American DJ Vizi CMY 300 Service Manual

VIZI CMY300
User Instructions
©2018 ADJ Products, LLC all rights reserved. Information, specications, diagrams, images, and
instructions herein are subject to change without notice. ADJ Products, LLC logo and identifying product names and numbers herein are trademarks of ADJ Products, LLC. Copyright protection claimed includes all forms and matters of copyrightable materials and information now allowed by statutory or judicial law or hereinafter granted. Product names used in this document may be trademarks or registered trademarks of their respective companies and are hereby acknowledged. All non-ADJ Products, LLC brands and product names are trademarks or registered trademarks of their respective companies.
ADJ Products, LLC and all aliated companies hereby disclaim any and all liabilities for property,
equipment, building, and electrical damages, injuries to any persons, and direct or indirect economic loss associated with the use or reliance of any information contained within this document, and/or as a result of the improper, unsafe, unsucient and negligent assembly, installation, rigging, and opera­tion of this product.
DOCUMENT VERSION
Please check www.adj.com for the latest revision/update of this guide.
Date
12/06/17
01/25/18
Document
Version
1 1.00
2
Software
Version
1.1
>
DMX
Channel
Mode
Notes
24/26/38 Initial Release
NO CHANGE
System Menu Updated Offset Menu Updated Error Codes Added
Europe Energy Saving Notice Energy Saving Matters (EuP 2009/125/EC)
Saving electric energy is a key to help protecting the enviroment. Please turn o all electrical products when
they are not in use. To avoid power consumption in idle mode, disconnect all electrical equipment from power when not in use. Thank you!
Vizi CMY300 Table of Contents
Introduction
Features / Warranty Registration / Installation
Safety Precautions
Mounting
DMX Set Up
DMX Addressing
Control Panel & Connections
DMX Channel Modes
System Menu Operating Instructions
Oset Menu
3
4
5
7
9
11
12
13
29
30
36
Error Codes
Gobo Specications
Gobos
Gobo Replacement
Dimmer Curve Chart
Dimensional Drawings
Multiple Unit Power Linking
Fuse Replacement Warranty
Technical Specications
39
40
41
42
42 43
44
44
45
46
ADJ Products, LLC - www.adj.com - Vizi CMY300 User Manual Page 2
Vizi CMY300 Introduction
Unpacking: Thank you for purchasing the Vizi CMY300 by ADJ Products, LLC. Every Vizi CMY300 has been thoroughly tested and has been shipped in perfect operating condition. Carefully check the shipping carton for damage that may have occurred during shipping. If the carton appears to be damaged, carefully inspect your xture for any damage and be sure all accessories necessary to operate the unit has arrived intact. In the case damage has been found or parts are missing, please contact our toll free
customer support number for further instructions. Do not return this unit to your dealer without rst
contacting customer support.
Introduction: The ADJ Vizi CMY300 is a DMX intelligent, high powered, CMY LED moving head fixture. To optimize the performance of this product, please read these operating instructions carefully to familiarize yourself with the basic operations of this unit. These instructions contain important safety information regarding the use and maintenance of this unit. Please keep this manual with the unit, for future reference.
Customer Support: ADJ provides a customer support line, to provide set up help and to answer any question should you encounter problems during your set up or initial operation. You may also visit us on the web at www.adj.com for any comments or suggestions. Service Hours are Monday through Friday 8:00 a.m. to 4:30 p.m. Pacic Standard Time. Voice: (323) 582-2650 Fax: (323) 582-2941 E-mail: support@AmericanDJ.com
Warning! To prevent or reduce the risk of electrical shock or re, do not expose this unit to rain or
moisture. Caution! There are no user serviceable parts inside this unit. Do not attempt any repairs yourself, doing so will void your manufactures warranty. In the unlikely event your unit may require service please contact ADJ Products, LLC.
PLEASE recycle the shipping carton when ever possible.
ADJ Products, LLC - www.adj.com - Vizi CMY300 User Manual Page 3
Vizi CMY300 Features
• Electronic Dimming 0-100%
• DMX-512 protocol
• 3-Pin and 5-Pin DMX Connection
• powerCON Input & Output
• Colors: 9 + Open (Including CTO 3200K & UV)
• GOBO Wheel 1: 7 Rotating/Replaceable + Open GOBO Wheel 2: 9 Fixed + Open
• Prism 1: Rotating 3-facet Circular
• Prism 2: Rotating 6-facet Linear
• Linear Frost Effect
• Motorized Focus
• Motorized Zoom
• Three DMX Modes: 24 Channel Mode, 26 Channel Mode, and 38 Channel Mode.
• Multiple Unit Power Linking (See page 44)
Vizi CMY300 Warranty Registration
The Vizi CMY300 carries a 2 year limited warranty. Please fill out the enclosed warranty card to validate your purchase. All returned service items whether under warranty or not, must be freight pre­paid and accompany a return authorization (R.A.) number. The R.A. number must be clearly written on the outside of the return package. A brief description of the problem as well as the R.A. number must also be written down on a piece of paper included in the shipping carton. If the unit is under war­ranty, you must provide a copy of your proof of purchase invoice. You may obtain a R.A. number by contacting our customer support team on our customer support number. All packages returned to the service department not displaying a R.A. number on the outside of the package will be returned to the shipper.
Vizi CMY300 Installation
The unit should be mounted using a mounting clamp (not provided), axing it to the mounting bracket that is provided with the unit. Always ensure that the unit is rmly xed to avoid vibration
and slipping while operating. Always ensure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 times the unit’s weight. Also, always use a safety cable
that can hold 12 times the weight of the unit when installing the xture. The equipment must be
installed by a professional, and it must be installed in a place where it is out of the reach of people’s grasp.
ADJ Products, LLC - www.adj.com - Vizi CMY300 User Manual Page 4
Vizi CMY300 Safety Precautions
• To reduce the risk of electrical shock or re, do not expose this unit rain or moisture
• Do not spill water or other liquids into or on to your unit.
• Do not attempt to operate this unit if the power cord has been frayed or broken. Do not attempt to remove or break o the ground prong from the electrical cord. This prong is used to reduce the risk of electrical shock and re in case of an internal short.
• Disconnect from main power before making any type of connection.
• Do not remove the cover under any conditions. There are no user serviceable parts inside.
• Never operate this unit when it’s cover is removed.
• Never plug this unit in to a dimmer pack
• Always be sure to mount this unit in an area that will allow proper ventilation. Allow about 6”
(15cm) between this device and a wall.
• Do not attempt to operate this unit, if it becomes damaged.
• This unit is intended for indoor use only, use of this product outdoors voids all warranties.
• During long periods of non-use, disconnect the unit’s main power.
• Always mount this unit in safe and stable matter.
• Power-supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them, paying particular attention to the point they exit from the unit.
• Cleaning -The fixture should be cleaned only as recommended by the manufacturer. See page 44
for cleaning details.
• Heat -The appliance should be situated away from heat sources such as radiators, heat registers,
stoves, or other appliances (including amplifiers) that produce heat.
• The fixture should be serviced by qualified service personnel when:
A. The power-supply cord or the plug has been damaged.
B. Objects have fallen, or liquid has been spilled into the fixture. C. The fixture has been exposed to rain or water. D. The fixture does not appear to operate normally or exhibits a marked change in performance. E. The fixture has fallen and/or subjected to extreme handling.
ADJ Products, LLC - www.adj.com - Vizi CMY300 User Manual Page 5
Vizi CMY300 Safety Precautions
RISK GROUP 3 - RISK OF EXPOSURE TO ULTRAVIOLET (UV) RADIATION!
FIXTURE EMITS HIGH INTENSITY ULTRAVIOLET (UV) LIGHT AT A WAVELENGTH OF 399NM - 435NM.
WEAR PROPER EYE AND SKIN PROTECTION.
AVOID PROLONGED PERIODS OF EXPOSURE.
AVOID WEARING WHITE COLOR CLOTHING AND/OR USING (UV) PAINTS ON SKIN.
AVOID DIRECT EYE AND/OR SKIN EXPOSURE AT DISTANCES SHORTER THAN 11 feet (3.3m).
DO NOT OPERATE FIXTURE WITH DAMAGED OR MISSING EXTERNAL COVER PROTECTIVE LENS.
DO NOT LOOK DIRECTLY INTO THE (UV) LIGHT AND/OR VIEW (UV) LIGHT DIRECTLY WITH OPTICAL INSTRUMENTS THAT MAY CONCENTRATE THE LIGHT/RADIATION OUTPUT.
INDIVIDUALS SUFFERING FROM A RANGE OF EYE CONDITIONS, SUNLIGHT EXPOSURE DISORDERS, OR INDIVIDUALS USING PHOTOSENSITIVE MEDICATION, MAY RECEIVE DISCOMFORT IF EXPOSED TO THE ULTRAVIOLET (UV) LIGHT EMITTED FROM THIS FIXTURE.
ADJ Products, LLC - www.adj.com - Vizi CMY300 User Manual Page 6
Vizi CMY300 Mounting
When installing the unit, the trussing or area of installation must be able to hold 10 times the weight without any deformation. When installing the unit must be secured with a secondary safety attach­ment, e.g. and appropriate safety cable. Never stand directly below the unit when mounting, remov­ing, or servicing the unit.
Overhead mounting requires extensive experience, including calculating working load limits, installa­tion material being used, and perodic safety inspection of all installation material and unit. If you lack
these qualications, do not attempt the installation yourself.
These installaiton should be checked by a skilled person once a year.
The Vizi CMY300 is fully operational in three dierent mounting positions, hanging upside-down from a ceiling, sideways on trussing, or set on a at level surface. Be sure this xture is kept at least 12m (40ft) away from any ammable materials (decoration etc.). Always use and install the supplied safety
cable as a safety measure to prevent accidental damage and/or injury in the event the clamp fails
(see next page). Never use the carrying handles for secondary attachment.
ADJ Products, LLC - www.adj.com - Vizi CMY300 User Manual Page 7
Vizi CMY300 Mounting
NOTICE: The suitable enviromental temperature for this lighting xture is between -25˚ C to 45˚ C.
Do not place this lighting xture in an enviroment where the temperatures are under or above the temperatures stated above. This will allow the xture to run at its best and help prolong the xture
life.
1.BolteachclamptotheOmegaholderwithscrewandlocknutthroughtheholeintheholder.
2.Fastentheomegaholdersonthebottomofthebasebyinsertingquick‐lockfastenersintotheholes
ofthebaseandtightenfullyclockwise. 
3.Hangthexturetothesupport using the clamps andtighten thescrews.Fasten a safetycablethrough
thebottomofthebaseandoverthesupport.
1.Clamp
2.Omega-holders
3.Quick-lock fastener
Screw one clamp each via a M12 screw and nut into the Omega holders. Insert the quick-lock fas­teners of the Omega holder’s into the respective holes on the bottom of the Vizi CMY300. Tighten the quick-lock fasteners fully clockwise. Install the second Omega holder. Pull the safety-cable
through the openings located on the base plate and over the trussing system or a safe xation spot.
Insert the end in the carabine and tighten the safety screw.
ADJ Products, LLC - www.adj.com - Vizi CMY300 User Manual Page 8
Vizi CMY300 DMX Set Up
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
DMX512
DMX+,DMX-,COMMON
1
2
3
Termination reduces signal errors and avoids signal transmission problems and interference. It is always advisable to connect a DMX terminal, (Resistance 120 Ohm 1/4 W) between PIN 2 (DMX-) and PIN 3 (DMX +) of the last fixture.
Power Supply: The ADJ Vizi CMY300 contains a automatic voltage switch, which will auto sense the voltage when it is plugged into the power source. With this switch there is no need to worry about the correct power voltage, this unit can be plugged in anywhere.
DMX-512: DMX is short for Digital Multiplex. This is a universal protocol used as a form of communication between intelligent fixtures and controllers. A DMX controller sends DMX data instructions from the controller to the fixture. DMX data is sent as serial data that travels from fixture to fixture via the DATA “IN” and DATA “OUT” XLR terminals located on all DMX fixtures (most controllers only have a DATA “OUT” terminal).
DMX Linking: DMX is a language allowing all makes and models of dierent manufactures to be linked together and operate from a single controller, as long as all xtures and the controller are DMX compliant. To ensure proper DMX data transmission, when using several DMX fixtures try to use the shortest cable path possible. The order in which fixtures are connected in a DMX line does not influence the DMX addressing. For example; a fixture assigned a DMX address of 1 may be placed anywhere in a DMX line, at the beginning, at the end, or anywhere in the middle. When a fixture is
assigned a DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that unit, no matter where it is located in the DMX chain.
Data Cable (DMX Cable) Requirements (For DMX Operation): The Vizi CMY300 can be controlled via DMX-512 protocol. The Vizi CMY300 has 3 DMX channel modes. Your unit and your DMX controller require a standard 3-pin XLR connector for data input and data output (Figure 1). We recommend Accu-Cable DMX cables. If you are making your own cables, be sure to use standard 110-120 Ohm shielded cable (This cable may be purchased at almost all pro lighting stores). Your cables should be made with a male and female XLR connector on either end of the cable. Also remember that DMX cable must be daisy chained and cannot be split.
Figure 1
Notice: Be sure to follow gures two and three when making your own cables. Do not use the ground
lug on the XLR connector. Do not connect the cable’s shield conductor to the ground lug or allow the shield conductor to come in contact with the XLR’s outer casing. Grounding the shield could cause a short circuit and erratic behavior.
XLR Male Socket
1 Ground
Figure 3
DMX512 OT
3-PIN XLR
2 Cold
3 Hot
1
3
2
XLR Female Socket
2 Cold
COMMON
DMX +
DMX -
1 Ground
3 Hot
1
DMX512 IN
3
3-PIN XLR
2
Figure 2
XLR Pin Conguration
Pin 1 = Ground
Pin 2 = Data Compliment (negative)
Pin 3 = Data True (positive)
ADJ Products, LLC - www.adj.com - Vizi CMY300 User Manual Page 9
Vizi CMY300 DMX Set Up
POWER
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
and PIN 3 (DMX +) of the last fixture.
Special Note: Line Termination.
When longer runs of cable are used, you may need to use a terminator
on the last unit to avoid erratic behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is con-
nected between pins 2 and 3 of a male XLR connector (DATA + and DATA -). This unit is inserted in the
female XLR connector of the last unit in your daisy chain to terminate the line. Using a cable terminator
(ADJ part number Z-DMX/T) will decrease the possibilities of erratic behavior.
Termination reduces signal errors and
1
3
avoids signal transmission problems and interference. It is always advisable
2
to connect a DMX terminal, (Resistance 120 Ohm 1/4 W) between PIN 2 (DMX-)
Figure 4
5-Pin XLR DMX Connectors.
Some manufactures use 5-pin DMX-512 data cables for DATA transmis-
sion in place of 3-pin. 5-pin DMX xtures may be implemented in a 3-pin DMX line. When inserting
standard 5-pin data cables in to a 3-pin line a cable adaptor must be used, these adaptors are readily available at most electric stores. The chart below details a proper cable conversion.
3-Pin XLR to 5-Pin XLR Conversion
Conductor 5-Pin XLR Male (In)3-Pin XLR Female (Out)
Ground/Shield
Data Compliment (- signal)
Data True (+ signal)
Not Used
Not Used
Pin 1
Pin 2
Pin 3
Pin 1
Pin 2
Pin 3
Do Not Use
Do Not Use
ADJ Products, LLC - www.adj.com - Vizi CMY300 User Manual Page 10
Vizi CMY300 DMX Addressing
DMX ADDRESSING
All xtures should be given a DMX starting address when using a DMX controller, so the correct xture
responds to the correct control signal. This digital starting address is the channel number from which
the xture starts to “listen” to the digital control signal sent out from the DMX controller. The assignment
of this starting DMX address is achieved by setting the correct DMX address on the digital control
display on the xture.
You can set the same starting address for all xtures or a group of xtures, or set dierent addresses for each individual xture. Setting all xtures to the same DMX address will cause all xtures to react in the same way, in other words, changing the settings of one channel will aect all the xtures
simultaneously.
If you set each xture to a dierent DMX address, each unit will start to “listen” to the channel number you have set, based on the quantity of DMX channels of each xture. That means changing the settings of one channel will only aect the selected xture.
In the case of the Vizi CMY300, when in 24 Channel you should set the starting DMX address of the
rst unit to 1, the second unit to 25 (24 + 1), the third unit to 49 (25 + 24), and so on. (See chart below
for more details.)
Channelmode
24channels 1 25 49 73
26channels 1 27 53 79
38channels 1 39 77 115
Unit1
Address
Unit2
Address
Unit3
Address
Unit4
Address
ADJ Products, LLC - www.adj.com - Vizi CMY300 User Manual Page 11
Vizi CMY300 Control Panel and Connections
FrontviewRearview
3
2 4
1
1. WiFly Antenna
5
6
7 8
2. Service Port: USB Slot is used to upgrade the unit rmware.
3. LED:
POWER On PowerOn
DMX On DMXinputpresent
4. Display:Toshow the variousmenus and theselectedfunction.
5. Button: 
MENU Toenterintothe menu orleavethemenu
 UP To moveupinthemenu
 DOWN To movedowninthemenu
ENTER Toperformthedesiredfunctions
6. DMXinput/output: ForDMX512operation,use3/5‐pin XLR plug cabletolinktheunitstogether
7. Fuse(T10A): Protecttheunitfromdamage ofovercurrent.
8. PowerCable:Toconnecttothemain power supply ornext xture.
ADJ Products, LLC - www.adj.com - Vizi CMY300 User Manual Page 12
Vizi CMY300 24 Channel Mode (Basic Setting)
Channel Value Function
1 0 - 255 PAN MOVEMENT BY 540° 2 0 - 255 TILT MOVEMENT BY 270°
3 COLOR WHEEL 0 - 6 OPEN 7 - 12 RED 13 - 18 LIGHT GREEN
19 - 25 PINK
26 - 31 ORANGE
32 - 37 CTB
38 - 44 CTO 45 - 50 UV 51 - 56 GREEN
57 - 63 LIGHT BLUE
64 - 127 COLOR INDEXING
128 - 190 CLOCKWISE SCROLL FAST - SLOW
191 - 192 STOP
193 - 255 COUNTER-CLOCKWISE SCROLL SLOW - FAST
4 CYAN
0 - 255 0% - 100%
5 MAGENTA
0 - 255 0% - 100%
6 YELLOW
0 - 255 0% - 100% 7 ROTATING GOBOS (GOBO WHEEL 1)
0 - 7 OPEN
8 - 15 ROTATING GOBO 1 16 - 23 ROTATING GOBO 2 24 - 31 ROTATING GOBO 3 32 - 39 ROTATING GOBO 4 40 - 47 ROTATING GOBO 5 48 - 55 ROTATING GOBO 6 56 - 63 ROTATING GOBO 7 64 - 72 ROTATING GOBO 1 SHAKE 73 - 81 ROTATING GOBO 2 SHAKE 82 - 90 ROTATING GOBO 3 SHAKE 91 - 99 ROTATING GOBO 4 SHAKE 100 - 108 ROTATING GOBO 5 SHAKE 109 - 117 ROTATING GOBO 6 SHAKE 118 - 127 ROTATING GOBO 7 SHAKE 128 - 190 CLOCKWISE SCROLL FAST - SLOW
191 - 192 STOP
193 - 255 COUNTER-CLOCKWISE SCROLL SLOW - FAST
ADJ Products, LLC - www.adj.com - Vizi CMY300 User Manual Page 13
Vizi CMY300 24 Channel Mode (Basic Setting)
Channel Value Function
8 ROTATING GOBO INDEXING & GOBO ROTATION
0 - 127 GOBO INDEXING 0 - 360 128 - 189 CLOCKWISE ROTATION FAST - SLOW
190 - 192 STOP
193 - 255 COUNTER-CLOCKWISE ROTATION SLOW - FAST 9 FIXED GOBOS (GOBO WHEEL 2)
0 - 6 OPEN
7 - 12 GOBO 1 13 - 18 GOBO 2 19 - 25 GOBO 3 26 - 31 GOBO 4 32 - 37 GOBO 5 38 - 44 GOBO 6 45 - 50 GOBO 7 51 - 56 GOBO 8 57 - 63 GOBO 9 64 - 70 GOBO 1 SHAKE SLOW - FAST 71 - 77 GOBO 2 SHAKE SLOW - FAST 78 - 84 GOBO 3 SHAKE SLOW - FAST 85 - 91 GOBO 4 SHAKE SLOW - FAST 92 - 98 GOBO 5 SHAKE SLOW - FAST 99 - 105 GOBO 6 SHAKE SLOW - FAST 106 - 112 GOBO 7 SHAKE SLOW - FAST 113 - 119 GOBO 8 SHAKE SLOW - FAST 120 - 127 GOBO 9 SHAKE SLOW - FAST 128 - 190 CLOCKWISE WHEEL ROTATION FAST - SLOW
191 - 192 STOP
193 - 255 COUNTER-CLOCKWISE WHEEL ROTATION SLOW - FAST
10 PRISM 1 (LINEAR) 0 - 10 NO EFFECT 11 - 127 ON 128 - 255 MACRO 1 - 32 11 PRISM 1 ROTATION 0 - 127 PRISM INDEXING
128 - 190 CLOCKWISE ROTATION FAST - SLOW
191 - 192 NO ROTATION
193 - 255 COUNTER-CLOCKWISE ROTATION SLOW - FAST
12 PRISM 2 (3 FACET) 0 - 127 NO EFFECT 128 - 255 ON 13 PRISM 2 ROTATION 0 - 127 PRISM INDEXING
128 - 190 CLOCKWISE ROTATION FAST - SLOW
191 - 192 NO ROTATION
193 - 255 COUNTER-CLOCKWISE ROTATION SLOW - FAST
ADJ Products, LLC - www.adj.com - Vizi CMY300 User Manual Page 14