Amana NED5100T, NED5400T, NED5500T, NED5800T, NED5200T User Manual

...
Electric Dryer
PRODUCT MODEL NUMBERS PRODUCT DIMENSIONS
RECESSED AREA AND CLOSET INSTALLATION
EXHAUST VENTING
NED4500V NED5100T NED5200T NED5240T
NED5400T NED5500T NED5800T NED4800V
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Ref. W10150612
09-05-08
43³⁄₈"
(
110cm)
*26" (66cm)
29"
(73.66cm)
A
15¹⁄₄"
(38.74cm)
43³⁄₈"
(110cm)
*27³⁄₄"
(70.5cm)
29"
(73.66cm)
B
22³⁄₄"
(57.8cm)
43³⁄₈"
(110cm)
13³⁄₄"
(34.9cm
)
*27³⁄₄"
(70.5cm)
29"
(73.66cm)
D
43
³⁄₈
"
(
110cm)
*27³⁄₄"
(70.5cm)
29"
(73.66cm)
C
22³⁄₄"
(57.8cm)
For closet installation with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent air openings are acceptable.
1. Select the route that will provide the straightest and most direct path outdoors. Plan the installation to use the fewest number of elbows and turns. When using elbows or making turns, allow as much room as possible. Bend vent gradually to avoid kinking. Use the fewest 90° turns possible.
2. Determine vent length.
The maximum length of the exhaust system depends upon:
• The type of vent (rigid metal or flexible metal).
• The number of elbows used.
• Type of hood.
See the exhaust vent length chart that matches your hood type for the maximum vent lengths you can use.
3. Determine the number of elbows you will need.
IMPORTANT: Do not use vent runs longer than specified in the Vent Length Chart. In the column listing the type of metal vent you are using (rigid metal or flexible metal), find the
maximum length of metal vent on the same line as the number of elbows.
Number of
90° turn s
or elbows
Type of
vent
Box or
Louvered
hoods
Angled
hoods
0 Rigid metal
Flexible metal
64 ft (20 m) 36 ft (11 m)
58 ft (17.7 m) 28 ft (8.5 m)
1 Rigid metal
Flexible metal
54 ft (16.5 m) 31 ft (9.4 m)
48 ft (14.6 m) 23 ft (7 m)
2 Rigid metal
Flexible metal
44 ft (13.4 m) 27 ft (8.2 m)
38 ft (11.6 m) 19 ft (5.8 m)
3 Rigid metal
Flexible metal
35 ft (10.7 m) 25 ft (7.6 m)
29 ft (8.8 m) 17 ft (5.2 m)
4 Rigid metal
Flexible metal
27 ft (8.2 m) 23 ft (7 m)
21 ft (6.4 m) 15 ft (4.6 m)
Electrical: To supply the required three- or four­wire, single-phase, 120/240-volt, 60-Hz, AC-only electrical supply (or three- or four-wire, 120/208-volt electrical supply, if specified on the serial/rating plate) on a separate 30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended. Connect to an individual branch circuit. Do not have a fuse in the neutral or grounding circuit.
Exhaust venting: Exhaust your dryer to the outside. Four-inch diameter vent is required. Rigid or flexible metal exhaust vent must be used. Do Not use plastic or metal foil vent. Exhaust outlet hood must be at least 12" (30.5 cm) from the ground or any object that may be in the path of the exhaust.
A. Small Opening
Side-Swing Door
B. Large Opening
Side-Swing Door
C. Wide Opening
Side-Swing Door
D. Wide Opening
Hamper Door
*Most installations require a minimum 5" (12.7 cm) clearance behind the dryer for exhaust
vent with elbow.
®
Louvered style
4" (10.2 cm)
4" (10.2 cm)
Box hood style
4"
(10.2 cm)
2.5"
(6.4 cm)
Angled style
Vent System Chart NOTE: Side and bottom exhaust installations have
a 90° turn inside the dryer. To determine maximum exhaust length, add one 90° turn to the chart.
18"* (45.7 cm)
14" max.* (35.6
cm)
2
48 in.
*
2
(310 cm )
1" (2.5 cm)
29" (73.66 cm)
1" (2.5 cm)
1"* (2.5 cm)
27¾" (70.5 cm)
A
A. Recessed area B. Side view - closet or confined area C. Closet door with vents
5"* (12.7 cm)
B
2
*
24 in.
2
(155 cm )
C
*Required spacing
3"* (7.6 cm)
3"* (7.6 cm)
Loading...