Alpha 232I Specsheet

Product Specification Sheet APS285 - Rev. 07/2013
232I Indoor Keypad Station (Flush Mount)232I Indoor Keypad Station (Flush Mount)
Alpha CommunicationsAlpha Communications
42 Central Drive • Farmingdale • NY • 11735-1202 • Phone: (631) 777-5500 • Fax: (631) 777-559942 Central Drive • Farmingdale • NY • 11735-1202 • Phone: (631) 777-5500 • Fax: (631) 777-5599
TOLL-FREE: (800) 666-4800 • Web: AlphaCommunications.com • Email: info@alphacommunications.comTOLL-FREE: (800) 666-4800 • Web: AlphaCommunications.com • Email: info@alphacommunications.com
Copyright © 1998-2 016 Alpha Communication s® - All Righ ts Reserved.
Architects' And Engineers'Architects' And Engineers'
SpecificationsSpecifications
The acc ess control system shall be Alpha Communications®/IEI model 232I keypad or approved equivalent. The keypad memory shall have nonvolatile EEPROM memory for up to 120 users. Codes may be from 1-6 digits in length and digits may be repeated.
Assisted by the door position sensor input, this 1 amp Form-'C' relay shall energize if the door is opened without a valid user entry or egress input. T his output can be programmed to energize for up to 15 minutes or latch. It can be reset by a valid c ode ent ry.
The systems propped door relay can be programmed for a 1 to 15 minute time window in which the door may be held open aft er a valid entry. The system shall alert the resident to any "propped" door by energizing a 1 amp Form 'C' relay. T his output may be wired to a siren, buzzer, guard station, camera or any other device.
The lock release relay is rated a 8 amps and is tough enough to handle any locking device. Simple programming allows the output to toggle (by c ode) or time from 1 to 90 seconds.
232I Flush Mount Indoor Keypad232I Flush Mount Indoor Keypad
The 232I keypad offers field proven reliability and cost effec tive solutions for residential, commercial and industrial installations, elegant yet durable, it blends with any dec or. Designed for c ompatibility with any elect ric locking device. The keypad ac cept power from any 12-24V AC/DC supply. No separate programmer is ever necessary.
FeaturesFeatures
Lock release relay Lock release t imer Forced door alarm relay and Propped door alarm relay Alarm zone shunting relay Timed egress input 120 user capac ity Front Programming Flush mount Indoor Design
Mechanical SpecificationsMechanical Specifications
Dimensions:
(R e ad e r)
Height: 4.50" (114.3mm) Width: 1.75" (44.4mm) Depth: 1.55" (39.4mm)
Dimensions:
(P rog ra m m ing Ke ypad )
Height: 4.50" (114.3mm) Width: 2.75" (69.9mm) Depth: 2.50" (63.5mm)
Electrical SpecificationsElectrical Specifications
Voltage:
12 to 24 volts AC or DC (selected by jumper)
(No rma lly us e d with m ode l SS10 6 pi gta il o r m od e l T 1 24 0 plu g- in tra ns fo rm e r)
Current:
@12VDC 20mA typical, 50mA worst c ase @24VDC 25mA typical, 70mA worst c ase
Note:
Keypads using additional relays require an additional 15mA for eac h relay energized.
Outputs:
Main relay: 8 Amp, Form 'C' @24VDC-10 Amp surge Alarm Zone Shunting Relay: 1 Amp, Form 'C' @24VDC Forced Door Relay: 1 Amp, Form 'C' @24VDC Propped Door Relay: 1 Amp, Form 'C' @24VDC
Wire Distance: 250' between reader and elec tronics with #22AWG
Environmental SpecificationsEnvironmental Specifications
Temperature: -20°F to 130°F (- 28°C to 54°C)