Amana TSI25VW-P1308102WW, TSI25VL-P1308102WL, TSI25VE-P1308102WE Owner’s Manual

Amana Technical Information--Refrigerator
TSI25V P1308102W
Due to a possibility of personal injuryor property damage, always contact an authorized technician for servicing
or repair of this refrigerator.
Refer to Service Manual RS1100000 for installation, operating, disassembly, ice maker, testing, and
troubleshooting information.
Refer to Parts Manual RP1100056 for parts information.
I CAUTION
I WARNING
To avoid risk of electrical shock, personal injury,or death, disconnect power to refrigerator before servicing,
unless testing requires power. Wires removed during disassembly must be replaced on proper terminals to insure correct earthing and polarization.
Model TSI25V Capacity 24.5 cuft
Electrical 115 VAC 60 Hz
requirements 15 Amps
separate circuit
Refrigerant type R134a
Width 35.625" without side
extrusions Depth 32.655"
without handle
includes door extrusions
Height 68.295" including top hinge cap
t
No Load Performance Controls In Normal Position
Kw/24 hr +10%
Ambient °F
Ambient °F
April1999 1 RTl100035 Rev. 0
65° 90° 110 °
1,2 1.9 2.8
T-I Outlet T-2 inlet +3°F
±3OF
65° 90 ° 65° 90°
-9.5 -12.2 -16.7 -12.
Percent Run Time Cycles/24 hr Refdgerator Center
+10% _ Compartment Food
Avera_le Temperature +3°F
65 ° 90" lm10° 65 _ 90 ° 110 ° 65 ° 90° 110 °
22.1 33,5 50.7 37.9 38.3 30. 35.7 41.8 41,2.
Temperature Relationshi ) Test Chart
T-3 Suction Line
+7OF
65° gO°
65.9 90.
Average Total Suction Pressure Pressure
Wattage ±10% :L2 PSIG :t:5PSIG
65° 90° 65 ° 90° 65° 90 °
190. 204. 1. 2. 87. 135.
Freezer Compartment
Food Average
Temperature :P.3°F
65° 90° 110 °
I 0.6 0.9 -0.3
Head
Component Specifications
[ WARNING I
To avoid risk of electrical shook, personal injury, or death, disconnect power to oven before servicing, unless testing requires it.
Illustration
_0282803
38931604
12049711
_0161072
10428508
B215050 ___
Component Test Procedure
Bulb Colt 115/125 VAC
Capacitor, compressor run Volt 220 VAC
Compressor
2._1, damper
Hatt 40 wars
_,apacitance 15 Mfd + 10%
-5%
Type Fan cooled, R134a refrigerant
BTUH 970 BTUH
Volt 115 VAC, 60 Hz Watt 176 watts
Current
Lock rotor 21.3 amps Full load 1.6 amps
Resistance
Run windings 2.60 ohms Start windings 4.35 ohms
Settings Closingtemperatures if1 43"F
#4 30°F
#7 16°F
_r_, freezer tembemture
Settings Temperatures #1 - in 15.1°F
#1 - out 6.0°F
#4 - in 6.5°F #4 - Out -4.0°F
#7 - in 1.9°F
#7 -out -9.5°F
Driermostbe changedevery time the systemisoponedfor testingor compressor
rep/acemant.
Desiccant
10991110 Heater, evaporator Volt 115 VAC
_ Wattage 505 ±5% watts
10884501 Motor, condenser Volt 115 VAC, 60 Hz
Resistance 29 +5% ohms
Rotation (facing end opposite Clockwise
RPM 1300 RPM Watt 10.0 watts
shaft)
Current 0.15 amps Resistance 220 ±10% ohms
(20) 5 x 12 4AXH - 7 M>S> -Grams
RTl100035 Rev. 0 2 April 1999