Alto Shaam 6.10 MARINE Installation Manual

6•10 MARINE • 06/06
W164 N9221 Water Street • P.O. Box 450 • Menomonee Falls, Wisconsin 53052-0450 USA
PHONE: 262.251.3800 • 800.558.8744 USA/CANADA FAX: 262.251.7067 • 800.329.8744 U.S.A. ONLY
WEBSITE: www.alto-shaam.com
PRINTED IN U.S. A.
6•10 MARINE Electric ML
• INSTALLATION
• MAINTENANCE
Combination
Oven / Steamer
®
COMBITHERM
ELECTRIC
INSTALLATION
Delivery & Unpacking . . . . . . . . . . . . . .1
Safety Procedures & Precautions . . . . . .2
Options & Accessories . . . . . . . . . . . . . .3
Basic Installation Site Requirements . . . . . .4
Ventilation Requirements . . . . . . . . . . .4
Positioning On Site . . . . . . . . . . . . . . . .5
Installation Requirements . . . . . . . . . . .6
Assembly Requirements . . . . . . . . . . . .7
Dimensions . . . . . . . . . . . . . . . . . . . . . .7
Water Supply . . . . . . . . . . . . . . . . . . . .8
Water Drainage . . . . . . . . . . . . . . . . . . .9
Stacking Installation . . . . . . . . . . . . . .10
Restraint Requirements - Mobile . . . . .10
Electrical Installation . . . . . . . . . . . . .11
Additional Technical Data . . . . . . . . . .12
Instructions to be Provided
to Owner/Operator . . . . . . . . . . . . .13
INSTALLATION CHECK LIST . . . . . .14
IMPORTANT SAFETY PRECAUTIONS . .15CONTROL PANEL IDENTIFICATION
• Standard and Deluxe
. . . . . . . . . . . . . .16
S Control . . . . . . . . . . . . . . . . . . . . . . .18
CLEANING & MAINTENANCE
Preventive Maintenance . . . . . . . . . . . .19
Routine Cleaning Requirements . . . . . .19
Steam Generator Flush
Standard and Deluxe . . . . . . . . . . . .20
Oven Cleaner Requirements . . . . . . . . .21
Daily Oven Cleaning
S Control . . . . . . . . . . . . . . . . . . . . .23
Standard and Deluxe . . . . . . . . . . . .24
Decalcification
S Control . . . . . . . . . . . . . . . . . . . . .26
Standard and Deluxe . . . . . . . . . . . .28
Daily Gasket Cleaning . . . . . . . . . . . . .30
EMERGENCY OPERATION . . . . . . . . . . .31
CONTROL RESET . . . . . . . . . . . . . . . . . .32
TROUBLESHOOTING . . . . . . . . . . . . . . .33
SERVICE SECTION
SERVICE VIEW • OVEN EXTERIOR . . . . . .34
SERVICE VIEW• OVEN INTERIOR . . . . . . .35
SERVICE VIEW SIDE PANEL ACCESS . . . .36
PARTS LIST
DOOR AND EXTERIOR PARTS . . . . . . . . . . . . . . .37
ELECTRICAL AND ELECTRONIC PARTS . . . . . . . . .38
MECHANICAL PARTS . . . . . . . . . . . . . . . . . . . .40
PLUMBING PARTS . . . . . . . . . . . . . . . . . . . . . .40
S CONTROL PARTS . . . . . . . . . . . . . . . . . . . . .41
WIRING SCHEMATICS
610ML . . . . . . . . . . . . . . . . . . . . . .42-45
WIRING DIAGRAMS
S Control (ALL MODELS) . . . . . . . . . . . . . . . . .45
Transportation & Damage Claims . . . . . . .46
Limited Warranty . . . . . . . . . . . . . . . . . . . .46
TABLE OF CONTENTS
COMBITHERM®INSTALLATION
6•10 MARINE COMBITHERM ELECTRIC INSTALLATION AND MAINTENANCE MANUAL
PG. 1
DELIVERY
This Alto-Shaam appliance has been
thoroughly tested and inspected to insure only the
highest quality unit is provided. Upon receipt,
check for any possible shipping damage and
report it at once to the delivering carrier. See
Transportation Damage and Claims section
located in this manual.
This appliance, complete with unattached
items and accessories, may have been delivered in
one or more packages. Check to ensure that all
standard items and options have been received
with each model as ordered.
Save all the information and instructions
packed with the appliance. Complete and return
the warranty card to the factory as soon as
possible to assure prompt service in the event of a
warranty parts and labor claim.
This manual must be read and understood by
all people using or installing the equipment
model. Contact the Alto-Shaam service
department if you have any questions concerning
installation, operation, or maintenance.
NOTE: All claims for warranty must include the
full model number and serial number of
the unit.
UNPACKING
1. Carefully remove the appliance from the carton or crate.
NOTE: Do not discard the carton and other
packaging material until you have inspected the unit for hidden damage and tested it for proper operation.
2. The oven must remain on the pallet
while being moved to the installation site by fork lift or pallet lift truck.
Note dimensions required for doorways and aisles for access of the oven and pallet to the installation site. Transport the oven in an upright and level position only. Do not tilt the oven.
With the oven on the original pallet, remove the carton and all packaging materials. Open the oven door and remove all documents and other materials from the oven interior. Remove the roll-in cart if so equipped.
3. Read all instructions in this manual carefully before initiating the installation of this appliance.
DO NOT DISCARD THIS MANUAL.
This manual is considered to be part of the appliance and is to be provided to the owner or manager of the business or to the person responsible for training operators. Additional
manuals are available from the Alto-Shaam service department.
4. Remove all protective plastic film, packaging materials, and accessories from the appliance before connecting electrical power. Store any accessories in a convenient place for future use.
®
610 MARINE COMBITHERM ELECTRIC INSTALLATION AND MAINTENANCE MANUAL
PG. 2
SAFETY PROCEDURES AND PRECAUTIONS
Knowledge of proper procedures is essential to the
safe operation of electrically and/or gas energized
equipment. In accordance with generally accepted
product safety labeling guidelines for potential
hazards, the following signal words and symbols
may be used throughout this manual.
Used to indicate the presence of a hazard that will cause severe personal injury, death, or substantial property damage if the warning included with this symbol is ignored.
Used to indicate the presence of a hazard that can cause personal injury, possible death, or major property damage if the warning included with this symbol is ignored.
Used to indicate the presence of a hazard that can or will cause minor or moderate personal injury or property damage if the warning included with this symbol is ignored.
Used to indicate the presence of a hazard that can or will cause minor personal injury, property damage, or a potential unsafe practice if the warning included with this symbol is ignored.
Used to notify personnel of
installation, operation, or
maintenance information that is
important but not hazard related.
1. This appliance is intended to cook, hold or
process foods for the purpose of human
consumption. No other use for this
appliance is authorized or recommended.
2. This appliance is intended for use in
commercial establishments where all
operators are familiar with the purpose,
limitations, and associated hazards of this
appliance. Operating instructions and
warnings must be read and understood by
all operators and users.
3. Any troubleshooting guides, component
views, and parts lists included in this manual
are for general reference only and are intended
for use by qualified technical personnel.
4. This manual should be considered a
permanent part of this appliance. This
manual and all supplied instructions,
diagrams, schematics, parts lists, notices, and
labels must remain with the appliance if the
item is sold or moved to another location.
NOTE:
610 MARINE COMBITHERM ELECTRIC INSTALLATION AND MAINTENANCE MANUAL
PG. 3
COMBITHERM®OPTIONS & ACCESSORIES
OPTIONS & ACCESSORIES
AutoClean™A fully automated oven cleaning function with 4 levels of cleaning. (Not available on S-Control models).
FACTORY INSTALLATION ONLY 5001298
➥ CLEANER FOUR (4) CONTAINERS/CASE; 1 GAL (C. 3,79 LITERS) EACH CE-26013 ➥ RINSE AGENT FOUR (4) CONTAINERS/CASE; 1 GAL (C. 3,79 LITERS) EACH CE-26014
CHICKEN GREASE TRAY 1-1/2" (38mm) DEEP WITH DRAIN 4757
CHICKEN ROASTING RACK:
6 CHICKEN CAPACITY FITS FULL-SIZE PAN: 2 RACKS PER OVEN SH-23000
8 CHICKEN CAPACITY FITS FULL-SIZE PAN: 2 RACKS PER OVEN SH-23619
DOOR, ANTI-SWING FACTORY QUOTE
DOOR HINGING, LEFT HAND FACTORY INSTALLATION ONLY CONTACT FACTORY
OVERALL WIDTH DIMENSION INCREASES BY 1-1/2" (38mm)
FRY BASKET, 12" X 20" (530mm x 325mm) BS-26730
GRILLING GRATE, 12" X 20" (530mm x 325mm) SH-26731
OVEN CLEANER SPECIALLY FORMULATED FOR COMBITHERM OVENS
TWELVE (12) CONTAINERS/CASE, 1 QUART (C. 1 LITER) EACH
CE-24750
SECURITY DEVICES
CONTACT
FACTORY
SERVICE START-UP CHECK AVAILABLE THROUGH AN AUTHORIZED ALTO-SHAAM SERVICE TECHNICIAN CONTACT FACTORY
SHELF, STAINLESS STEEL WIRE SH-2903
STACKING HARDWARE:
610 OVER 610 OR 1010, STATIONARY 5000495610 OVER 714, STATIONARY 5000629610 OVER 1018, STATIONARY 5000633610 OVER 610 OR 1010, MOBILE 5000627610 OVER 714, MOBILE 5000630610 OVER 1018, MOBILE 5000634
STAND, STAINLESS STEEL:
STATIONARY: HEIGHT 27-3/4" (705mm) WITH SHELF 15964STATIONARY: HEIGHT 27-3/4" (705mm) WITH PAN SLIDES 15960STATIONARY: HEIGHT 37-13/16" (960mm) 15962MOBILE: HEIGHT 32-3/4" (832mm) WITH SHELF 15963MOBILE: HEIGHT 32-3/4" (832mm) WITH PAN SLIDES 15961
VENTLESS HOOD FACTORY INSTALLATION ONLY 5000367
COMBIGUARD TRIPLE-GUARD WATER FILTRATION SYSTEM (INCLUDES 1 CARTRIDGE) FI-23014
COMBIGUARD REPLACEMENT FILTER FI-26356
ITEMS AVAILABLE SEPARATELY FACTORY INSTALLATION ONLY PADLOCKS NOT INCLUDED
CONTROL SECURITY PANEL, DOOR LOCK, TAMPER-PROOF SCREW PACKAGE,
FLANGED LEGS FOR FLOOR OR COUNTER BOLTING
610 MARINE COMBITHERM ELECTRIC INSTALLATION AND MAINTENANCE MANUAL
PG. 4
BASIC INSTALLATION SITE REQUIREMENTS
HOOD INSTALLATION IS REQUIRED
Installation surface must be level.
Do not install adjacent to flammable surfaces.
Deep fat fryers or similar heat producing
equipment must not be installed in the immediate vicinity of the hand shower.
The oven must remain on the pallet while being moved
to the installation site with fork lift or pallet lift truck.
Do not tilt the oven.
VENTILATION REQUIREMENTS
A steam ventilation hood is mandatory for the operation of the oven. The ventilation hood must be installed
in accordance with local building codes for steam exhaust and must protrude 12-inches to 20-inches
(300mm to 500mm) over the front side of the oven. A grease filter must be located in the protruding area of
the hood. Grease filters should be thoroughly cleaned on a regular basis following manufacturer's
instructions. Ventilation hoods must ensure an adequate amount of incoming air during operation and must
be operated whenever the combination oven/steamer is used in order to avoid the accumulation of
condensation in the hood area.
Where automatically operated appliances are vented through a ventilating hood or exhaust
system equipped with a damper or with a power means of exhaust, provisions shall be made
to allow the equipment to operate only when the damper is open to a position to properly
vent the appliance and when the power means of exhaust is in operation.
IN ACCORDANCE WITH NFPA 54 COMMONWEALTH OF MASSACHUSETTS ONLY.
If a ventless hood is to be installed, we
recommend the Combitherm Ventless Hood for the
appropriate model oven.
MODEL VHML-10 Air Movement 1200 CFM Drain Connection 3/4" (19,1mm) NPT Electrical 208-240 V.A.C. 50/60 Hz, 1 ph
240 watts, 1.0 amps
Ship Weight 126 lb (57 kg) Replacement Filters
GREASE FI-23062
CHARCOAL FI-24102
COMBITHERM®INSTALLATION
N O
T E
DO NOT store or use any flammable liquids or allow flammable vapors in the vicinity of any appliance.
610 MARINE COMBITHERM ELECTRIC INSTALLATION AND MAINTENANCE MANUAL
PG. 5
POSITIONING ON SITE
Before removing the oven from the pallet for positioning on
site, it is important to remove the drip tray to prevent
damage to the tray caused by the lifting forks. The drip tray
is fastened to the bottom of the oven with three sheet metal
screws as illustrated.
Lift the oven from the pallet with a fork lift or
pallet lift truck positioned at the front of the
oven. To avoid damage, position the lift forks to
the left of the condenser as indicated in one of
the two diagrams shown below. For additional
damage protection, the use of two wooden
boards, placed between the bottom of the oven
and the lifting forks, is strongly recommended.
After the oven is correctly positioned on site,
reattach the drip tray.
MODEL
610
NET WEIGHT
285 lb (129 kg)
15"
(381mm)
MODEL
610
CONDENSER
COMBITHERM®INSTALLATION
OBSERVE ATTENTION LABEL ON OVEN FOR
AREA TO AVOID WITH LIFTING FORK
.
MODEL
610
MARINE
WIDTH
60"
(1524mm)
DEPTH
50"
(1270mm)
HEIGHT W/PALLET
40"
(1016mm)
WEIGHT W/PALLET
495 lb
(225kg)
PALLETIZED DIMENSIONS AND WEIGHT (EST.)
TO PREVENT PERSONAL INJURY, USE CAUTION WHEN MOVING OR LEVELING THIS APPLIANCE.
610 MARINE COMBITHERM ELECTRIC INSTALLATION AND MAINTENANCE MANUAL
PG. 6
INSTALLATION REQUIREMENTS
Do not install oven adjacent to flammable
surfaces. Strictly observe all local fire
safety regulations.
In order to ensure proper ventilation, a
minimum distance of at least 6-inches
(152mm) must be kept from the control
panel side [LEFT] of the oven and any
adjoining surfaces.
NOTE: In addition to ventilation
requirements, additional clearance
is needed for service access. A
minimum distance of 18-inches
(457mm) is strongly recommended.
Allow a minimum of 4-inches (102mm) from
the right side of the oven to allow the door
to open to at least a 90° angle. Fully opened,
the door will extend up to a 225° angle. If
the oven is furnished with the retractable
door option, allow a minimum clearance of
6-1/2-inches (16cm).
Allow a minimum clearance of 4-inches
(102mm) from the back of the oven for
plumbing connections.
Allow a 20-inch (50cm) clearance at the top of
the oven for free air movement and for the
steam vent(s) located at the top [RIGHT-REAR].
Do not install the oven adjacent to heat
producing equipment such as fryers,
broilers, etc. Minimum clearance
recommended: 20-inches (50cm).
Place the Combitherm oven on a stable, LEVEL
horizontal surface. For counter-top models, the
oven stand must be level. In addition, the overall
height of the oven should be positioned so the
operating controls and shelves may be
conveniently reached from the front.
ALL INSTALLATION INSTRUCTIONS
AND REQUIREMENTS MUST BE
STRICTLY OBSERVED.
IMPROPER CONNECTION
OF THIS APPLIANCE
NULLIFIES ALL WARRANTIES.
(102mm)
4"
18"
(46cm)
MINIMUM
20"
(50cm)
4" (102mm)
RETRACTABLE DOOR OPTION:
6-1/2" (165mm)
20" (50cm)
610 MARINE COMBITHERM ELECTRIC INSTALLATION AND MAINTENANCE MANUAL
PG. 7
COMBITHERM®INSTALLATION
ASSEMBLY REQUIREMENTS
HAND SHOWER HOLDER
Fasten the hand shower holder in the holes provided on the oven using the three (3) screws packaged with the holder.
DRIP TRAY
Fasten the drip tray to the bottom of the oven using the three (3) screws as illustrated.
DIMENSIONS
2-1/2" (64mm)
COLD WATER
(241mm)
(140mm)
(BOTTOM)
5-1/2"
INTAKE
ELECTRICAL
CONNECTION
(BOTTOM)
HAND SHOWER HOSE HOOK-UP
(BOTTOM)
9-1/2"
16" (406mm)
31-1/2" (802mm)
WATER
DRAIN
(BOTTOM)
12"
(305mm)
STEAM
VENT (TOP)
6-1/2"
(165mm)
2-1/4" (57mm)
30" (757mm)
(100mm)
3-15/16"
55-1/4" (1404mm)
48" (1219mm)
44" (1120mm)
40-1/2" (1030mm)
33-1/16" (840mm)
FAILURE TO PROPERLY INSTALL THE DRIP TRAY CAN OR WILL CAUSE MAJOR EQUIPMENT DAMAGE AND WILL RESULT IN A LEAKAGE HAZARD THAT CAN CAUSE PERSONAL INJURY.
6-1/2"
(165mm)
22-5/8" (574mm)
6-1/4" (159mm)
28-7/8" (733mm)
31-1/2" (802mm)
30" (757mm)
18" (456mm)
47-9/16" (1208mm)
50-5/16" (1278mm)
610 MARINE COMBITHERM ELECTRIC INSTALLATION AND MAINTENANCE MANUAL
PG. 8
WATER SUPPLY
CONNECT TO POTABLE (DRINKABLE) COLD WATER ONLY
WATER PRESSURE REQUIREMENTS: MINIMUM 30 PSI (2 BAR)
MAXIMUM 90 PSI (6 BAR)
Flush the water line at the installation site before connecting the oven to the water supply. A shut-off valve and approved back-flow preventer must be installed when connecting the oven to the cold water intake. The water supply line must be a minimum of 3/4-inch (NPT) (19mm). A hose connector is supplied for flexible hose connection to the COLD water source. Connected water should test at hardness level of 5 to 9 grains per gallon (85 to 154 ppm). A water filtration system is recommended if the water supply is between 5 and 9 gpg of
hardness. If water tests over 18 gpg of hardness (344 ppm), the installation of a water softener to maintain oven function is strongly recommended.
PIPE SEALING TAPE (TEFLON®) MUST BE USED AT ALL CONNECTION POINTS.
The use of a pipe sealing compound is not recommended.
THE SHUT-OFF VALVE MUST BE IN THE OPEN POSITION
WHEN THE OVEN IS BEING USED.
The hand shower spray hose is installed adjacent to the cold water intake connection. A ball valve is installed on the oven for hose connection to the COLD water source. Assemble the washer and the flexible hose on the ball valve and hang the spray handle on the holder previously installed on the oven.
Alto-Shaam now offers an improved water filtration system for Combitherm®. The CombiGuard triple-guard water filtration system filters dirt, sediment, and other debris as small as 1/2 micron. This system also significantly reduces chlorine content to protect against corrosive chlorine compounds. CombiGuard improves equipment efficiency, reduces service requirements and extends the life of the Combitherm. Filtration system includes one filter cartridge. Additional cartridges (FI-26356) can be purchased separately.
COMBITHERM®INSTALLATION
ELBOW
WATER
COLD WATER DRINKING QUALITY
INDIRECT WASTE PIPE WITH AIR GAP: 1-1/2" NPT
INLET: 3/4" NPT LINE PRESSURE: 30 to 90 psi
2 to 6 bar
CHLORINE: less than 0.8 ppm CHLORIDE: less than 70 ppm
HARDNESS: 5 to 9 gpg PH R ANGE: 7.0 to 9.0
85 to 154 ppm
WATER SOFTENER SHOULD BE UTILIZED
IN HARD WATER AREAS
.
ITEM FI-23014
610 MARINE COMBITHERM ELECTRIC INSTALLATION AND MAINTENANCE MANUAL
PG. 9
COMBITHERM®INSTALLATION
WATER DRAINAGE
The oven must discharge through an indirect waste pipe by means of an air gap. The drain thread is 1-1/4-inch (32mm) NPT.
A union is required. Install a 1-1/4-inch (32mm) diameter drain line. The drain line must always be a positive gradient away from the Combitherm oven and not more than 12-inches (305mm) before an air gap.
NOTE: In the U.S.A., this equipment is to be
installed to comply with the Basic
Plumbing Code of the Building
Officials and Code Administrators
International, Inc. [BOCA], and the
Food Service Sanitation Manual of the
Food & Drug Administration [FDA].
If several units are to be connected to one drain pipe, the dimensions of the pipe must be sufficient to allow an unobstructed water drain system.
AVERAGE DRAIN WATER TEMPERATURE
149°F (65°C)
2" (51mm)
Air Gap
1-1/4" (32mm) diameter NPT
WASTE PIPE
1-1/2" to 2" minimum diameter
(c. 38mm to 51mm)
610 MARINE COMBITHERM ELECTRIC INSTALLATION AND MAINTENANCE MANUAL
PG. 10
COMBITHERM®INSTALLATION
STACKING INSTALLATION
Stacking Combitherm ovens require two (2) water connections, two (2) drain connections, and two (2) electrical connections.
If local code allows, the water and drain may be manifolded as long as the size of the water inlet is increased to 1-inch (25,4mm) and the drains include an external vent. The drawing illustrates one suggested method of a manifold installation.
3/4"
(19mm)
1"
(25,4mm)
UNION
UNION
Intake
1" (25,4mm)
VENT
15" (381mm)
1-1/4"
(32mm)
1-1/2" (38mm)
WATER INTAKE DRAIN
RESTRAINT REQUIREMENTS MOBILE EQUIPMENT
Any appliance that is not furnished with a power supply
cord but that includes a set of casters must be provided
with a tether. Adequate means must be provided to limit
the movement of this appliance without depending on or
transmitting stress to the electrical conduit. The
following requirements apply:
1. Casters must be a maximum height of 6" (152mm).
2. Two of the casters must of be the locking type.
3. Such mobile appliances or appliances on mobile stands must be
installed with the use of a flexible connector secured to the building structure.
A mounting connector for a restraining device is located on the l
ower back flange of the appliance chassis or on an oven stand,
approximately 18" (457mm) from the floor. A flexible connector is
not supplied by nor available from the factory.
RISK OF ELECTRIC SHOCK.
Appliance must be secured
to building structure.
610 MARINE COMBITHERM ELECTRIC INSTALLATION AND MAINTENANCE MANUAL
PG. 11
ELECTRICAL INSTALLATION
An electrical wiring diagram is located behind the control panel on the left side of the oven. The oven must be installed by a qualified electrician. This appliance must be branch circuit protected with proper ampacities, in accordance with the wiring diagram located in the electrical compartment of the oven. The oven must be properly grounded in accordance with the National Electrical Code and applicable local codes.
CAUTION
Wire size for the main incoming power to the unit must match the minimum size listed in the specifications applicable to the specific oven model. For supply connections, locate the wire size posted on the label located on the electrical control box cover, behind the service panel or elsewhere listed in this manual.
When connecting to a Delta-B (wild leg) on a 3-phase system, the wild leg must be connected to line 3.
Before operating the oven, check all cable connections in the electrical connection area for tightness since connections can loosen during transport.
NOTE: After both water and electrical
connections have been completed, operate the oven in any cooking mode for a period of 15 minutes and recheck the main power connections at the terminal block to make certain they remain tight.
COMBITHERM®INSTALLATION
ELECTRICAL CONNECTIONS MUST BE MADE BY A QUALIFIED SERVICE TECHNICIAN IN ACCORDANCE WITH APPLICABLE ELECTRICAL CODES.
MOTOR
Rotation Direction
Electrical
Connection
THIS APPLIANCE PROPERLY AND DAMAGE CAN OCCUR IF THE MOTOR ROTATION IS NOT CORRECT.
EXCHANGE TWO OF THE INCOMING PHASES
with
Terminal
Block
Ground
Electrical
Panel
FOLLOWING ELECTRICAL CONNECTION, THE FAN DIRECTION AS THE ARROW LOCATED ON THE OVEN FAN MOTOR.
TO CHANGE MOTOR DIRECTION,
MUST
WILL NOT
ANSI/NSF 4
ROTATE IN THE SAME
FUNCTION
.
To avoid electrical shock, this appliance MUST be adequately grounded in accordance with local electrical codes or, in the absence of local codes, with the current edition of the National Electrical Code ANSI/NFPA No. 70. In Canada, all electrical connections are to be made in accordance with CSA C22.1, Canadian Electrical Code Part 1 or local codes.
610 MARINE COMBITHERM ELECTRIC INSTALLATION AND MAINTENANCE MANUAL
PG. 12
Type of Oven counter
oven stand
Pan INCHES 6: 12" x 20"
Capacity 6: 18" x 13"
GASTRONORM 6: GN 1/1
Side Rack INCHES 2-5/8
Spacing (MILLIMETERS) (65mm)
Interior INCHES 23-1/2
Width (MILLIMETERS) (596)
Interior INCHES 21-1/16
Depth (MILLIMETERS) (535)
Interior INCHES 17-3/4
Height (MILLIMETERS) (451)
Noise
Level
Spray Hose 81-inches
Length (2050mm)
Water Consumption 5 -8 gal/hr
(
APPROX.) (20-30 l/hr)
Steam Generator
Water Consumption
0.05 gal/min
(
APPROX.) (0.2 l/min)
Steam Generator 27.7 lb/hr
Rating (APPROX.) (12.6 kg/hr)
Steam
Generator
GALLONS 1.3
Volume ( LITERS) (5)
Radiated
Heat
BTU/HR 2823
Loss (K J/H) (2981)
Latent
Heat
BTU/HR 2945
Loss (kJ/h) (3110)
Total
Heat
BTU/HR 5768
Loss (kJ/h) (6091)
Air Circulation
(WITH/WITHOUT HOOD)
cubic feet/hr 10170/8122
T=8K (m
3
/h) (288/230)
Air Circulation
(WITH/WITHOUT HOOD)
cubic feet/hr 6356/4590
x=5g/kg (m
3
/h) (180/130)
ADDITIONAL TECHNICAL DATA
610ML
MODEL
The noise emission level related to the workplace is lower than: 70 dBA
Loading...