Amana TEP340TQ1, TEP315TW1, TES355MQ5, TES356TD1, TES355MB5 Installation Instructions Manual

...
INSTALLATIONINSTRUCTIONS
30" (76 CM) FREESTANDINGELECTRICRANGES
TableofContents
RANGE SAFETY ............................................................................. 1
INSTALLATION REQUIREMENTS ................................................ 2
Tools and Parts ............................................................................ 2
Location Requirements ................................................................ 2
Electrical Requirements ............................................................... 3
INSTALLATION INSTRUCTIONS .................................................. 4
Unpack Range ............................................................................. 4
Install Anti-Tip Bracket ................................................................. 5
Electrical Connection ................................................................... 6
Verify Anti-Tip Bracket Location .................................................. 9
Level Range.................................................................................. 9
Complete Installation ................................................................. 10
ANTI-TIP BRACKET TEMPLATE ............................................... 11
RANGESAFETY
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING."
These words mean:
You can be killed or seriously injured if you don't immediately
follow instructions.
You can be killed or seriously injured if you don't follow instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.
A child or adult can tip the range and be killed.
Connect anti-tip bracket to rear range foot, Reconnect the anti-tip bracket, if the range is moved.
I Tip Over Hazard
Failure to follow these instructions can result in death or serious burns to children and adults.
iMPORTANT:
Save for local electrical inspector's use.
W10141166A
INSTALLATIONREQUIREMENTS
Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed
here.
Tools needed
Tape measure %" drive ratchet
Flat-blade screwdriver 1A"nut driver
Level %" and %6" nut driver
Hammer 1/8"(3.2 mm) drill bit (for
Hand or electric drill wood floors)
Wrench or pliers 3/16"(4.8 mm) carbide-tipped
Marker or pencil concrete/ceramic floors)
Masking tape
Parts supplied
Check that all parts are included.
masonry drill bit (for
A
oc@ equ ss m®n s
IMPORTANT: Observe all governing cedes and ordinances.
It is the instalbr's responsibility to comply with installation clearances specified on the model/serial rating plate. The model/serial rating plate is located on the left side frame behind the storage drawer panel,
The range should be located for convenient use in the kitchen.
To eliminate the risk of burns or fire by reaching over heated surface units, cabinet storage space located above the surface units should be avoided. If cabinet storage is to be provided, the risk can be reduced by installing a range hood that projects horizontally a minimum of 5" (12.7 cm) beyond
the bottom of the cabinets.
Cabinet opening dimensions that are shown must be used. Given dimensions are minimum clearances.
The floor anti-tip bracket must be installed. To install the anti- tip bracket shipped with the range, see "Install Anti-Tip
Bracket" section.
Grounded electrical supply is required. See "Electrical Requirements" section.
IMPORTANT: Toavoid damage to your cabinets, check with your builder or cabinet supplier to make sure that the materials used will not discolor, delaminate or sustain other damage. This oven has been designed in accordance with the requirements of UL and CSA International and complies with the maximum allowable wood cabinet temperatures of 194° (90°C).
A. Anti-tip bracket B. Plastic anchors (2) C. #10 x l _" screws (2)
Anti-tip brackets must be securely mounted to subfloor. Thickness of flooring may require longer screws to anchor bracket to subfloor. Longer screws are available from your
local hardware store.
Parts needed If using a power supply cord kit:
A UL listed power supply cord kit marked for use with ranges. The cord should be rated at 250 volts minimum, 40 amps or 50 amps that is marked for use with nominal 1%" (3.5 cm) diameter connection opening and must end in ring terminals or open-end spade terminals with upturned ends.
A UL listed strain relief.
Check local codes. Check existing electrical supply. See "Electrical Requirements" section.
All electrical connections should be made by a licensed, qualified electrical installer.
Mobile Home - Additional Installation Requirements
The installation of this range must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD Part 280). When such standard is not applicable, use the Standard for Manufactured Home
Installations, ANSI A225.1/NFPA 501A or local codes.
Mobile home installations require:
When this range is installed in a mobile home, it must be secured to the floor during transit. Any method of securing the range is adequate as long as it conforms to the standards
listed above.
Four-wire power supply cord or cable must be used in a mobile home installation. The appliance wiring will need to be
revised. See "Electrical Connection" section.
Product Dimensions
A
\
E
A. 27%" (68.9 cm) depth with handle
28%" (71.6 cm) depth with handle (KitchenAid models only)
B. 46%" (119.1 cm) overafl height
46" (116.8 cm) overall height (KitchenAid models only) C. 36" (91.4 cm) cooktop height D. 29%" (75.9 cm) width
E.24_sA6'' (63.0 cm) depth F. Model/serial rating plate (located on the left side frame behind
storage drawer panel)
Cabinet Dimensions
Cabinet opening dimensions shown are for 25" (64.0 cm) countertop depth, 24" (61.0 cm) base cabinet depth and
36" (91.4 cm) countertop height. If installing a range hood or microwave hood combination above
the range, follow the range hood or microwave hood combination installation instructions for dimensional clearances above the
cooktop surface. A freestanding range may be installed next to combustible walls
with zero clearance.
A. 13" (33.0 cm) max. upper cabinet depth B. 30" (76.2 cm) min. opening width C. For minimum clearance to top of cooktop, see NOTE*. D. 30" (76.2 cm) min. opening width
E.Outlet - 8" (20.3 cm) to 22" (55.9 cm) from either cabinet,
5_A'' (14.0 cm) max. from floor
E %" (2.2 cm) min. required between cutout and cabinet door or
hinge.
*NOTE: 24" (61.0 cm) minimum when bottom of wood or metal
cabinet is protected by not less than V4"(0.64 cm) flame
retardant millboard covered with not less than No. 28 MSG
sheet steel, 0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper.
30" (76.2 cm) minimum clearance between the top of the cooking platform and the bottom of an unprotected wood or
metal cabinet.
_,÷__.,;_ _> __ _ _ _ _ _ _!¸_
If codes permit and a separate ground wire is used, it is recommended that a qualified electrical installer determine that the ground path and wire gauge are in accordance with local
codes. If codes permit and a separate ground wire is used, it is
recommended that a qualified electrician determine that the ground path is adequate.
Do not use an extension cord. Be sure that the electrical connection and wire size are adequate
and in conformance with the National Electrical Code, ANSI/ NFPA 70-latest edition and all local codes and ordinances.
A copy of the above code standards can be obtained from: National Fire Protection Association
One Batterymarch Park Quincy, MA 02269.
WARNING: Improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check with a
qualified electrician or service technician if you are in doubt as to whether the appliance is properly grounded. Do not modify the power supply cord plug. If itwill not fit the outlet, have a proper outlet installed by a qualified electrician.
Electrical Connection
To properly install your range, you must determine the type of electrical connection you will be using and follow the instructions provided for it here.
Range must be connected to the proper electrical voltage and frequency as specified on the model/serial number rating plate. The model/serial number rating plate is located on the oven frame behind the storage drawer panel. Refer to the figures in the "Product Dimensions" section of the "Location Requirements" section.
This range is manufactured with the neutral terminal connected to the cabinet. Use a 3-wire, UL listed, 40- or 50-amp power supply cord (pigtail) (see Range Rating chart below). If local codes do not permit ground through the neutral, use a 4-wire power supply cord rated at 250 volts, 40 or 50 amps and investigated for use with ranges.
Range Rating* Specified Rating of
Power Supply Cord Kit
and Circuit Protection
120/240 Volts 120/208 Volts Amps
8.8 - 16.5 KW 7,8 - 12.5 KW 40 or 50**
16.6 - 22.5 KW 12.6 - 18.5 KW 50
If connecting to a 4-wire system: This range is manufactured with the ground connected to the
cabinet. The ground must be revised so the green ground wire of the 4-wire power supply cord is connected to the cabinet. See
"Electrical Connection." Grounding through the neutral conductor is prohibited for new
branch-circuit installations (1996 NEC); mobile homes; and recreational vehicles, or an area where local codes prohibit grounding through the neutral conductor.
When a 4-wire receptacle of NEMA Type 14-50R is used, a matching UL listed, 4-wire, 250-volt, 40- or 50-amp, range power supply cord (pigtail) must be used. This cord contains 4 copper conductors with ring terminals or open-end spade terminals with upturned ends, terminating in a NEMA Type 14-50R plug on the supply end.
The fourth (grounding) conductor must be identified by a green or green/yellow cover and the neutral conductor by a white cover. Cord should be Type SRD or SRDT with a UL listed strain relief and be at least 4 ft (1.22 m) long.
*The NEC calculated load is less than the total connected load
listed on the model/serial rating plate.
**If connecting to a 50-amp circuit, use a 50-amp rated cord with
kit, For 50-amp rated cord kits, use kits that specify use with a nominal 1%" (34,9 mm) diameter connection opening.
A time-delay fuse or circuit breaker is recommended. The range can be connected directly to the fused disconnect
(or circuit breaker box) through flexible or nonmetallic sheathed, copper or aluminum cable. See "Electrical
Connection."
Allow 2 to 3 ft (61.0 cm to 91.4 cm) of slack in the line so that the range can be moved if servicing is ever necessary.
A UL listed conduit connector must be provided at each end of the power supply cable (at the range and at the junction box).
Wire sizes and connections must conform with the rating of the range.
The wiring diagram is located on the back of the range or inside the storage drawer in a clear plastic bag.
INSTALLATIONINSTRUCTIONS
4-wire receptacle (14-50R)
The minimum conductor sized for the copper 4-wire power cord are:
40-amp circuit 2 No.-8 conductors
1 No.-10 white neutral 1 No.-8 green grounding
If connecting to a 3-wire system: Local codes may permit the use of a UL listed, 3-wire, 250-volt,
40- or 50-amp range power supply cord (pigtail). This cord contains 3 copper conductors with ring terminals or open-end spade terminals with upturned ends, terminating in a NEMA Type 10-50P plug on the supply end. Connectors on the appliance end must be provided at the point the power supply cord enters the
appliance. This uses a 3-wire receptacle of NEMA Type 10-50R.
3-wire receptacle (10-50R)
Excessive Weight Hazard
Use two or more people to move and install range. Failure to do so can result in back or other injury.
1. Remove shipping materials, tape and protective film from range. Remove oven racks and parts package from inside
oven.
Unpc:ck
2. Do not remove the shipping base at this time.
A. Shipping base
Loading...