Power over the Ethernet
Installation Guide
Models Include:
NetWaySP2
- 2-port Fiber Optic Transceiver for Composite Fiber (Powered) Cable
NetWaySP4
- 4-port Fiber Optic Transceiver for Composite Fiber (Powered) Cable
NetWaySP8
- 8-port Fiber Optic Transceiver for Composite Fiber (Powered) Cable
DOC#: NETWAYSP Rev. 020217
More than just power.
TM

Altronix NetWaySP2/4/8 Fiber Optic Transceivers with optional PoE power provide up to eight (8) 1Gb SFP
ports and eight (8) ports for up to 120W per port to be transmitted over composite fiber (powered) cable (fiber +
copper combined) to NetWay Spectrum PoE+ Hardened Switches. NetWaySP2/4/8 can be used for standard fiber
cable applications as well.
Specifications:
Overview:
Agency Listings:
• UL/cUL UL 60950-1 (Information
Technology Equipment).
• CE European Conformity.
Input:
• Options:
- 48-56V: UL Listed ITE power supply i.e.
VertiLine563 (2 x 56V / 150W ports).
- PoE+ (30W) or Hi-PoE (60W)
(midspan/endspan)
• NetWaySP2: Two (2) RJ45 inputs up to 60W max.
NetWaySP4: Four (4) RJ45 inputs up to 60W max.
NetWaySP8: Eight (8) RJ45 inputs up to 60W max.
Power:
• NetWaySP2: Two (2) outputs.*
NetWaySP4: Four (4) outputs.*
NetWaySP8: Eight (8) outputs.*
(All output power is dependent on input).
• IEEE 802.3af and IEEE 802.3at compliant
(PoE/PoE+).
• Short circuit protection.
Fiber Ports:
• Four (4) Gigabit SFP ports.
• Use with SFP module 1000Base-X (1Gb),
compliant to Class 1 laser product (not included).
* Outputs are Class 2 Power-Limited: when powered by PoE, PoE+, Hi-PoE unit or UL Listed power-limited supply. If supplied
by a non-limited power source, the output of the device must be considered as a non-limited power source. For non-limited
power sources, the unit must be installed in a restricted access, and the need for additional protective circuitry and/or an
appropriate fire enclosure for the products supplied by this device, shall be determined in the installation of the device.
Ethernet:
• NetWaySP2: Two (2) ports.
NetWaySP4: Four (4) ports.
NetWaySP8: Eight (8) ports.
• Wire type: 4-pair CAT5e and higher.
• Connectivity: RJ45, auto-crossover.
• Speed: 10/100/1000 Mbps.
• Distance: up to 100m.
Environmental:
• Refer to Environmental Conditions on page 3.
Compatible PoE
Hardened Switches and Accessories:
NetWaySP3WPN: 3-port PoE Hardened Switch
with (1) SFP port.
NetWay4EWPN: 4-port PoE Hardened Switch
with (1) SFP port.
NetWaySP4WPN: 4-port PoE Hardened Switch
with (2) SFP ports.
NetWaySP8WPN: 8-port PoE Hardened Switch
with (2) SFP ports.
Wiring methods shall be in accordance with the National Electrical Code (ANSI/NFPA70), local codes, and the
Installation Instructions:
authorities having jurisdiction. NetWaySP2/4/8 is not intended to be connected to outside plant leads. These
products are for indoor use only and must be installed within the protected premises.
1. Attach mounting brackets to unit for rack or wall mount installation (Fig. 2 or 4, pg. 4).
Affix rubber pads to unit for shelf installation (Fig. 4, pg. 4).
2. Secure the unit in a rack or on a wall, or place unit on a shelf as desired.
Note: The following factors should be taken into consideration when installing these rack mount units:
a. The unit is to be installed in a space where the maximum ambient temperature does not exceed 104ºF (40ºC).
b. Take care to ensure that there is sufficient air flow around the unit and that obstructions do not impede it.
c. When mounting units in a rack, take care to avoid uneven loading which can cause a hazardous condition.
3. Input Power Options:
- Connect structured cable from ethernet (midspan or endspan) device to RJ45 jack marked [Ethernet]
(Fig. 2, pg. 3).
- Connect 48-56V UL Listed ITE power supply (rated minimum ambient temperature of 50ºC, or the
installation of the device must conform to the rated ambient temperature of the power supply) to terminals
marked [– In +, 56VDC] (Fig. 2 pg. 3).
4. Daisy-chaining inputs: Connect terminals marked [– Pass +, 56VDC] to the next input terminals marked
[– In +, 56VDC] (Fig. 2 pg. 3).
5. Connect Composite (Powered) Fiber cable. Fiber portion connects to port marked [SFP 1-4], copper portion
connects to output marked [OUT 56VDC, 1-4] (Fig. 1, pg. 3).
6. Connect opposite end of Composite (Powered) Fiber cable. Fiber portion connects to SFP port on
NetWaySP3WPN or NetWay4EWPN, copper portion connects to power input of NetWay Spectrum Hardened
Switch, carefully observing correct polarity (Refer to NetWaySP3WPN/4WPN/8WPN / NetWay4EWPN
Installation Guides).
- 2 - NetWaySP2/4/8

Altronix P1MM and P1SM10 are hot-pluggable SFP fiber transceiver modules and are readily usable with all
Altronix Spectrum fiber optic equipment for 1Gb transmission rates.
P1MM - For use with Multi-Mode Fiber for distances up to 550m.
P1SM10 - For use with Single-Mode Fiber for distances up to 10km.
Technical Specifications:
Recommended Altronix SFP Modules:
Parameter Description
NetWaySP2: Two (2) - Gigabit SFP Ports. Two (2) ports 10/100/1000 Mbps.
Number of Ports
NetWaySP4: Four (4) - Gigabit SFP Ports. Four (4) ports 10/100/1000 Mbps.
NetWaySP8: Eight (8) - Gigabit SFP Ports. Eight (8) ports 10/100/1000 Mbps.
NetWaySP2: Two (2) outputs.
Power Outputs
NetWaySP4: Four (4) outputs.
NetWaySP8: Eight (8) outputs.
(All output power is dependent on input).
Input Power
Requirements
- 48-56V: UL Listed ITE power supply i.e. VertiLine563 (2 x 56V / 150W ports).
- PoE+ (30W) or Hi-PoE (60W) (midspan/endspan)
Operating Ambient Temperature (120W): – 40ºC to 50ºC (– 40ºF to 122ºF)
Environmental
Conditions
Relative Humidity: 85%, +/– 5%
Storage Temperature: – 40ºC to 85ºC (– 40ºF to 185ºF).
Operating Altitude: – 304.8 to 2,000m.
Weights (approx.)
NetWaySP4: Product: 2.55 lb. (1.16kg) | Shipping: 4.7 lb. (2.13kg).
NetWaySP4 Typical Application:
Fig. 1
PoE+ Camera
PoE+ Camera
WiFi Access
Point
NetWaySP4 Front Panel
NetWay
Spectrum
PoE+
Hardened
Switch
NetWay
Spectrum
PoE+
Hardened
Switch
Composite (Powered) Fiber Cable
PoE+ Camera
PoE+ Camera
WiFi Access
Point
NetWay
Spectrum
PoE+
Hardened
Switch
Fiber
CopperFiber
CopperFiber
Copper
PoE+ Camera
PoE+ Camera
WiFi Access
Point
NetWaySP4 Rear Panel
Daisy Chaining
Power Inputs
Midspan/Endspan
Input Power Options
48-56V UL Listed
ITE Power Supply
The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence
of an insulated DANGEROUS VOLTAGE within the product’s enclosure that may be of sufficient magnitude to
constitute an electric shock.
The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating
and maintenance (servicing) instructions in the literature accompanying the appliance.
CAUTION: To reduce the risk of electric shock do not open enclosure.
There are no user serviceable parts inside. Refer servicing to qualified service personnel.
NetWaySP2/4/8 - 3 -

Mounting Options:
Rack Mount Installation
1. Remove and discard factory installed screws from both sides of rack chassis (Fig. 2a).
2. Install mounting brackets (A) on the left and right side of rack chassis using the four (4) flat head screws (B)
(included) (Fig. 2b).
3. Place unit into desired EIA 19” rack position and secure with mounting screws (not included) (Fig. 2c).
Fig. 2
Fig. 2a
Fig. 2b
Fig. 2c
Top Top
Front
Left
A
Remove
Front
Left
B
Wall Mount Installation
1. Install mounting brackets (A) on the left and right side of rack chassis using
four (4) flat head screws (B) (included) (Fig. 3a).
2. Place unit at desired location and secure with #6 size screws or larger (not included) (Fig. 3b).
Caution: It is necessary to make sure mounting screws are securely fastened
to a beam when installing the unit vertically.
Fig. 3
Fig. 3a
B
Fig. 3b
A
Top
Front Left
Dotted lines indicate studs behind sheetrock.
Shelf Installation
1- Position and affix rubber pads (C) (included) at each corner on the bottom of the unit (Fig. 4).
2- Place unit in desired location.
Fig. 4
Left Side
C
Rubber
Pad
Altronix is not responsible for any typographical errors.
140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056
website: www.altronix.com | e-mail: info@altronix.com | Lifetime Warranty | Made in U.S.A.
IINetWaySP2/4/8 H07R
- 4 - NetWaySP2/4/8
Mounting Hardware (Included):
Two (2) mounting brackets
A
Six (6) flat head screws
B
for mounting brackets.
Four (4) rubber pads.