IMPORTANT SAFETY INSTRUCTIONS
When using this electronic device, basic precautions should always be taken, including the following:
1. Read all instructions before using the product.
2. Do not use this product near water (e.g., near a bathtub, washbowl, kitchen sink, in a
wet basement or near a swimming pool etc).
4. This product, in combination with loudspeakers may be capable of producing sound
levels that could cause permanent hearing loss. Do not operate for a long period of time at a high volume level or at a level that is uncomfortable. If you experience any hearing loss or ringing in the ears, you should consult with otorhinolaryngologists. The product should be positioned so that proper ventilation is maintained.
5. The product should be located away from heat sources such as radiators, heat vents, or
other devices (including amplifiers) that produce heat.
6. The product should be connected to a power supply that is described in the operating
instructions or are marked on the product. Replace the fuse only with one of the specified type, size and correct rating.
7. The power supply cord should be undamaged and never share an outlet or extension
cord with other devices so that the outlet or extension cord's power rating is exceeded. Never leave device plugged into the outlet when it is not being used for a long period of time.
8. Care should be taken so that objects do not fall into, and liquids would not be spilled
through, the enclosure's openings.
9. The product should be serviced by qualified service personnel if:
The power supply cord or the plug has been damaged.Objects have fallen into or liquid has been spilled on the product.The product has been exposed to rain.The product has been dropped or the enclosure damaged.
10. There are some areas with high voltage inside, to reduce the risk of electric shock do not
remove cover of the amplifier. The cover should be removed by the qualified personnel only.
No user serviceable parts inside.
CONTENTS:
Before you start Introductions 4 Features 4
Operation Front panel 5 Rear panel 5 Function description 6 Output terminal 7
Controls and connectors Connectors 9 Cable wiring examples 9
Specifications General specifications 12
Introduction
MA mixing amplifiers for rack mount or stand alone. It is a widely used mixing amplifier designed for different applications for public address and paging systems, useful for background music systems. Universal structure of the units, audio signal mixing possibilities, various inputs and outputs have wide application in simple installations. No need of professional installation assistance. Shop, bar or restaurant personnel can manage the installation of these mixing amplifiers by itself. Can be used as a component of voice evacuation or public address system. Line, microphone inputs, phantom power supply, different connectors, preamp out and direct power amplifier stage input connectors expands the fields of application of these high quality mixing amplifiers.
Features
Four balanced XLR mic/line inputs.First XLR input – priority input.Switchable phantom power on each XLR input.AUX in and REC out connectors.DC 24V input connector for external power supply.Tone control.Output level indicator.
Front Panel
1. XLR inputs level control
2. AUX input level control
3. Tone control
4. Master volume
5. Output level indicator
6. Power indicator
7. ON/OFF button
Rear Panel
1. Power connector and AC fuse
2. Output and +24V DC terminal
3. Stereo RCA REC output
4. Stereo RCA AUX input
5. AUX input gain selector
6. Balanced XLR inputs
7. Connector for external equipment
8. Gain and phantom power selector.
Functions description
Front panel:
1. XLR INPUTS LEVEL CONTROL
These rotary knobs are for adjusting volume level of the XLR inputs. First four inputs can be used as balanced line level as well as microphone level inputs. The phantom power can be activated for these inputs separately in rear panel. The input gain selector is located in the rear panel too.
2. AUX INPUTS LEVEL CONTROL
These rotary knobs are for adjusting volume level of the AUX input.
3. TONE CONTROL
The separate tone controls provide attenuation of bass and treble response. The flat position is obtained when the knobs are set to middle position. Turn bass control knob (BASS) and treble tone control knob (TREBLE), respectively, clockwise to raise tone level by approximately +10 dB; turn counterclockwise to lower tone level by approximately -10 dB.
4. MASTER VOLUME
This potentiometer is designed to adjust audio level in the main output.
5. OUTPUT LEVEL INDICATION
This is level indicator of the master output. If the red LED indicator starts lighting continuously the output is distorted. In this case, decrease the sound volume by master volume control.
6. POWER INDICATOR
This LED indicates status of the power. The LED lights up if the amplifier is powered.
7. POWER SWITCH
Use this switch to power on or off the amplifier. The LED in the front panel lights up if the amplifier is powered.
Rear panel:
1. POWER CONNECTOR AND AC FUSE
Power connector is designed for main powers connecting to amplifier. This connector is combined with fuse holder and 2.5A 250V fuse for MA 120 and 1.6A 250V fuse for MA 60 amplifiers.
2. OUTPUT AND +24V DC TERMINAL
24V DC terminal is designed to power up the amplifier when the main power is unavailable. Use only DC 24V power supply or batteries and take attention to polarity during the wiring. Output terminal is designed to connect audio line to amplifier. There are available 4 types of output: low impedance 4
Ω output, 25 V, 70 V and 100 V outputs for audio line. Please find some connection examples below in this user manual.
3. REC OUTPUT
This is line level stereo RCA output to connect audio recording equipment.
4. AUX INPUT
Stereo RCA input with selectable sensitivity. There is a possibility to connect the line level audio, input gain can be adjusted by using AUX input gain selector.
5. AUX INPUT GAIN SELECTOR
This selector is designed to adjust the gain for the AUX input. There are available three gain settings:
-8 dBu, -12dBu and -18dBu.
6. BALANCED XLR INPUTS
These balanced XLR inputs are universal, the gain (MIC or LINE) of these inputs are selectable by switch located near the input in the rear panel. If the 24V PHANTOM power is activated the input gain sets to microphone level automatically. Please note: Phantom power is switchable on each XLR input separately. First balanced XLR input have a priority against other inputs.
7. CONNECTOR FOR EXTERNAL EQUIPMENT
PREAMPLIFIER OUTPUT: This is line level output directly from device preamplifier. Preamplifier output and amplifier input are designed to insert signal processor such as equalizer. DIRECT AMPLIFIER INPUT: This is line level input directly to device power amplifier. 1W 8Ω and 0dB 600Ω are designed for music on hold.
8. GAIN AND PHANTOM POWER SELECTOR.
This selector is designed to adjust the gain for the balanced XLR inputs and select 24V phantom power if
condenser microphones are used.
9. PRIORITY
Input 1 is a priority input. Priority is fixed and cannot be switched off.
Output terminal
Each of the amplifier channels can run only one output configuration at the same time. Operating amplifiers using 4 ohm and 70 or 100 volt concurrently may cause damage to the amplifier or connected speakers.
There is possibility to connect external power supply, external battery etc. Please find the connection example.
Connectors
TS connector
TRS connector
XLR male connector XLR female connector
RCA connector
Cable wiring examples
Cable to balanced input from balanced output. TRS connectors.
Cable to unbalanced input from balanced output. TRS and TS connectors.
Cable to balanced input from unbalanced output. TS and TRS connectors.
Cable to unbalanced input from unbalanced output. TS connectors.
Cable to balanced input from balanced output. XLR connectors.
Cable to unbalanced input from balanced output. XLR and TS connectors.
Cable to balanced input from unbalanced output. TS and XLR connectors.
Cable to balanced input from balanced output. TRS and XLR connectors.
RCA cable.
Cable to unbalanced input from RCA output. RCA and TS connectors.
Cable to balanced input from RCA output. RCA and XLR connectors.
Cable to balanced input from RCA output. RCA and TRS connectors.
Cable to RCA input from balanced output. RCA and XLR connectors.
Cable to RCA input from balanced output. RCA and TRS connectors.
General specifications
MA 60
MA 120
Power supply
AC 230 V, 50 Hz or 24 V DC
Fuses
Fuse for AC power: 1.6A, 250V,
5.2x20mm.
Fuse for DC power: 8A, 250V, 
5.2x20mm.
Fuse for AC power: 2.5A, 250V, 
5.2x20mm.
Fuse for DC power: 15A, 250V, 
5.2x20m.
Output power
60 W
120W
AC power consumption
160 W
320 W
Total harmonic distortions
< 2 %
Priority
Input 1
Input sensitivity
Line 0 dBu
MIC -63 dBu
AUX -17 dBu
S/N ratio
70 dBu
Frequency response
50 Hz – 15 kHz
Indicators
Power indicator, output level meter
Output
4Ω - (15.5V)
25V - (10.5Ω )
70V - (83 Ω),
100V - (170 Ω)
4Ω - (22V) 25V - (5.2 Ω) 70V - (42 Ω),
100V - (830 Ω)
TAPE OUT - 4.7K ohms, 0 dBu
MOH OUT - 8 ohms 1W/ 600 ohms, 1V