Review the following information before installing the AT-StackXG Stacking Module:
Installing the AT-StackXG Stacking Module
To install the AT-StackXG Stacking Module, perform the following procedure:
1. Remove the module from the shipping package.
AT-StackXG Stacking Module
Installation Guide
Allied Telesis, Inc.
www.alliedtelesis.com
Overview
The AT-StackXG Stacking Module allows the formation of a stacked configuration when installed in each switch in a group of AT-9400 Basic Layer 3 Gigabit Ethernet Series switches or x600 Layer 3 Gigabit Ethernet Series switches. With its two full-duplex, 12-Gbps stacking ports, the module unifies the individual switches of the stack into a single, logical unit so that the network operations of the devices, such as spanning tree, port mirroring and port trunking, encompass all of the Gigabit Ethernet ports. This can simplify network management and augment network bandwidth.
The AT-StackXG Stacking Module is sensitive to and can be damaged by electrostatic discharge. Wear a grounding device and observe electrostatic discharge precautions when installing the module in the chassis.
The AT-StackXG Stacking Module is hardware hot-swappable. You can
install or replace the module while the switch is powered on.
If the stacking module is added or replaced in an operating stack, the stack topology may change and cause the stack to reboot and interrupt network traffic.
AT-9400 Basic Layer 3 Gigabit Ethernet Switch Series
:
Do not install the module until you have read the latest version of the
AT-S63 Software Release Notes and the AT-9400 Series Stack Installation Guide.
The AT-StackXG Stacking Module is supported in the AT-9424Ts,
AT-9424Ts/XP, and AT-9448Ts/XP Basic Layer 3 Switches. All other models in the AT-9400 Series do not support the HiGig stacking feature and must be used as stand-alone switches.
Support for the AT-StackXG Stacking Module requires Version 3.0.0 or
later of the AT-S63 Management Software.
x600 Layer 3 Switch Gigabit Ethernet Switch Series
:
The AT-StackXG Stacking Module is supported in all x600 series products.
Do not install the module until you have read the latest version of the AW+
Software Release Notes and the x600 Series product documentation.
Support for the AT-StackXG Stacking Module requires software version
5.3.1 or later of AlliedWare Plus.
Package Contents
The following items are included in the shipping package. If an item is missing or damaged, contact your Allied Telesis sales representative for assistance.
One AT-StackXG Stacking Module
One AT-StackXG Stacking Cable (length - .5 m)
Installation Guide
Store the packaging material in a safe location. You must use the original shipping material if you need to return the unit to Allied Telesis.
2. Remove the blank panel from the expansion slot on the back panel of the switch by loosening the two captive screws on the panel with a cross-head screwdriver.
AT-LX44CPUCV
R
1241
Figure 2. Removing the Blank Panel from the Expansion Slot
Do not remove the blank panel from the chassis until you are ready to install a module. An open slot allows dust to enter the unit and reduces proper airflow and cooling.
3. Align the edges of the module with the guides in the slot and carefully slide the module into the chassis until it is flush with the back panel of the chassis, as shown in Figure 3. Light pressure may be needed to seat the module on the connector on the back panel of the chassis.
Do not force the module into place. Doing so may damage the connector pins on the backplane inside the chassis. If there is resistance, remove the module and reinsert it after verifying that the edges of the card are properly aligned in the guides in the chassis’ module slot.
Figure 1. AT-StackXG Stacking Module
613-001122 Rev A 1
Warranty Information
The AT-StackXG Stacking Module has a Lifetime Warranty. Go to
www.alliedtelesis.com/warranty for the specific terms and conditions of the warranty and for warranty registration.
2 3
Note
Note
A
1243
A
T
-LX44CPUCVR
AT-StackXG
Stack Por
t 1
Sta
ck Por
t 2
T-LX
AT-Sta ckXG
44CPUCV
R
Stack Po
rt 1
Stack Po
rt
2
1242
Figure 3. Installing the AT-StackXG Stacking Module
4. Secure the module to the chassis by tightening the two captive screws with a cross-head screwdriver.
5. Remove the plastic protector from the connector at one end of the stacking cable.
1244
Figure 5. Removing the Plastic Protector
6. Connect the cable to either Stack Port 1 or Stack Port 2 on the stacking module and secure by tightening the two captive thumbscrews.
7. Remove the plastic protector from the connector at the other end of the stacking cable and connect it to a Stack Port on the stacking module in the next switch of the stack. A stacking cable must crossover and connect to a different port on the next stacking module. Stack Port 1 on a module must connect to Stack Port 2 on the next module. Do not connect two Stack Port 1 ports or Stack Port 2 ports together.
Technical Specifications
Dimensions (H x W x D) 3.1 x 14.7 x 8.6 cm
(1.2 x 5.8 x 3.4 in.)
Weight 131 g (0.35 lb.)
Operating Temperature: 0° C to 40° C
(32° F to 104° F)
Storage Temperature: -25° C to 70° C
(-° 13F to 158° F)
Operating Humidity: 5% to 90% noncondensing
Storage Humidity: 5% to 95% noncondensing
Maximum Operating Altitude: 3,048 m (10,000 ft)
Maximum Nonoperating Altitude: 4,000 m (13,000 ft)
Electrical Safety and Emission Statement
Standards: This product meets the following standards when installed in compliant host equipment.
U.S. Federal Communications Commission
Radiated Energy Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with this instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Note: Modifications or changes not expressly approved of by the manufacturer or the FCC, can void your right to operate this equipment.
Figure 4. Securing the AT-StackXG Stacking Module
The remaining steps attach the stacking cable to the stacking module. If you are installing the stacking module in an AT-9400 Series Switch, do not cable the module until you have prepared the switch’s AT-S63 Management Software, as explained in the AT-9400 Series Stack Installation Guide.
If you are installing the stacking module in an x600 Series Switch, do not cable the module until you have prepared the switch’s AlliedWare Plus Software on the x600 Series Switches as explained in the x600 series AlliedWare Plus 5.3.1 Software Reference.
AT-StackXG Stacking Module LEDs
The LEDs in the group labelled Stack on the front panel of the switch display the status of the AT-StackXG Stacking Module and the stacking ports. The states of the LEDs are defined in this table.
LED State Description
Off The switch is not the master unit of the stack or
MSTR
1 and 2 L/A
PRES
Green The switch is the master unit of the stack.
Off The stacking port has not established a link to
Steady green
Flashing green
Off The expansion slot on the switch is empty.
Green The AT-StackXG Stacking Module is installed
is not a member of a stack.
another AT-StackXG Stacking Module.
The stacking port has established a link to a stacking port on another AT-StackXG Stacking Module.
The stacking port is sending or receiving packet traffic.
in the expansion slot.
Industry Canada
This Class A digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.
European Union Restrictions of the Use of Certain Hazardous Substances
This Allied Telesis RoHS-compliant product conforms to the European Union Restriction of the Use of Certain Hazardous Substances (RoHS) in Electrical and Electronic Equipment. Allied Telesis ensures RoHS conformance by requiring supplier Declarations of Conformity, monitoring incoming materials, and maintaining Manufacturing process controls.
RFI Emissions FCC Class A, EN55022 Class A, EN61000-3-2, EN61000-3-3, VCCI Class A, C-TICK,
WARNING: In a domestic environment this product may cause radio interference in which
EMC (Immunity) EN55024
Electrical Safety EN60950-1 (TUV), UL 60950-1 (
Allied Telesis is a registered trademark of Allied Telesis, Incorporated. All other product names, company names, logos or other designations mentioned herein are trademarks or registered trademarks of their respective owners.
Copyright © 2008 Allied Telesis, Inc. All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesis, Inc.
(RoHS) in Electrical and Electronic Equipment
CE
case the user may be required to take adequate measures.
)
CULUS
4 5 6
Loading...