American DJ DJ 250HP User Manual

DJ Scan 250HP™ Introduction
Introduction: Congratulations and thank you for purchasing the DJ
®, one of the finest pieces of its kind
Customer Support: American DJ® provides a toll free customer sup-
port line, to provide set-up and installation help and to answer any question should you encounter problems during your set up or initial operation. You may also visit us on the web at www.americandj.com for any comments or suggestions. Toll free customer service hours are Monday through Friday 9:00 a.m. to 5:30 p.m. Pacific Standard Time. Voice: (800) 322-6337 Fax: (323) 582-2610 E-mail: support@americandj.com
To purchase parts online visit http://parts.americandj.com
Warning! To prevent or reduce the risk of electrical shock or fire, do
not expose this unit to rain or moisture.
Rev. 2/06
User Instructions
4295 Charter Street
Los Angeles, CA 90058
www.americandj.com
American DJ
Caution! There are no user serviceable parts inside this unit. Do not
attempt any repairs yourself, doing so will void your manufactures war ranty. In the unlikely event your unit may require service please contact American DJ® customer support.
Please recycle the shipping carton when ever possible
Improvements and changes in specifications and design to this manual and unit may be made at any time without prior notice.
.
HALOGEN LAMP WARNING!
This fixture is fitted with a halogen lamp which is highly susceptible to damage if improperly handled. Never touch the lamp with your bare fingers as the oil from your hands will shorten the lamp life. Never install, mount, or place this fixture in areas prone to heavy vibration. Also, never move the fixture until the lamp has had ample time to cool. Remember, lamps are not covered under warranty conditions.
©American DJ Supply® - www.americandj.com - DJ Scan 250HP™ User Manual Page 2
-
DJ Scan 250HP™ Safety Precautions
DJ Scan 250HP™ Quick Start
• Do not spill water or other liquids into or on to your unit.
• Be sure that the local power outlet match that of the required volt age for your unit.
• Do not attempt to operate this unit if the power cord has been frayed or broken. Please route your power cord out of the way of foot traffic.
• Do not attempt to remove or break off the ground prong from the electrical cord. This prong is used to reduce the risk of electrical shock and fire in case of an internal short.
• Disconnect
from main power before making any type of connection.
• Do not remove the top cover under any conditions. There are no user serviceable parts inside.
• Never plug this unit in to a dimmer pack
• Always be sure to mount this unit in an area that will allow proper ventilation. Allow about 6” (15cm) between this device and a wall.
• Do not attempt to operate this unit, if it becomes damaged in any way.
• Never operate this unit when it’s cover is removed.
• To reduce the risk of electrical shock or fire, do not expose this unit rain or moisture
• This unit is intended for indoor use only, use of this product out doors voids all warranties.
• During long periods of non-use, disconnect the unit’s main power.
• Always mount this unit in safe and stable matter.
• Power Cord Protection - Power cords should be routed so they are not likely to be walked on or pinched by items placed upon or against them, paying particular attention to cords at plugs, conve­ nience receptacles, and the point where they exit from the unit.
• Cleaning - Follow the directions on page 10.
• Heat -The unit should be situated away from heat sources such as radiators, heat registers, stoves, or other appliances (including amplifiers) that produce heat.
• The fixture should be serviced by qualified service personnel when: A. The power-supply cord or the plug has been damaged. B. Objects have fallen, or liquid has been spilled into the appliance. C. The appliance has been exposed to rain or water. D. The fixture does not appear to operate normally or exhibits a
marked change in performance.
Master/Slave Quick Start Stand Alone Mode
Connect up to four units together via XLR cables. The master unit will run the slaves to the masters built in programs and internal micro phone. Plug in all units. When the DJ Scan 250HP™ is first turned on, it will run through an internal self test where it resets all motors to their zero position. After the self test the units will react to sound, and fol low several built in programs.
DJ Scan 250HP™ Features
The DJ Scan 250HP™ features a bright 250 watt halogen bulb with a separate gobo and color wheel. The color wheel features seven brilliant colors plus white and the gobo wheel features 10 gobos plus a large spot. This fixture incorporates the use of high quality stepper motors for a more accurate mirror movement. Mirror move ment allows for a full 90 degree tilt (vertical) and a 45 degree pan (horizontal). An internal built in microphone allows the fixtures to run in Stand Alone mode so there is no need for an external controller. The DJ Scan 250HP™ may also be set-up to run in a Master-Slave mode when used in multiples, up to four units. When used in the Master-Slave mode, the unit will chase to several internal programs. The DJ Scan 250HP™ can also be controlled via a standard DMX controller such as the Elation
® Show Designer,™ or the Elation®
DMX Operator,™ giving the user independent control over the gobo and color wheel as well as the mirrors pan and tilt movements.
Note: The built in programs in the DJ Scan 250HP™ are so good you may never need a DMX controller.
• ZB-ELC10 24V/250W
• DMX-512 Compatible.
• Stepper motors for smooth movements.
• 7 colors plus white.
• 10 Gobos plus spot.
• Gobo Shake
• Master/Slave Operation
• Sound Active.
• Optional MINI/C controller, for blackout control.
• Optional Wireless MINI/C controller, for blackout control.
-
-
-
©American DJ Supply® - www.americandj.com - DJ Scan 250HP™ User Manual Page 4©American DJ Supply® - www.americandj.com - DJ Scan 250HP™ User Manual Page 3
1
2
3
1
2
3
DMX +
DMX
-
COMMON
DMX512 IN
CONNECTOR
3 PIN
DMX512 OUT
CONTROLLER
CONNECTOR
3 PIN
DJ Scan 250HP™ Set Up
POWER
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
1
2
3
Terminatio n re duces signal errors and avo ids signal tran smis sion problem s and interference. It is always advisable to connect a DMX terminal, (Resistance 120 Ohm 1/4 W) between PIN 2 (DMX-) and PIN 3 (DMX +) of the last fixture.
DJ Scan 250HP™ Set Up
Unpacking:
Every DJ Scan 250HP™ has been thoroughly tested and has been shipped in perfect operating condition, there is no assembly neces­sary. Carefully check the shipping carton for damage that may have occurred during shipping. If the carton appears to be damaged, care­fully inspect your unit for any damage and be sure all equipment nec­essary to operate the unit has arrived intact. In case damage has been found or parts are missing, please contact our toll free customer sup­port number for further instructions, please do not return the unit to your dealer.
Power Supply:
Before plugging your unit in be sure the source voltage in your area matches the required voltage for your American DJ® DJ Scan 250HP.™ The American DJ® DJ Scan 250HP™ is available in a 120v and 220v ver­sion. Because line voltage may vary from venue to venue, you should be sure to plug your unit into a matching wall outlet before attempting to operate you controller.
Data Cable (DMX Cable) Requirements:
Your controller and packs require a standard 3-pin XLR connector for DMX data input and DMX data output (Figure 1). If you are making your own cables be sure to use standard two conductor shielded cable (This cable may be purchased at almost all pro sound and lighting stores). Your cables should be made with a male and female XLR connector on either end of the cable. Also remember that DMX cable must be daisy chained and can not be “Y-d” or split.
Notice: Do not use the ground lug on the XLR connector. Do not con-
nect the cable’s shield conductor to the ground lug or allow the shield conductor to come in contact with the XLR’s outer casing. Grounding the shield could cause a short circuit and erratic behavior.
©American DJ Supply® - www.americandj.com - DJ Scan 250HP™ User Manual Page 5
XLR Male Socket
1 Ground
2 Cold
3 Hot
Figure 3
XLR Female Socket
2 Cold
1 Ground
3 Hot
XLR Pin Configuration
Pin 1 = Ground
Pin 2 = Data Compliment (negative)
Pin 3 = Data True (positive)
Figure 3
Notice: Be sure to follow figures two and three when making your own
cables.
Special Note: Line Termination.
When longer runs of cable are used, you may need to use a terminator on the last unit to avoid erratic behavior. A terminator is a 90-120 ohm 1/4 watt resistor which is connected between pins 2 and 3 of a male XLR connector (DATA - and DATA +). This unit is inserted in the female XLR connector of the last unit in your daisy chain to terminate the line. Using a cable terminator will decrease the possibilities of erratic behavior.
DJ Scan 250HP™ DMX Addressing
Figure 2
DMX is short for Digital Multiplex. This is a universal binary language used as a form of communication between intelligent fixtures. Each dipswitch represents a binary value.
Dipswitch 1 address equals 1 Dipswitch 2 address equals 2 Dipswitch 3 address equals 4 Dipswitch 4 address equals 8 Dipswitch 5 address equals 16 Dipswitch 6 address equals 32 Dipswitch 7 address equals 64 Dipswitch 8 address equals 128 Dipswitch 9 address equals 256
©American DJ Supply® - www.americandj.com - DJ Scan 250HP™ User Manual Page 6
Figure 4
DMX CHANNEL
2 8 32 128
ON
1 2 3 54 7 986
1 4 16 64 256
Loading...
+ 5 hidden pages