mm
(14 )
324 mm
(12 -3/4)
203 mm
(8)
83m m
(3- 1/4)
3/8 N.P.T . COL D
57m m
(2- 1/4)
83m m
(3- 1/4)
0 T O 4 WA LL
(3) 38mm (1-1/ 2) DIA . HOL ES IN WAL L
TO SLIP 1 -1/4 O.D . TUBI NG
76m m(3) D IA. H OLE FOR SPUD (ON C /L)
C/L
3/8 N.P.T . HOT
57m m
(2- 1/4)
787 mm
(31 )
TO FINISH ED FL OOR
298 mm
(11 -3/4)
121 mm
(4- 3/4)
241 mm (9- 1/2)
51m m
(2)
57m m (2- 1/4)
356 mm
(14 )
324 mm
(12 -3/4)
330 mm
(13 )
83m m
(3- 1/4)
3/8 N.P.T . COL D
57m m
(2- 1/4)
83m m
(3- 1/4)
4 T O 9 WA LL
(3) 38mm (1-1/ 2) DIA . HOL ES IN WAL L
TO SLIP 1 -1/4
O.D . TUBI NG 76m m(3) D IA. H OLE FOR SPUD (ON C /L)
C/L
3/8 N.P.T . HOT
57m m
(2- 1/4)
VITREOUS CHINA
0431.066/0421.018
0" to 4" WALL THICKNESS
0431.066/0421.018
4" to 9" WALL THICKNESS
© 2008 AS America Inc.
NOTES:
THESE LAVATORIES DO NOT HAVE A TRAP. PROVISIONS MUST BE MADE FOR INSTALLATION OF TR AP IN WALL.
0431.SERIES SHOWN. 0421.SERIES SAME EXCEPT WITH INTEGRAL SLOW­DRAINING OUTLET.
IMPORTANT: Dimensions of xtures are nominal and may vary within the range of tolerances established by ANSI Standard A112.19.2. These measurements are subject to change or cancellation. No responsibility is assumed for use of superseded or voided pages
M40
Revised 6/04
Loading...