Amana ACU102PK Installation Instructions

Home
Home
Installation Instructions and
Use & Care Guide
THROUGH-THE-WALL AIR CONDITIONER
PART NO. 23-11-1186N-005/789957
www.whirlpool.com
Contents & Air Conditioner Safety
Important Safety Instructions ........................ 2
Electrical Requirements ................................. 3
Installation Instructions .................................. 7
Operating Instructions .................................. 10
Starting your air conditioner ......................... 10
Heat/Cool air conditioner heat settings ....... 10
The exhaust vent control ............................. 11
Changing air direction .................................. 11
Cleaning Instructions ................................... 12
Cleaning the slide-out air filter ...................... 12
Maintenance Instructions ............................. 13
Annual maintenance..................................... 13
Energy saving tips ........................................ 13
Troubleshooting............................................. 14
Requesting Assistance or Service ............... 15
Warranty ......................................................... 16
Page
Your safety and the safety
of others are very important.
We have provided many important safety messages in this manual and on your appli­ance. Always read and obey all safety messages.
This is the safety alert symbol. This symbol alerts you to potential
hazards that can kill or hurt you and
others. All safety messages will be preceded by the
safety alert symbol and the word “DANGER” or WARNING. These words mean:
DANGER
You can be killed or seriously injured if you don’t
immediately follow instructions.
WARNING
You can be killed or seriously injured if you don’t follow instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.
2

Important Safety Instructions

WARNING To reduce the risk of fire, electrical shock, injury, or sickness when using your air conditioner, follow these basic precautions:
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Unplug air conditioner before servicing.
Use two or more people to move or install air
conditioner.
Do not drink water collected inside the cabinet.
— SAVE THESE INSTRUCTIONS —
Help us help you
Please:
Install your air conditioner in a window that will hold the weight, and secure the air conditioner according to the Installation Instructions.
Connect the air conditioner to the proper kind of outlet with the correct electrical supply and ground. (See the Electrical Requirements, pp. 3-6.)
Make sure the air conditioner is the correct size for the area you want to cool.
Use the air conditioner only to do what a window air conditioner is designed to do.
Make sure the air conditioner is not used by anyone unable to operate it properly.
Maintain the air conditioner properly.
Also, remove the Energy Label. Use a damp cloth to take off any glue residue. DO NOT use sharp instruments, flammable fluids, or abrasive cleaners. These can damage the air conditioner finish.

Electrical Requirements

Below are electrical plug variations, choose the one which matches the ampere rating of your unit. Your models ampere rating is printed on the model and serial number label, attached to the unit, behind the front panel. (See diagram on page 15.)
If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate.
Plug into a grounded 3-prong outlet. Do not remove ground prong. Do not use an adapter. Do not use an extension cord. Failure to follow these instructions can
result in death, fire, or electrical shock.
IMPORTANT SAFETY INSTRUCTIONS • ELECTRICAL REQUIREMENTS
WARNING
Electrical Shock Hazard
PLUG TYPE
3-prong
ground plug
Ground
3-prong
ground plug
Small
blades
prong
Ground
prong
Power supply cord
Power supply cord
1
4" blade
tandem
3-prong
ground-type
outlet
3-prong
ground-type
outlet
3-prong
ground-type
outlet
Ground
prong
ELECTRICAL REQUIREMENTS
115-volt models with amperes up through 7.5
For 115-volt models with amperes from 7.6 to 12.0
230/208-volt models with amperes up through 12.0
SEE PAGE
4
5
6
3
Electrical Requirements Continued
WARNING
Electrical Shock Hazard Plug into a grounded 3-prong outlet. Do not remove ground prong. Do not use an adapter. Do not use an extension cord. Failure to follow these instructions can
result in death, fire, or electrical shock.
3-prong ground plug
Ground
prong
Power supply cord
3-prong ground-
type
outlet
(double
outlet)
115-volt models with amperes up through 7.5
Outlet wiring
Outlet wiring should be a minimum of 14 gauge. Use copper wire only. It is the responsibility of the consumer to provide proper and adequate receptacle wiring, installed by a qualified electrician. Observe National Electrical Code and all local governing codes and ordinances.
Electrical requirements
A 115-volt (103.5 min., 126.5 max.), 60-Hz, AC-only, 15-ampere fused electrical supply is required (time delay fuse or time delay circuit breaker required). It is required that a separate circuit, serving only this air conditioner, be provided.
Electrical connection
Electrical ground is required on this air conditioner.
Recommended ground method
For your personal safety, this air conditioner must be grounded. This air conditioner is equipped with a power supply cord having a 3-prong ground plug. To minimize possible shock hazard, the cord must be plugged into a mating 3-prong ground-type outlet, grounded in accordance with the National Electrical Code (ANSI/NFPA 70 – latest edition) and local codes and ordinances. If a mating outlet is not available, it is the responsi­bility of the customer to have a properly grounded 3-prong outlet installed by a qualified electrician.
4
WARNING
Electrical Shock Hazard Plug into a grounded 3-prong outlet. Do not remove ground prong. Do not use an adapter. Do not use an extension cord. Failure to follow these instructions can
result in death, fire, or electrical shock.
3-prong ground plug
Ground
prong
Power supply cord
3-prong ground-
type
outlet
(single
outlet)
ELECTRICAL REQUIREMENTS
115-volt models with amperes from 7.6 through 12.0
Outlet wiring
Outlet wiring should be a minimum of 14 gauge. Use copper wire only. It is the responsibility of the consumer to provide proper and adequate receptacle wiring, installed by a qualified electrician. Observe National Electrical Code and all local governing codes and ordinances.
Electrical requirements
A 115-volt (103.5 min., 126.5 max.), 60-Hz, AC-only, 15-ampere fused electrical supply is required (time delay fuse or time delay circuit breaker required). It is required that a separate circuit, serving only this air conditioner, be provided.
Electrical connection
Electrical ground is required on this air conditioner.
Recommended ground method
For your personal safety, this air conditioner must be grounded. This air conditioner is equipped with a power supply cord having a 3-prong ground plug. To minimize possible shock hazard, the cord must be plugged into a mating 3-prong ground-type outlet, grounded in accordance with the National Electrical Code (ANSI/NFPA 70 – latest edition) and local codes and ordinances. If a mating outlet is not available, it is the responsi­bility of the customer to have a properly grounded 3-prong outlet installed by a qualified electrician.