Allied Telesis SB251-01 User Manual

Patch Release Note
Patch SB251-01 For SwitchBlade 4000 Series Switches and AT-9800 Series Switches

Introduction

This patch release note lists the issues addressed and enhancements made in patch SB251-01 for Software Release 2.5.1 on existing models of SwitchBlade 4000 Series Switches. Patch file details are listed in Table 1.
Table 1: Patch file details for Patch SB251-01.
Base Software Release File
Patch Release Date
Compressed Patch File Name
Compressed Patch File Size
This release note should be read in conjunction with the following documents:
SwitchBlade Documentation Set for Software Release 2.5.1 (Document
Number C613-03057-00 Rev A) and Release Note for Software Release 2.5.1 for SwitchBlade 4000 Switches available on the Documentation and Tools CD-ROM packaged with your switch, or from www.alliedtelesyn.co.nz/
documentation/documentation.html.
WARNING: Using a patch for a different model or software release may cause unpredictable results, including disruption to the network. Information in this release note is subject to change without notice and does not represent a commitment on the part of Allied Telesyn International. While every effort has been made to ensure that the information contained within this document and the features and changes described are accurate, Allied Telesyn International can not accept any type of liability for errors in, or omissions arising from the use of this information.
sb-251.rez
15-Jan-2003
sb251-01.paz
71828 bytes
Simply connecting the world
2 Patch Release Note

Features in SB251-01

PCR: 02555 Module: SWI Network affecting: No
Layer 2 filtering is now working correctly.
PCR: 02561 Module: SWI Network affecting: No
32 bit counters now only show 8 bit contents.
PCR: 02563 Module: SWI Network affecting: No
The IPM (Layer 3 Multicasting table) now updates correctly to add or delete the ingress linecard to control blade ports, and the control blade to egress linecard ports when updating forwarding.
PCR: 02568 Module: CORE Network affecting: No
The ENABLE SYSTEM SECURITY_MODE command was enabling the system security mode, but after the switch was restarted the system security mode was disabled again. Also, when NVS was re-initialised because, for example a battery had been exhausted, the system could not make an SNMP trap. These issues have been resolved.
PCR: 02576 Module: SWI Network affecting: No
When the DISABLE SWITCH PORT FLOW=PAUSE command was executed on a port or ports, they would still appear to be enabled at a higher level. This issue has been resolved.
PCR: 02396 Module: DHCP Network affecting: No
DHCP RENEW request messages are now unicast (as defined in the RFC), not broadcast.
PCR: 02575 Module: SWI Network affecting: No
VLAN tagged multicast packets were incorrectly being sent over untagged VLAN interfaces. This issue has been resolved.
PCR: 02574 Module: DVMRP Network affecting: No
Some change actions, and the resending of prune messages were not operating correctly. This issue has been resolved.
PCR: 02582 Module: SWI Network affecting: No
Pause flow control is now disabled by default on all ports. This improves performance of the switch when it is congested.
PCR: 02587 Module: OSPF Network affecting: No
When OSPF was enabled on startup, an OSPF interface would sometimes stay in the DOWN state. This issue has been resolved.
PCR: 03001 Module: SWI CLASSIFIER Network affecting: No
The following parameters have been changed CREATE CLASSIFIER, SET CLASSIFIER and SHOW CLASSIFIER commands:
The MACTYPE parameter has been changed to MACTYPE={L2UCAST|L2MCAST|L2BCAST|ANY}. This resolves an error with internal hardware tables.
Patch SB251-01 for Software Release 2.5.1
C613-10361-00 REV A
Loading...
+ 2 hidden pages