Power over the Ethernet
Installation Guide
Models Include:
NetWaySP2
- 2-port Fiber Optic Transceiver for Composite Fiber (Powered) Cable
NetWaySP4
- 4-port Fiber Optic Transceiver for Composite Fiber (Powered) Cable
NetWaySP8
- 8-port Fiber Optic Transceiver for Composite Fiber (Powered) Cable
DOC#: NETWAYSP Rev. 020217
More than just power.
TM
![](/html/42/42db/42db8e15b2d0c24c2b8b6a9aa70257535e8c4f6d60d302801741b26aa1698417/bg2.png)
Altronix NetWaySP2/4/8 Fiber Optic Transceivers with optional PoE power provide up to eight (8) 1Gb SFP
ports and eight (8) ports for up to 120W per port to be transmitted over composite fiber (powered) cable (fiber +
copper combined) to NetWay Spectrum PoE+ Hardened Switches. NetWaySP2/4/8 can be used for standard fiber
cable applications as well.
Specifications:
Overview:
Agency Listings:
• UL/cUL UL 60950-1 (Information
Technology Equipment).
• CE European Conformity.
Input:
• Options:
- 48-56V: UL Listed ITE power supply i.e.
VertiLine563 (2 x 56V / 150W ports).
- PoE+ (30W) or Hi-PoE (60W)
(midspan/endspan)
• NetWaySP2: Two (2) RJ45 inputs up to 60W max.
NetWaySP4: Four (4) RJ45 inputs up to 60W max.
NetWaySP8: Eight (8) RJ45 inputs up to 60W max.
Power:
• NetWaySP2: Two (2) outputs.*
NetWaySP4: Four (4) outputs.*
NetWaySP8: Eight (8) outputs.*
(All output power is dependent on input).
• IEEE 802.3af and IEEE 802.3at compliant
(PoE/PoE+).
• Short circuit protection.
Fiber Ports:
• Four (4) Gigabit SFP ports.
• Use with SFP module 1000Base-X (1Gb),
compliant to Class 1 laser product (not included).
* Outputs are Class 2 Power-Limited: when powered by PoE, PoE+, Hi-PoE unit or UL Listed power-limited supply. If supplied
by a non-limited power source, the output of the device must be considered as a non-limited power source. For non-limited
power sources, the unit must be installed in a restricted access, and the need for additional protective circuitry and/or an
appropriate fire enclosure for the products supplied by this device, shall be determined in the installation of the device.
Ethernet:
• NetWaySP2: Two (2) ports.
NetWaySP4: Four (4) ports.
NetWaySP8: Eight (8) ports.
• Wire type: 4-pair CAT5e and higher.
• Connectivity: RJ45, auto-crossover.
• Speed: 10/100/1000 Mbps.
• Distance: up to 100m.
Environmental:
• Refer to Environmental Conditions on page 3.
Compatible PoE
Hardened Switches and Accessories:
NetWaySP3WPN: 3-port PoE Hardened Switch
with (1) SFP port.
NetWay4EWPN: 4-port PoE Hardened Switch
with (1) SFP port.
NetWaySP4WPN: 4-port PoE Hardened Switch
with (2) SFP ports.
NetWaySP8WPN: 8-port PoE Hardened Switch
with (2) SFP ports.
Wiring methods shall be in accordance with the National Electrical Code (ANSI/NFPA70), local codes, and the
Installation Instructions:
authorities having jurisdiction. NetWaySP2/4/8 is not intended to be connected to outside plant leads. These
products are for indoor use only and must be installed within the protected premises.
1. Attach mounting brackets to unit for rack or wall mount installation (Fig. 2 or 4, pg. 4).
Affix rubber pads to unit for shelf installation (Fig. 4, pg. 4).
2. Secure the unit in a rack or on a wall, or place unit on a shelf as desired.
Note: The following factors should be taken into consideration when installing these rack mount units:
a. The unit is to be installed in a space where the maximum ambient temperature does not exceed 104ºF (40ºC).
b. Take care to ensure that there is sufficient air flow around the unit and that obstructions do not impede it.
c. When mounting units in a rack, take care to avoid uneven loading which can cause a hazardous condition.
3. Input Power Options:
- Connect structured cable from ethernet (midspan or endspan) device to RJ45 jack marked [Ethernet]
(Fig. 2, pg. 3).
- Connect 48-56V UL Listed ITE power supply (rated minimum ambient temperature of 50ºC, or the
installation of the device must conform to the rated ambient temperature of the power supply) to terminals
marked [– In +, 56VDC] (Fig. 2 pg. 3).
4. Daisy-chaining inputs: Connect terminals marked [– Pass +, 56VDC] to the next input terminals marked
[– In +, 56VDC] (Fig. 2 pg. 3).
5. Connect Composite (Powered) Fiber cable. Fiber portion connects to port marked [SFP 1-4], copper portion
connects to output marked [OUT 56VDC, 1-4] (Fig. 1, pg. 3).
6. Connect opposite end of Composite (Powered) Fiber cable. Fiber portion connects to SFP port on
NetWaySP3WPN or NetWay4EWPN, copper portion connects to power input of NetWay Spectrum Hardened
Switch, carefully observing correct polarity (Refer to NetWaySP3WPN/4WPN/8WPN / NetWay4EWPN
Installation Guides).
- 2 - NetWaySP2/4/8