Amana NGD7300WW Dimension Guide

Amana NGD7300WW Dimension Guide

 

 

Gas Dryer

 

 

PRODUCT MODEL NUMBERS

 

 

 

NGD7300W

 

 

 

DRYER DIMENSIONS

 

 

 

Front view:

Side view:

29"

Door open view:

 

 

27"

 

 

 

(686 mm)

(736 mm)

 

481/8"

 

 

 

471/8"

(1238 mm)

 

 

 

 

 

 

 

(1197 mm)

 

 

Left or

 

 

 

 

right side

 

 

35

3/8"

exhaust

 

 

(899 mm)

 

 

 

1"

(25 mm) 6 7/8"

(174 mm)

31/2"

(89 mm)

1 5/8"

(41 mm)

Back view:

Closet Installation (stacked washer and dryer):

61/4"

 

 

 

(159 mm)

 

6"

 

 

 

(152 mm)

 

Electric

 

3"

 

 

 

(76 mm)

48 in.2

 

 

 

 

 

71"

(310 cm2)

 

 

(1803 mm)

 

281/8"

 

 

 

(715 mm)

 

 

 

1

51/2"

 

24 in.2

3 /2"

(140 mm)

3"

(155 cm2)

(89 mm)

 

 

 

 

(76 mm)

 

 

1"

1"

 

 

(25 mm)

 

 

(25 mm)

 

 

14"

 

 

 

(358 mm)

Cabinet installation (dryer only):

 

NOTE: Most installations require a minimum 5" (102 mm) clearance behind the dryer for the exhaust vent with elbow. See “Venting

Requirements”. 7" (178 mm)

Custom under counter installation (dryer only):

 

18"

 

(460 mm)

39" min.

 

 

(990 mm)

 

 

1"

4"

 

(25 mm)

(102 mm)

 

 

 

1"

 

 

(25 mm)

 

 

NOTE: Some models not recommended for

 

1"

1"

(25 mm)

undercounter installation.

 

 

(25 mm)

 

Closet installation (dryer only):

34" recommended

3"

 

(76 mm)

 

(864 mm)

 

48 in.2

18" min.

 

(310 cm2)

 

 

(457 mm)

 

 

 

 

 

24 in.2

4"

 

3"

(155 cm2)

 

 

(102 mm)

 

(76 mm)

 

 

1"

 

 

1"

(25 mm)

 

 

 

 

(25 mm)

 

 

 

Spacing for recessed area or closet installation

All dimensions show recommended spacing allowed, with tested spacing of 0" (0 mm) clearance on sides and rear.

■■ Additional spacing should be considered for ease of installation and servicing.

■■ Additional clearances might be required for wall, door, and floor moldings.

■■ Additional spacing should be considered on all sides of the dryer to reduce noise transfer.

■■ For closet installation, with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent ventilitation openings are acceptable.

■■ Companion appliance spacing should also be considered.

■■ No other fuel-burning appliance may be installed in the same

closet as the dryer.

W10443045B

02/2012

INSTALLATION REQUIREMENTS

GAS SUPPLY REQUIREMENTS

Gas supply: This dryer is equipped for use with Natural gas. Dryer can be converted to L.P. gas. When rigid pipe is used it should be 1/2" IPS. When acceptable to the gas supplier and local codes, 3/8" approved tubing may be used for lengths under 20 ft (6.1 m). For lengths over 20 ft (6.1 m), larger tubing should be used. Pipe-joint compounds resistant to the action of L.P. gas must be used. An individual manual shutoff valve must be installed within 6 ft (1.8 m) of the dryer in accordance with the National Fuel Gas Code ANSI Z223.1.

ELECTRICAL REQUIREMENTS

A 120-volt, 60 Hz, AC-only, 15 or 20 amp fused electrical supply is required. A time-delay fuse or circuit breaker and a separate circuit are recommended.

WATER (STEAM MODELS ONLY) REQUIREMENTS

The dryer must be connected to the cold water faucet using new inlet hoses. Do not use old hoses. Do not overtighten. Damage to the coupling can result.

VENTING REQUIREMENTS

Exhaust venting: Exhaust your dryer to the outside. 4" (102 mm) diameter vent is required. Rigid or flexible metal exhaust vent must be used. Do not use plastic or metal foil vet. Exhaust hood must be at least 12" (305 mm) from the ground or any object that may be in the path of the exhaust.

Exhaust hoods:

Recommended Styles:

 

 

 

Louvered Hood

 

Box Hood

Acceptable Style:

Angled Hood

Determine vent path:

■■ Select route that will provide straightest and most direct path outdoors.

■■ Plan installation to use fewest number of elbows and turns.

■■ When using elbows or making turns, allow as much room as possible.

■■ Bend vent gradually to avoid kinking. ■■ Use as few 90° turns as possible.

Determine vent length and elbows needed for best drying performance:

■■ Use following Vent System Chart to determine type of vent material and hood combinations acceptable to use.

NOTE: Do not use vent runs longer than those specified in Vent System Chart. Exhaust systems longer than those specified will:

■■ Shorten life of dryer.

■■ Reduce performance, resulting in longer drying times and increased energy usage.

Standard Vent System Chart

Number of

Type

Box/louvered

Angled

90° elbows

of vent

hoods

hoods

 

 

 

 

0

Rigid metal

64 ft. (20 m)

58 ft. (17.7 m)

 

 

 

 

1

Rigid metal

54 ft. (16.5 m)

48 ft. (14.6 m)

 

 

 

 

2

Rigid metal

44 ft. (13.4 m)

38 ft. (11.6 m)

 

 

 

 

3

Rigid metal

35 ft. (10.7 m)

29 ft. (8.8 m)

 

 

 

 

4

Rigid metal

27 ft. (8.2 m)

21 ft. (6.4 m)

 

 

 

 

NOTE: Side and bottom exhaust installations have a 90° turn inside the dryer. To determine maximum exhaust length, add one 90° turn to the chart.

Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.

Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.