Alto Shaam 600-LVD/PT Operation Manual

OPERATION and CARE MANUAL
®
HOT FOOD DISPLAY CABINETS
MODELS: 600-LVD
600-LVD/PT
W164 N9221 Water Street ●P.O. Box 450 ●Menomonee Falls, Wisconsin 53052-0450 U.S.A.
PHONE: 262.251.3800 FAX: 262.251.7067 • 800.329.8744 U.S.A. ONLY WEBSITE:
800.558.8744 U.S.A./CANADA 262.251.1907 INTERNATIONAL www.alto-shaam.com
PRINTED IN U.S .A .
#824 • 5/2002
— HOT DISPLAY CABINETS
®
RECEIVING AND INSPECTION
START-UP
The Alto-Shaam Holding Cabinet has been thoroughly tested, checked for calibration, and inspected to insure only the highest quality cabinet is provided. When you receive your unit, check for any possible shipping damage and report it at once to the delivering carrier.
The cabinet, complete with unattached items and accessories, may be delivered in one or more packages. Check to ensure that all the following items have been received as standard with each unit.
12: CHROME PLATED WIRE SHELVES
Save all the information and instructions packed inside the cabinet. Complete and return the warranty card to the factory as soon as possible to assure prompt service in the event of a warranty parts and labor claim.
NOTE: All claims for warranty must include the full model
number and serial number of the cabinet.
ELECTRICAL INSTALLATION
SERIAL NUMBER AND WARRANTY CODE
IDENTIFICATION MODEL NUMBER
MODEL
SERIAL NO. WATTS
VOLTS
MAXIMUM RATED VOLTAGE MAXIMUM RATED FREQUENCY
1. An identification tag is permanently mounted on the cabinet.
2. Position the unit so that the power supply cord is easily
accessible in case of an emergency.
3. Plug the cabinet into a properly grounded receptacle ONLY.
If necessary, a proper receptacle or outlet configuration, as required for this unit, must be installed by a licensed electrician in accordance with applicable, local electrical codes.
ENSURE POWER SOURCE
MATCHES VOLTAGE STAMPED
ON UNIT NAMEPLATE
EXAMPLE
xxx-xx
xxxx-xx xxxx
AC
ALTO-SHAAM INC. MILW. WI. PAT. NO. 3521030
1 PH
MAXIMUM RATED
WATTAGE
xx
HZxxx
Read all instructions in this manual thoroughly before use of this unit. Keep this manual in a safe and easily accessible area.
1. In order to maintain standards established by the National Sanitation Foundation, all counter-mounted equipment must be secured flush to the counter and the entire base sealed to the counter with NSF approved sealant or equipped with 4" (102mm) legs to provide minimum unobstructed space beneath the unit. These legs are supplied with the unit. Warranty will become null and void if these directions are not followed.
2. Before operating the unit, clean both the interior and exterior of the cabinet with a clean, damp cloth and mild soap solution. Rinse carefully.
3. Clean and install the cabinet wire shelves.
CARE and CLEANING
The cleanliness and appearance of this equipment will contribute considerably to operating efficiency and savory, appetizing food. Good equipment that is kept clean works better and lasts longer.
CLEAN THE DISPLAY CABINET DAILY:
1. Disconnect the cabinet from the power source.
2. Remove all detachable items such as wire shelves. Clean these items separately.
3. Clean the interior metal surfaces of the cabinet with a clean, damp cloth and any good alkaline or alkaline chlorinated based commercial detergent or grease solvent at the recommended strength. Use a plastic scouring pad or oven cleaner for difficult areas. Avoid the use of abrasive cleaning compounds, chloride based cleaners, or cleaners containing quaternary salts. Rinse carefully to remove all residue and wipe dry.
NOTE: Never use hydrochloric acid (muriatic acid) on
stainless steel.
4. To help maintain the protective film coating on polished stainless steel, clean the exterior of the cabinet with a cleaner recommended for stainless steel surfaces. Spray the cleaning agent on a clean cloth and wipe with the grain of the stainless steel.
5. Clean the glass with a window cleaner.
HEATING CHARACTERISTICS
The cabinet is equipped with a special, low-heat-density, heating cable. Through the Halo Heat concept, the heating cable is mounted against the walls of the warming compartment to provide an evenly applied heat source controlled by a thermostat. The design and operational characteristics of the cabinet eliminates the need for a moisture pan or a heat circulating fan. Through even heat application, the quality of a food product is maintained up to several hours.
#824 Operation & Care Manual • 1.
Always follow appropriate state or local health (hygiene) regulations regarding all applicable cleaning and sanitation requirements for equipment.
At no time should the inside or outside
of the cabinet be washed down, flooded
with water or liquid solution. NEVER
STEAM CLEAN. Do not use water
jet to clean. Severe damage
or electrical hazard could result,
voiding the warranty.
600-LVD • OPERATIONAL PROCEDURES
Thermostat Control Description and Function
HEAT
INDICATOR L.E.D.
L.E.D.1
200
!
ERROR CODE
INDICATOR L.E.D.
The L.E.D., Light Emitting Diode, referred to is an electronic
device providing illumination.
The control has a three-digit L.E.D. display. When the warming cabinet is in operation, the L.E.D. will show the chamber's internal temperature. The display will also show programming and diagnostic information.
ON/OFF Rocker Switch
The Power On/Off Rocker Switch positions may be marked with the international "I" for
POWER ON/OFF
ROCKER SWITCH
On and "O" for Off.
UP/DOWN Arrow Rocker Button
The UP/DOWN arrow rocker button is used to increase or decrease the set-point temperature. The minimum set-point temperature is 90°F (32°C) while the maximum set-point temperature is 200°F (93°C).
SET
SET Button
The SET button is used to display the current set-point temperature or program a new set-point temperature. Pushing the SET button once will display the set-point temperature value for five seconds. Holding the SET button allows the programming mode to become active.
L.E.D.1
L.E.D. Display
The L.E.D. display will show the set-point temperature value when programming, or the warming chamber's temperature when calling
200
°F
for heat. When programming a new set-point temperature, the L.E.D.1 indicator with blink. When a new set-point temperature is chosen,
CHAMBER
TEMPERATURE
L.E.D.
the Chamber Temperature L.E.D. will flash three times to confirm.
CHAMBER
TEMPERATURE
L.E.D.
INCREASE / DECREASE
BUTTON
prg
SET
TEMPERATURE
SET
BUTTON
HEAT
INDICATOR L.E.D.
!
ERROR CODE
INDICATOR L.E.D.
HEAT
INDICATOR L.E.D.
!
ERROR CODE
INDICATOR L.E.D.
!
L.E.D.1
ooo
ERROR
CODE
DISPLAY
L.E.D.1
CCC
ERROR
CODE
DISPLAY
POWER ON/OFF
ROCKER SWITCH
HEAT INDICATOR L.E.D.
The Heat Indicator L.E.D. will illuminate and remain lit while the unit is calling for heat. It will go out when the air temperature inside the warming chamber reaches the set-point temperature on the control.
ERROR CODE DISPLAYS
Open-Circuited
If "ooo" is displayed in the Error Code L.E.D., the sensor is open-circuited. Follow Trouble Shooting Guide instructions in this Operation
°F
and Care Manual.
Short-Circuited
If "CCC" is displayed in the Error Code L.E.D., the sensor is short-circuited. Follow Trouble Shooting Guide instructions in this Operation
°F
and Care Manual.
ERROR CODE INDICATOR L.E.D.
If either of the above mentioned errors codes should occur, the Error Code Indicator L.E.D. will be illuminated and remain so until error is cleared.
#824 Operation & Care Manual • 2.
600-LVD • OPERATIONAL PROCEDURES
Programming and Operating Thermostat Control
Turn Power On
Press the "ON" or "I" position of the rocker switch to turn on control.
CHANGE SET-POINT TEMPERATURE
SET
+
L.E.D.1
200
Press and hold
3 seconds. After L.E.D.1 indicator blinks, release the Set Button. The control is now in the
programming mode. DOWN arrow rocker button to change the value shown in the display. Store the value by pressing the
SET button.
The new set-point value will flash three times to confirm.
the SET button for at least
Press and hold the UP or
°F
CHAMBER
TEMPERATURE
L.E.D.
HEAT INDICATOR L.E.D.
The Heat Indicator L.E.D. will illuminate as the warming chamber calls for heat. It will extinguish when the warming chamber's interior temperature reaches the set-point.
PREHEATING THE UNIT
Always preheat the unit at 200°F (93°C) for 30 minutes before loading the merchandiser with hot food.
CAUTION
The unit should be unplugged and a qualified service technician should be consulted if any of the following situations occur:
• The Heat Indicator L.E.D. does not illuminate after normal start-up.
• The warming cabinet does not hold the temperature as set.
• The warming cabinet fails to heat with the L.E.D. illuminated.
• The cabinet heats continuously with the control “OFF”.
• Refer to Trouble Shooting Guide in this manual.
ELECTRONIC CONTROL ACCURACY
The electronic control is a precise instrument and is designed to offer trouble-free service. If you suspect the temperature inside the warming cabinet does not match the temperature indicated on the digital display, after stabilizing, follow the instructions listed below.
1. Make certain the power meets the requirements of the appliance, voltage and current rating as indicated on identification tag.
2. Verify the temperature inside the warming cabinet with a quality thermal indicator.
A. With the exception of the metal shelves, completely
empty the warming cabinet.
B. Make certain the sensor, located inside the warming
cabinet at the ceiling, is completely clean.
LOADING THE CABINET
Load the merchandiser with hot food only. The purpose of this unit is to maintain hot food at proper serving temperature. Use a food thermometer to make certain all food has reached
an internal temperature range of 140° to 160°F (60° to 71°C). Do not fill cabinet closer than 2" from the sensor. Make certain door is securely closed after loading. Reset the control
to 160°F (71°C). This will not necessarily be the final setting. Proper temperature range for the food being held will depend on the type and quantity of product. It is advisable to periodically check the internal temperature of each item to assure maintenance of proper food serving temperature.
#824 Operation & Care Manual • 3.
C. Suspend the thermal indicator in the center of the
warming cabinet.
D. Allow the temperature, set on the electronic thermostat,
to stabilize for a minimum of one hour before comparing the digital display with the reading on the thermal indicator.
DO NOT OPEN THE CABINET DOOR(S) DURING THE TEMPERATURE STABILIZATION PERIOD.
If the reading on the thermal indicator does not match the digital display within 10°F (6°C), contact a qualified service technician for appropriate action.
HOLDING GUIDELINE
Chefs, cooks and other specialized food service personnel employ varied methods of cooking. Proper holding temperatures for a specific food product must be based on the moisture content of the product, product density, volume, and proper serving temperatures. Safe holding temperatures must also be correlated with palatability in determining the length of holding time for a specific product.
Halo Heat maintains the maximum amount of product moisture content without the addition of water, water vapor, or steam. Maintaining maximum natural product moisture preserves the natural flavor of the product and provides a more genuine taste. In addition to product moisture retention, the gentle properties of Halo Heat maintain a consistent temperature throughout the cabinet without the necessity of a heat distribution fan, thereby preventing further moisture loss due to evaporation or dehydration.
In an enclosed holding environment, too much moisture content is a condition which can be relieved. A product achieving extremely high temperatures in preparation must be allowed to decrease in temperature before being placed in a controlled holding atmosphere. If the product is not allowed to decrease in temperature, excessive condensation will form increasing the moisture content on the outside of the product.
HOLDING TEMPERATURE RANGE
MEAT FAHRENHEIT CELSIUS
BEEF ROAST — Rare 140°F 60°C BEEF ROAST — Med/Well Done 160°F 71°C BEEF BRISKET 160° — 175°F 71° — 79°C CORN BEEF 160° — 175°F 71° — 79°C PASTRAMI 160° — 175°F 71° — 79°C PRIME RIB — Rare 140°F 60°C STEAKS — Broiled/Fried 140° — 160°F 60° — 71°C RIBS — Beef or Pork 160°F 71°C VEAL 160° — 175°F 71° — 79°C HAM 160° — 175°F 71° — 79°C PORK 160° — 175°F 71° — 79°C LAMB 160° — 175°F 71° — 79°C
POULTRY
CHICKEN — Fried/Baked 160°— 175° F71°— 79°C DUCK 160°— 175° F71°— 79°C TURKEY 160°— 175° F71°— 79°C GENERAL 160°— 175° F71°— 79°C
FISH/SEAFOOD
FISH — Baked/Fried 160°— 175° F71°— 79°C LOBSTER 160°— 175° F71°— 79°C SHRIMP — Fried 160°— 175° F71°— 79°C
BAKED GOODS
BREADS/ROLLS 120°— 140° F49°— 60°C
MISCELLANEOUS
CASSEROLES 160°— 175° F71°— 79°C DOUGH — Proofing 80°— 100°F27°— 38° C EGGS —Fried 150°— 160°F66°— 71°C FROZEN ENTREES 160°— 175°F71°— 79°C HORS D'OEUVRES 160°— 180°F71°— 82°C PASTA 160°— 180°F71°— 82°C PIZZA 160°— 180°F71°— 82°C POTATOES 180°F82°C PLATED MEALS 180°F82°C SAUCES 140°— 200° F60°— 93°C SOUP 140°— 200°F60°— 93°C VEGETABLES 160°— 175° F71°— 79°C
THE HOLDING TEMPERATURES LISTED ARE SUGGESTED GUIDELINES ONLY
SANITATION GUIDELINE
Food flavor and aroma are usually so closely related that it is difficult, if not impossible, to separate them. There is also an important, inseparable relationship between cleanliness and food flavor. Cleanliness, top operating efficiency, and appearance of equipment contribute considerably to savory, appetizing foods. Good equipment that is kept clean, works better and lasts longer.
Most food imparts its own particular aroma and many foods also absorb existing odors. Unfortunately, during this absorption, there is no distinction between GOOD and BAD odors. The majority of objectionable flavors and odors troubling food service operations are caused by bacteria growth. Sourness, rancidity, mustiness, stale or other OFF flavors are usually the result of germ activity.
The easiest way to insure full, natural food flavor is through comprehensive cleanliness. This means good control of both visible soil (dirt) and invisible soil (germs). A thorough approach to sanitation will provide essential cleanliness. It will assure an attractive appearance of equipment, along with maximum efficiency and utility. More importantly, a good sanitation program provides one of the key elements in the prevention of food-borne illnesses.
A controlled holding environment for prepared foods is just one of the important factors involved in the prevention of food-borne illnesses. Temperature monitoring and control during receiving, storage, preparation, and the service of foods are of equal importance.
The most accurate method of measuring safe temperatures of both hot and cold foods is by internal product temperature. A quality thermometer is an effective tool for this purpose, and should be routinely used on all products that require holding at a specific temperature. A comprehensive sanitation program should focus on the training of staff in basic sanitation procedures. This includes personal hygiene, proper handling of raw foods, cooking to a safe internal product temperature, and the routine monitoring of internal temperatures from receiving through service.
Most food-borne illnesses can be prevented through proper temperature control and a comprehensive program of sanitation. Both these factors are important to build quality service as the foundation of customer satisfaction. Safe food handling practices to prevent food­borne illness is of critical importance to the health and safety of your customers. HACCP, an acronym for Hazard Analysis (at) Critical Control Points, is a quality control program of operating procedures to assure food integrity, quality, and safety. Taking steps necessary to augment food safety practices are both cost effective and relatively simple. While HACCP guidelines go far beyond the scope of this manual, additional information is available by contacting the USDA/FDA Food-borne Illness Education Information Center at (301)504-6803.
INTERNAL FOOD PRODUCT TEMPERATURES
HOT FOODS
DANGER ZONE 40° TO 140°F(4° TO 60°C)
CRITICAL ZONE70° TO 120° F(21° TO 49° C)
SAFE ZONE 140° TO 165° F (60° TO 74° C)
COLD FOODS
DANGER ZONE ABOVE 40°F (ABOVE 4°C)
SAFE ZONE 36°F TO 40° F(2°C TO 4° C)
FROZEN FOODS
DANGER ZONE ABOVE 32°F (ABOVE 0°C)
CRITICAL ZONE0° TO 32° F(-18° TO 0°C)
SAFE ZONE 0 °F OR BELOW (-18°C OR BELOW)