ALTV2416 Series
CCTV Power Supplies
Installation Guide
Models Include:
• ALTV2416 • ALTV2416CB
- 24VAC @ 8A (200VA) - 24VAC @ 8A (200VA)
or 28VAC @ 7A. or 28VAC @ 7A.
- Sixteen (16) Fuse Protected Outputs. - Sixteen (16) PTC Protected Outputs.
• ALTV2416350 • ALTV2416350CB
- 24VAC @ 14A (350VA) - 24VAC @ 14A (350VA)
or 28VAC @ 12.5A (350VA). or 28VAC @ 12.5A (350VA).
- Sixteen (16) Fuse Protected Outputs. - Sixteen (16) PTC Protected Outputs.
• ALTV2416300M • ALTV2416300CBM
- 24VAC @ 12.5A (300VA) - 24VAC @ 12.5A (300VA)
or 28VAC @ 10A (300VA). or 28VAC @ 10A (300VA).
- Sixteen (16) Fuse Protected Outputs. - Sixteen (16) PTC Protected Outputs.
• ALTV2416600 • ALTV2416600CB
- 24VAC @ 28A (700VA) - 24VAC @ 28A (700VA)
or 28VAC @ 25A (700VA). or 28VAC @ 25A (700VA).
- Sixteen (16) Fuse Protected Outputs. - Sixteen (16) PTC Protected Outputs.
Rev. 071712
Overview:
ALTV2416 Series CCTV Power Supplies provide 24VAC/28VAC distributed via sixteen (16) fuse or PTC protected outputs
for powering CCTV Cameras, heaters, and other video accessories.
Sixteen (16) Output ALTV2416 Reference Chart:
Total
Altronix
Model Number
ALTV2416
ALTV2416CB
ALTV2416350
ALTV2416350CB
ALTV2416300M
ALTV2416300CBM
ALTV2416600
ALTV2416600CB
Output
Output
Voltage
24VAC 8A
28VAC 7A
24VAC 8A
28VAC 7A
24VAC 14A
28VAC 12.5A
24VAC 14A
28VAC 12.5A
24VAC 12.5A
28VAC 10A
24VAC 12.5A
28VAC 10A
24VAC 28A
28VAC 25A
24VAC 28A
28VAC 25A
Current
(Power)
Number
of
Outputs
16 -----
16
16 -----
16
16 -----
16
16 -----
16
Specifications:
Input:
• 115VAC, 50/60Hz.
Output:
• Sixteen (16) fuse or PTC protected outputs.
• 24VAC or 28VAC output voltage.
• Outputs are rated @ 3.5A (fused) or 2.5A (PTC).
• Surge suppression.
Features:
• Surge suppression.
• AC power LED indicator.
• Power ON/OFF switch (ALTV2416 and ALTV2416CB).
• Illuminated power disconnect circuit breaker with
manual reset for all other models.
PTC
Protected
Outputs
P
P
P
P
Fuse
Protected
Outputs
P
----- 2.5A
P
----- 2.5A
P
----- 2.5A
P
----- 2.5A
Output
Current
(max. per
output)
3.5A
3.5A
3.5A
3.5A
Main Fuse
Ratings
Two (2)
5A/250V
-----
115VAC
50/60Hz
Input
Current
1.9A
2.7A
5.4A
Features (cont’d):
• Unit maintains camera synchronization.
• Ease of installation saves time & eliminates costly labor.
• Spare fuses included (on fuse protected models).
Enclosure Dimensions:
ALTV2416 and ALTV2416CB:
8.5” x 7.5” x 3.5” (215.9mm x 190.5mm x 88.9mm).
ALTV2416300M and ALTV2416300CBM:
8.5” x 7.5” x 3.75” (215.9mm x 191mm x 95mm).
ALTV2416350, ALTV2416350CB,
ALTV2416600, and ALTV2416600CB:
13.5” x 13” x 3.25” (342.9mm x 330.2mm x 82.55mm).
Installation Instructions:
1. Mount unit in the desired location. Mark and predrill holes in the wall to line up with the top two keyholes in the
enclosure. Install two upper fasteners and screws in the wall with the screw heads protruding. Place the enclosure’s
upper keyholes over the two upper screws, level and secure. Mark the position of the lower two holes. Remove the
enclosure. Drill the lower holes and install the three fasteners. Place the enclosure’s upper keyholes over the two
upper screws. Install the two lower screws and make sure to tighten all screws (Enclosure Dimensions, pg. 7, 8).
Secure enclosure to earth ground.
2. Slide switch on PD board to OFF position for models ALTV2416 and ALTV2416CB (Fig. 1, pg. 4).
Turn OFF main switch on all other models (Figs. 2-4, pgs. 4-6).
3. All units are factory set for 24VAC operation.
For 28VAC operation, adjust unit prior to mounting and applying power as follows:
Change the wire position so that the black wire [28V] is connected to the terminal marked [P] and
- 2 - ALTV2416 series
the yellow wire [24V] is connected to the terminal marked [S].
4. Connect AC power to the black and white flying lead of the transformer(s) (Figs. 1-4, pgs. 4-6).
Use 18 AWG or larger for all power connections.
5. Measure output voltage before connecting devices. This helps avoiding potential damage.
Terminals marked [1P - 8P] are positive of the same polarity.
CAUTION: Determine the maximum operating voltage of the equipment being powered before adjusting
the output voltage.
6. Connect devices to terminals marked [1P - 1N] through [8P - 8N] on PD8/PD8CB board (Fig. 1, pgs. 4),
carefully observing polarity [1P - 1N] through [16P - 16N] on PD16W/PD16WCB board.
7. Slide switch on PD board to ON position for models ALTV2416, and ALTV2416CB (Fig. 1, pg. 4).
Turn main switch on all other models to the “RESET” (ON) position (Figs. 3-5, pgs. 5-6).
8. Green LED will illuminate when the unit is powered.
9. Upon completion of the wiring, secure enclosure door with screws (supplied).
CAUTION: Equipment must be installed/serviced by authorized/trained personnel only.
Shut branch circuit power before installing/servicing equipment.
WARNING: To reduce the risk of fire or electric shock, do not expose the unit to rain or moisture.
This installation should be made by qualified service personnel and should conform to the National
Electrical Code and all local codes.
Terminal Identification:
PD8/PD8CB - Power Distribution Module
Terminal Legend Function/Description
1P - 8P AC output.
1N - 8N AC output.
PD16W/PD16WCB - Power Distribution Module
Terminal Legend Function/Description
1P - 16P AC output.
1N - 16N AC output.
ALTV2416 series - 3 -