Amana AMV6167BD User Manual

A
B
C
PRODUCT MODEL NUMBERS
PRODUCT DIMENSIONS
VENTING REQUIREMENTS
AMV5206BA AMV6167BD
Electrical: 120-volt, 60-Hz, AC-only. AMV5206BA requires 15-amps and
1.7 kilowatts and AMV6167BD requires 13-amps and 1.5 kilowatts. This product must be connected to a supply circuit of the proper voltage
and frequency. Wire size must conform to the requirements of the National Electrical Code or the prevailing local code for this kilowatt rating. The power supply cord and plug should be brought to a separate 20 amp branch circuit single grounded outlet. The outlet box should be located in the cabinet above the microwave oven. The outlet box and supply circuit should be installed by a qualified electrician and conform to the National Electrical Code or the prevailing local code.
Over the Range Microwave Oven
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Ref. 8101P710-60
09-11-08
CABINET OPENING DIMENSIONS
A 3¹⁄₄" x 10" (8.3 x 25.4 cm) rectangular or 6" (15.2 cm) round vent should be used.
The total length of the vent system including straight vent, elbow(s), transitions and wall or roof caps must not exceed the equivalent of 140 ft (42.7 m) for either type of vent.
Outside ventilation requires a HOOD EXHAUST DUCT. Read the following carefully.
NOTE: It is important that venting be installed using the most direct route and with as few elbows as possible. This ensures clear venting of exhaust and helps prevent blockages. Also, make sure dampers swing freely and
nothing is blocking the ducts.
For best performance, use no more than three 90° elbows. To calculate the length of the system you need, add the equivalent length
for each vent piece used in the system. See the following examples:
Backsplash
16-½ "
33"min.
5"
3
0
"
Bottom edge of cabinet needs to be 33" or more from the cooking surface
®
OUTSIDE TOP EXHAUST (EXAMPLE ONLY)
The following chart describes an example of one possible ductwork installation.
* IMPORTANT: If a rectangular-to-round transition adaptor is used, the bottom corners of the damper will have to be cut to fit, using tin snips, in order to allow free movement of the damper.
TNELAVIUQESECEIP TCUD
LENGTH x
NUMBER USED =
EQUIVALENT LENGTH
Roof Cap 24 Ft. x (1) = 24 Ft.
12 Ft. Straight Duct (6" Round)
12 Ft. x (1) = 12 Ft.
Rectangular-to-Round Transition Adaptor*
5 Ft. x (1) = 5 Ft.
Equivalent lengths of duct pieces are based on actual tests and reflect requirements for good venting performance with any vent hood.
Total Length = 41 Ft.
(7.3 m)
(3.7 m)
(1.5 m)
(7.3 m)
(3.7 m)
(1.5 m)
(12.5 m)
OUTSIDE BACK EXHAUST (EXAMPLE ONLY)
The following chart describes an example of one possible ductwork installation.
NOTE: For back exhaust, care should be taken to align exhaust with space between studs, or wall should be prepared at the time it is constructed by leaving enough space between the wall studs to accommodate exhaust.
TNELAVIUQESECEIP TCUD
LENGTH* x
NUMBER USED =
EQUIVALENT LENGTH
Roof Cap 40 Ft. x (1) = 40 Ft.
3 Ft. Straight Duct (3¼" x 10" Rectangular)
3 Ft. x (1) = 3 Ft.
90° Elbow 10 Ft. x (2) = 20 Ft.
Equivalent lengths of duct pieces are based on actual tests and reflect requirements for good venting performance with any vent hood.
Total Length = 63 Ft.
(12.2 m)
(1 m)
(3 m)
(12.2 m)
(1 m)
(6.1 m)
(19.2 m)
Width (A) Depth (B) Height (C)
AMV5206BA 29-7/8" 17" 16-15/16"
(75.9 cm) (43.2 cm) (43.0 cm)
AMV6167BD 29-7/8" 15-21/32" 16-15/16"
(75.9 cm) (39.8 cm) (43.0 cm)
NOTES:
• The space between the cabinets must be 30" (76.2 cm) wide and free of obstructions.
• This microwave oven is for installation over ranges up to 33" (83.8 cm) wide.
• If you are going to vent your microwave oven to the outside, see Venting Requirements for exhaust duct preparation.
When installing the microwave oven beneath smooth flat
cabinets be careful to follow the instructions on the top cabinet template for power cord clearance.
Loading...