IMPORTANT: READ AND SAVE THESE INSTRUCTIONS.
FOR RESIDENTIAL USE ONLY.
IMPORTANT : LIRE ET CONSERVER CES INSTRUCTIONS.
POUR UTILISATION RÉSIDENTIELLE UNIQUEMENT.
LI30ZC/W10487239D
Installation Instructions and Use & Care Guide
CAISSE DE HOTTE POUR CUISINIÈRE
DE 30" (76,2 CM)
Instructions d’installation et Guide d’utilisation et d’entretien
Table of Contents/Table des matières............................................................................. 2
TABLE OF CONTENTS
You can be killed or seriously injured if you don't immediately
You
can be killed or seriously injured if you don't
follow
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.”
These words mean:
follow instructions.
instructions.
DANGER
WARNING
TABLE DES MATIÈRES
RANGE HOOD SAFETY .................................................................2
State of California Proposition 65 Warnings:
WARNING: This product contains one or more chemicals known to the State of California to cause cancer.
WARNING: This product contains one or more chemicals known to the State of California to cause birth defects or other
reproductive harm.
IMPORTANT SAFETY INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK, OR INJURY TO PERSONS, OBSERVE THE
FOLLOWING:
■ Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the
manufacturer.
■ Before servicing or cleaning the unit, switch power off at
service panel and lock the service disconnecting means to
prevent power from being switched on accidentally. When
the service disconnecting means cannot be locked,
securely fasten a prominent warning device, such as a tag,
to the service panel.
■ Installation work and electrical wiring must be done by
qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction.
■ Do not operate any fan with a damaged cord or plug.
Discard fan or return to an authorized service facility for
examination and/or repair.
■ Sufficient air is needed for proper combustion and
exhausting of gases through the flue (chimney) of fuel
burning equipment to prevent backdrafting. Follow the
heating equipment manufacturer's guideline and safety
standards such as those published by the National Fire
Protection Association (NFPA), the American Society for
Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
■ When cutting or drilling into wall or ceiling; do not damage
electrical wiring and other utilities.
■ Ducted fans must always be vented outdoors.CAUTION: For general ventilating use only. Do not use
to exhaust hazardous or explosive materials and vapors.
CAUTION: To reduce risk of fire and to properly exhaust
air, be sure to duct air outside - do not vent exhaust air into
spaces within walls or ceilings, attics or into crawl spaces,
or garages.
WARNING: TO REDUCE THE RISK OF FIRE, USE ONLY
METAL DUCTWORK.
WARNING: TO REDUCE THE RISK OF A RANGE TOP
GREASE FIRE:
■ Never leave surface units unattended at high settings.
Boilovers cause smoking and greasy spillovers that may
ignite. Heat oils slowly on low or medium settings.
■ Always turn hood ON when cooking at high heat or when
■ Clean ventilating fans frequently. Grease should not be
allowed to accumulate on fan or filter.
■ Use proper pan size. Always use cookware appropriate for
the size of the surface element.
WARNING: TO REDUCE THE RISK OF INJURY TO
PERSONS IN THE EVENT OF A RANGE TOP GREASE
FIRE, OBSERVE THE FOLLOWING:
a
■ SMOTHER FLAMES with a close fitting lid, cookie sheet, or
metal tray, then turn off the burner. BE CAREFUL TO
PREVENT BURNS. If the flames do not go out
immediately, EVACUATE AND CALL THE FIRE
DEPARTMENT.
■ NEVER PICK UP A FLAMING PAN - you may be burned.
■ DO NOT USE WATER, including wet dishcloths or towels -
a violent steam explosion will result.
■ Use an extinguisher ONLY if:
– You know you have a class ABC extinguisher, and you
already know how to operate it.
– The fire is small and contained in the area where it
started.
– The fire department is being called.
– You can fight the fire with your back to an exit.
a
Based on "Kitchen Fire Safety Tips" published by NFPA.
■ WARNING: To reduce the risk of fire or electrical shock,
do not use this fan with any solid-state speed control
device.
3
INSTALLATION REQUIREMENTS
†®TORX is a registered trademark of Saturn Fasteners, Inc.
Tools and Parts
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
Tools needed
■ Level
■ Drill
■ ¹⁄₈" (3 mm) drill bit
■ Pencil
■ Pliers
■ Tape measure or ruler
■ Caulking gun and weatherproof caulking compound
■ Phillips screwdriver
■ Flat-blade screwdriver
■ Saber or keyhole saw
■ Vent clamps
■ Metal snips
Parts needed
■ 6" (15.2 cm) round metal vent system
For vented installations, you will need:
■ 1 wall or roof cap
For non-vented (recirculating) installations, you will also
need:
■ Recirculation Kit Part Number W10490330. See the
“Assistance or Service” section to order.
Parts supplied
Remove parts from packages. Check that all parts are included.
■ Damper
■ Hardware package. Includes:
Installation Instructions and Use and Care Guide
2 mounting brackets
6 spacers
10 - 4.5 x 13 mm wood screws
2 - 4.2 x 15 mm machine screws
4 - 3.5 x 9.5 mm flat-head sheet metal screws
8 - 4.2 x 19 mm sheet metal screws
2 - 3.5 x 9.5 mm sheet metal screws
1 - 30" x 12" (76.2 x 30.5 cm) face panel
2 metal grease filters
®†
T10 TORX
8 - metal washers
8 - plastic washers
adapter
Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
Have a qualified technician install the range hood. It is the
installer’s responsibility to comply with installation clearances
specified on the model/serial rating plate. The model/serial rating
plate is located inside the liner behind the filter on the left wall of
the range hood.
Range hood location should be away from strong draft areas,
such as windows, doors, and strong heating vents.
Cabinet opening dimensions that are shown must be used. Given
dimensions provide minimum clearance. Consult your cooktop/
range manufacturer installation instructions before making any
cutouts.
This range hood is recommended for use with cooktops with a
maximum total rating of 65,000 Btus or less.
Grounded electrical outlet is required. See “Electrical
Requirements” section.
The range hood is factory set for vented installations through the
roof or wall. For non-vented (recirculating) installations see “NonVented (recirculating) Installation Through the Soffit/Cabinet” in
the “Prepare Location” section. Recirculation Kit Part Number
W10490330 is available from your dealer or an authorized parts
distributor.
All openings in ceiling and wall where range hood will be installed
must be sealed.
For Mobile Home Installations
The installation of this range hood must conform to the
Manufactured Home Construction Safety Standards, Title 24
CFR, Part 328 (formerly the Federal Standard for Mobile Home
Construction and Safety, title 24, HUD, Part 280) or when such
standard is not applicable, the standard for Manufactured Home
Installation 1982 (Manufactured Home Sites, Communities and
Setups) ANSI A225.1/NFPA 501A, or latest edition, or with local
codes.
4
Product Dimensions
A
I
H
G
F
E
D
C
B
F
A
B
C
D
E
A.
³⁄₈
" (1.0 cm)
B. 30" (76.2 cm) or
36" (91.4 cm)
C. 26" (66.1 cm)
D. 2" (5.1 cm) or
5" (12.7 cm)
E. 10
³⁄₄
" (27.4 cm)
F.
³⁄₄
" (1.9 cm)
G. 11
17
H. 9
I. 13
¹⁄₈
⁷⁄₈
" (30.2 cm) or
⁷⁄₈
" (45.4 cm)
" (23.1 cm)
⁵⁄₈
" (33.7 cm)
*NOTE: 30" (76.2 cm) cabinet width can be 12" (30.5 cm) deep or
Cabinet Dimensions
18" (45.7 cm) deep cabinets.
36" (91.4 cm) cabinet width requires 18" (45.7 cm) deep
cabinets.
For 18" (45.7 cm) deep cabinets, an optional “Face Panel Rear
Extension” (30" [76.2 cm]) or “Face Panel” (36" [91.4 cm]) must
be purchased separately. See “Assistance and Service” section
to order.
Venting Requirements
(vented models only)
■ Vent system must terminate to the outside, except for non-
vented (recirculating) installations.
■ Do not terminate the vent system in an attic or other enclosed
A. 12" (30.5 cm) min. upper
cabinet height
B. 30" (76.2 cm) or 36" (91.4 cm)
cabinet opening width*
C. 24" (61 cm) min. 36" (91.4 cm)
suggested max. bottom of
cabinet to cooking surface
D. 12" (30.5 cm) cabinet depth*
E. 15" (38.1 cm) min. clearance
upper cabinet to countertop
F. 36" (91.4 cm) base cabinet
height
area.
■ Do not use a 4" (10.2 cm) laundry-type wall cap.
■ Use metal vent only. A rigid metal vent is recommended.
Plastic or metal foil vent is not recommended.
■ The length of the vent system and number of elbows should
be kept to a minimum to provide efficient performance.
For the most efficient and quiet operation:
■ Use no more than three 90° elbows.
■ Make sure there is a minimum of 24" (61.0 cm) of straight
vent between the elbows if more than 1 elbow is used.
■ Do not install 2 elbows together.
■ The vent system must have a damper.
■ Use clamps to seal all joints in the vent system.
■ Use caulking to seal exterior wall or roof opening around the
■ The size of the vent should be uniform.
cap.
5
Cold weather installations
A
B
A
B
90˚ elbow
3 ft
(0.93 m)
6 ft (1.8 m)
Wall cap
A
A
B
B
C
D
D
E
E
F
F
G
G
I
H
An additional back draft damper should be installed to minimize
backward cold air flow and a thermal break should be installed to
minimize conduction of outside temperatures as part of the vent
system. The damper should be on the cold air side of the thermal
break.
The break should be as close as possible to where the vent
system enters the heated portion of the house.
Makeup air
Local building codes may require the use of makeup air systems
when using ventilation systems with greater than specified CFM
of air movement. The specified CFM varies from locale to locale.
Consult your HVAC professional for specific requirements in your
area.
Venting Methods
This range hood is factory set for venting through the roof or
through the wall.
The vent system needed for installation is not included.
A 6" (15.2 cm) round vent system is recommended.
Roof VentingWall Venting
Example vent system - 6" (15.2 cm)
Maximum Length= 35 ft (10.7 m)
1 - 90° elbow= 5 ft (1.5 m)
1 - wall cap= 0 ft (0 m)
9 ft (2.8 m) straight= 9 ft (2.8 m)
System length= 14 ft (4.3 m)
Non-Vented (recirculating) Installations Through the
Soffit/Cabinet
If it is not possible to vent cooking fumes and vapors to the
outside, the range hood can be used in the non-vented
(recirculating) version, using a charcoal filter. Charcoal Filter Kit
Part Number W10272068 is available from the dealer or an
authorized parts distributor.
Through CabinetThrough Soffit
A. 6" (15.2 cm) vent through
the roof
B. Roof cap
A. 6" (15.2 cm) vent through
the wall
B. Wall cap
Calculate Vent System Length
The recommended vent system is 6" (15.2 cm) round vent with a
maximum length of 35 ft (10.7 m). For the best performance, use
no more than three 90° elbows.
To calculate the length of the system, add the equivalent feet
(meters) for each of the vent pieces used in the system.
Vent Piece6" (15.2 cm)
45° elbow2.5 ft
(0.8 m)
90° elbow5.0 ft
(1.5 m)
6
A. Ceiling
B. Vent cover
C. Soffit
D. 6" (15.2 cm) vent
E. Range hood
F. C a b i ne t
G. Wall
H. 12" (30.5 cm) min. cabinet
height
I. 17" (43.2 cm) min. vent cover
height
NOTE: 12" (30.5 cm) high cabinets without a soffit may allow the
6" (15.2 cm) vent and vent cover to be seen.
Electrical Requirements
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
33⁷⁄₁₆" (85 cm)
GROUNDING INSTRUCTIONS
SAVE THESE INSTRUCTIONS
■
For a grounded, cord-connected range hood:
This range hood must be grounded. In the event of an
electrical short circuit, grounding reduces the risk of electric
shock by providing an escape wire for the electric current.
This range hood is equipped with a cord having a grounding
wire with a grounding plug. The plug must be plugged into
an outlet that is properly installed and grounded.
WARNING:Improper grounding can result in a risk of
electric shock.
Consult a qualified electrician if the grounding instructions
are not completely understood, or if doubt exists as to
whether the range hood is properly grounded.
Do not use an extension cord. If the power supply cord is too
short, have a qualified electrician install an outlet near the
range hood.
IMPORTANT: The range hood must be electrically grounded in
accordance with local codes and ordinances, or in the absence
of local codes, with the National Electrical Code, ANSI/NFPA 70
(latest edition) or Canadian Electrical Code, CSA C22.1
No. 0-M91 (latest edition).
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrical installer determine that
the ground path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
CSA International
8501 East Pleasant Valley Road
Cleveland, Ohio 44131-5575
■ A 120 volt, 60 Hz, AC only, 15- or 20-amp, fused electrical
circuit is required. A time-delay fuse or circuit breaker is also
recommended. It is recommended that a separate circuit
serving only this range hood be provided.
■ This range hood is equipped with a power supply cord having
a 3 prong grounding plug.
■ To minimize possible shock hazard, the cord must be
plugged into a mating, 3 prong, grounding-type outlet,
grounded in accordance with local codes and ordinances. If a
mating outlet is not available, it is the personal responsibility
and obligation of the customer to have the properly grounded
outlet installed by a qualified electrician.
■ The grounded 3 prong outlet is to be located inside the
cabinet above the range hood at a maximum distance of
33⁷⁄₁₆" (85.0 cm) from where the power cord exits the hood.
The grounded 3 prong outlet must be accessible after
installation of the range hood. See illustration.
7
INSTALLATION INSTRUCTIONS
WARNING
Excessive Weight Hazard
Use two or more people to move and install
range hood.
Failure to do so can result in back or other injury.
A
B
C
D
E
D
A
B*
C
A
B
C
Prepare Location
■ It is recommended that the vent system be installed before
the range hood is installed.
■ Before making cutouts, make sure there is proper clearance
within the ceiling or wall for vent fittings.
■ Making the cutout to the bottom of the cabinet may be easier
to do prior to mounting the cabinet to the wall.
1. Disconnect power.
2. Determine which venting method to use: roof, wall, or non-
vented.
3. Select a flat surface for assembling the range hood. Place
covering over that surface.
4. Using 2 or more people, lift range hood onto covered surface.
Range Hood Cabinet Cutout
1. Use a saber saw or keyhole saw to cut out the cabinet
bottom inside the cabinet frame.
NOTE: Frameless type cabinets require ¾" (1.9 cm) front lip
in the cabinet bottom. A ¾" (1.9 cm) thick filler strip (not
supplied) may be required for some types of cabinets. (See
Step 3 in the “Install Range Hood” section.)
Venting Outside Through the Roof
Measure and mark the lines as shown. Use a saber saw or
keyhole saw to cut an opening through the top of the cabinet
and the roof for the vent.
Go to Step 3.
A. Cutout
B. 6¼" (15.9 cm)*
C. 7
³⁄₄
" (19.7 cm) centerline to cabinet front
D. Centerline
*NOTE: For 12" (30.5 cm) high cabinets, a 6¼" deep x 8" wide
(14.6 cm x 20.3 cm) rectangular opening in the cabinet top is
required for damper transition clearance.
Venting Outside Through the Wall
A. Bottom of cabinet cutout
B. Bottom must be cut flush to the inside walls of the cabinet.
C. 10
⁷⁄₈
" (27.6 cm) min. from the inside of the cabinet front face
D.
³⁄₄
" (1.9 cm) thick front face required for cabinet bottom.
E. Front of cabinet
2. Complete cabinet preparation following the instructions for
your type of venting. Determine venting cutout locations and
cut out vent openings in the cabinets, walls and/or soffit.
8
Install the 6" (15.2 cm) vent transition to the top of the range
hood liner using two 3.5 x 9.5 mm screws. Assemble the vent
duct that you will use over the 6" (15.2 cm) vent transition.
Measure from the bottom of the range hood liner to the
horizontal centerline of the vent opening (A).
A. Measurement A
B. Horizontal centerline of vent opening
C. Range hood liner
Remove the vent duct from the range hood liner.
Transfer measurement A to the cabinet back wall. Measure
B
A
C
A
B
D
A
B*
C
from the underside of the cabinet. Mark the cutout as shown.
Use a saber saw or keyhole saw to cut a round opening
through the back of the cabinet and the exterior wall for the
vent.
Go to Step 3.
Measure and mark the centerline location for the cutout in the
cabinet top. Use a saber saw or keyhole saw to cut an
opening for the vent.
A. Measurement A
B. Centerline
C. 6¼" (15.9 cm) round cutout
Non-Vented (recirculating) Installation Through the
Soffit/Cabinet
Measure and mark the centerline of the cabinet to the soffit
above.
Measure from the bottom of the cabinet to the centerline of
the where the vent will come through the soffit. Mark the
location and use a saber saw or keyhole saw to cut a 5¾"
(14.6 cm) hole for the vent cover.
A. Vent cover
B. Centerline
A. Cutout
B. *See chart below.
C. 7
³⁄₄
" (19.7 cm) centerline to cabinet front
D. Centerline
Cabinet HeightHole Shape and Size
12" (30.5 cm)A 6¼" deep x 8" wide (15.9 cm x 20.3 cm)
rectangular opening in the cabinet top is
required for damper transition clearance.
15" (38.1 cm)
cabinet or soffit
A 6¼" (15.9 cm) diameter round opening is
required.
installation
18" (45.7 cm) or
24" (61.0 cm)
A 5¾" (14.6 cm) diameter round opening is
required.
For non-vented (recirculating) installations only, the range
hood can be vented indoors through the top of the cabinet.
For non-vented (recirculating) installations, charcoal filters are
necessary. See the “Range Hood Care” section for
instructions on installing charcoal filters.
The Recirculation Kit Part Number W10490330 must be used.
9
Complete Preparation
A
B
C
D
A
B
C
D
WARNING
Excessive Weight Hazard
Use two or more people to move and install
range hood.
Failure to do so can result in back or other injury.
A
B
C
D
B
A
3. If not yet attached, install the 6" (15.2 cm) vent transition the
top of the range hood liner using two 3.5 x 9.5 mm screws.
4. Locate side mounting bracket flush to the bottom of the
cabinet side and against the inside of the front cabinet face.
Orient the bracket depending on the width of your cabinet as
depicted in the diagrams below. Drill ¹⁄₈" (3 mm) pilot holes in
6 places, attach a bracket using three 4.5 x 13 mm screws to
each side of the cabinet, and tighten. Additional washers in
hardware package are supplied as spacers for cabinet walls
thinner than ½" (13 mm).
Bracket Orientation for 30" (76.2 cm) Cabinet
Install Range Hood
1. Using 2 or more people, lift the hood liner into its mounted
location. Attach with four 4.2 x 19 mm screws into the slotted
openings. Do not tighten screws.
A. 30" (76.2 cm) cabinet
B. Screws - 4.5 x 13 mm (6)
C. Washers (optional)
D. Mounting bracket (2) (position for 30" [76.2 cm] cabinet)
Bracket Orientation for 36" (91.4 cm) cabinet
A. 36" (91.4 cm) cabinet
B. Screws - 4.5 x 13 mm (6)
C. Washers (optional)
D. Mounting bracket (2) (position for 36" [91.4 cm] cabinet)
A. Cabinet
B. Hood liner canopy assembly
2. If needed, insert spacers between each side of the canopy
and the mounting plate to space and center the canopy in the
cabinet. Align the bottom of the canopy with the bottom of
the cabinet. Install four 4.2 x 19 mm screws into the round
mounting plate openings and tighten all (8) mounting screws.
3. (For some installations):
A filler strip may be required for some cabinets.
Install a filler strip and secure with two 4.5 x 13 mm screws
from inside the front of the hood liner assembly.
C. Screws - 4.2 x 19 mm (8)
D. Spacer - optional
5. Install the vent system according to the method needed. Use
caulking to seal the exterior wall or roof opening.
10
A. Screws - 4.5 x 13 mm
B. Filler strip