SAFETY PRECAUTIONS
- Always disconnect the power supply before installing or making modifications to the device.
- installationThe and handling of these devices must be carried out by authorised personnel.
- The wiring must run at least 40 cm away from any other wiring.
- Do not overtighten the screws on the terminal block.
- I and place without projectionsnstall the monitor in a dry protected risk of drip or water .
- Do not place in humid, dusty or smoky locations, or near sources of heat.
- Before connecting the system to the mains, check the connections between the door panel,
power supply,distributorsandmonitors.
- Always follow the instructions contained in this manual.
( )
CHARACTERISTICS
*
- Hands-free monitor.
- 4.3” TFTcolourscreen.
- Monitor with simple installation (non-polarised 2 wire BUS).
- Capacitive buttons to access and select menu functions.
- .User menu
- Installer setup.
- Screen and volume settings menu.
- Start/stop communicationbutton.
- Doorrelease pushbutton.
- .StatusLEDs
- Dip switches forsetting themonitor address(call code).
SYSTEM OPERATION
- To makea call, the visitormust press the buttonof the apartment; anaudible sound indicates that
the call is being made and LED will turn on. If vocal synthesis is activated then a “call inis
progress” message will indicate a call is being made. At this moment the apartment's monitor(s)
receives the call. During the call the visitor can correct his call by pressing a push button
corresponding to a different apartment, in which case the original call is cancelled.
- Thering tone lasts for 40 seconds. Withoutalerting the visitor, their image appears on the master
monitor . : the image appears onthemonitor(withcode0to receive the call For Villakit application
“apartment 1” or monitor with code 16 if the call is in “apartment 2”) when receiving the call
without the visitor being alerted.
If the call is not answered within 40 seconds, LED will turn off and the channel will be freed.
- Toestablish communication, press button on anymonitor in the apartment. Door panelLED
will turn on. If the vocal synthesis is enabled the message "you can speak now" will be heard
confirming the communicationisactivated.
- Communication will last for one and a half minutes or until button is pressed again. When
communication has finished, LEDs and will turn off and the channel will be freed. If vocal
synthesis is activated, a “Communication is finished” message will indicate that the call is over.
- To open the door, press button during the call or communication processes: one press will
activate the lock release for five seconds and LED will also turn on for five seconds. If vocal
synthesis is activated, a “Door pen” messagewillbeindicatedonthedoorpanel.is o
- Thedescriptions ofthefunction push buttonsarefound onpage3.
( )
MONITOR DESCRIPTION
*
a
b
c
d
e
f
g
a. .Microphone
b. 4.3” TFT colour screen.
c. Close push button.
d. Menu push buttons.
e. “Do not disturb” push button/indicator.
f. Start/stop communication .function push button
During standby: Display door panel image.
Menu push buttons and status LEDs:
Menu access and function selection push button.
Menu scroll down push button.
Menu scroll up push button.
Menu back push button.
( )
Monitor address (code) setup:
*
1-apartment kit 2-apartment kits
APARTMENT 1
VESTA2
CODE 0
( )
2-apartment kit: Monitor code 16 is the last,s
1
( )
MONITOR INSTALLATION
*
APARTMENT 1
VESTA2
( )
CODE 0
dip 6 of the end of line to ON.
ARTMENT 2
AP
VESTA2
CODE 16
1
Dip6: Setsthe end of line.Setto ON in monitors wherethe video cable
terminates. Remainder settoOFF.
Dip1 Dip5:to .Set the monitoraddress(addresses0 to31)
Switches set toOFFhavea valueofzero.
The values oftheswitchesset toONareshown intheenclosedchart.
Themonitor codewill bethe sumof thevalues oftheswitches setto ON.
Surface Embedding boxLocation
1.60m
h
i
j
k
l
g. releaseDoor function push button.
During standby: Press for 10 seconds to
activate/deactivate the “doctor mode” function
(function code [9018]mustbe activated).
h. Attachment holes.
i. Horizontal cable input.
j. Con ector.n
k. BUS connection terminals.
l. Con!guration DIP switch.
Power supply .status LED
Push button: End call/communication.
During standby: Enter/exit menu mode.
“Do not disturb” function access push button.
LED on: “donotdisturb” mode activated.
LED blinking: “doctor mode” activated.
LED off:functionnotactivated.
Building
Value chart
Switch number: 1 2 3 4 5
valueON : 1 2 4 8 16
x4 30
ON
1 2 3
E : 0+ 0+ 4+0+16 =20xample
Screws supplied with the
embedding box.
ON DIP
1 2 3
4 5 6
DIP