Alpha PSDC27-5, PSDC24-12, PSDC24-1.5, AA704, AB731-F Installation Manual

...
Installation and Programming Manual
Alpha Communications® 42 Central Drive Farmingdale NY 11735-1202 Phone: 631-777-5500 Fax: 631-777-5599 Toll-Free 1-800-666-4800 www.AlphaCommunications.com info@alphacommunications.com
PRO700manual (06/2012)
1
Communication System
Pro700 Installation and Programming Manual A100K10226/04.00 Jul. 2006
Pro700
2
Table of Contents
1 GENERAL SYSTEM DESCRIPTION................................................ 4
1.1 Typical Pro700 System Users.................................................... 4
1.2 Keypad Features........................................................................ 5
2 STATIONS AND KITS....................................................................... 6
2.1 Categories.................................................................................. 6
2.2 Master Stations .......................................................................... 6
2.3 Substations................................................................................. 8
2.4 Optional Equipment and Interface Units .................................. 10
2.5 Accessories.............................................................................. 12
AA711 Desk/Wall Master Station with Display.............................6
AA702 Wall Master Station with Display....................................... 6
AA703 Industrial Master Station...................................................7
AA704 Console Master Station..................................................... 7
AA705 Heavy Industrial Master Station........................................ 7
AA706 Clean Room Station.......................................................... 8
AB708 Wall Substation with 1 direct dialing button ...................... 8
AB709 Wall Substation with 3 direct dialing buttons .................... 8
AB731, AB731-F Tamper resistant substation ............................ 9
AB731A, AB731A-F Door station substation............................... 9
BC735 Multipurpose substation.................................................. 10
GD745 Handset module .............................................................10
GH750 Multipurpose Relay Unit.................................................10
HD752 Audio, PA and Radio Interface....................................... 11
HD754 Telephone Interface........................................................ 11
FC740 10 Watt Amplifier w/ talk-back......................................... 11
DP996 Sound Detection Module ................................................ 11
LA617, LA618 and LA925 Power Supplies................................. 12
BD702 Station Kit........................................................................ 12
GF732 Wall bracket....................................................................12
BF636 Front plate frame............................................................. 12
Back boxes ................................................................................. 12
Station cords for station AA711 and AA701...............................12
KB171, KB172 Wall sockets....................................................... 12
3 INSTALLATION............................................................................... 13
3.1 General Information.................................................................. 13
3.1.1 Stations............................................................................. 13
3.1.2 Station connection............................................................ 13
3.1.3 Power supply .................................................................... 13
3.1.4 Installation cable............................................................... 13
3.1.5 Cable layout...................................................................... 14
3.1.6 Considerations.................................................................. 14
4 PROGRAMMING............................................................................. 15
4.1 General..................................................................................... 15
4.2 Subscriber Numbers................................................................. 15
4.3 Priority Station.......................................................................... 15
4.4 Group Call................................................................................15
4.5 Applications and Features........................................................ 15
4.5.1 Station type....................................................................... 15
4.5.2 Station features.................................................................15
4.5.3 Switch settings.................................................................. 16
Pro700 Installation and Programming Manual
3
5 CONNECTING STATIONS ..............................................................17
5.1 AA711 .......................................................................................17
5.2 AA702, AB708 and AB709........................................................17
5.3 AA703, AA704, AA705, BC735.................................................18
5.4 AA706, AB731, AB731-F, AB731A, AB731A-F ........................19
5.5 Call Annunciation System – CAS..............................................20
5.6 Adjusting Audio Level ...............................................................21
5.6.1 Master stations AA711, AA702, AA704, AA706................21
5.6.2 Substations AB708 and AB709.........................................21
5.6.3 Industrial stations AA703, AA704 and AA705
Multipurpose Unit BC735...................................................21
5.6.4 Substations AB731, A, F and A-F .....................................21
5.7 Sound Detection Module DP996...............................................21
5.8 Wiring Diagram, all stations ......................................................21
6 TYPICAL CONFIGURATIONS.........................................................22
6.1 Police Station, Guard – Cell Communication............................22
6.2 Police Station Door – Guard – Cell communication..................23
6.3 Police Station, Remote radio control.........................................24
6.4 Supermarket..............................................................................25
6.5 Small Industry ...........................................................................26
Important Information
7 TECHNICAL SPECIFICATIONS......................................................27
The information in this manual is based upon stations with REV. C. These stations have Software Edition HM2. For older versions of stations, please use the Guide A100K10226/02.00 Aug. 1998 or /03.00 Jan. 2002.
Old and new versions of stations will work together with all functions they can be programmed to perform. It is important to note that if the feature SILENT ALARM is to be used on the system; all stations must have the new software (rev.C).
It is especially important to note that the switch programming is different on new and old stations.
Pro700 Installation and Programming Manual
4
1 GENERAL SYSTEM DESCRIPTION
z Up to 40 subscribers z No central exchange z One speech channel z One program distribution channel z Stations with LCD display z Hands-free duplex operation z Wide range of standard and programmable features z Easy to expand z Simple installation - bus, loop and/or star cabling z Best price/performance on the market
1.1 Typical Pro700 System Users
z Small industries z Small prisons z Police stations z Warehouses z Shops/supermarkets z Petrol/Gas stations z Doctor offices z Dentist offices z Workshops z Nursing homes z Door and gate control z Schools z Private homes
Master stations
AA711
AA703
Industrial
master station
Multi purpose
GD745
AA702
AA705
Heavy industrial
m
aster station
BC735
AA704
Console
station
Substations
AB709
12-27V
AB731
Cell
station
Clean Room
AB708
AB731A
Door
statio
AA706
n
Program
distribution
Public
address
Telephone
interface
Closed radio
network
relay unit
Pro700 Installation and Programming Manual
System Features
Loud-speaking hands-free
Soft-speaking confidential
Privacy
Microphone cut-out
Manual control of speech direction (simplex)
Camp on busy / queue feature
Call-back
Hurry up
Absence registration
Display information
Call reply
Last number redial
Call to last caller
Emergency call
All call with reply
Two Group call groups with reply
Priority
Always privacy
Paging
Door opening
Program distribution (music)
Remote program distribution
External loudspeaker
Silent alarm
Direct Dial 1-key station
Direct Dial
3-key station
Direct Dial
10-key station
Clear sound reproduction
LCD display, 8 digits
Volume down Volume up
LED indicator
Blank: Free line Red: Busy line Green: In conversation Green flash: Call reply Orange: Privacy or Absence
T-key for manual speech direction
Sensitive microphone
Soft-speaking
Keypad for digit dialing
X-key for cancelling calls
1.2 Keypad Features
10-49 - Subscriber call numbers
5 - Door opening feature (only from programmed stations)
5 - Reply-back on "Doorbell" function
6 - Last number redial / Activating Silent Alarm
7 - Activate all-call
8 - Activate/reply on call-back
8 - Reply back on all/group call
9 - Activate Emergency Call
91 - Activate group-call no. 1
92 - Activate group-call no. 2
93 - Activate call reply
96 - Access the program distribution channel (music)
97 + up to 4 digits
- Storage of absence / message information
97X - Delete absence / message information
98 + call number + volume
- Activate remote program distribution
99 - Activate/deactivate the privacy function
0 - Accept a call when the station is in privacy mode
0 - Give priority stations access to a busy line
0 - Microphone cutout
0 - Hurry up
0 - Call last caller
5
Microphone mute
Pro700 Installation and Programming Manual
6
2 STATIONS AND KITS
2.1 Categories
Pro700 stations are divided into two categories:
MASTER STATIONS
- make calls to any stations by dialing its number
- receive calls from any station.
Master stations are equipped with a standard 15-button keypad. No extra feature buttons are required.
SUBSTATIONS
- make calls to a limited number of predetermined call numbers
with 1 or 3 direct call buttons
- receive calls from any station.
2.2 Master Stations
AA711 Desk/Wall Master Station with Display
z Loud-speaking hands-free communication z Soft-speaking confidential handset z Total privacy z Internal 1 Watt amplifier z The volume can be adjusted with two keys in 16 levels (32dB) z An external loudspeaker can be connected to the station's wall socket z Programmable features and extension numbers z 8 digit LCD display show caller identification and
message/absence information
z A built-in relay can be used for remote output, door lock control or
to drive external call indication
z Designed for desk use or wall-mounting using wall-bracket GF732 z Connected to an RJ45 wall socket with flexible station cord z High-grade, silver gray impact-resistant ABS plastic with a satin finish
AA702 Wall Master Station with Display
z Loud-speaking hands-free communication z Total privacy z Internal 1 Watt amplifier z The volume can be adjusted with two keys in 16 levels (32dB) z An external loudspeaker can be connected to the station's screw
terminals
z Programmable features and extension numbers z 8 digit LCD display show caller identification and
message/absence information
z Designed for wall-mounting using the BF 636 frame. z High-grade, impact-resistant ABS plastic with a satin finish
Pro700 Installation and Programming Manual
7
AA703 Industrial Master Station
z Loud-speaking hands-free communication z Surface mount, splash-proof station designed for humid, dirty and
outdoor conditions
z Shock resistant casing in durable Bayblend plastic z The front can be removed to allow easy access during installation
and service
z Internal 3 Watt amplifier z Speaker volume is adjustable with switches inside the station z The unit is prepared for connection of an external speaker z The 10 Watt power amplifier FC740 can be used with this station z A built-in relay can be used for Remote Output or Door Opener
function or to drive external call indicators
AA704 Console Master Station
z Loud-speaking hands-free communication z Well suited as a control desk station z Flush mounting in back-box 6020 or wall mounting in back-box 6030 z Keyboard foil of UV-cured PVC, resistant to numerous fluids and
chemicals
z The keyboard is equipped with an adjustable backlight z Internal 3 Watt amplifier z Speaker volume is adjustable with switches inside the station z The unit is prepared for connection of an external speaker z The 10 Watt power amplifier FC740 can be used with this station z A built-in relay can be used for Remote Output/Door Opener
function or to drive external call indicators
AA705 Heavy Industrial Master Station
z Loud-speaking hands-free communication z Surface mount, splash-proof station designed for humid, dirty and
outdoor conditions
z Noise canceling microphone for areas with extreme noise z Orange Makrolon plastic housing and a membrane film keyboard z Internal 3 Watt amplifier z Speaker volume is adjustable with switches located inside the
station.
z The unit requires connection of an external loudspeaker. z The 10 Watt power amplifier FC740 can be used with this station z A built-in relay can be used for Remote Output/Door Opener
function or to drive external call indicators
Pro700 Installation and Programming Manual
8
AA706 Clean Room Station
z Specially designed for hospital clean rooms z Flush or on-wall mounting in optional back box z Foil front with full numeric keypad including volume, simplex and
cancel buttons
z Front foil is washable using all common cleaning detergents and
chemicals
z Front material is antimicrobial treated z Built-in microphone and loudspeaker z Inputs for program distribution, remote emergency call and local
reset
z Outputs for external loudspeaker, ‘door opening’ and CAS call-in or
doorbell lamp
2.3 Substations
AB708 Wall Substation with 1 direct dialing button
z Loud-speaking hands-free communication z Designed for wall surface mounting under indoor conditions z Suitable as door station z One call button programmed for:
- "door bell" function to all programmed stations
- direct dial to station no.13
- emergency call to all stations
z Internal 1 Watt amplifier z The speaker volume can be adjusted inside the station z External loudspeaker can be connected to the station's terminals z Designed for wall surface mounting with BF 636 frame z High-grade, impact-resistant ABS plastic with a satin finish
AB709 Wall Substation with 3 direct dialing buttons
z Loud-speaking hands-free communication z Designed for wall surface mounting under indoor conditions z Suitable as door station z Three call buttons programmed for:
- "door bell" function to all programmed stations
- direct dial to stations no.11, 12 and 13, and to no. 21, 23 and
Program Distribution channel (code 96) by using X as prefix
- emergency call to all stations
z Internal 1 Watt amplifier z The speaker volume can be adjusted inside the station z External loudspeaker can be connected to the station's terminals z Designed for wall surface mounting with BF 636 frame z High-grade, impact-resistant ABS plastic with a satin finish
Pro700 Installation and Programming Manual
9
AB731, AB731-F Tamper resistant substation
z Robust, vandal proof and dust resistant designed for indoor use
- AB731 on-wall mounting
- AB731-F flush mounting
z Aluminum construction with stainless steel front plate for optimal
protection
- AB731 2 mm plate
- AB731-F 3 mm plate
z Optional back box BF934 for flush mounting in concrete etc. z Suitable in correctional institutions, prisons, police stations, parking
garages, subway stations
z One call button programmed for:
- "door bell"
- direct dial to station no.13
- CAS call-in function
- emergency call to all stations
z Internal 3 Watt amplifier z The speaker volume can be adjusted inside the station z An external loudspeaker can be connected to the station z Built in relays for Remote Output or Door Opener function z Optional Sound Detection Module DP996 can initiate a call when a
preset sound level is reached
AB731A, AB731A-F Door station substation
z Robust, vandal proof and dust resistant designed for in- or outdoor
use
- AB731A on-wall mounting
- AB731A-F flush mounting
z Aluminum construction with
1.5 mm stainless steel front plate for optimal protection
z Optional back box BF934 for flush mounting in concrete etc. z Suitable as door stations, for use in corridors, parking garages,
subway stations etc.
z One call button programmed for:
- "door bell"
- direct dial to station no.13
- CAS call-in function
- emergency call to all stations
z Internal 3 Watt amplifier z The speaker volume can be adjusted inside the station z An external loudspeaker can be connected to the station z Built in relays for Remote Output or Door Opener function z Optional Sound Detection Module DP996 can initiate a call when a
preset sound level is reached
Pro700 Installation and Programming Manual
Loading...