Product Specification Sheet APS967 - Rev. 12/2015
FA-GB2/A Power Supply for GB2 SystemFA-GB2/A Power Supply for GB2 System
387 CANAL STREET • NEW YORK • NY • 10013-1615 • Phone: 212-431-5066 • Fax: 212-431-5422387 CANAL STREET • NEW YORK • NY • 10013-1615 • Phone: 212-431-5066 • Fax: 212-431-5422
Web: www.canalalarm.comWeb: www.canalalarm.com
Copyright © 1998-2 017 Alpha Communication s® - All Righ ts Reserved.
Due to c ontinuo us product i mprovement, all col ors, sizes, materials, finishes and sp ecifications are subject to change witho ut not ice.
Architects' And Engineers'Architects' And Engineers'
SpecificationsSpecifications
The GB2 series power supply unit(s) shall be
Alpha Communicat ions® / Golmar FA- GB2/A, or
approved equal. The FA-GB2/A shall provide
enough power and controls for up to 22 of t he
GB2 series monitors and one (1) door entry
panel. If more than one (1) door entry panel is
used, c ontrac tor shall furnish and install an
additional FA-GB2/A power supply.
Contractor shall observe all local and national
elect rical and building codes.
GB2 Wiring InformationGB2 Wiring Information
The GB2's system uses simple 2-conductor non-
polarized wiring making it ideal for new
installations as well as for retrofit applications.
All audio, video and dat a functions are fully
digital and using the RAP-2150 (or equivalent)
cable you can run up to 300 meters from the
entrance panel to the furthest monitor.
FA-GB2/A Power Supply for GB2 SystemFA-GB2/A Power Supply for GB2 System
The Alpha Communicat ions® / Golmar FA-GB2/A power supply is used exclusively
with the GB2 series systems. T he FA-GB2/A power supply is located between the
entry panel's BUS and the monit or's BUS.
The capac ity of t he FA-GB2/A is c urrently up to 22 monitors and one (1) entry
panel. If there is more t han one (1) entry panel, then an additional FA-GB2/A power
supply needs to be installed.
The FA-GB2/A has a relay built-in for the connect ion of t he st aircase light. This relay
is controlled from the monitors.
FeaturesFeatures
Universal AC input/full range
Protec tions: short circuit, overload and over voltage
Uses simple 2-c onduct or non-polarized (loop) wiring
Capacity up to 22 monitors and one (1) entry panel
Normally open contac t; Max. 230VAC-2A
Mounts on included DIN rail
Input Voltage: 100-240VAC
Input Frequency: 50-60 Hz
Rated output voltage: 28 VDC +/- 2V
Rated output current: 1.5A
Working T emperature: - 10°C - 50°C(14°F - 122°F)
SpecificationsSpecifications
Dimensions: 9.45"W (241mm) x 3.55"H (91mm) x 2.37"D (61mm).