American Energy Systems MF3542 User Manual

MF3542 Exhaust Blower
All Magnum pellet units
Turn off power on control panel and unplug from the power supply.
Disconnect the exhaust blower leads from the wire harness make sure when pulling off
wires that you use pliers by the end of the terminals, so you don’t pull out the wire from the ends.
Remove existing exhaust tube from the
exhaust blower being replaced.(save the #8-tek screws for later use)
Clean the rectangle outlet of the exhaust tube of any old high temp silicone.
Place a 1/8” bead of high temp silicone on the rectangle outside edge of the exhaust tube.
Slip rectangle end of the exhaust tube over the rectangle outlet of the new exhaust
blower. Push tight until the exhaust tube hits the flange of the exhaust blower housing. Making sure the tube alignment to blower is straight.
F:\AESBusinessSystems\AES Technical\Piece part instructions\MF3542 Exhaust Blower.doc
Neatly, compress caulking using finger around all four sides of the exhaust tube. Make sure equal amounts of caulk are on the exhaust tube and the exhaust housing providing a leak free seal.
Fasten the exhaust tube to the blower housing using the #8 tek screws listed above.
From the back of the unit, look into the exhaust tube. If any high temp silicone is visible clean out with a hacksaw blade.
F:\AESBusinessSystems\AES Technical\Piece part instructions\MF3542 Exhaust Blower.doc
Loading...
+ 1 hidden pages