Unplug unit
Remove existing wire harness.
Attach the following:
o Control Board molex connector o Auger Motor black wire to Vacuum Pressure switch (Com) grey wire to one lead o Electrical Plug double white wire to inside terminal (top, right side) Black/orange
terminal other end of green wire screwed to base of unit o Vacuum Pressure Switch grey wire to left terminal black wire to middle terminal if Clark
grey wire to left terminal black wire to right terminal of World Magnetic
N.O.
N.C.
COM
RT080 World Magnetics Vacuum Pressure Switch
o Room Fan Sensor double white wire to
bottom terminal green wire to top terminal
o High Limit Sensor blue wire to bottom terminal double grey to top terminal o Room Air Fan white wire to red wire grey wire to double black wire o Exhaust Fan black wire to white wire red wire to black wire
Wire Harness Assembly
Part #P6115
For Models 6500 units
wire to outside terminal (top, left side) green wire to bottom
N.O.
1
N.O.
Attach one grey wire to ‘Com ’
and one grey wire to ‘NO’.
Attached hose to back
connection ‘L’.
Attach one grey wire to ‘Com 1’
and one grey wire to ‘NO 3’.
Attached hose to bottom connection
‘P2’.
2
N.O.
3
RT080 Clark Controls
Vacuum Pressure Switch
N.O.
2
N.O.
1
N.O.
3
looking in from side w/o control panel
F:\AESBusinessSystems\AES Technical\Piece part instructions\P6115 Wire Harness Assembly 6500.doc
p
ue
Magnum 6500 Wiring Diagram
Circuit Board Control
AES # MF3593
MF3650 2-speed exhaust blower to be wired using the white and black leads red lead is not used.
Exhaust Motor AES # MF3650
Auger Gear Motor AES # CF26
White neutral
Red
Black
White neutral
Black
2 wire low voltage thermostat
Vacuum pressure switch
Gray
Bl
Fan limit sensor
Fan
Gray
High Limit sensor
power
200 deg. High limit snap disk
Proof of fire sensor 110 deg
AES # MF3537
Blower
Black
Power Cord Receptacle showing back of plug
white
Green Ground
A 200-degree high limit control has to be installed in the primary furnace duct work below the Magnum 7500 hot air outlet in a supplementary furnace installation only.
1240 cfm
Grainger Motor#3M393
AES # CF24
white
Black from blower fan to
ower receptacle
The High limit control is pre-set and does not need to be adjusted. If the furnace is overheating consult your HVAC installer for proper duct installation, pressures and sizing.
The fan limit control heat settings are pre-set and do not need to be changed. If the room fan is cycling often consult your HVAC contractor for proper duct pressure setting.
F:\AESBusinessSystems\AES Technical\Piece part instructions\P6115 Wire Harness Assembly 6500.doc