ALTV2432 Series
CCTV Power Supplies
Installation Guide
Models Include:
• ALTV2432 • ALTV2432CB
- 24VAC @ 8A (200VA) - 24VAC @ 8A (200VA) or 28VAC @ 7A (200VA). or 28VAC @ 7A (200VA).
- Thirty-two (32) Fuse Protected Outputs. - Thirty-two (32) PTC Protected Outputs.
- 24VAC @ 14A (350VA) - 24VAC @ 14A (350VA) or 28VAC @ 12.5A (350VA). or 28VAC @ 12.5A (350VA).
- Thirty-two (32) Fuse Protected Outputs. - Thirty-two (32) PTC Protected Outputs.
• ALTV2432600 • ALTV2432600CB
- 24VAC @ 28A (700VA) - 24VAC @ 28A (700VA) or 28VAC @ 25A (700VA). or 28VAC @ 25A (700VA).
- Thirty-two (32) Fuse Protected Outputs. - Thirty-two (32) PTC Protected Outputs.
Rev. 021704
Page 2
Overview:
ALTV2432 Series CCTV Power Supplies provide 24VAC/28VAC distributed via thirty-two (32) fuse or PTC protected outputs for powering CCTV Cameras, heaters and other video accessories.
Thirty-two (32) Output ALTV2432 Reference Chart:
Total
Output Altronix Model Number
ALTV2432
ALTV2432CB
ALTV2432350
ALTV2432350CB
ALTV2432600
ALTV2432600CB
Output
Voltage
24VAC 8A 28VAC 7A 24VAC 8A 28VAC 7A 24VAC 14A 28VAC 12.5A 24VAC 14A 28VAC 12.5A 24VAC 28A 28VAC 25A 24VAC 28A 28VAC 25A
Current (Power)
Input:
• 115VAC, 50/60Hz.
Output:
• Thirty-Two (32) fuse or PTC protected outputs.
• 24VAC or 28VAC supply current
• Outputs are rated @ 3.5A (fuse) or 2.5A (PTC).
• Surge suppression.
PTC
Number of
Outputs
32
Protected
Outputs
Specifications:
Features:
• Secondary fuse rated @ 10A/250V.
• AC power LED.
• Power ON/OFF switch.
• Spare fuses provided. (all models w/primary and/or secondary fuses).
Mechanical:
• Enclosure Dimensions (H x W x D approx.):
13.5” x 13” x 3.25” (342.9mm x 330.2mm x 82.55mm)
P
P
P
Output
Fuse
Protected
Outputs
-
-
-
P
- 2.5A
P
- 2.5A
P
- 2.5A
Current
(max per
output)
3.5A
3.5A
3.5A
115VAC
50/60Hz Input
Current
2.9A
2.7A
5.4A
Installation Instructions:
1. Mount unit in the desired location.
2. Turn main switch on the unit OFF (Figs. 1-3, pgs. 4-6).
3. All units are factory set for 24VAC operation. For 28VAC operation, adjust unit prior to mounting and applying power as follows: Change the wire position so that the black wire [28V] is connected to the terminal marked [P] and the yellow wire [24V] is connected to the terminal marked [S].
4. Connect AC power to the black and white flying leads of the transformer(s) (Figs. 1-3, pgs. 4-6), secure green lead to earth ground. Use 18 AWG or larger for all power connections.
5. Measure output voltage before connecting devices. This helps avoiding potential damage. CAUTION: Determine the maximum operating voltage of the equipment being powered before adjusting the output voltage.
6. Connect devices to the terminals marked [1P - 1N] through [16P - 16N] on PD16W/PD16WCB board (Figs. 1-3, pgs. 4-6), carefully observing polarity. Terminals marked [1P - 16P] are of the same polarity.
7. Turn main switch on the unit to the ON (RESET) position (Figs. 1-3, pgs. 4-6).
8. Green LED(s) will illuminate when unit is powered.
9. Upon completion of the wiring secure enclosure door with screws (supplied). CAUTION: Equipment to be installed/serviced by authorized / trained personnel only. Shut branch circuit power before installing/servicing equipment.
- 2 - ALTV2432 Series
Page 3
WARNING: To reduce the risk of fire or electric shock, do not expose the unit to rain or moisture. This installation should be made by qualified service personnel and should conform to the National Electrical Code and all local codes. Use 75 C or higher rated UL insulated wiring for connecting the unit to the mains.
Terminal Identification:
PD16W - Power Distribution Module
1P - 16P AC output. 1N - 16N AC output.
ALTV2432 Series - 3 -
Page 4
Fig. 1
r
ALTV2432 • ALTV2432CB
12345678
Connected
to Door
common
outputs protected
outputs
9 10 11 12 13 14 15 16
Used on PTC Models
(example: ALTV2432CB)
N
P
12345678
N
NPS
P
common
outputs protected
outputs
9 10 11 12 13 14 15 16
N
P
N
NPS
P
12345678
common
outputs protected
outputs
9 10 11 12 13 14 15 16
N
P
N
NPS
P
Green
Lead
(Ground)
PD16W
115VAC input,
50/60 Hz.
3.5A 250V
Black
Lead
White
Lead
Terminal Blocks for Fig. 1
For continuous protection against risk of fire
replace fuses with same type and rating.
XFMR
XFMR Input
PD16W
For continuous protection against risk of fire
replace fuses with same type and rating.
3.5A 250V
Power Switch
XFMR Input
XFMR Input
PTC’s
PD16W
Power Distribution Module
XFMR
Input:
24VAC o
28VAC
24VAC or 28VAC
operation.
fused or PTC protected outputs
1 through 16.
- 4 - ALTV2432 Series
Page 5
Fig. 2
r
ALTV2432350 • ALTV2432350CB
common
outputs protected
outputs
9 10 11 12 13 14 15 16
Connected
to Door
12345678
Used on PTC Models
(example: ALTV2432350CB)
N
P
12345678
NP
NPS
common
outputs protected
outputs
9 10 11 12 13 14 15 16
N
P
N
NPS
P
12345678
common
outputs
protected
outputs
9 10 11 12 13 14 15 16
N
P
N
NPS
P
Green
Lead
(Ground)
PD16W
3.5A 250V
115VAC input
50/60 Hz,
Terminal Blocks for Fig. 2
24VAC or 28VAC
fused or PTC protected outputs
1 through 16.
For continuous protection against risk of fire
replace fuses with same type and rating.
Black Lead
White Lead
XFMR Input
Power Switch
PD16W
XFMR*
For continuous protection against risk of fire
replace fuses with same type and rating.
3.5A 250V
Input:
24VAC o
28VAC
operation.
XFMR Input
XFMR Input
PTC’s
PD16W
Power Distribution Module
ALTV2432 Series - 5 -
Page 6
Fig. 3
24VAC or 28VAC
fused or PTC protected outputs
1 through 16.
Input:
24VAC o
r
28VAC
operation.
ALTV2432600 • ALTV2432600CB
common
outputs
protected
outputs
9 10 11 12 13 14 15 16
Connected
to Door
12345678
Used on PTC Models
(example: ALTV2432600CB)
N
P
12345678
N
NPS
P
common
outputs protected
outputs
9 10 11 12 13 14 15 16
N
P
N
NPS
P
12345678
common
outputs
protected
outputs
9 10 11 12 13 14 15 16
N
P
N
NPS
P
Green
Lead
(Ground)
PD16W
115VAC input,
50/60 Hz.
3.5A 250V
Black Lead
White Lead
Terminal Blocks for Fig. 3
For continuous protection against risk of fire
replace fuses with same type and rating.
XFMR*
XFMR Input
PD16W
For continuous protection against risk of fire
replace fuses with same type and rating.
3.5A 250V
Power
Switch
XFMR Input
XFMR Input
PTC’s
PD16W
Power Distribution Module
XFMR*
- 6 - ALTV2432 Series
Page 7
Enclosure Dimensions:
(
)
(
)
(
)
13.5” x 13” x 3.25” (342.9mm x 330.2mm x 82.55mm)
1.40”
(36mm)
5.10”
(130mm)
1.20”
(31mm)
13.0”
(330mm)
(36mm)
0.75”
(19mm)
1.40”
4.85”
(123mm)
12.5”
(318mm)
11.0”
(279mm)
4.85”
(123mm)
1.40”
(36mm)
(19mm)
0.75”
1.20”
(31mm)
0.9375” (24mm)
3.25”
(83mm)
1.20”
(31mm)
1.40”
(36mm)
5.10”
(130mm)
5.10”
(130mm)
3.25”
(83mm)
1.0”
(25mm)
1.0”
25mm
10.5”
267mm
1.0”
25mm
0.9375” (24mm)
1.0”
(25mm)
3.25”
(83mm)
3.25”
(83mm)
6.5625”
(167mm)
ALTV2432 Series - 7 -
Page 8
Notes:
Altronix is not responsible for any typographical errors.
Altronix Corp. 140 58th Street, Brooklyn, New York 11220 USA, 718-567-8181, fax: 718-567-9056 web site: www.altronix.com, e-mail: info@altronix.com. Lifetime Warranty, Made in U.S.A. IIALTV2432Series A07P
- 8 - ALTV2432 Series
MEMBER
Loading...