Electric Dryer
PRODUCT MODEL NUMBERS
NED4600Y, NED4700Y, NED4655E, NED4705E
Installation clearances:
The location must be large enough to allow the dryer door to
open fully.
Dryer Dimensions
Minimum spacing for recessed area or closet installation
Minimum Required Spacing
(76 mm)
3"*
(76 mm)
18"*
(457 mm)
1"
(25 mm)
29"
(737 mm)
1"
(25 mm)
A
A. Recessed area
B. Side view - closet or conned area
C. Closet door with vents
1"*
(25 mm)
27¾"
(705 mm)
*Additional spacing recommended
14" max.*
(356 mm)
B
2
48 in.
(310 cm )
24 in.
(155 cm )
*
2
2
*
2
C
*Most installations require a minimum 5½" (140 mm) clearance
behind the dryer for the exhaust vent with elbow. See “Venting
Requirements.”
Installation spacing for recessed area or closet installation
The dimensions shown following are for the minimum spacing allowed.
■ Additional spacing should be considered for ease of installation and servicing.
■ Additional clearances might be required for wall, door, and oor moldings.
■ Additional spacing of 1" (25 mm) on all sides of the dryer
is recommended to reduce noise transfer.
■ For closet installation, with a door, minimum ventilation openings in the top and
bottom of the door are required. Louvered doors with equivalent ventilation
opening are acceptable.
■ Companion appliance spacing should also be considered.
W10514172A
02/2015
ELECTRICAL REQUIREMENTS
To supply the required 3 or 4 wire, single phase, 120/240 volt, 60 Hz., AC only electrical supply (or 3 or 4 wire, 120/208 volt electrical
supply, if specied on the serial/rating plate) on a separate 30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit
breaker is recommended. Connect to an individual branch circuit.
VENTING REQUIREMENTS
Exhaust venting: Exhaust your dryer to the outside. 4" (102 mm)
diameter vent is required. Rigid or exible metal exhaust vent
must be used. Do not use plastic or metal foil vet. Exhaust hood
must be at least 12" (305 mm) from the ground or any object that
may be in the path of the exhaust.
Exhaust hoods:
Recommended Styles:
The Vent System Chart provides venting requirements that will
help achieve best drying performance.
Vent System Chart
Number of
90° turns
or elbows
0
Type
of vent
Rigid metal
Box/louvered
hoods
64 ft. (20 m)
Angled
hoods
58 ft. (17.7 m)
Louvered Hood
Box Hood
Acceptable Style:
Angled Hood
Determine vent path:
■ Select route that will provide straightest and most direct
path outdoors.
■ Plan installation to use fewest number of elbows and turns.
■ When using elbows or making turns, allow as much room
as possible.
■ Bend vent gradually to avoid kinking.
■ Use as few 90° turns as possible.
1
2
3
4
Rigid metal
Rigid metal
Rigid metal
Rigid metal
54 ft. (16.5 m)
44 ft. (13.4 m)
35 ft. (10.7 m)
27 ft. (8.2 m)
Vent System Chart
(Long Vent Models Only)
Number of
90° turns
or elbows
0 Rigid metal 120 ft. (36.6 m)
1
2
3
4
Type
of vent
Rigid metal
Rigid metal
Rigid metal
Rigid metal
Box/louvered, or
Angled hoods
110 ft. (33.5 m)
100 ft. (30.5 m)
90 ft. (27.4 m)
80 ft. (24.4 m)
48 ft. (14.6 m)
38 ft. (11.6 m)
29 ft. (8.8 m)
21 ft. (6.4 m)
Determine vent length and elbows needed for best
drying performance:
■ Use following Vent System Chart to determine type of vent
material and hood combinations acceptable to use.
NOTE: Do not use vent runs longer than those specied
in Vent System Chart. Exhaust systems longer than those
specied will:
■ Shorten life of dryer.
■ Reduce performance, resulting in longer drying times
and increased energy usage.
Because Whirlpool Corporation policy includes a continuous commitment to improve Dimensions are for planning purposes only. For complete details, see Installation
our products, we reserve the right to change materials and specications without notice. Instructions packed with product. Specications subject to change without notice.
5
NOTE: Bottom exhaust installations have a 90º turn inside the
dryer. To determine maximum exhaust length, add one 90º turn
to the chart.
Rigid metal
70 ft. (21.3 m)