Alto Shaam 8405 QC Installation Manual

®
INSTALLATION
OPERATION
AND
MAINTENANCE
W164 N9221 Water Street • P.O. Box 450 • Menomonee Falls, Wisconsin 53052-0450 • U.S.A.
WE BSI TE
: www.alto-shaam.com
#84 05 • 10/07
®
D E LI V ERY
®
®
U N PA C K I N G
This Alto-Shaam appliance has been thoroughly tested and inspected to insure only the highest quality unit is provided. Upon receipt, check for any possible shipping damage and report it at once to the delivering carrier. See
Transportation Damage and Claims section
located in this manual.
This appliance, complete with unattached items and accessories, may have been delivered in one or more packages. Check to ensure that all standard items and options have been received with each model as ordered.
Save all the information and instructions packed with the appliance. Complete and return the warranty card to the factory as soon as possible to assure prompt service in the event of a warranty parts and labor claim.
This manual must be read and understood by all people using or installing the equipment model. Contact the Alto-Shaam service department if you have any questions concerning installation, operation, or maintenance.
NOTE: All claims for warranty must include the
full model number and serial number of the unit.
1. Carefully remove the appliance from the carton or crate.
NOTE: Do not discard the
carton and other packaging material until you have inspected the unit for hidden damage and tested it for proper operation.
2. Read all instructions in this manual carefully before initiating the installation of this appliance.
DO NOT DISCARD THIS MANUAL.
This manual is considered to be part of the appliance and is to be provided to the owner or manager of the business or to the person responsible for training operators. Additional
manuals are available from the Alto-Shaam
service department.
3. Remove all protective plastic film, packaging materials, and accessories from the appliance before connecting electrical power. Store any accessories in a convenient place for future use.
#8405 QU IC KCHIL LE R I NS TALL ATI ON , O PERATI ON , AN D M AI NTENA NC E
Pg. 1.
®
SAF ETY PROCEDURES A N D P R E C A U T I O N S
Knowledge of proper procedures is essential to the safe operation of electrically energized equipment. In accordance with generally accepted product safety labeling guidelines for potential hazards, the following signal words and symbols may be used throughout this manual.
Used to indicate the presence of a hazard that will cause severe personal injury, death, or substantial property damage if the warning included with this symbol is ignored.
Used to indicate the presence of a hazard that can cause personal injury, possible death, or major property damage if the warning included with this symbol is ignored.
Used to indicate the presence of a hazard that can or will cause minor or moderate personal injury or property damage if the warning included with this symbol is ignored.
. This appliance is intended to cook, hold or
1
rocess foods for the purpose of human
p consumption. No other use for this appliance is authorized or recommended.
2. This appliance is intended for use in commercial establishments where all operators are familiar with the purpose, limitations, and associated hazards of this appliance. Operating instructions and warnings must be read and understood by all operators and users.
3. Any troubleshooting guides, component views, and parts lists included in this manual are for general reference only and are intended for use by qualified technical personnel.
4. This manual should be considered a permanent part of this appliance. This manual and all supplied instructions, diagrams, schematics, parts lists, notices, and labels must remain with the appliance if the item is sold or moved to another location.
NOTE:
Pg. 2.
Used to indicate the presence of a hazard that can or will cause minor personal injury, property damage, or a potential unsafe practice if the warning included with this symbol is ignored.
Used to notify personnel of installation, operation, or maintenance information that is important but not hazard related.
#8405 QU IC KCHIL LE R I NS TALL ATI ON , O PERATI ON , AN D M AI NTENA NC E
I N S TA L L A T I O N
®
ANSI/NSF 7
TO PREVENT PERSONAL INJURY, USE CAUTION WHEN MOVING OR LEVELING THIS APPLIANCE.
SIT E SELECTION
rior to moving the Quickchiller to the installation
P site, check the dimensions of doors, passageways, and ceiling heights in the areas through which the cabinet must be moved. Also check the turning radius if the cabinet must be moved around an
xisting structure. The use of a fork lift or pallet
e lift truck is required for moving and leveling most Quickchiller models.
NO TE: In certain instances, it may be
necessary to remove doors and door hardware to negotiate tight spaces.
osition the Quickchiller to allow sufficient air
P ventilation through the condensing unit(s). The rear of unit should be no closer than 6" (152 mm) to any wall or structu re.
Avoid installing the chiller immediately adjacent to fryers, charbroilers, or any other equipment producing grease laden air; heat producing equipment such as ovens and ranges; and steam discharging equipment such as steamer ovens and kettles. Do not locate the Quickchiller in direct sunlight.
Allow sufficient front clearance for serviceability and for easy maneuvering of food trolleys in and out of the cabinet.
C L E A R A N C E R E Q U I R E M E N T S
BACK: 6" (152mm) TOP: 6" (152mm)
SIDES: 4" (102mm) minimum at both sides.
18" (457mm)
FR OM HE AT P RO DUCING EQUIPME NT
MI NIMUM CLEA RA NCE
.
MODEL EXTERIOR D I M E N SI O N S : H x W X D NET WEIGHT*
QC-3 34" x 28" x 29-3/4" 350 lb
(864mm x 711mm x 756mm) (159 kg)
QC-20 42-1/2" x 52-1/2" x 38" 442 lb
(1079mm x 1334mm x 965mm) (200kg)
QC-40 70-1/4" x 38-1/2" x 39-7/8" 676 lb
QC-50 84-1/2" x 51" x 40-1/2" 1,120 lb
QC-100 95" x 51" x 40-1/2" 1,152 lb
(1784mm x 978mm x 1013mm) (307 kg)
(2146mm x 1295mm x 1029mm) (508 kg)
(2413mm x 1295mm x 1029mm) (523 kg)
*SELF-CONTAINED UNITS
5-YEAR LIMITED
WARRANTY ON SELF-CONTAINED
COMPRESSOR
Effective from date of shipment.
EXC LUDE S LABOR)
(
#8405 QU IC KCHIL LE R I NS TALL ATI ON , O PERATI ON , AN D M AI NTENA NC E
Pg. 3.
I N S TA L L A T I O N R E Q U I R E M E N T S
TO PREVENT PERSONAL INJURY, USE CAUTION WHEN MOVING OR LEVELING THIS APPLIANCE.
®
he model QC-3 is a counter mounted unit and
T must be sealed to the counter with a NSF listed silicone sealant.
For all other
models, install
the appliance on a
smooth and level floor surface. Use the
adjustable cabinet legs to level the Quickchiller.
Adjust from front-to-back and from side-to-side with the use of a spirit level to evenly distribute the cabinet weight and avoid pulling the cabinet alignment out of square.
O O R S E A L :
D
Check the door gasket to make certain it is sealing properly and that the gasket provides an even and positive seal around the entire door frame.
After leveling the cabinet of cart equipped models, check the height relationship of the roll­in cart to the cabinet. Adjust the Quickchiller height as needed to accommodate the cart and to securely close the Quickchiller door(s).
Pg. 4.
#8405 QU IC KCHIL LE R I NS TALL ATI ON , O PERATI ON , AN D M AI NTENA NC E
D R A I N A G E :
®
Q C - 3 Q C - 2 0 Q C - 4 0
EVAPORATOR PANS: NO INSTALLATION REQUIRED
Q C - 5 0 Q C - 1 0 0
ONE (1) FLOOR DRAIN:
1/2" (12,7mm) DIAMETER
A 1/2" I.D. (12,7mm) PVC pipe is furnished with each QC-50 and QC-100 model. Use PVC glue to attach the pipe into the drain opening at the rear of the unit. Insert the PVC pipe into the drain opening with a 1/4" (6mm) clockwise turn. Connect the PVC pipe to discharge through an indirect waste pipe into an open-site drain by means of a 2" (51mm) air gap. Connection must be within 10' (3m) of the unit.
WATE R D R A I N A G E
DRAIN OPENING AT REAR
NOTE: In the U.S.A., this equipment is to be
installed to comply with the Basic Plumbing Code of the Building Officials and Code Administrators International, Inc. [BOCA], and the Food Service Sanitation Manual of the Food & Drug Administration [FDA].
#8405 QU IC KCHIL LE R I NS TALL ATI ON , O PERATI ON , AN D M AI NTENA NC E
Pg. 5.
®
ELECTRICAL INSTALLATION
This appliance must be branch circuit protected with proper ampacities, in accordance with the wiring diagram. The Quickchiller must be properly grounded in accordance with the National Electrical Code and applicable local codes. Wire size for the main incoming power to the unit must match the minimum size listed in the specifications applicable to the specific Quickchiller model. For supply connections, locate the wire size listed in this manual.
Before operating the c h i l l e r, c h e c k all c a b l e connections i n the e l e c t r i c a l connection area for t i g h t n e s s since c o n n e c t i o n s can loosen during t r a n s p o r t .
N O T E : After elec trica l conne ction s have b een
com plete d, oper ate the appli ance i n any c hilli ng mode for a peri od of 15 min utes a nd rec heck t he main power con necti ons at t he terminal b lock t o mak e certa in they remain tight .
Pg. 6.
#8405 QU IC KCHIL LE R I NS TALL ATI ON , O PERATI ON , AN D M AI NTENA NC E
®
ELECTRICAL INSTALLATION
VOLTAG E PHA SE C YCL E/H Z
S E L F - C O N T A I N E D
208-240VAC 1 ph 50/60 Hz
VOLTAG E PHA SE C YCL E/H Z
S E L F - C O N T A I N E D
208-240VAC 3 ph 50/60 Hz
VOLTAG E PHA SE C YCL E/H Z
R E M O T E C O M P R E S S O R
208-240VAC 1 ph 50/60 Hz
(Cabinet Only)
Q C - 3 Q C - 2 0 Q C - 4 0 Q C - 5 0 Q C - 1 0 0
Recommended
circuit amperage:
20 amps
Recommended
wire size: 12/2 w.g.
Q C - 3 Q C - 2 0 Q C - 4 0 Q C - 5 0 Q C - 1 0 0
Recommended
circuit amperage:
20 amps
Recommended
wire size: 12/2 w.g.
O C O R D A ND P L U G
N
Recommended
circuit amperage:
30 amps
Recommended
wire size:
8/2 w.g.
Recommended
circuit amperage:
40 amps
Recommended
wire size:
8/2 w.g.
circuit amperage:
Recommended
circuit amperage:
circuit amperage:
20 amps
NOT AVAILABLE NOT AVAILABLE NOT AVAILABLE
Recommended
wire size: 12/3 w.g.
N O C O R D A N D P L U G
Q C - 3 Q C - 2 0 Q C - 4 0 Q C - 5 0 Q C - 1 0 0
Recommended
circuit amperage:
circuit amperage:
20 amps
NOT AVAILABLE NOT AVAILABLE NOT AVAILABLE
Recommended
wire size: 12/2 w.g.
Recommended
60 amps
Recommended
wire size:
6/2 w.g.
Recommended
40 amps
Recommended
wire size:
8/3 w.g.
Recommended
30 amps
Recommended
wire size: 10/2 w.g.
N O C O R D A N D P L U G
#8405 QU IC KCHIL LE R I NS TALL ATI ON , O PERATI ON , AN D M AI NTENA NC E
Pg. 7.
®
QUICKCHILLER OPERATING INTRODUCTION
The Alto-Shaam® Quickchiller™is a processing refrigeration system designed to rapidly and uniformly decrease the temperature of hot foods to either a chilled or frozen state. This process provides enhanced safety, longer storage life and
etter production efficiency.
b
Rapid reduction in the temperature of hot foods inhibits the growth of bacteria and provides a safe, five-day chilled food refrigerated storage period from the time of preparation to the time of service. Enhanced storage time offers the food service operation considerable production efficiency. As an example, a daily menu item can be reduced from daily preparation to a preparation schedule consisting of two days per week.
The Alto-Shaam Quickchiller can be effectively utilized in several types of food service programs:
1. TRADITIONAL COOK-SERVE KITCHENS —
Quick chilling can be used to help streamline production in operations where foods are prepared for immediate service. Preparation of labor intensive entrées can be scheduled for production several days before service. Chilling foods provides the ability to rethermalize these items at a later date while maintaining both safety and product quality.
2. MODIFIED COOK-CHILL OPERATIONS—
where a significant portion of food is cooked for immediate service and a smaller portion of more labor intensive, hot food items are prepared in advance, chilled and reheated when required for service.
3. FULL COOK-CHILL OPERATIONS —
where all hot food production is prepared in advance of service requirements and held in refrigerated prepared food inventories. Hot food preparation takes place over a five-day production schedule.
The Quickchiller cooling or freezing process is accomplished with the utilization of large compressors and fans that are electronically controlled through the parameters entered by the operator on the control panel located at the front of the cabinet. The Quickchiller provides the operator with the ability to chill food products to a set cavity temperature by time or by internal product temperature using one or more food probes. When the specified chill time has elapsed or the probe temperature(s) has been reached the
Quickchiller will convert to a holding mode at a temperature specified for either refrigeration or frozen product maintenance. The Quickchiller control maintains a record of the length operating time used for each current cycle. After the chill cycle has ended and the unit is maintaining a holding temperature mode, the chiller control will initiate an automatic defrost cycle when required
Pg. 8.
#8405 QU IC KCHIL LE R I NS TALL ATI ON , O PERATI ON , AN D M AI NTENA NC E
®
OPERATIONAL OVERVIEW
CHILL PROCESSING CYCLES
The Alto-Shaam Quickchiller uses high velocity cold air circulation to remove heat from prepared foods for the purpose of rapidly reducing temperatures through the danger zone and providing maximum storage life. Cold air is evenly directed across each pan from the control side of every Quickchiller model to assure rapid cooling.
The high velocity cold air produced by the Quickchiller removes insulating layers of warm moist air that surrounds hot products. The rapid removal of these insulating layers of heat reduces food temperatures significantly faster than any other method of temperature reduction and provides enhanced food safety.
Because the basic performance of the Quickchiller relies on high velocity air movement around each container of food, it is important to load the food by placing pans directly into the pan slides. Always use the pan slides to support the edges of 12" x 20" steam table pans (GN 1/1). Use a wire shelf for pan support when using 18" x 26" sheet pans; 12" x 10" steam table pans (GN 1/2); loaf pans; entree plates; and other small containers.
QUICKCHILLER OPERATION MODES
PROCESSING WITH THE USE OF PROBES
Probe usage provides chill or frozen food processing activation and termination through use of a food probe or probes inserted into the center of the food. The cycle is automatically terminated when the center of the food reaches the probe sensing temperature set by the operator. In units with multiple probes, all probes much reach the sensing temperature set by the operator to trigger automatic termination of the cycle.
PROCESSING BY TIME
The time mode provides processing activation and termination based on a timed cycle selected by the operator. Upon expiration of the timed cycle, the cabinet automatically reverts to the designated holding cycle temperature.
HOLDING
Following processing completion, a holding cycle provides a temperature of 38°F (3°C) for refrigerated storage or a frozen food storage temperature of -1°F to 10°F (-18°C to -12°C) to safely hold foods after processing. The holding cycle will also maintain a holding compartment temperature between processing cycles.
To maintain sanitation control, all
foods for quick-chill or quick-
freeze processing must be at a
temperature above 140°F (60°C)
an d must be t igh tly cov ered.
#8405 QU IC KCHIL LE R I NS TALL ATI ON , O PERATI ON , AN D M AI NTENA NC E
INITIAL QUICKCHILLER OPERATION
PRECHILLING THE CABINET
The Quickchiller should be prechilled prior to placing hot foods into the cabinet. In models equipped with a roll-in cart (trolley), always maintain an empty food cart inside the chiller when prechilling to eliminates air loss through the bottom of the chiller cabinet door. An optional Prechill Sealing Strip (Item #1004781) may also be used for this purpose.
Pg. 9.
®
OPERATIONAL ADVISORY
C A U T I O N
NEVER STACK PANS DIRECTLY ON
TOP OF EACH OTHER. STACKED
A N S WI L L R E S T R I C T AI R
P FLOW AND INCREASE CHILL PROCESSING T I M E .
Clean the Quickchiller and probes prior to use and
make certain all processing modes are operating
properly before chilling or freezing foods.
To maintain proper operation of the
Quickchiller, always allow the unit to defrost
whenever the “D EFR OST O VER DUE
warning appears in the display.
For optimum performance, allow the
Quickchiller to prechill for a minimum of
30 minutes before loading pans of food.
C A U T I O N
DEQU AT E S PACING M U S T B E
A
ALLOWED B E T W E E N PANS F O R
P R O P E R AI R CI R C U L AT I O N FOR BOTH PROCESSING AND SUBSEQUENT H O L D I N G .
Cook foods properly in preparation for blast
chilling or freezing.
Foods should be portioned into shallow pans to
a depth not to exceed 2-inches (51mm).
Pans must be covered prior to the chilling or
freezing process.
Always follow the recommended shelf life for
chilled food products. Hold chilled foods under refrigeration for a maximum of 5 days including the day of production and the day of consumption.
Never overload the Quickchiller.
It is important to be familiar with and adhere
to all local food codes.
NOTE:
THE PROCEDURE TO SET THE CORRECT DATE AND TIME IS ADDRESSED IN THE PROGRAM OPTIONS SECTION OF THIS MANUAL.
According to U.S. food code regulations, all
chilled products must be reheated to an internal temperature of 165°F (74°C) prior to serving.
A L L O W A 3 0 M I N U T E M I N I M U M P R E C H I L L T I M E .
NOT E: During the initial cooling of the Quickchiller, an evaporator fan delay system will prevent the
chilling fans from engaging until the evaporator coil temperature is below 30°F (-1°C).
Pg. 10.
#8405 QU IC KCHIL LE R I NS TALL ATI ON , O PERATI ON , AN D M AI NTENA NC E
®
OPERATIONAL ADVISORY
D OOR O PEN” will appear in the display whenever the unit is in operation and the door is opened.
When the date and time (only) is showing in the display, this message will not appear when the door is
opened. If the Quickchiller door is opened during any running chill or freeze cycle, the fans will
disengage and the compressor will cycle down. When the door is closed, the fans and compressor will
reengage and the chiller will begin operating at the point of interruption.
The Quickchiller will only trigger an automatic defrost cycle during the refrigerated Hold Temp mode.
If the chiller is in any other mode when the 6-hour Fan Timer limit plus one additional hour has elapsed, the
display will indicate a warning message “DE FRO ST OVERDUE” and the control will produce an audible
signal every 10 seconds until a defrost is conducted.
The audible signal can be silenced by pressing the PRO GRA M key.
P OWE R WA S OFF” will appear in the display whenever operation is interrupted by a power outage. The
control will produce an audible signal every 10 seconds and the display will indicate the amount of time the
power was off. If consecutive power outages occur before the first outage has been acknowledged, the
control will accumulate the total amount of outage time up to a period of 23 hours. After a period of 24
hours, accumulated time will be shown as greater than 24 hours, i.e., >24.
Press the PROGRAM key START/STOP key, or POWER key to clear the display and stop the audible signal.
NOTE: If the Quickchiller door is opened during any running chill or freeze cycle, the fans will disengage
and the compressor will cycle down. When the door is closed, the fans and compressor will
reengage and the chiller will begin operating at the point of interruption.
#8405 QU IC KCHIL LE R I NS TALL ATI ON , O PERATI ON , AN D M AI NTENA NC E
Pg. 11.
®
CONTROL PANEL IDENTIFICATION
N/OFF PO WE R BUTTON
O
.
SOFT CHILL … To rapidly decrease the temperature of foods by internal product probe temperature or time within a range of 24°F to 36°F (-4°C to 2°C). Soft Chill is recommended for less dense food items that chill quickly. The mode automatically converts to a refrigerated holding temperature at the end of the chill cycle.
HOLD TEMP … The mode for refrigerated storage within a temperature range of -5°F to +40°F (-21°C to +4°C). Hold Temp offers continuous refrigerated storage without the utilization of food probes or a timer.
HARD CHILL … To rapidly decrease the temperature of foods by internal product probe temperature or time within a range of 4°F to 24°F (-16°C to -4°C). Hard Chill is recommended for more dense food items. The mode automatically converts to refrigerated holding temperature at the end of the chill cycle.
Pg. 12.
QUICK FREEZE … The mode for rapid freezing and frozen food maintenance by internal product probe temperature or time within a temperature range of
-10°F to +10°F (-23°C to -12°C). The mode automatically converts to a frozen food holding temperature at the end of the quick freeze cycle.
START/STOP…Button used to initiate
operating modes, set time and temperatures, and to set specific chiller program functions.
PROGRAM…Button used to modify or
select specific chiller programming functions.
#8405 QU IC KCHIL LE R I NS TALL ATI ON , O PERATI ON , AN D M AI NTENA NC E
Loading...
+ 30 hidden pages