Alto Shaam ES GAS SERIES Operation Manual

C o m b i n a t i o n
O v e n / S t e a m e r
ES GAS
SERIES
6•10ESG
10•10ESG
7•14ESG 10•20ESG 12•18ESG 20•20ESG
P RI N TE D I N U .S .A .
I NSTALLATION
W 1 64 N 9 22 1 Wa t er S t re et • P.O. B ox 4 50 • Me n omo n ee F all s , Wis c ons i n 5 3 052 - 0 450 USA
WEBSITE: www.alto-shaam.com
#MN-28898 • 03/09
Ge n eral In f or mation
Delivery / Unpacking . . . . . . . . . . . . . . . . . . 1.
Safety Proce dure s a nd Prec auti ons . . . . . . . . . 2.
Sp e cifica tions
Options . . . . . . . . . . . . . . . . . . . . . . . . . . .3.
6•10esG . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.
10•10esG . . . . . . . . . . . . . . . . . . . . . . . . . .5.
7•14esG . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.
10•20esG . . . . . . . . . . . . . . . . . . . . . . . . . .7.
12•18esG . . . . . . . . . . . . . . . . . . . . . . . . . .8.
20•20esG . . . . . . . . . . . . . . . . . . . . . . . . . .9.
In s tallat ion Requ ir ements
Installation Codes & Stan dards . . . . . . . . . . .10.
Ventilation General Require ment s . . . . . . . . . 11.
Positioning on Site . . . . . . . . . . . . . . . . . . .11.
Minimum Clearance Requi reme nts . . . . . . . .11.
Positioning Requirements . . . . . . . . . . . . . .12 .
Ventilation Specific Requiremen ts . . . . . . . . .1 3.
Electrical Requireme nts . . . . . . . . . . . . . . . .14.
Drip Tray In stal lati on . . . . . . . . . . . . . . . . .15.
Mobile Equip ment Re stra int . . . . . . . . . . . . .15.
Gas Supply Specifications . . . . . . . . . . . . . .16.
Gas Pressure s . . . . . . . . . . . . . . . . . . . . . .1 6.
Gas Connection . . . . . . . . . . . . . . . . . . . . .1 7.
Gas Leak Testing . . . . . . . . . . . . . . . . . . . .19.
Gas Exhaust . . . . . . . . . . . . . . . . . . . . . . .19.
Water Quality Requ irem ents . . . . . . . . . . . . . 20.
Water Connectio n . . . . . . . . . . . . . . . . . . .21.
Water Filtratio n S yste m . . . . . . . . . . . . . . . .22.
Water Drainage . . . . . . . . . . . . . . . . . . . . .23.
In s tallat ion Chec k list . . . . . . . . . . . . . . . . .24.
Er r o r Codes
Control Reset . . . . . . . . . . . . . . . . . . . . . . 25.
Error Codes . . . . . . . . . . . . . . . . . . . . . . .25.
Emergency Operation . . . . . . . . . . . . . . . . .28.
Eq u ipment L imited War r anty . . . . . . . . . . .29.
Tra n sporta t ion Dam a ge and Cl a ims . . . . . . 30.
D E L I V E R Y
This Alto-Shaam appliance has been thoroughly tested and inspected to insure only the highest quality unit is provided. Upon receipt, check for any possible shipping damage and report it at once to the delivering carrier. See
Transportation Damage and Claims section
located in this manual.
This appliance, complete with unattached items and accessories, may have been delivered in one or more packages. Check to ensure that all standard items and options have been received with each model as ordered.
Save all the information and instructions packed with the appliance. Complete and return the warranty card to the factory as soon as possible to assure prompt service in the event of a warranty parts and labor claim.
This manual must be read and understood by all people using or installing the equipment model. Contact the Alto-Shaam service department if you have any questions concerning installation, operation, or maintenance.
NOT E : All claims for warranty must include the
full model number and serial number of the unit.
U N P A C K I N G
1. Carefully remove the appliance from the carton or crate.
NOT E : Do not discard the
carton and other packaging material until you have inspected the unit for hidden damage and tested it for proper operation.
2. Read all instructions in this manual carefully before initiating the installation of this appliance.
DO NOT DISCARD THIS MANUAL. This manual is considered to be part of the appliance and is to be provided to the owner or manager of the business or to the person responsible for training operators. Additional
manuals are available from the Alto-Shaam
service department.
3. Remove all protective plastic film, packaging materials, and accessories from the appliance before connecting electrical power. Store any accessories in a convenient place for future use.
®
®
®
C A U T I O N
TO PREVENT PERSONAL INJURY,
USE CAUTION WHEN MOVING OR
LEVELING THIS APPLIANCE.
THE I NFORM AT I ON C O NTAI N E D IN THIS
MANU A L IS IMPORTA N T F O R TH E PROP E R INSTA L L ATIO N OF T HIS O VEN. PLEA S E
READ CARE F U L LY AND RETA I N FO R FUTU R E RE F E R E N CE.
IMPR O P E R C O N N E CTION OF T H IS A P PLIAN C E WILL NULL I F Y AL L WA R R A NTIE S .
G A S C OM BI TH ER M I NS TA LL AT IO N M AN UA L #MN-28898
LES I NFORM AT I ONS C ONTEN U E S D A N S CE
MANU E L SO N T IMP O R TA N T ES P O UR LI NSTA L L AT ION LU T ILISAT I O N E T LE NTRET I E N D D E CE FOUR. SI L VOU S PLAI T LIS E Z -L E T R E S AT T ENTIV E M E N T E T CONS E R V E Z -LE.
LA N O N-APP L I C ATIO N DE C ES C O N SIGN E S ANNU L E TO U T E S G A R A N TIES.
PG.1
1. This appliance is intended to cook, hold or
process foods for the purpose of human consumption. No other use for this appliance is authorized or recommended.
2. This appliance is intended for use in commercial
establishments where all operators are familiar with the purpose, limitations, and associated hazards of this appliance. Operating instructions and warnings must be read and understood by all operators and users.
3. Any troubleshooting guides, component views,
and parts lists included in this manual are for general reference only and are intended for use by qualified technical personnel.
4. This manual should be considered a permanent
part of this appliance. This manual and all supplied instructions, diagrams, schematics, parts lists, notices, and labels must remain with the appliance if the item is sold or moved to another location.
N O T E : Used to notify personnel of
installation, operation, or maintenance information that is important but not hazard related.
C A U T I O N
Used to indicate the presence of a hazard that can or will cause minor personal injury, property damage, or a potential unsafe practice if the warning included with this symbol is ignored.
C A U T I O N
Used to indicate the presence of a hazard that can or will cause minor or moderate personal injury or property damage if the warning included with this symbol is ignored.
D A N G E R
Used to indicate the presence of a hazard that WILL cause severe personal injury, death, or substantial property damage if the warning included with this symbol is ignored.
W A R N I N G
Used to indicate the presence of a hazard that CAN cause personal injury, possible death, or major property damage if the warning included with this symbol is ignored.
SAFETY P R O CEDURES AND PRE C A U T IONS
Knowledge of proper procedures is essential to the safe operation of electrically and/or gas energized equipment. In accordance with generally accepted product safety labeling guidelines for potential hazards, the following signal words and symbols may be used throughout this manual.
C A U T I O N
WHEN WELDING ANY STAINLESS STEEL COMPONENTS ON THIS APPLIANCE, THE ELECTRONIC CONTROL BOARDS MUST BE ISOLATED FROM THE APPLIANCE.
PG.2
G A S C OM BI TH ER M I NS TA LL AT IO N M AN UA L #MN-28898
®
COMBITHERM
COMBIGUARD™ TRIPLE-GUARD WATER
FILTRATION SYSTEM
(I NC LUDES 1 CARTR ID GE) FI-23014 COMBIGUARDREPLACEMENT FILTER FI-26356
FRY BASKET, 12" X 20" (325mm x 530mm) BS-26730
GRILLING GRATE,
12" X 20" (325mm x 530mm) SH-26731 COMBITHERM CLEANING LIQUID CE-24750
SP EC IALLY FO RM ULATED FOR COM BIT HE RM OV ENS
T WELVE (12) C ONTAINER S/CASE, 1 QUART (C. 1 L ITER) EA CH
COMBITHERM CLEANING TABS CE-28892
SP EC IALLY FO RM ULATED FOR COM BIT HE RM OV ENS
T WO (2) CO NTAIN ERS/B OX, 90 PAC KETS EAC H C ONTAIN ER
QUICK DISCONNECT KIT CR-33543
SCALE FREE
CE-27889
(C IT RUS B ASED, NO N-C OR ROSIV E D EL IMING PR OD UCT)
CA SE = F OUR 4-LB BO TTLES ; 4-L B B OTT LE MA KES 10 G ALLON S
SERVICE START-UP CHECK SP EC IFY AS RE QUIRED
AVAILA BL E TH ROUG H AN ALTO -SHAA M FAS TEAM C ENTE R
Computer Software Options 5005676
Not available on S-Con tr ol Mode ls.
RE FE R TO HAC CP SPEC IFICATIO N S HE ET #9015
FO R AP PLICA BLE PART NUMB ERS
HACCP Documentation
COMMON SPECIFICATIONS
Six (6) Chicken Roasting Rack
(PAN N OT I NCLUDED ) SH-23000
Ten (10) Chicken Roasting Rack
SH-22634
HACCP Documentation with Kitchen Management
Wireless HACCP Documentation with
Kitchen Management
IEEE 80 2. 11b STANDARDS
Fry Basket BS-26730
Grilling Grate SH-26731
G A S C OM BI TH ER M I NS TA LL AT IO N M AN UA L #MN-28898
PG.3
®
6•10ESG SPECIFICATIONS
5-1/2" (140mm)
Steam
Vent
(Top)
Untreated Water Intake (Bottom)
Treated Water Intake (Bottom)
Electrical
Connection (Bottom)
Gas Connection
(Bottom)
2" (50mm)
47-5/16" (1201mm)
42-1/16" (1068mm)
40-1/8"
(1018mm)
37" (939mm)
34-5/16" (871mm)
Water Drain
(Bottom)
21-11/16"
(550mm)
5-1/2"
(140mm)
25"
(635mm)
7-1/2"
(191mm)
58-3/16" (1478mm)
6-1/4" (159mm)
5" (125mm)
3-1/16"
(76mm)
27-3/4"
(704mm)
34" (863mm)
2-3/8" (60mm)
10-5/8
"
(270mm)
19-3/8"
(492mm)
11-1/2" (292mm)
3-5/8"
(92mm)
15-5/8" (396mm) Water Drain (Side Back)
D I M E N S I O N S : H x W x D
EX TE RIOR
:
34" x 42-1/16" x 37" (863mm x 1068mm x 939mm)
EX TE RIOR
WITH RE TR ACTAB LE DO OR:
34" x 46-1/16" x 37" (863mm x 1170mm x 939mm)
IN TE RIOR
:
17-3/4" x 17-3/8" x 26-13/16" (450mm x 440mm x 680mm)
COMBITHERM
C L E A R A N C E R E Q U I R E M E N T S
LE FT: 6" (152mm ) P LU S SE RVIC E AC CE SS : 18" (4 57 mm ) RE COM ME ND ED
20 " ( 508mm) F RO M H EA T P RO DU CI NG E QU IP M E N T
RI GHT: 4" (102m m) TO P: 20" (508mm) FOR AIR MOVEMENT
BA CK: 4" (102mm ) BO TTOM: 5 -1/8" (130mm) FOR LEGS
CO UN TER-TOP INSTA LL ATIONS MUST MA INTAIN 4" (102mm)
MI NI MUM C LEARANC E F ROM THE COU NTE R S UR FACE.
WAT E R R E Q U I R E M E N T S
TWO (2) COLD WATER INLETS - DRINKING QUALITY
ONE (1) TREATED WATER INLET: 3/4" NPT* ONE (1) UNTREATED WATER INLET: 3/4" NPT* LINE PRESSURE: 30 to 90 psi 2.8 to 6.2 bar
WATER DRAIN: 1-1/2" CONNECTION WITH AIR GAP
* Can manifold off of one 3/4" line.
I N S TA L L AT I O N R E Q U I R E M E N T S
Oven must be installed level. Hood installation. Water supply
shut-off valve and back-flow preventer. Alternate burner orifice
is required for installation sites at elevations of 3,000 feet (914m)
above sea level.
E L E C T R I C A L 6 • 1 0 E SG 6 • 1 0 E SG / s k
VOLTAGE PHASE CYCLE/HZ AWG AMPS kW AMPS kW
110 - 120 1 50/60 2 Wire plus ground, AWG 12 5.7 0.68 9.5 1.14
W E I G H T
NE T 377 lb ES T. (171 kg) ES T.
SH IP 442 lb ES T. (200 kg) ES T.
CR ATE 40" X 45" X 40" ES T.
DI ME NSION S: (1016 x 1143 x 1016mm)
PG.4
OT HE R VO LTAGES AVAILA BLE: Range 200 — 415V — 1 or 3 ph, 50 or 60 Hz
C A PA C I T Y
FULL-SIZE PANS: 20" x 12" x 2-1/2" Six (6) Four (4)
GN 1/1: 530 x 325 x 65mm Six (6) Four (4)
HALF-SIZE SHEET PANS:* 18" x 13" x 1" Six (6) Five (5)
ON WIRE SHELVES ONLY
G A S C OM BI TH ER M IN ST AL LA T IO N M AN UA L #MN-28898
VO LUM E MA XIM UM: 45 QUA RTS (57 LI TER S)
G A S R E Q U I R E M E N T S
CO NN ECTED ENER GY LO AD: 45,000 Btu/hr
HO OK -UP: 3/4" NPT
MI NI MUM C ONNECTE D P RE SSURE : 5.5" W.C. (Natural Gas)
9" W.C. (Propane)
MA XI MUM C ONNECTE D P RESSU RE: 14" W.C.
GA S T YPE M UST BE SPE CIFI ED O N O RDER .
WAT E R Q U A L I T Y M I N I M U M S TA N D A R D S
USING A WATER SUPPLY NOT MEETING ALTO-SHAAM'S MINIMUM WATER QUALITY STANDARDS WILL VOID THIS WARRANTY. It is the responsibility of the purchaser to ensure that incoming water supply is compliant with the specifications listed through adequate treatment measures. Installation of the CombiGuard™ Water Filtration System is recommended, but this system may not address all water quality issues present.
Contaminant Inlet Water Requirements (untreated water)
Free Chlorine Less than 0.1 ppm (mg/L)
Hardness Less than 3 gpg (52 ppm)
Chloride Less than 30 ppm (mg/L)
pH 7.0 to 8.5
Alkalinity Less than 50 ppm (mg/L)
Silica Less than 12 ppm (mg/L)
Total Dissolved
Solids (tds) Less than 60 ppm
72 lb (33 kg) M AXI MUM
®
COMBITHERM
21-11/16"
(550mm)
5-1/2"
(140mm)
42-1/16" (1068mm)
40-1/8"
(1018mm)
37" (939mm)
34-5/16"
(871mm)
Water Drain
(Bottom)
5" (125mm)
3-1/16"
(76mm)
37-3/8" (949mm)
43-5/8" (1108mm)
Steam
Vent
(Top)
Untreated Water Intake (Bottom)
Electrical
Connection (Bottom)
Gas Connection
(Bottom)
2" (50mm)
47-5/16" (1201mm)
58-3/16" (1478mm)
2-3/8" (60mm)
10-5/8
"
(270mm)
19-3/8"
(492mm)
15-5/8" (396mm) Water Drain (Side Back)
25"
(635mm)
7-1/2"
(191mm)
6-1/4" (159mm)
5-1/2" (140mm)
Treated Water Intake (Bottom)
11-1/2" (292mm)
3-5/8"
(92mm)
10•10ESG SPECIFICATIONS
D I M E N S I O N S : H x W x D
EX TE RIOR
EX TE RIOR
IN TE RIOR
:
43-5/8" x 42-1/16" x 37" (1108mm x 1068mm x 939mm)
WITH RE TR ACTAB LE DO OR:
43-5/8" x 46-1/16" x 37" (1108mm x 1170mm x 939mm)
:
27-3/8" x 17-3/8" x 26-13/16" (695mm x 440mm x 680mm)
C L E A R A N C E R E Q U I R E M E N T S
LE FT: 6" (152mm ) P LU S SE RVIC E AC CE SS : 18" (4 57 mm ) RE COM ME ND ED
20 " ( 508mm) F RO M H EA T P RO DU CI NG E QU IP M E N T
RI GHT: 4" (102m m) TO P: 20" (508mm) FOR AIR MOVEMENT
BA CK: 4" (102mm ) BO TTOM: 5 -1/8" (130mm) FOR LEGS
CO UN TER-TOP INSTA LL ATIONS MUST MA INTAIN 4" (102mm)
MI NI MUM C LEARANC E F ROM THE COU NTE R S UR FACE.
WAT E R R E Q U I R E M E N T S
TWO (2) COLD WATER INLETS - DRINKING QUALITY
ONE (1) TREATED WATER INLET: 3/4" NPT* ONE (1) UNTREATED WATER INLET: 3/4" NPT* LINE PRESSURE: 30 to 90 psi 2.8 to 6.2 bar
WATER DRAIN: 1-1/2" CONNECTION WITH AIR GAP
* Can manifold off of one 3/4" line.
I N S TA L L AT I O N R E Q U I R E M E N T S
Oven must be installed level. Hood installation. Water supply
shut-off valve and back-flow preventer. Alternate burner orifice
is required for installation sites at elevations of 3,000 feet (914m)
above sea level.
G A S R E Q U I R E M E N T S
CO NN ECTED ENER GY LO AD: 68,000 Btu/hr
HO OK -UP: 3/4" NPT
MI NI MUM C ONNECTE D P RE SSURE : 5.5" W.C. (Natural Gas)
9" W.C. (Propane)
MA XI MUM C ONNECTE D P RESSU RE: 14" W.C.
GA S T YPE M UST BE SPE CIFI ED O N O RDER .
WAT E R Q U A L I T Y M I N I M U M S TA N D A R D S
USING A WATER SUPPLY NOT MEETING ALTO-SHAAM'S MINIMUM WATER QUALITY STANDARDS WILL VOID THIS WARRANTY. It is the responsibility of the purchaser to ensure that incoming water supply is compliant with the specifications listed through adequate treatment measures. Installation of the CombiGuard™ Water Filtration System is recommended, but this system may not address all water quality issues present.
Contaminant Inlet Water Requirements (untreated water)
Free Chlorine Less than 0.1 ppm (mg/L)
Hardness Less than 3 gpg (52 ppm)
Chloride Less than 30 ppm (mg/L)
pH 7.0 to 8.5
Alkalinity Less than 50 ppm (mg/L)
Silica Less than 12 ppm (mg/L)
Total Dissolved
Solids (tds) Less than 60 ppm
E L E C T R I C A L 1 0 • 1 0 E S G 1 0 • 1 0 E S G / s k
VOLTAGE PHASE CYCLE/HZ AWG AMPS kW AMPS kW
110 - 120 1 50/60 2 Wire pl us ground, AWG 12 5.7 .68 9.5 1.14
W E I G H T
NE T 490 lb ES T. (222 kg) ES T.
SH IP 530 lb ES T. (240 kg) ES T.
CR ATE 50" X 45" X 40" ES T.
DI ME NSION S: (1270 x 1143 x 1016mm)
OT HE R VO LTAGES AVAILA BLE: Range 200 — 415V — 1 or 3 ph, 50 or 60 Hz
C A PA C I T Y
FULL-SIZE PANS: 20" x 12" x 2-1/2" Ten (10) Eight (8)
GN 1/1: 530 x 325 x 65mm Ten (10) Eight (8)
HALF-SIZE SHEET PANS:* 18" x 13" x 1" Ten (10) Nine (9)
ON WIRE SHELVES ONLY
120 lb (54 kg) M AXI MUM
*A DDI TIO NAL WIR E S HE LVES R EQU IRE D FOR M AXI MUM C APAC ITY
G A S C OM BI TH ER M IN ST AL LA T IO N M AN UA L #MN-28898
VO LUM E MA XIM UM: 75 QUA RTS (95 LI TER S)
PG.5
®
7•14ESG SPECIFICATIONS
Water Drain
(Bottom)
25-5/8"
(650mm)
9/16"
(13mm)
8-1/2" (216mm)
42" (1066mm)
4-13/16"
(121mm)
31-3/4"
(805mm)
33-1/8"
(840mm)
7-3/16"
(181mm)
73-7/16" (1865mm)
37-5/8” (954mm)
30-1/16"
(763mm)
4-5/8" (116mm)
2" (50mm)
47-7/8" (1215mm)
22-11/16"
(575mm)
49-13/16" (1265mm)
41-3/4" (1060mm)
44-7/16" (1128mm)
55-1/16" (1398mm)
Water Drain (Side Back)
27-9/16"
(700mm)
3-9/16"
(89mm)
4-3/8" (110mm)
6”
(151mm)
17-3/8"
(441mm)
19-3/8"
(491mm)
26-3/4"
(678mm)
Steam Vent (Top)
Gas Connection
(Bottom)
Treated Water Intake (Bottom)
Untreated Water Intake (Bottom)
Electrical Connection (Bottom)
7-9/16"
12-13/16" (325mm)
(192mm)
D I M E N S I O N S : H x W x D
EX TE RIOR
:
42" x 49-13/16" x 44-7/16" (1066mm x 1265mm x 1128mm)
EX TE RIOR
WITH RE TR ACTAB LE DO OR:
42" x 53-13/16" x 44-7/16" (1066mm x 1367mm x 1128mm)
IN TE RIOR
:
23-5/8" x 25-1/4" x 33-7/8" (600mm x 640mm x 860mm)
COMBITHERM
C L E A R A N C E R E Q U I R E M E N T S
LE FT: 6" (152mm ) P LU S SE RVIC E AC CE SS : 18" (4 57 mm ) RE COM ME ND ED
RI GHT: 4" (102m m) TO P: 20" (508mm) FOR AIR MOVEMENT
BA CK: 4" (102mm ) BO TTOM: 5 -1/8" (130mm) FOR LEGS
CO UN TER-TOP INSTA LL ATIONS MUST MA INTAIN 4" (102mm)
WAT E R R E Q U I R E M E N T S
TWO (2) COLD WATER INLETS - DRINKING QUALITY
ONE (1) TREATED WATER INLET: 3/4" NPT* ONE (1) UNTREATED WATER INLET: 3/4" NPT* LINE PRESSURE: 30 to 90 psi 2.8 to 6.2 bar
* Can manifold off of one 3/4" line.
I N S TA L L AT I O N R E Q U I R E M E N T S
Oven must be installed level. Hood installation. Water supply
shut-off valve and back-flow preventer. Alternate burner orifice
is required for installation sites at elevations of 3,000 feet (914m)
above sea level.
E L E C T R I C A L 7 • 1 4 E SG 7 • 1 4 E SG / s k
VOLTAGE PHASE CYCLE/HZ AWG AMPS kW AMPS kW
110 - 120 1 50/60 2 Wire pl us ground, AWG 12 5.7 0.68 9.5 1.14
W E I G H T
NE T NO T Y ET AVAILA BL E
PG.6
SH IP NOT YET AVAILAB LE
CR ATE 48" X 56" X 50" ES T.
DI ME NSION S: (1219 x 1422 x 1473mm)
G A S R E Q U I R E M E N T S
20 " ( 508mm) F RO M H EA T P RO DU CI NG E QU IP M E N T
MI NI MUM C ONNECTE D P RE SSURE : 5.5" W.C. (Natural Gas)
MA XI MUM C ONNECTE D P RESSU RE: 14" W.C.
MI NI MUM C LEARANC E F ROM THE COU NTER S UR FACE.
WAT E R Q U A L I T Y M I N I M U M S TA N D A R D S
USING A WATER SUPPLY NOT MEETING ALTO-SHAAM'S MINIMUM WATER QUALITY STANDARDS WILL VOID THIS WARRANTY. It is the responsibility of the purchaser to ensure that incoming water supply is compliant with the specifications listed through adequate treatment measures. Installation of the
WATER DRAIN: 1-1/2" CONNECTION WITH AIR GAP
OT HE R VO LTAGES AVAILA BLE: Range 200 — 415V — 1 or 3 ph, 50 or 60 Hz
C A PA C I T Y
FULL-SIZE PANS: 20" x 12" x 2-1/2" Fourteen (14) Twelve (12)
GN 1/1: 530 x 325 x 65mm Fourteen (14) Twelve (12) GN 2/1: 650 x 530 x 65mm Seven (7) Five (5)
FULL-SIZE SHEET PANS:* 18" x 26" x 1" Seven (7) Six (6)
ON WIRE SHELVES ONLY
VO LUM E MA XIM UM: 105 QU ARTS (133 L ITE RS)
*A DDI TIO NAL WIR E S HE LVES R EQU IRE D FOR M AXI MUM C APAC ITY
G A S C OM BI TH ER M IN ST AL LA T IO N M AN UA L #MN-28898
CombiGuard™ Water Filtration System is recommended, but this system may not address all water quality issues present.
Total Dissolved
168 lb (76 kg) M AXI MUM
CO NN ECTED ENER GY LO AD: 91,000 Btu/hr
HO OK -UP: 3/4" NPT
9" W.C. (Propane)
GA S T YPE M UST BE SPE CIFI ED O N O RDER .
Contaminant Inlet Water Requirements (untreated water)
Free Chlorine Less than 0.1 ppm (mg/L)
Hardness Less than 3 gpg (52 ppm)
Chloride Less than 30 ppm (mg/L)
pH 7.0 to 8.5
Alkalinity Less than 50 ppm (mg/L)
Silica Less than 12 ppm (mg/L)
Solids (tds) Less than 60 ppm
®
COMBITHERM
45-3/16"
(1148mm)
42-9/16"
(1080mm)
22-11/16"
(575mm)
12-13/16"
(325mm)
Water Drain
(Bottom)
2-3/16" (56mm)
30-1/2"
(775mm)
44" (1118mm) 2" (50mm)
31-3/4"
(805mm)
52-11/16" (1337mm)
43-13/16" (1111mm)
8-15/16" (226mm)
6-1/4" (157mm)
49-13/16" (1265mm)
47-7/8" (1215mm)
4-3/8" (110mm) 3-9/16"
(89mm)
Water Drain (Side Back)
Steam Vent
(Top)
Electrical Connection (Bottom)
Treated Water
Intake (Bottom)
Untreated Water
Intake (Bottom)
Gas Connection
(Bottom)
4-5/8" (116mm)
2" (50mm)
55-7/16"
(1407mm)
73-13/16" (1875mm)
6" (151mm)
17-3/8"
(441mm)
19-3/8"
(491mm)
26-3/4"
(678mm)
20-5/16"
(515mm)
10•20ESG SPECIFICATIONS
D I M E N S I O N S : H x W x D
EX TE RIOR
EX TE RIOR
IN TE RIOR
:
52-11/16" x 49-13/16" x 45-3/16" (1337mm x 1265mm x 1148mm)
WITH RE TR ACTAB LE DO OR:
52-11/16" x 53-13/16" x 45-3/16" (1337mm x 1367mm x 1148mm)
:
33-7/8" x 25-1/4" x 33-7/8" (860mm x 640mm x 860mm)
C L E A R A N C E R E Q U I R E M E N T S
LE FT: 6" (152mm ) P LU S SE RVIC E AC CE SS : 18" (4 57 mm ) RE COM ME ND ED
20 " ( 508mm) F RO M H EA T P RO DU CI NG E QU IP M E N T
RI GHT: 4" (102m m) TO P: 20" (508mm) FOR AIR MOVEMENT
BA CK: 4" (102mm ) BO TTOM: 5 -1/8" (130mm) FOR LEGS
WAT E R R E Q U I R E M E N T S
TWO (2) COLD WATER INLETS - DRINKING QUALITY
ONE (1) TREATED WATER INLET: 3/4" NPT* ONE (1) UNTREATED WATER INLET: 3/4" NPT* LINE PRESSURE: 30 to 90 psi 2.8 to 6.2 bar
WATER DRAIN: 1-1/2" CONNECTION WITH AIR GAP
* Can manifold off of one 3/4" line.
I N S TA L L AT I O N R E Q U I R E M E N T S
Oven must be installed level. Hood installation. Water supply
shut-off valve and back-flow preventer. Alternate burner orifice
is required for installation sites at elevations of 3,000 feet (914m)
above sea level.
E L E C T R I C A L
VOLTAGE PHASE CYCLE/HZ AWG AMPS kW
110 - 120 1 50/60 2 Wire plus ground, AWG 12 7.8 .936
W E I G H T
NE T 573 lb ES T. (260 kg) ES T.
SH IP 875 lb ES T. (397 kg) ES T.
CR ATE 59" X 55" X 48" ES T.
DI ME NSION S: (1499 x 1397 x 1219mm)
OT HE R VO LTA GES AVA ILABL E: Range 200 — 415V — 1 or 3 ph, 50 or 60 Hz
C A PA C I T Y
FULL-SIZE PANS: 20" x 12" x 2-1/2" Twenty (20)
GN 1/1: 530 x 325 x 65mm Twenty (20) GN 2/1: 650 x 530 x 65mm Ten (10)
FULL-SIZE SHEET PANS:* 18" x 26" x 1" Ten (10)
*A DDI TIO NAL WIR E S HE LVES R EQU IRE D FOR M AXI MUM C APAC ITY
G A S C OM BI TH ER M IN ST AL LA T IO N M AN UA L #MN-28898
ON WIRE SHELVES ONLY
VO LUM E MA XIM UM: 150 QU ARTS (190 L ITE RS)
G A S R E Q U I R E M E N T S
CO NN ECTED ENER GY LO AD: 105,000 Btu/hr
HO OK -UP: 3/4" NPT
MI NI MUM C ONNECTE D P RE SSURE : 5.5" W.C. (Natural Gas)
9" W.C. (Propane)
MA XI MUM C ONNECTE D P RESSU RE: 14" W.C.
GA S T YPE M UST BE SPE CIFI ED O N O RDER .
WAT E R Q U A L I T Y M I N I M U M S TA N D A R D S
USING A WATER SUPPLY NOT MEETING ALTO-SHAAM'S MINIMUM WATER QUALITY STANDARDS WILL VOID THIS WARRANTY. It is the responsibility of the purchaser to ensure that incoming water supply is compliant with the specifications listed through adequate treatment measures. Installation of the CombiGuard™ Water Filtration System is recommended, but this system may not address all water quality issues present.
Contaminant Inlet Water Requirements (untreated water)
Free Chlorine Less than 0.1 ppm (mg/L)
Hardness Less than 3 gpg (52 ppm)
Chloride Less than 30 ppm (mg/L)
pH 7.0 to 8.5
Alkalinity Less than 50 ppm (mg/L)
Silica Less than 12 ppm (mg/L)
Total Dissolved
Solids (tds) Less than 60 ppm
240 lb (109 kg) MAX IMU M
PG.7
®
12•18ESG SPECIFICATIONS
25-5/8"
(650mm)
33-1/8"
(840mm)
45-3/16"
(1148mm)
42-9/16"
(1080mm)
22-11/16" (575mm)
12-13/16"
(325mm)
Water Drain
(Bottom)
8-1/2" (216mm)
31-3/4"
(805mm)
51-1/16" (1296mm)
43-13/16" (1111mm)
7-5/16" (184mm)
4-1/2" (114mm)
49-13/16" (1265mm)
47-7/8" (1215mm)
4-3/8" (110mm) 3-9/16"
(89mm)
Water Drain (Side Back)
Steam Vent
(Top)
Electrical Connection (Bottom)
Treated Water
Intake (Bottom)
Untreated Water
Intake (Bottom)
Gas Connection
(Bottom)
4-5/8" (116mm)
2" (50mm)
55-7/16"
(1407mm)
73-13/16" (1875mm)
6" (151mm)
17-3/8"
(441mm)
19-3/8"
(491mm)
26-3/4"
(678mm)
20-5/16" (515mm)
7-3/16"
(181mm)
COMBITHERM
D I M E N S I O N S : H x W x D
EX TE RIOR
:
51-1/16" x 49-13/16" x 45-3/16" (1296mm x 1265mm x 1148mm)
EX TE RIOR
WITH RE TR ACTAB LE DO OR:
51-1/16" x 53-13/16" x 45-3/16" (1296mm x 1367mm x 1148mm)
IN TE RIOR
:
33-7/8" x 25-1/4" x 33-7/8" (860mm x 640mm x 860mm)
C L E A R A N C E R E Q U I R E M E N T S
LE FT: 6" (152mm ) P LU S SE RVIC E AC CE SS : 18" (4 57 mm ) RE COM ME ND ED
20 " ( 508mm) F RO M H EA T P RO DU CI NG E QU IP M E N T
RI GHT: 4" (102m m) TO P: 20" (508mm) FOR AIR MOVEMENT
BA CK: 4" (102mm ) BO TTOM: 5 -1/8" (130mm) FOR LEGS
WAT E R R E Q U I R E M E N T S
TWO (2) COLD WATER INLETS - DRINKING QUALITY
ONE (1) TREATED WATER INLET: 3/4" NPT* ONE (1) UNTREATED WATER INLET: 3/4" NPT* LINE PRESSURE: 30 to 90 psi 2.8 to 6.2 bar
WATER DRAIN: 1-1/2" CONNECTION WITH AIR GAP
* Can manifold off of one 3/4" line.
I N S TA L L AT I O N R E Q U I R E M E N T S
Oven must be installed level. Hood installation. Water supply
shut-off valve and back-flow preventer. Alternate burner orifice
is required for installation sites at elevations of 3,000 feet (914m)
above sea level.
G A S R E Q U I R E M E N T S
CO NN ECTED ENER GY LO AD: 105,000 Btu/hr
HO OK -UP: 3/4" NPT
MI NI MUM C ONNECTE D P RE SSURE : 5.5" W.C. (Natural Gas)
MA XI MUM C ONNECTE D P RESSU RE: 14" W.C.
GA S T YPE M UST BE SPE CIFI ED O N O RDER .
WAT E R Q U A L I T Y M I N I M U M S TA N D A R D S
USING A WATER SUPPLY NOT MEETING ALTO-SHAAM'S MINIMUM WATER QUALITY STANDARDS WILL VOID THIS WARRANTY. It is the responsibility of the purchaser to ensure that incoming water supply is compliant with the specifications listed through adequate treatment measures. Installation of the CombiGuard™ Water Filtration System is recommended, but this system may not address all water quality issues present.
Contaminant Inlet Water Requirements (untreated water)
Free Chlorine Less than 0.1 ppm (mg/L)
Hardness Less than 3 gpg (52 ppm)
Chloride Less than 30 ppm (mg/L)
pH 7.0 to 8.5
Alkalinity Less than 50 ppm (mg/L)
Silica Less than 12 ppm (mg/L)
Total Dissolved
Solids (tds) Less than 60 ppm
E L E C T R I C A L
VOLTAGE PHASE CYCLE/HZ AWG AMPS kW
110 - 120 1 50/60 2 Wire plus ground, AWG 12 7.8 .936
W E I G H T
NE T 666 lb ES T. (302 kg) ES T.
SH IP 865 lb ES T. (392 kg) ES T.
CR ATE 56" X 55" X 50" ES T.
DI ME NSION S: (1422 x 1397 x 1270mm)
PG.8
OT HE R VO LTA GES AVA ILABL E: Range 200 — 415V — 1 or 3 ph, 50 or 60 Hz
C A PA C I T Y
FULL-SIZE PANS: 20" x 12" x 2-1/2" Twenty-four (24)
GN 1/1: 530 x 325 x 65mm Twenty-four (24) GN 2/1: 650 x 530 x 65mm Twelve (12)
FULL-SIZE SHEET PANS:* 18" x 26" x 1" Twelve (12)
*A DDI TIO NAL WIR E S HE LVES R EQU IRE D FOR M AXI MUM C APAC ITY
G A S C OM BI TH ER M IN ST AL LA T IO N M AN UA L #MN-28898
ON WIRE SHELVES ONLY
288 lb (131 kg) MAX IMU M
VO LUM E MA XIM UM: 180 QU ARTS (228 L ITE RS)
9" W.C. (Propane)
Loading...
+ 22 hidden pages