Alpha VFSE1500W4P Specsheet

Product Specification Sheet APS899 - Rev. 04/2015
VFSE1500 Series QwikBUS™ Video-Intercom/Emergency StationsVFSE1500 Series QwikBUS™ Video-Intercom/Emergency Stations
387 CANAL STREET • NEW YORK • NY • 10013-1615 • Phone: 212-431-5066 • Fax: 212-431-5422387 CANAL STREET • NEW YORK • NY • 10013-1615 • Phone: 212-431-5066 • Fax: 212-431-5422
Web: www.canalalarm.comWeb: www.canalalarm.com
Copyright © 1998-2 017 Alpha Communication s® - All Righ ts Reserved.
Due to c ontinuo us product i mprovement, all col ors, sizes, materials, finishes and sp ecifications are subject to change witho ut not ice.
VFSE1500 Series QwikBUS™ Video-VFSE1500 Series QwikBUS™ Video-
Intercom/Emergency StationsIntercom/Emergency Stations
The Alpha Communicat ions® / S.T .R.™ VFSE1500X QwikBUS Series stat ions are designed to work as an apartment type open voice video-interc om st ation and with Emergency signaling capabilities, using a minimal of wiring, when used in c onjunction with our AlphaEntry™ (v3.0 or later) software and/or hardware. All
VFSE1500X stat ions in a building can be wired on only two (2)
common (loop) wires! T he QwikBUS™ syst em can support hundreds of VFSE1500X st ations on a single system. Choose from White and five (5) ot her decorator inspired finishes.
These attractive and t rim video-intercom stations easily surfac e mount right on the finished wall, or can flush mount over a model UMV1000 flush plastic housing, with model HWB mounting screws. Stations c an be changed t o desk mount with t he addition of a model TZ- VFS (White) desk adapter.
All VFSE1500X series QwikBUS™ stations selec table elect ronic tone signaling, Voice On, Door Release, Call Volume, Call Down and four (4) momentary button switches (marked '1', '2', '3' and '4').
When used with an AlphaEntry™ interface, t hese switches c an be used for additional door release, or other signaling functions, depending upon syst em configuration. All VFSE1500X series have the ability t o c onnect to an optional model ECD2 dual input wiring harness connector, which allows easy local connection to Emergency, Smoke, Pendant or ot her dry cont ac t signaling inputs.
FeaturesFeatures
4" (diagonal) flat high-resolution c olor video screen Convenient Half-Duplex Voice Operation Easy Installation - Only 2 Common (loop) Wires Required Eavesdrop Privacy - except when Emergency call is placed Clear Voice Fidelity using Electret Condenser Microphones Rugged and Reliable / Simple to Operate Mounts Surfac e, or optionally Flush or Desk mount (with optional extra cost adapters) Available in White and five (5) ot her extra cost decorator finishes
SpecificationsSpecifications
Dimensions:
All VFSE1500X series st ations are
5.30"W (135mm) x 8.45"H (215mm) x
1.25"D (32mm). All dimensions shown are for the surface wall type station.
Architects' And Engineers' SpecificationsArchitects' And Engineers' Specifications
The 2-Wire open voice video-intercom/emergency st ation(s) shall be Alpha Communications® / S.T.R.™ QwikBUSVFSE1500X in (White, Titanium, 24K Gold Plated, Crystal Glass, Stainless Steel or Anthracite) color. Station(s) shall be mounted (surface, flush or desktop), with required optional mounting components. Station(s) shall feat ure elect ret condenser microphone for clear half duplex voice fidelit y (requiring no pressing of any T alk or Listen buttons).
Monitor(s) shall include a high quality 4.0" color video sc reen (measured diagonally). Monitors using mirrors or other non-flat type screens, or coaxial cable shall not be ac c eptable. Monitor(s) shall feature controls for brightness, contrast and horizontal hold.
Stat ions that include simplex type or ot her voice technologies shall not be ac c eptable. Station shall include a Voice On, Door Release, Call Volume, Call Down, and four (4) auxiliary c alling buttons (marked '1', '2', '3' and '4'). Station(s) shall include a built-in (user selectable) elec tronic call tone signal. Stat ion(s) shall require only t wo (2) common (loop) wires for system operation, and c an be used with the optional model ECD2 dual input wiring harness connect or, for interfac ing to Emergency, Smoke, Pendant or other dry contact closure input devices and AlphaEntry™ hardware/soft ware (v3.0 or later).
Contractor shall observe all local and national electrical and building codes.