Power over the Ethernet
PoE Managed Midspan Solution for
Standard Network Infrastructure
NetWay4BT
- 4-Port Managed 802.3bt Midspan Injector
- 360W total power
NetWay8BT
- 8-Port Managed 802.3bt Midspan Injector
- 480W total power
Installation Guide
I.T.E. 43KC
DOC#: NETBT Rev. 050719
More than just power.
TM
Table of Contents:
Overview .................................................................................................pg. 3
Features .......................................................................pg. 3
Installation Instructions ..........................................................pg. 3
Technical Specifications ..........................................................pg. 4
Installing a NetWayXTG Repeater Module .........................................pg. 5
Port LED Definitions for NetWayXTG Repeater .....................................pg. 5
NetWay8BT Typical Applications .................................................pg. 6
Technical Specifications ..........................................................pg. 6
Configuring NetWay4BT/NetWay8BT for Network Connection
Factory Default Settings ........................................................pg. 6
Network Settings ..............................................................pg. 6
Static .......................................................................pg. 6
DHCP .......................................................................pg. 7
Secure Network Setup (HTTPS) ..................................................pg. 7
Mounting Options ..............................................................pg. 8
- 2 - NetWay4BT/NetWay8BT
Altronix NetWay4BT/NetWay8BT Networked Managed Midspan provides PoE/PoE+/Hi PoE (up to 90W)
power per port, and pass data at 10/100/1000 Mbps at distances up to 100m. Features also include an integral
battery charger for applications requiring backup and embedded LINQ Technology to monitor, control, and report
power and diagnostics from anywhere.
Features:
Overview:
Agency Listings:
• UL 60950-1 Information Technology
Equipment.
• CE European Conformity.
Input:
• 115VAC, 60Hz, 5.5A or 230VAC, 50/60Hz, 3.0A.
Power:
• Unit supplies PoE output voltage (55V) and up to
90W max. full power per port.
NetWay4BT total power: 360W.
NetWay8BT total power: 480W.
• IEEE 802.3af, IEEE, 802.3at and
IEEE802.3bt compliant.
• Short circuit protection.
Ethernet:
• Four (4) or eight (8) ports for cameras/edge devices
over ethernet.
• Wire type: 4-pair CAT5e and higher.
• Speed: 10/100/1000 Mbps.
Functions:
• Auto detection and protection of legacy non-PoE
cameras/edge devices.
Battery Backup:
• Built-in battery charger (optional rack mount
battery enclosure - RE2).
• Automatic switchover to stand-by battery when
AC fails.
LINQ Technology:
• SSL (Secure Socket Layer) security encryption.
• User level security.
• Built-in IP management allows for remote camera
reset and monitoring.
• Provides local and/or remote access to critical
information via LAN/WAN
• Email and Windows Dashboard Alert notifications
report real-time diagnostics.
• Event log tracks history.
Accessories:
NetWayXTG:
• PoE+ Gigabit repeater module extends
data range 100m and passes up to 30W.
RE2:
• Rack Mount Battery Enclosure accommodates up
to four (4) 12VDC/7AH batteries.
Installation Instructions:
Wiring methods shall be in accordance with the National
Electrical Code (ANSI/NFPA70), local codes, and the authorities
having jurisdiction. NetWay4BT/NetWay8BT unit is not intended to be
connected to outside plant leads. These products are for indoor use only and
must be installed within the protected premises. If battery bracket is removed,
then the unit must be installed in a restricted access area (Fig. 1b, pg. 3).
1. Attach mounting brackets to NetWay4BT/NetWay8BT unit for rack
or wall mount installation (Fig. 5 or 6, pg. 8).
Affix rubber pads to NetWay4BT/NetWay8BT for shelf installation (Fig. 7, pg. 8).
2. Secure the unit in a rack or on a wall, or place unit on a shelf as desired.
Note: The following factors should be taken into consideration when installing these rack mount units:
a. The unit is to be installed in a space where the maximum ambient temperature does not exceed 104ºF (40ºC).
b. Take care to ensure that there is sufficient air flow around the unit and that obstructions do not impede it.
c. When mounting units in a rack, take care to avoid uneven loading which can cause a hazardous condition.
3. Plug the grounded AC line cord (included) into the IEC 320 connector of the NetWay4BT/NetWay8BT
unit (Fig. 2g, pg. 4). Plug unit into a reliable earth grounded socket. When using multiple units, the sum
of the individual name plate ratings should not exceed the supply circuit rating.
Do not connect to a receptacle controlled by a switch.
4. Connect structured cables from port marked [IN] on NetWay4BT/NetWay8BT to the corresponding inputs
of an ethernet switch or video server (Fig. 2b, pg. 4, Fig. 4, pg. 6).
Note: All cabling and wire must be UL Listed and/or Recognized wire suitable for their application.
5. Connect structured cables from port marked [OUT] on NetWay4BT/NetWay8BT to PoE compliant
camera/edge devices (Fig. 2a, pg. 4, Fig. 4, pg. 6).
6. When the use of stand-by batteries is required, they must be sealed lead acid or gel type. Connect four (4)
12VDC batteries in series to terminals marked [+ BAT –] (Fig. 2h, pg. 4), carefully observing polarity.
Note: When batteries are not used a loss of AC will result in a loss of output voltage.
Fig. 1a Fig. 1b
NetWay4BT/NetWay8BT - 3 -