This manual describes the installation and operating procedures for the American Dynamics model 1218 Unit. The 1218 Pan/Tilt is a high quality, light duty unit which has been specifically designed for indoor operation. The unit has been specially developed for small CCD cameras and camera housings. It is quick and easy to install with easily adjustable limit stops. The 1218 is available with and without presets.
Page 2
The software/firmware furnished with this equipment is confidential to and is copyrighted by AMERICAN DYNAMICS. It is not to be copied or disclosed in any manner without the express written consent of AMERICAN DYNAMICS. The software/firmware is furnished to the purchaser under a license for use on a single system.
Information furnished by AMERICAN DYNAMICS is believed to be accurate and reliable. However, no responsibility is assumed by AMERICAN DYNAMICS for its use; nor for any infringements of other rights of third parties which may result from its use. No license is granted by implications or otherwise under any patent or patent rights of AMERICAN DYNAMICS.
Page 3
The installation of this product should be made by qualified
service personnel and should conform to all local codes.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK,
!
AMERICAN
DYNAMICS
The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated "dangerous voltage" within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
DO NOT REMOVE COVERS (OR BACK) .
NO USER-SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL
WWWWAAAARRRRNNNNIIIINNNNGG
To reduce the risk of fire or shock hazard, do
not expose this product to rain or moisture.
Warning: This product generates, uses, and can radiate radio frequency energy and if not installed and used in accordance with the instructions manual, may cause interference to radio communications. It has been tested and found to comply with the limits for a Class A computing device pursuant to Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference when operated in a commercial environment. Operation of this product in a residential area is likely to cause interference in which case the user at his own expense will be required to take whatever measures may be required to correct the interference.
GG
The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance
!
UUUUNNNNPPPPAAAACCCCKKKKIIIINNNNGGGG AAAANNNNDDDD IIIINNNNSSSSPPPPEEEECCCCTTTTIIIIOOOONN
Unpack carefully. This is an electronic product and should be handled as such. Compare the items received with the packing list with your order.
Be sure to save:
1. The shipping cartons and insert pieces. They are the ) safest material in which to make future shipments of the product.
2. The IMPORTANT SAFEGUARDS sheet.
3. These Installation and Operating Instructions.
MMMMAAAAIIIINNNNTTTTEEEENNNNAAAANNNNCCCCEE
User maintenance of this unit is limited to external cleaning and inspection. For specific recommendations refer to the IMPORTANT SAFEGUARDS sheet packaged with this product.
IIIINNNNSSSSTTTTAAAALLLLLLLLAAAATTTTIIIIOOOONNNN AAAANNNNDDDD SSSSEEEERRRRVVVVIIIICCCCEE
If you require information during installation of this product or if service seems necessary, contact the American Dynamics Repair and Service Department at (800) 442-2225. You must obtain a Return Authorization Number and shipping instructions before returning any product for service.
(servicing) instructions in the literature accompanying the product.
NN
EE
EE
Do not attempt to service this product yourself. Opening or removing covers may expose you to dangerous voltages or other hazards. Refer all servicing to qualified personnel.
QA301C
Page 4
Page 5
Table of Contents
Description............................................................... 1
Installation................................................................ 1
Mounting.................................................................. 2
Ceiling Mounting........................................... 2
Wall Mounting............................................... 2
Connections, Adjustments........................................ 3
Connecting the Pan/Tilt ................................. 3
Adjusting Angles of Movement..................... 3
Dimensions............................................................... 4
Specifications........................................................... back page
Page 6
Page 7
Page 8

MOUNTING

The 1218 Pan unit can be wall or ceiling mounted.

Mounting the Unit from the Ceiling

The 1218 is supplied with a ceiling mount (see Figure 2) adapter plate bolted to the base. The base has four holes which accept 6 mm bolts on a 4-inch (101.6 mm) diameter. The unit can be attached directly to the ceiling by bolting or screwing through these holes.

Wall Mounting Using the 1391 Mount

Mount the head on a 1391 mount in the following way:
• Three heavy duty screws are recommended for securing the bracket.
• Bolt the 1218 unit to the bracket using the three 6 mm bolts and washers supplied as shown in Figure 3. The ceiling adapter plate is not used when mounting the head to a wall bracket.
Note: If the unit is mounted upside down, reposition the
platform through 180°. Remember that the directions of pan and tilt are reversed.
MOUNTING
Figure 3 - Attaching 1218 Pan/Tilt to the 1391 Wall mount
2
Four holes to fit 6 mm bolts
on 4" (101.6 mm) PCD
Three holes to fit 6 mm bolts
on 1.97" (50 mm) PCD
Figure 2 - Attaching 1218 Pan/Tilt to Ceiling mount
Page 9

CONNECTING THE UNIT

The 1218 Series indoor pan/tilt unit has a cable approximately
1.5 m in length which connect to a controller with 16/0.2 cable rated at 240V. Leave enough slack on the cable to prevent straining the cable when the head is panning. Figure 3 shows the standard wiring color scheme for the 1218.

ADJUSTING THE ANGLES OF MOVEMENT

Adjusting the Pan Axis Angle of Movement

Make sure the 1218 is disconnected from the control source.
• The Pan Axes Limit Contact Arms are accessible from the underside of the 1218 (see Figure 5).
• Loosen the Pan Limit Switch Contact Arms with a 4 mm Allen wrench.
• Rotate the arms until the desired pan range is achieved.
• Re-tighten the Contact Arm set-screws and test the 1218 for correct pan operation.

Adjusting the Tilt Axis Angle of Movement

Make sure the 1218 is disconnected from the control source.
• Remove the plastic cover from the rear of the main body to expose the Limit Switch Contact Arms (see Figure 6).
• Using a flat-faced screw-driver, turn the lock-down screw counter-clockwise slightly until the limit striker arms begin to loosen.
• Rotate the Contact Arms until the desired tilt angle is achieved.
• Re-tighten the lock-down screw and test the 1218 for correct tilt operation.
RED - Pan Right
BLK - Pan Return
VIO - Tilt Up
WHT - Tilt Return
YEL - Tilt Wiper
GRN - Pan Wiper
BRN - Pot Supply
BLU - Pot Supply
Figure 4 - 1218 Wiring Connections
Tilt Limit Switch Rocker Arm
Tilt Limit Switch Contact Arms
Figure 6 - Adjusting Tilt Axis Angle of Movement
Pan Limit Switch Contact Arms
Pan Limt Switch Rocker Arm
Figure 5 - Adjusting Pan Axis Angle of Movement
CONNECTIONS, ADJUSTMENTS
3
IF YOU ENCOUNTER ANY PROBLEMS OPERATING
THIS UNIT, OR NEED ASSISTANCE, CALL OUR
TECHNICAL SUPPORT CENTER AT:
within the United States: 1-800-442-2225 outside the United States: (914) 624-7640
Page 10
2.5625" (65.09 mm)
3.94" (100 mm)
2.75" (69.85 mm)
5.563" (141.3 mm)
2.75" (69.85 mm)
5.625" (142.88 mm)
.375" (9.53 mm)

DIMENSIONS

4
Figure 7 - 1218 Dimensions
Page 11
Page 12

SPECIFICATIONS

MECHANICAL
Weight Class: Light Duty
Maximum Load: 11 lbs. (5 Kg)
Pan:
Speed: 0-60°/sec. Range: 360°
Tilt:
Speed: 0-5.0°sec. Range: ± 25° from horizontal
Backlash: Less than 0.25%
Construction: Die-cast aluminum
Finish: Light beige powder coat enamel
Weight of Unit: 4.5 lbs. (2.0 Kg)
Overall Dimensions: 5.7"H x 4.9" W x 4.7" D
(144 mm H x 125 W mm x 120 mm D)
ELECTRICAL
Power requirements: 0-12VDC @ 50/60 Hz
Pan Operating Current: 250mA
Tilt Operating Current: 250mA
Limit Control: Adjustable, microswitch
ENVIRONMENTAL
Operating Environment: Indoor
Operating Temperature: +14°F to +140°F (-10°C to +60°C)
MODELS
AD1218//12 DC 12 VDC operation with no presets
AD1218/12DCP Same as AD1218/12DC with factory installed feedback potentiometers. Provides pan and tilt
position feedback for control by equipment having the same feature.
SPECIFICATIONS
An American Dynamics Product
Designed and built by
Sensormatic CCTV Systems Division
One Blue Hill Plaza
Pearl River, New York, 10965
(914) 624-7600
Technical Support Center: 800-442-2225
FAX: (914) 624-7685