MEET STATE AND FEDERAL GUIDELINES

Helping meet CDC/VFC Guidelines for Medication Storage

Pharmacy

Refrigerators and Freezers

American BioTech Supply offers a full line of medical grade refrigerators and freezers designed to meet current federal, state andvaccine manufacturers’ guidelines forvaccine storage.

V. 1.5_08012018

PEACE OF MIND

PROUDLY EXCEEDING REGULATORY GUIDELINES

According to the Center for Disease Control, failure to adhere to recommended specifications for storage and handling of immunobiologics can reduce or destroy their potency, resulting in inadequate or no immune response in the recipient.

Maintenance of vaccine quality is the shared responsibility of all handlers of vaccines from the time a vaccine is manufactured until it’s administered.

The Immunization Action Coalition states that all vaccines should be stored in a refrigerator or freezer that is designed specifically for the storage of biologics or, alternatively, in a separate dedicated unit. A dorm-style combination refrigeratorfreezer unit with just one exterior door has been shown to be unacceptable no matter where the vaccine was placed inside the unit. Stand-alone refrigerator or

freezer units are best for storage needs. Accurate and uniform temperature in a refrigerator plays a key role in ensuring the life of vaccines, reagents and other biologicals. Research has shown that minor variances in temperature such as those in a household refrigerator can compromise the effectiveness of your biologicals, risking up to thousands of dollars in valuable contents.

It i s e s t i m at e d t h at $20 m i l l i o n i s wa s t e d

a n n u a l ly f r o m p o o r

r e f r i g e r at i o n , a n d u p t o 35% o f va c c i n e s

a r e e f f e c t e d b y i m p r o p e r s t o r a g e .

Today it is more important than ever to protect your vaccines, your customers, and your institution from inadequate vaccine storage.

ASSISTIN G WIT H COMPLIANCE

Understanding CDC Guidlines

Key Messages:

Vaccine Storage Equipment

CDC recommends stand-alone units or pharmacy grade/purpose-built units

CDC does not recommend (and VFC does not allow) storage of any vaccine in a dormitory-style or bar-style refrigerator under any circumstances

Set refrigerator temperature mid-range to achieve an average of 41 F (5 C)

The freezer should maintain temperatures between -58 F and +5 F (-50 C and -15 C)

Temperature Monitoring Equipment

CDC recommends (and VFC requires) using only calibrated temperature monitoring devices with a Certificate of Calibration

Calibration testing should be performed every one to two years

CDC recommends having a back-up thermometer

CDC recommends using digital data loggers for continuous temperature monitoring

ABT-WiFi1-DL

ABT-WiFi2-DL

CDC recommends using digital data loggers for continuous temperature monitoring.

Staff should be trained and understand how to set up, read, and analyze temperature data provided by the data logger.

The temperature monitoring device should be near where vaccines are stored.

ABT-CDC-DL1

EXCERPTSTAKEN DIRECTLY FROM CDC VACCINE STORAGE & HANDLINGTOOLKIT

2

www.americanbiotechsupply.com

3

American Biotech Supply PH-ABT-HC-UCFS-0504G, PH-ABT-HC-UCFS-0104G, PH-ABT-HC-RFC7, PH-ABT-HC-RFC12G, PH-ABT-HC-UCBI-0420A User Manual

Key Features

Microprocessor temperature controller

Digital temperature display with sample simulated probe

Audible and visual high and low temperature alarms

Remote alarm contacts (excluding PH-ABT-HC-UCBI-0420A)

Adjustable operating temperature range:

Refrigerator: 36°F – 46°F (2°C -8°C) Freezer: 4°F – -13°F (-15°C - -25°C)

Refrigerator/Freezer freestanding thermometer with 3 year certificate of calibration, with min/ max memory, °F/°C switchable

Vaccine storage power cord warning label

Keyed door lock

Magnetic door gasket for positive seal

Leveling legs

Probe access port (3/8”)

High density urethane foam cabinet and door insulation

Hydrocarbon natural refrigerant (R600a)

Pharmacy refrigerator/freezer toolkit and temperature logs

Pyxis®, Omnicell® and AcuDose RX® compatible

Defrost:

Refrigerator: Cycle defrost Freezer: Auto & Manual defrost available

ADA compliant units available

Two year parts and labor warranty

UL/C-UL listed

4 www.americanbiotechsupply.com

BUILT-IN

UNDERCOUNTER REFRIGERATORS AND FREEZERS

Front Ventilation design for built-in applications between pharmacy cabinetry

The Pharmacy Premier Built-In Undercounter Refrigerators & Freezers take a large step forward in performance from past solid door general purpose units; offering a digital temperature display and alarm module coupled with a microprocessor temperature controller.

An interior fan driven, forced draft air circulation system provides excellent temperature uniformity and rapid temperature recovery after door openings. (Refrigerators

Only)

Rear wall evaporator cover.

PH-ABT-HC-UCBI-0404

PH-ABT-HC-UCBI-0420SS

PH-ABT-HC-UCBI-0404G

Pharmacy Premier Built-In

Undercounter Refrigerators & Freezers

Sample Simulated Temperature

Display & Alarms

Front ventilation design allows units to be built completely into casework

*DISCLAIMER: Auto defrost freezers incorporate an electric heater installed on the evaporator that assists in the removal of the frost and ice. Although the heater helps speed up the frost and ice removal, it can raise the

PH-ABT-HC-UCBI-0420A temperatures within the freezer. These air temperature spikes can be harmful to some

medical and laboratory products.

Now Featuring!

Refrigerator/Freezer freestanding thermometer with3yearcertificateof calibration

Environmentally friendly, natural hydrocarbon (HC) refrigerants which vastly reduce global-warming potential while meeting new EPA/SNAP mandates

P r e m i e r R e f r i g e r a to r

 

Model

Cu. Ft.

 

Defrost

Doors

Shelves

W”

D”

 

H”

 

RL

 

H.P.

 

Amps

 

 

 

 

PH-ABT-HC-UCBI-0404

4.6

 

Cycle

1 Solid

2 Adj/1 Fixed

23 3/4

24 1/2

33 3/8

 

R600a

1/8

1.74

 

 

 

 

PH-ABT-HC-UCBI-0404-LH

4.6

 

Cycle

1 Solid LH

2 Adj/1 Fixed

23 3/4

24 1/2

33 3/8

 

R600a

1/8

1.74

 

 

 

 

PH-ABT-HC-UCBI-0404G

4.6

 

Cycle

1 Glass

2 Adj/1 Fixed

23 3/4

24 1/2

33 3/8

 

R600a

1/8

1.74

 

 

 

 

PH-ABT-HC-UCBI-0404G-LH

4.6

 

Cycle

1 Glass LH

2 Adj/1 Fixed

23 3/4

24 1/2

33 3/8

 

R600a

1/8

1.74

 

 

 

 

PH-ABT-HC-UCBI-0404G-ADA

4.6

 

Cycle

1 Glass

2 Adj/1 Fixed

23 3/4

25 1/2

31 15/16

 

R600a

1/8

1.74

 

 

 

 

PH-ABT-HC-UCBI-0404G-ADA-LH

4.6

 

Cycle

1 Glass LH

2 Adj/1 Fixed

23 3/4

25 1/2

31 15/16

 

R600a

1/8

1.74

 

 

 

 

PH-ABT-HC-UCBI-0404SS

4.5

 

Cycle

1 Solid

2 Adj/1 Fixed

23 3/4

24 1/2

33 3/8

 

R600a

1/8

1.74

 

 

 

 

PH-ABT-HC-UCBI-0404SS-LH

4.5

 

Cycle

1 Solid LH

2 Adj/1 Fixed

23 3/4

24 1/2

33 3/8

 

R600a

1/8

1.74

 

 

 

 

P r e m i e r F r e e z e r

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model

 

Cu. Ft.

Defrost

 

Doors

Shelves

W”

D”

 

H”

 

RL

 

H.P.

 

Amps

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PH-ABT-HC-UCBI-0420

 

4.2

Manual

 

1 Solid

2 Fixed

23 3/4

24 1/2

 

33 3/8

 

R600a

 

1/8

 

1.5

 

 

 

 

PH-ABT-HC-UCBI-0420-LH

 

4.2

Manual

 

1 Solid LH

2 Fixed

23 3/4

24 1/2

 

33 3/8

 

R600a

 

1/8

 

1.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PH-ABT-HC-UCBI-0420-ADA

 

4.2

Manual

 

1 Solid

2 Fixed

23 3/4

25 1/2

 

31 15/16

 

R600a

 

1/8

 

1.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PH-ABT-HC-UCBI-0420-ADA-LH

 

4.2

Manual

 

1 Solid LH

2 Fixed

23 3/4

25 1/2

 

31 15/16

 

R600a

 

1/8

 

1.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PH-ABT-HC-UCBI-0420SS

 

4.2

Manual

 

1 Solid

2 Fixed

23 3/4

24 1/2

 

33 3/8

 

R600a

 

1/8

 

1.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PH-ABT-HC-UCBI-0420SS-LH

 

4.2

Manual

 

1 Solid LH

2 Fixed

23 3/4

24 1/2

 

33 3/8

 

R600a

 

1/8

 

1.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*PH-ABT-HC-UCBI-0420A

 

4.2

 

Auto

 

1 Solid

3 Adj

23 3/4

24 1/2

 

33 3/8

 

R290

 

1/8

 

1.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*PH-ABT-HC-UCBI-0420A-LH

 

4.2

 

Auto

 

1 Solid LH

3 Adj

23 3/4

24 1/2

 

33 3/8

 

R290

 

1/8

 

1.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

Pharmacy Premier Freestanding

Undercounter Refrigerators & Freezers

Standard features include a microprocessor temperature controller and display for superior temperature control, verification, and recovery.

PH-ABT-HC-UCFS-0204

P r e m i e r R e f r i g e r a to r

Digital temperature controller allows for very precise temperature maintenance

Certain models available in either glass or solid door

*DISCLAIMER: Auto defrost freezers incorporate an electric heater installed on the evaporator that assists in the removal of the frost and ice. Although the heater helps speed up the frost and ice removal, it can raise the temperatures within the freezer. These air temperature spikes can be harmful to some medical and laboratory products.

Now Featuring!

Refrigerator/Freezer freestanding thermometer with3yearcertificateof calibration

Environmentally friendly, natural hydrocarbon (HC) refrigerants which vastly reduce global-warming potential while meeting new EPA/SNAP mandates

 

Model

Cu. Ft.

Defrost

Doors

Shelves

W”

D”

H”

RL

H.P.

Amps

 

 

 

 

 

 

 

 

 

 

 

 

 

PH-ABT-HC-UCFS-0104

1

Cycle

1 Solid

2 Adj

17 1/4

19 1/4

21 1/4

R600a

1/8

0.9

 

PH-ABT-HC-UCFS-0104-LH

1

Cycle

1 Solid LH

2 Adj

17 1/4

19 1/4

21 1/4

R600a

1/8

0.9

 

PH-ABT-HC-UCFS-0104G

1

Cycle

1 Glass

2 Adj

17 1/4

19 1/4

21 1/4

R600a

1/8

0.9

 

PH-ABT-HC-UCFS-0104G-LH

1

Cycle

1 Glass LH

2 Adj

17 1/4

19 1/4

21 1/4

R600a

1/8

0.9

 

PH-ABT-HC-UCFS-0204

2.5

Cycle

1 Solid

4 Adj

17 3/4

19 1/2

28 7/8

R600a

1/8

0.9

 

PH-ABT-HC-UCFS-0204G

2.5

Cycle

1 Glass

4 Adj

17 3/4

19 1/2

28 7/8

R600a

1/8

0.9

 

PH-ABT-HC-UCFS-0504G

5.2

Cycle

1 Glass

3 Adj

23 3/4

24

32 1/8

R600a

1/6

1.74

 

P r e m i e r F r e e z e r

 

 

 

 

 

 

 

 

 

 

 

Model

Cu. Ft.

Defrost

Doors

Shelves

W”

D”

H”

RL

H.P.

Amps

 

 

 

 

 

 

 

 

 

 

 

 

 

PH-ABT-HC-UCFS-0120

1.7

Manual

1 Solid

2 Adj

23 3/4

24

20 3/8

R600a

1/8

1

 

 

 

 

 

 

 

 

 

 

 

 

 

PH-ABT-HC-UCFS-0120-LH

1.7

Manual

1 Solid LH

2 Adj

23 3/4

24

20 3/8

R600a

1/8

1

 

 

 

 

 

 

 

 

 

 

 

 

 

*PH-ABT-HC-UCFS-0120A

1.3

Auto

1 Solid

2 Adj

23 3/4

24

20 3/8

R600a

1/8

1

 

 

 

 

 

 

 

 

 

 

 

 

 

*PH-ABT-HC-UCFS-0120A-LH

1.3

Auto

1 Solid LH

2 Adj

23 3/4

24

20 3/8

R600a

1/8

1

 

 

 

 

 

 

 

 

 

 

 

 

6

www.americanbiotechsupply.com

 

 

 

 

 

 

 

 

 

 

Freestanding

UNDERCOUNTER & COUNTER TOP REFRIGERATORS AND FREEZERS

The ideal choice for pharmacies with undercounter and counter top applications with adequate space for ventilation

PH-ABT-HC-UCFS-0504G

An interior fan driven, forced draft air circulation system provides excellent temperature uniformity and rapid temperature recovery after door openings. (Refrigerators Only)

PH-ABT-HC-UCFS-0104

PH-ABT-HC-UCFS-0104G

Requires at least 4” of clearance on each side for adequate ventilation

Key Features

Microprocessor temperature controller

Digital temperature display with sample simulated probe

Audible and visual high and low temperature alarms

Remote alarm contacts

Adjustable operating temperature range:

Refrigerator: 36°F – 46°F (2°C -8°C) Freezer: 4°F – -13°F (-15°C - -25°C)

Refrigerator/Freezer freestanding thermometer with 3 year certificate of calibration, with min/max memory, °F/°C switchable

Vaccine storage power cord warning label

Keyed door lock

Back wall evaporator cover

Forced draft circulation (refrigerators only)

Magnetic door gasket for positive seal

Leveling legs

Probe access port (3/8”)

Powder coat exterior

High density urethane foam cabinet and door insulation

Hydrocarbon natural refrigerant (R600a)

Pharmacy refrigerator/freezer toolkit and temperature logs

Pyxis®, Omnicell® and AcuDose RX® compatible

Note: This unit must have 4” clearance on sides and back for adequate ventilation

Defrost:

Refrigerator: Cycle defrost Freezer: Auto & Manual defrost available

ADA compliant units available

Two year parts and labor warranty

UL/C-UL listed

7