Alpha PK407A User Manual

COMMON
CONNECT THESE (2)
NORMALLY CLOSED
WIRES TO 16VAC (polarity not
NORMALLY OPEN
important) ON IA543 (or PK543/A) CONNECT TO TERMINALS 'K' and 'D'. ON OTHER TYPE SYSTEMS CONNECT TO
(JUMPER WIRE MUST BE USED
BETWEEN TERMINALS 'K' and '8')
JUMPER
12VAC to 16VAC DOOR OPENER OUTPUT!
INSTALLATION GUIDELINES and GENERAL INFORMATION:
1. See the specific system wiring diagram for the balance of the wiring connections required.
2. All low voltage wiring is #18 AWG, unless otherwise noted.
3. Observe all local and national electrical and building codes.
4. DO NOT exceed recommended voltages.
5. When used with a magnetic door lock, a separate DC power supply is required for the magnetic door lock.
6. Although the standard input for the PK407A is 16VAC, the PK407A will accept an input volt­age of 12VAC to 16VAC. Do not connect to 24VAC!!
TYPICAL WIRING INSTRUCTIONS
FOR PK407A SPECIALTY RELAY UNIT
42 Central Drive, Farmingdale NY 11735-1202
(631) 777-5500 Fax: (631) 777-5599
TOLL-FREE Technical Line 1-800-666-4800
Email:info@alphacommunications.com
Copyright© 1995-2012, Alpha Communications®, All Rights Reserved
Showing Normally Open and Normally Closed Form 'C' Relay Contacts
AWD009 Rev. 5 (05/2012)