specications, diagrams, images, and instructions herein are subject to change without notice. ADJ Products, LLC logo and identifying product names and numbers herein are trademarks of ADJ Products, LLC. Copyright protection claimed includes all forms and matters of copyrightable materials and information now allowed by statutory or judicial law or hereinafter granted. Product names used in this document may be trademarks or registered trademarks of their respective companies and are hereby acknowledged. All non-ADJ Products, LLC brands and product names are trademarks or registered trademarks of their
respective companies.
ADJ Products, LLC and all aliated companies hereby dis­claim any and all liabilities for property, equipment, building, and electrical damages, injuries to any persons, and direct or indi­rect economic loss associated with the use or reliance of any information contained within this document, and/or as a result of the improper, unsafe, unsucient and negligent assembly, installation, rigging, and operation of this product.
2/17
User Instructions
Europe Energy Saving Notice Energy Saving Matters (EuP 2009/125/EC) Saving electric energy is a key to help protecting the enviroment. Please turn o all electrical products when they are not in use. To avoid power consumption in idle mode, disconnect all electrical equipment from power when not in use. Thank you!
7PZ IP Introduction
7PZ IP Features
Unpacking: Thank you for purchasing the 7PZ IP by ADJ Products, LLC. Every 7PZ IP has been thoroughly tested and has been shipped in perfect operating condition. Carefully check the shipping carton for damage that may have occurred during shipping. If the carton appears to be damaged, carefully inspect your xture for any damage and be sure all accessories necessary to operate the unit has arrived intact. In the case damage has been found or parts are missing, please contact our toll free customer support number for further instructions. Do not return this unit to your dealer without rst contacting customer sup-
port.
Introduction:
The 7PZ IP is an IP65 outdoor rated, DMX intelligent,
zooming, LED par fixture with ADJ’s WiFly TransCeiver with wireless DMX built-in. This xture can be used in a stand alone mode or con­nected in a Master/Slave conguration. This wash has seven operat­ing modes: 6 Color Change mode, 30 Color Change mode, Auto Fade mode, Auto Run mode, Manual mode, Static Color mode, and DMX
control mode.
Customer Support: ADJ Products, LLC provides a customer support line, to provide set up help and to answer any question should you encounter problems during your set up or initial operation. You may also visit us on the web at www.adj.com for any comments or sugges­tions. Service Hours are Monday through Friday 8:00 a.m. to 4:30 p.m. Pacic Standard Time. Voice: (800) 322-6337 Fax: (323) 582-2941 E-mail: support@AmericanDJ.com
Warning! To prevent or reduce the risk of electrical shock or re, do
not expose this unit to rain or moisture.
Caution! There are no user serviceable parts inside this unit. Do not
attempt any repairs yourself, doing so will void your manufactures war­ranty. In the unlikely event your unit may require service please contact ADJ Products, LLC.
PLEASE recycle the shipping carton when ever possible.
ADJ Products, LLC - www.adj.com - 7PZ IP User Manual Page 2
• Multi-Colors
• Electronic Dimming 0-100%
• 5-45 Degree Beam Angle
• DMX-512 protocol
• 3-Pin & 5-Pin DMX Connections
• 12 DMX Channel Modes
• Built-In ADJ’s WiFly EXR Wireless DMX Up to 2,500 feet/760M
• Seatronic IP Connections for DMX & Power
• powerCON TRUE1 AC In/Out Outlets
• Power Cord Daisy Chain (See page 37)
Incuded Accessories: 1 x powerCON TRUE1 power cable 1 x Scissor Yoke
7PZ IP Warranty Registration
The 7PZ IP carries a 2 year (730 Days) limited warranty. Please fill out the enclosed warranty card to validate your purchase. All returned service items whether under warranty or not, must be freight pre-paid and accompany a return authorization (R.A.) number. The R.A. number must be clearly written on the outside of the return package. A brief description of the problem as well as the R.A. number must also be written down on a piece of paper included in the shipping carton. If the unit is under warranty, you must provide a copy of your proof of purchase invoice. You may obtain a R.A. number by contacting our customer support team on our customer support number. All pack­ages returned to the service department not displaying a R.A. number on the outside of the package will be returned to the shipper.
7PZ IP Installation
The unit should be mounted using a mounting clamp (not provided), axing it to the mounting bracket that is provided with the unit. Always ensure that the unit is rmly xed to avoid vibration and slip­ping while operating. Always ensure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 times the unit’s weight. Also, always use a safety cable that can hold 12 times the weight of the unit when installing the xture. The equipment must be installed by a professional, and it must be installed in a place where it is out of the reach of people’s grasp.
ADJ Products, LLC - www.adj.com - 7PZ IP User Manual Page 3
7PZ IP Safety Precautions
environments and has been designed with an enclosure that effectively
protects the ingress (entry) of external foreign objects such as dust and
numbers define the degree of protection. The first digit (Foreign Bodies
fixture and the second digit (Water Protection) indicates the extent of
iers) to
7PZ IP IP Notice
• To reduce the risk of electrical shock or re, do not expose this unit rain or moisture
• Do not spill water or other liquids into or on to your unit.
• Do not attempt to operate this unit if the power cord has been frayed or broken. Do not attempt to remove or break o the ground prong from the electrical cord. This prong is used to reduce the risk of electrical shock and re in case of an internal short.
• Disconnect from main power before making any type of connection.
• Do not remove the cover under any conditions. There are no user serviceable parts inside.
• Never operate this unit when it’s cover is removed.
• Never plug this unit in to a dimmer pack
• Always be sure to mount this unit in an area that will allow proper ventilation. Allow about 6” (15cm) between this device and a wall.
• Do not attempt to operate this unit, if it becomes damaged.
• This unit is intended for indoor use only, use of this product out` doors voids all warranties.
• During long periods of non-use, disconnect the unit’s main power.
• Always mount this unit in safe and stable matter.
• Power-supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them, paying particular attention to the point they exit from the unit.
• Cleaning -The fixture should be cleaned only as recommended by t he manufacturer. See page 37 for cleaning details.
• Heat -The appliance should be situated away from heat sources such as radiators, heat registers, stoves, or other appliances (inclu­ d ing amplifiers) that produce heat.
• The fixture should be serviced by qualified service personnel when: A. The power-supply cord or the plug has been damaged. B. Objects have fallen, or liquid has been spilled into the appliance. C. The appliance has been exposed to rain or water. D. The appliance does not appear to operate normally or exhibits a marked change in performance.
CAUTION: This unit like any wireless device is highly susceptible to static electricity. Static electricity can severly damage the unit.
IP65 RATED
An IP rated lighting fixture is one, which is commonly installed in outdoor
water. The International Protection (IP) rating system is commonly expressed
as "IP" (Ingress Protection) followed by two numbers (i.e. IP65) where the
Protection) indicates the extent of protection against particles entering the
protection against water entering the fixture. An IP65 rated lighting fixture is
one, which has been designed and tested to protect against the ingress of
dust (6) and high-pressure water jets from any direction (5).
MARINE/COASTAL ENVIRONMENT INSTALLATIONS!
Please note although this fixture is IP rated, the fixture is NOT suitable for
marine and/or coastal environment installations. Installing this fixture in a
marine and/or coastal environment may cause corrosion and/or excessive
wear to the interior and/or exterior components of the fixture. Damages
and/or performance issues resulting from installation in a marine and/or
coastal environment will void the manufactures warranty and will NOT be
subject to any warranty claims and/or repairs.
Ensure ALL connections and end caps are properly sealed with a non-
conductive dielectric grease (available at most electrical suppl
prevent water ingress/condensation and/or corrosion.
OPTIONAL CORROSION- RESISTANT COATING
Optional Corrosion-Resistant Coatings may be available for this fixture.
Please consult your Elation Professional sales representative for details.
ADJ Products, LLC - www.adj.com - 7PZ IP User Manual Page 4
ADJ Products, LLC - www.adj.com - 7PZ IP User Manual Page 5
7PZ IP Set Up 7PZ IP Protective Valve
Power Supply: The ADJ 7PZ IP contains an automatic voltage
switch, which will auto sense the voltage when it is plugged into the power source. With this switch there is no need to worry about the cor­rect power voltage, this unit can be plugged in anywhere.
DMX-512: DMX is short for Digital Multiplex. This is a universal pro-
tocol used as a form of communication between intelligent fixtures and controllers. A DMX controller sends DMX data instructions from the controller to the fixture. DMX data is sent as serial data that trav­els from fixture to fixture via the DATA “IN” and DATA “OUT” XLR ter­minals located on all DMX fixtures (most controllers only have a DATA “OUT” terminal).
DMX Linking: DMX is a language allowing all makes and models of dierent manufactures to be linked together and operate from a single controller, as long as all xtures and the controller are DMX compli­ant. To ensure proper DMX data transmission, when using several DMX fixtures try to use the shortest cable path possible. The order in which fixtures are connected in a DMX line does not influence the DMX addressing. For example; a fixture assigned a DMX address of 1 may be placed anywhere in a DMX line, at the beginning, at the end, or anywhere in the middle. When a fixture is assigned a DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that unit, no matter where it is located in the DMX chain.
ADJ Products, LLC - www.adj.com - 7PZ IP User Manual Page 6
DMX Cable Requirements: The 7PZ IP can be controlled via DMX-
512 protocol. The 7PZ IP has 12 DMX channel modes, please see pages 9-21 for the dierent modes. The DMX address is set on the back panel of the 7PZ IP.
Cable Requirements: This xture powered by powerCON TRUE1 power cables. These cables are specically designed to maintain the integrity of the IP rating. When using this xture outdoors be sure to ONLY use the ADJ cables that have been manufactured to meet the IP rating.
“First” DMX Cables - Special DMX “First” cable may be purchased from ADJ to provide a means of data communication with standard DMX xtures for indoor use. These cables will come with the IP rated connec­tor on one end and either a 3-pin XLR male or female connector on the other depending on model. Be sure to only use these cables for inter­grading this xture in a standard DMX chain.
ADJ Products, LLC - www.adj.com - 7PZ IP User Manual Page 7
7PZ IP Set Up
POWER
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
“First” Power Cable – A special power “First” cable is included with every xture. This cable is used to provide power to your xture. This cable comes with the IP rated twist lock connector on one end and a standard Edison 3-prong, grounded prong on the other end. Be sure to only use this cable for power distribution and never attempt to connect this cable to the DMX lines.
You can chain multiple xtures together through serial linking. Using the IP rated signal cables provided through ADJ (part# TRU113). Always be sure to daisy-chain your in and out data connections, never split or “Y” your DMX connections unless you are using an approved DMX splitter such as the ADJ WiFly D6 Branch or the original D6 Branch (Both not IP rated).
Special Note: Line Termination.
When longer runs of cable are
used, you may need to use a terminator on the last unit to avoid erratic behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is con­nected between pins 2 and 3 of a male XLR connector (DATA + and DATA -). This unit is inserted in the female XLR connector of the last unit in your daisy chain to terminate the line. Using a cable terminator (ADJ part number Z-DMX/T) will decrease the possibilities of erratic behavior.
5-Pin XLR DMX Connectors.
Termination reduces signal errors and
1
avoids signal transmission problems
3
and interference. It is always advisable
2
to connect a DMX terminal, (Resistance 120 Ohm 1/4 W) between PIN 2 (DMX-) and PIN 3 (DMX +) of the last fixture.
Some manufactures use 5-pin DMX-
512 data cables for DATA transmission in place of 3-pin. 5-pin DMX xtures may be implemented in a 3-pin DMX line. When inserting stan­dard 5-pin data cables in to a 3-pin line a cable adaptor must be used, these adaptors are readily available at most electric stores. The chart below details a proper cable conversion.
3-Pin XLR to 5-Pin XLR Conversion
Conductor 5-Pin XLR Male (In)3-Pin XLR Female (Out)
Ground/Shield
Data Compliment (- signal)
Data True (+ signal)
Not Used
Not Used
Pin 1
Pin 2
Pin 3
Pin 1
Pin 2
Pin 3
Do Not Use
Do Not Use
7PZ IP 4 Channel - HSI
Channel Value Function
1 HUE
0 - 255 0% - 100% 2 SATURATION 0 - 255 0% - 100% 3 INTENSITY 0 - 255 0% - 100% 4 ZOOM 0 - 255 NARROW - WIDE
7PZ IP 5 Channel - RGBW
Channel Value Function
1 RED
0 - 255 0% - 100% 2 GREEN 0 - 255 0% - 100% 3 BLUE 0 - 255 0% - 100% 4 WHITE 0 - 255 0% - 100% 5 ZOOM 0 - 255 NARROW - WIDE
ADJ Products, LLC - www.adj.com - 7PZ IP User Manual Page 8
ADJ Products, LLC - www.adj.com - 7PZ IP User Manual Page 9
7PZ IP 5 Channel - HSI + Zoom
Channel Value Function
7PZ IP 7 Channel - sRGBWI
Channel Value Function
1 HUE
0 - 255 0% - 100% 2 SATURATION 0 - 255 0% - 100% 3 INTENSITY 0 - 255 0% - 100% 4 ZOOM 0 - 255 NARROW - WIDE 5 DIMMER CURVES 0 - 20 STANDARD 21 - 40 STAGE 41 - 60 TV 61 - 80 ARCHITECTURAL 81 - 100 THEATER 101 - 255 DEFAULT TO UNIT CURVE SETTING
7PZ IP 6 Channel - RGBW + Zoom
Channel Value Function
1 RED
0 - 255 0% - 100% 2 GREEN 0 - 255 0% - 100% 3 BLUE 0 - 255 0% - 100% 4 WHITE 0 - 255 0% - 100% 5 MASTER DIMMER 0 - 255 0% - 100% 6 ZOOM 0 - 255 NARROW - WIDE
1 SHUTTER/STROBE 0 - 31 LED OFF 32 - 63 LED ON 64 - 95 STROBING SLOW - FAST 96 - 127 LED ON 128 - 159 STROBE PULSE SLOW - FAST 160 - 191 LED ON 192 - 223 RANDOM STROBE SLOW - FAST 224 - 255 LED ON 2 RED 0 - 255 0% - 100% 3 GREEN 0 - 255 0% - 100% 4 BLUE 0 - 255 0% - 100% 5 WHITE 0 - 255 0% - 100% 6 INTENSITY 0 - 255 0% - 100% 7 ZOOM 0 - 255 NARROW - WIDE
ADJ Products, LLC - www.adj.com - 7PZ IP User Manual Page 11ADJ Products, LLC - www.adj.com - 7PZ IP User Manual Page 10
7PZ IP 7 Channel - RGBW
Channel Value Function
7PZ IP 8 Channel - RGBW
Channel Value Function
1 RED
0 - 255 0% - 100% 2 GREEN 0 - 255 0% - 100% 3 BLUE 0 - 255 0% - 100% 4 WHITE 0 - 255 0% - 100% 5 MASTER DIMMER 0 - 255 0% - 100% 6 MASTER DIMMER (FINE) 0 - 255 0% - 100% 7 ZOOM 0 - 255 NARROW - WIDE
1 RED 0 - 255 0% - 100% 2 GREEN 0 - 255 0% - 100% 3 BLUE 0 - 255 0% - 100% 4 WHITE 0 - 255 0% - 100% 5 SHUTTER/STROBE 0 - 31 LED OFF 32 - 63 LED ON 64 - 95 STROBING SLOW - FAST 96 - 127 LED ON 128 - 159 STROBE PULSE SLOW - FAST 160 - 191 LED ON 192 - 223 RANDOM STROBE SLOW - FAST 224 - 255 LED ON 6 MASTER DIMMER 0 - 255 0% - 100% 7 MASTER DIMMER (FINE) 0 - 255 0% - 100% 8 ZOOM 0 - 255 NARROW - WIDE