Product Specification Sheet APS925 - Rev. 08/2016
SDACT-2 Serial Dialer and Digital CommunicatorSDACT-2 Serial Dialer and Digital Communicator
42 Central Drive • Farmingdale • NY • 11735-1202 • Phone: (631) 777-5500 • Fax: (631) 777-559942 Central Drive • Farmingdale • NY • 11735-1202 • Phone: (631) 777-5500 • Fax: (631) 777-5599
TOLL-FREE: (800) 666-4800 • Web: AlphaCommunications.com • Email: info@alphacommunications.comTOLL-FREE: (800) 666-4800 • Web: AlphaCommunications.com • Email: info@alphacommunications.com
Copyright © 1998-2 016 Alpha Communication s® - All Righ ts Reserved.
Due to c ontinuo us product i mprovement, all col ors, sizes, materials, finishes and sp ecifications are subject to change witho ut not ice.
SDACT-2 Shown without the
SDACTBX-GRAY Met al Housing
Architects' And Engineers' SpecificationsArchitects' And Engineers' Specifications
The Serial Dialer Unit unit(s) shall be Alpha Communications® /
Keltron model SDACT-2, or approved equal. The SDACT-2 shall be
used in conjunct ion with an Alpha Communications® EmergencyCall (or similar) notification system, to allow alarm indication at an
on- or off-site c ent ral stat ion monitoring location.
The SDACT-2 shall have an RS232 port that will allow a string of
RS232 data to be converted t o an industry standard SIA format
for alarm event reporting. Unit shall also be provided with 2 SPDT
relays for common alarm and c ommon trouble indication.
The SDACT-2 shall be mountable right to the surface of the wall
when mounted in a the SDACTBX-GRAY junction box c abinet, and
shall require a customer supplied external phone line and jack.
Contractor shall observe all local and national electrical and
building codes.
Supported InterfacesSupported Interfaces
97P1411SD2:
COMP2 protocol @ 9600 baud - data
derived zone number - event c ode
fixed to Medical Alert (MA)
97P1412SD2:
COMP2 protocol @ 2400 baud data derived zone number - event
code fixed to Medical Alert (MA)
97P1413SD2:
COMP2 protocol @ 9600 baud data derived zone number - event
code fixed to Burg (BA)
97P1414SD2:
COMP2 protocol @ 9600 baud data derived zone and event code
97P1414SD2:
Hybrid protocol @ 9600 baud - data
derived zone number - fixed Medical
Alert (MA) event code or derived Fire
Alarm (FA) event code
SPECIAL INSTALLATION NOTESPECIAL INSTALLATION NOTE
The SDACT-2 serial dialer is typically installed adjacent or
nearby to the AlphaEntry PC Master station. If the SDACT-2
needs to be mounted in a remote location, a distance away
from the USB port on the PC Master, the installer will need to
provide a compatible serial extension cable/device.
SDACT-2 Serial Dialer and Digital CommunicatorSDACT-2 Serial Dialer and Digital Communicator
The Alpha Communications® / Keltron SDACT-2 is a unique
solution that interfac es with emergency-c all, ac cess c ontrol,
building management and other systems to enable an appropriate
and instantaneous response from personnel at a central or remot e
monitoring locat ion. The SDACT-2 provides a bridge to an on- or
off- site central stat ion-st yle digital receiver t hrough the dial-up
public switc hed telephone network (PSTN).
The SDACT-2 ac c epts pre-defined ASCIII RS232 data strings and
converts t o SIA, a standard, digital receiver-compatible, alarm
reporting format.
The most c ommon applications for the SDACT- 2 is for use with our
AlphaEntry™ and AlphaEcall™ emergency-c all systems and
devices, although it c an be used with other similar syst ems.
FeaturesFeatures
RS232 Port enables acc urate monitoring of event type and
locat ion identification
Test c ode call-in c yc les are programmable. A manual test
button is also included
Transmit s signals in industry standard SIA format
Works with a variety of alarm notification equipment
Zones 1-4 supervised EOL, suitable for fault- c ontac t
monitoring
Zones 5-7 are available for loss of AC and batt ery fail
indications, which are also reported using standard SIA
event codes
Local LEDs and audible devic es c learly indicate Serial Dialer
stat us
SpecificationsSpecifications
Dimensions (in
SDACTBX-GRAY
Housing):
Height: 14.00" (356mm)
Width: 17.00" (432mm)
Depth: 4.00" (102mm) from mounting
surface
Phone Lines:
2 RJ45 receptac les. Line seizure via
RJ31x jack (by others)
Hardwired Zone
Inputs:
7 (4-EOL resistor supervised). EOL
resistor value 10K Ohms.
Audible Device: rated at 92DB
Ringer Equivalence: .1
FCC Reg.# US: KELAL00BSDACT- 2
User Controls:
Jumper (8 t otal) and Pushbuttons:
Reset, Manual Test, Silence, Program.
Power Requirements:
Power Input - regulated or
unregulated, filtered 20.4 to 27.5VDC
Power Draw:
75mA Idle, 200mA all alarm or lamp
test
Programming and
Monitoring Port:
DB- 9F RS-232