Allied Telesis AT-EX1001SC/GM1 User Manual

Page 1
AT-EX1001SC/GM1
Gigabit Ethernet Multimode Extender
Installation Guide
PN 613-10857-00 Rev A
Page 2
Copyright  2000 Allied Telesyn International, Corp. 960 Stewart Drive Suite B, Sunnyvale CA 94085 USA
Ethernet is a registered trademark of Xerox Corporation. All other product names, company names, logos or other designations mentioned herein are trademarks or registered trademarks of their respective owners.
Allied Telesyn International, Corp. reserves the right to make changes in specifications and other information contained in this document without prior written notice. The information provided herein is subject to change without notice. In no event shall Allied Telesyn International, Corp. be liable for any incidental, special, indirect, or consequential damages whatsoever, including but not limited to lost profits, arising out of or related to this manual or the information contained herein, even if Allied Telesyn International, Corp. has been advised of, known, or should have known, the possibility of such damages.
Page 3

Electrical Safety and Emission Statement

Standards: This product meets the following standards.
U.S. Federal Communications Commission
RADIATED ENERGY Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with this instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Note: Modifications or changes not expressly approved of by the manufacturer or the FCC, can void your right to operate this equipment.
Industry Canada
This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations. Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.
!
RFI Emission EN55022 Class A
WARNING: In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
Immunity EN50082-1, UL 1950
Electrical Safety EN60950
Laser EN60825
Important: Appendix A contains translated safety statements for installing this equipment. When you see
!
the
, go to Appendix A for the translated safety statement in your language.
Wichtig: Anhang A enthält übersetzte Sicherheitshinweise für die Installation dieses Geräts. Wenn Sie sehen, schlagen Sie in Anhang A den übersetzten Sicherheitshinweis in Ihrer Sprache nach.
Vigtigt: Tillæg A indeholder oversatte sikkerhedsadvarsler, der vedrører installation af dette udstyr. Når De ser symbolet !, skal De slå op i tillæg A og finde de oversatte sikkerhedsadvarsler i Deres eget sprog.
Belangrijk: Appendix A bevat vertaalde veiligheidsopmerkingen voor het installeren van deze apparatuur. Wanneer u de
Important: L'annexe A contient les instructions de sécurité relatives à l'installation de cet équipement. Lorsque vous voyez le symbole instructions dans votre langue.
Tärkeää: Liite A sisältää tämän laitteen asentamiseen liittyvät käännetyt turvaohjeet. Kun näet symbolin, katso käännettyä turvaohjetta liitteestä A.
Importante: l’Appendice A contiene avvisi di sicurezza tradotti per l’installazione di questa apparecchiatura. Il simbolo
Viktig: Tillegg A inneholder oversatt sikkerhetsinformasjon for installering av dette utstyret. Når du ser
!
Importante: O Anexo A contém advertências de segurança traduzidas para instalar este equipamento. Quando vir o símbolo
Importante: El Apéndice A contiene mensajes de seguridad traducidos para la instalación de este equipo. Cuando vea el símbolo
Obs! Bilaga A innehåller översatta säkerhetsmeddelanden avseende installationen av denna utrustning. När du ser
!
ziet, raadpleeg Appendix A voor vertaalde veiligheidsinstructies in uw taal.
!
!
, indica di consultare l’Appendice A per l’avviso di sicurezza nella propria lingua.
, åpner du til Tillegg A for å finne den oversatte sikkerhetsinformasjonen på ønsket språk.
!
, leia a advertência de segurança traduzida no seu idioma no Anexo A.
!
, vaya al Apéndice A para ver el mensaje de seguridad traducido a su idioma.
!
, skall du gå till Bilaga A för att läsa det översatta säkerhetsmeddelandet på ditt språk.
!
2
!
!
, reportez-vous à l'annexe A pour consulter la traduction de ces
1
!
3
4
5
!
!
-
iii
Page 4
Page 5

Table of Contents

Electrical Safety and Emission Statement .............................................iii
Welcome to Allied Telesyn ......................................................................... vii
Where to Find Web-based Guides .................................................................. vii
Document Conventions ................................................................................... vii
Contacting Allied Telesyn.............................................................................. viii
Online Support ........................................................................................ viii
Telephone and Fax Support .................................................................... viii
E-mail Support ........................................................................................ viii
Returning Products .......................................................................................... ix
FTP Server........................................................................................................ ix
For Sales or Corporate Information ................................................................. x
Tell Us What You Think ................................................................................... x
Overview .......................................................................................................... 1
Gigabit Ethernet Technology and FDDI Technology ...................................... 2
Features and Components ................................................................................ 3
Fiber Optic Port 1 (P1) ............................................................................... 4
Fiber Optic Port 2 (P2) ............................................................................... 4
AC Power Socket ........................................................................................ 4
Port and System LEDs ............................................................................... 5
Installing the AT-EX1001SC/GM1 Multimode Extender................................ 6
Planning the Installation ........................................................................... 6
Selecting a Site ........................................................................................... 7
Verifying Package Contents ...................................................................... 7
Reviewing Safety Guidelines ..................................................................... 7
Installing the Unit ...................................................................................... 9
Troubleshooting............................................................................................... 10
Technical Specifications.................................................................................. 11
Warranty Registration .................................................................................... 11
Appendix A
Translated Safety and Emission Information ....................................... 13
Appendix B
Technical Support Fax Order ................................................................... 25
Incident Summary........................................................................................... 25
Appendix C
AT-EX1001SC/GM1 Installation Guide Feedback ................................. 27
v
Page 6
Page 7

Welcome to Allied Telesyn

This guide contains instructions on how to install the AT-EX1001SC/GM1 Gigabit Ethernet Multimode Extender.

Where to Find Web-based Guides

The Allied Telesyn web site at www.alliedtelesyn.com provides you with an easy way to access the most recent documentation and technical information for all of our products. All web-based documents relating to this product and other Allied Telesyn products can be downloaded from the web site in PDF format.

Document Conventions

This guide uses several conventions that you should become familiar with first before you begin to install the product.
Note
A note provides additional information.
Caution
A caution indicates that performing or omitting a specific action may result in equipment damage or loss of data.
Warning
A warning indicates that performing or omitting a specific action may result in bodily injury.
vii
Page 8

Contacting Allied Telesyn

There are several ways that you can contact Allied Telesyn technical support: online, telephone, fax, or e-mail.

Online Support

You can request technical support online by filling out the Online Technical Support Form at www.alliedtelesyn.com/forms/support.htm.

Telephone and Fax Support

Americas
United States, Canada, Mexico, Central America, South America Tel: 1 (800) 428-4835, option 4 Fax: 1 (503) 639-317
Asia
Singapore, Taiwan, Thailand, Malaysia, Indonesia, Korea, Philippines, China, India, Hong Kong Tel: (+65) 381-5612 Fax: (+65) 383-3830
Australia
Tel: 1 (800) 000-880 Fax: (+61) 2-9438-4966
France
France, Belgium, Luxembourg, The Netherlands, Middle East, Africa Tel: (+33) 0-1-60-92-15-25 Fax: (+33) 0-1-69-28-37-49
6

E-mail Support

United States and Canada
TS1@alliedtelesyn.com
Germany
Germany, Switzerland, Austria, Eastern Europe Tel: (+49) 0130/83-56-66 Fax: (+49) 30-435-900-115
Italy
Italy, Spain, Portugal, Greece, Turkey, Israel Tel: (+39) 02-416047 Fax: (+39) 02-419282
Japan
Tel: (+81) 3-3443-5640 Fax: (+81) 3-3443-2443
United Kingdom
United Kingdom, Denmark, Norway, Sweden, Finland Tel: (+0044) 1235-442500 Fax: (+44) 1-235-442680
Latin America, Mexico, Puerto Rico, Caribbean, and Virgin Islands
latin_america@alliedtelesyn.com
United Kingdom, Sweden, Norway, Denmark, and Finland
support_europe@alliedtelesyn.com
viii
Page 9
AT-EX1001SC/GM1 Installation Guide

Returning Products

Products for return or repair must first be assigned a Return Materials Authorization (RMA) number. A product sent to Allied Telesyn without a RMA number will be returned to the sender at the sender’s expense.
To obtain an RMA number, contact Allied Telesyn’s Technical Support at one of the following locations:
North America
2205 Ringwood Ave San Jose, CA 95131 Tel: 1-800-428-4835, option 4 Fax: 1-503-639-3716
Latin America, the Caribbean, Virgin Islands
Tel: international code + 425-481-3852 Fax: international code + 425-483-9458
European Customer Support Centre
10/11 Bridgemead Close Westmead Industrial Estate Swindon, Wiltshire SN5 7YT England Tel: +44-1793-501401 Fax: +44-1793-431099
Mexico and Puerto Rico
Tel: 1-800-424-5012, ext 3852 or
1-800-424-4284, ext 3852 Mexico only: 95-800-424-5012, ext 3852 Fax: international code + 425-489-9191

FTP Server

If you need a device driver for an Allied Telesyn device and you know the name of the driver, you can download the software by connecting directly to our FTP server at ftp://gateway.centre.com.
At login, enter ‘anonymous’. Enter your e-mail address for the password as requested by the server at login.
ix
Page 10

For Sales or Corporate Information

Allied Telesyn International, Corp.
19800 North Creek Parkway, Suite 200 Bothell, WA 98011 Tel: 1 (425) 487-8880 Fax: 1 (425) 489-9191
Allied Telesyn International, Corp.
960 Stewart Drive, Suite B Sunnyvale, CA 94085 Tel: 1 (800) 424-4284 (USA and Canada) Fax: 1 (408) 736-0100

Tell Us What You Think

If you have any comments or suggestions on how we might improve this or other Allied Telesyn documents, please fill out the “AT-EX1001SC/GM1 Installation Guide Feedback” on page 27 and return the form to us at the address or fax number provided. You can also provide feedback online by filling out the send Us Feedback Form at www.alliedtelesyn.com/forms/ feedback.htm.
x
Page 11

Overview

The AT-EX1001SC/GM1 Gigabit Ethernet Multimode Extender (Figure 1) allows you to extend the maximum distance of standard multimode fiber cable for 1000Base-SX Gigabit Ethernet beyond the distance limitations imposed by the current IEEE 802.3z standard. With this unit, you can extend your network up to 2 kilometers (1.24 miles) over 50/125 or 62.5/125 micron multimode fiber optic cabling.
C
O
P
2
P
C
O
P
1
P
C
A
B
P
R
T
R
W
P
D
S
D
S
R
D
S
EX1001SC/GM1
Figure 1 AT-EX1001SC/GM1 Gigabit Ethernet Multimode Extender
1
Page 12

Gigabit Ethernet Technology and FDDI Technology

Because of its high-speed and fault-tolerant features, fiber distributed data interface (FDDI) has frequently been used to build backbone networks. However, the growth of new applications that require extremely high rates of throughput, greater than that allowed by FDDI, have emerged and have exceeded the capabilities of FDDI to handle the load. Examples of high demand network applications include streaming audio and video content.
The solution for many networks is to migrate from FDDI to Gigabit Ethernet, which offers the same resiliency as FDDI but with greater bandwidth capability. However, one of the principal disadvantages to migrating from FDDI to Gigabit Ethernet has been the cost of replacing the legacy multimode fiber optic cabling of the FDDI topology to one designed for Gigabit Ethernet, typically single-mode fiber. Currently, Gigabit Ethernet transmission on multimode fiber is limited to a maximum of 550 meters (1500 feet) on 50/125 micron fiber and 275 meters (754 feet) on 62.5/125 micron. In network configurations requiring greater distances, a network administrator has been confronted with the choice of either retaining FDDI and its lower bandwidth or replacing the existing multimode fiber cable with single-mode cable, typically at great cost.
The AT-EX1001SC/GM1 Gigabit Ethernet Multimode Extender greatly simplifies the migration by allowing the network administrator to install Gigabit Ethernet while maintaining the existing multimode fiber cable. With this unit, which must be used in pairs, the network administrator can extend the distance of Gigabit Ethernet transmission over multimode fiber cable from the current limitation of 550 meters (1500 feet) to 2 kilometers (1.24 miles). In many situations, this eliminates the need of replacing the existing multimode fiber cable by enabling the network administrator to use the legacy cable system.
Figure 2 illustrates a network that incorporates two AT-EX1001SC/GM1 Gigabit Multimode Extenders. The units interconnect an AT-8224XL Fast Ethernet Switch with an AT-A15/SX Expansion Module and an AT-9006 Gigabit Ethernet Switch.
2
Page 13
AT-EX1001SC/GM1 Installation Guide
STATUS
RESET
FAULT
R
PS PWR
1000BASE-SX
A
B
RS-232
TERMINAL PORT
PORT ACTIVITY
L
/
A
D
/C
L/A
D/C
L
/
A
D/C
L/A
D
/
C
L
/A
D
/C
L/A
D/C
LINK
ACTIVITY
FULL
D
UP
L/A
D/
C
HALF DUP COL
1
RX
TX
4
RX
TX
2
R
X T
X
5
RX TX
3
RX T
X
6
R
X T
X
1
000
BA
SE-
S
X
GI
GA
BIT
E
THERNET SWITCH
R
2 km
Multimode fiber cable
R
AT-EX1001 Gigabit
Multimode Extenders
275 m / 550 m
AT-8224XL Switch with
STATUS
RS-232
ITY
TERMINAL PORT
T ACTIV
POR
/ 100BASE-TX
10BASE-T
TX 100BASE­/ T
10BASE-
T SWITCH ST ETHERNE FA
AT-9006 Switch
275 m / 550 m
AT-A15 Expansion Module
Figure 2 Example Topology

Features and Components

The AT-EX1001SC/GM1 Gigabit Ethernet Multimode Extender has the following features:
One 1000Base-X fiber optic port (Port 1) with a maximum operating
distance of 2 kilometers (1.24 miles) using 50/125 or 62.5/125 micron multimode fiber
One 1000Base-SX fiber optic port (Port 2) with a maximum range of
550 meters (1500 feet) using 50/125 micron multimode fiber or 275 meters (754 feet) using 62.5/125 micron multimode fiber
System and port status LEDs Full-duplex operation One AC power supply socket.
3
Page 14
Figure 3 illustrates the front panel of the unit.
EX1001SC/GM1
1000Base-X Fiber Optic
Port 2 (P2)Port 1 (P1) 1000Base-SX Fiber Optic
Figure 3 AT-EX1001SC/GM1 Front Panel

Fiber Optic Port 1 (P1)

Port 1 is a 1000Base-X port that operates with either 50/125 or 62.5/125 micron multimode fiber and has a maximum operating distance of 2 kilometers (1.24 miles). This port operates in full-duplex mode at 1000 Mbps.
Note
Port 1 must be connected to Port 1 on another AT-EX1001SC/GM1 Multimode Extender. Do not connect Port 1 to any other type of network device.

Fiber Optic Port 2 (P2)

Port 2 is a 1000Base-SX port that operates with either 50/125 micron multimode fiber for a maximum operating distance of 550 meters (1500 feet) or
62.5/125 micron multimode fiber for a maximum distance of 275 meters (754 feet). This port can be connected to a switch, server, or other network device that can operate at 1000 Mbps in full-duplex mode.

AC Power Socket

The single AC power supply socket in the front panel has autoranging AC voltage inputs, ranging from 100 to 240 VAC, 50/60 Hz
4
Page 15
AT-EX1001SC/GM1 Installation Guide

Port and System LEDs

The front panel has several LEDs that display the status of the ports and the unit. Table 1 describes the functions of the LEDs.
Table 1 AT-EX1001SC/GM1 LED Indicators
LED Description State Indicates
System LEDs
PWR/ NMS
Power Green Extender is powered up and ready for
use.
LP/BACK Loop Back N/A Not implemented.
Port LEDs
SD Signal Detect Green Signal is present on this port.
PLL LOCK
Phase Lock Loop Lock
Green Phase Lock Loop is locked on this
port.
Note
A valid port link is indicated only when both the SD and the PLL LOCK LEDs are ON.
5
Page 16

Installing the AT-EX1001SC/GM1 Multimode Extender

The AT-EX1001SC/GM1 Multimode Extender is installed and used in pairs. The units do not support the use of any media converters in the configuration. The pair of extenders is connected directly to the host and to each other. The units are easy to install and do not require any software configuration or software management.

Planning the Installation

When installing an AT-EX1001SC/GM1 Multimode Extender, do not exceed the maximum cable distances intended for its media type. Refer to Table 2 for a description of the standards (connectors), media, and maximum distances for each port.
Table 2 Media Types and Distances
Port
Port 1 (P1)
Connector Type
1
SC 50/125 micron or 62.5/
Media Type
MHz/km Rating
Maximum Distance
N/A 2 km (1.24 mi) 125 micron multimode fiber
Port 2 (P2) SC 50/125 micron
multimode fiber
62.5/125 micron multimode fiber
1. Assumes that the opposite end of the fiber cable is connected to P1 on another AT-EX1001SC/GM1 Gigabit Ethernet Mulitmode Extender.
500
400
200
160
550 m (1500 ft)
500 m (1370 ft)
275 m (754 ft)
220 m (604 ft)
Note
Do not use single-mode fiber on either port of the AT-EX1001SC/GM1 Multimode Extender.
6
Page 17
AT-EX1001SC/GM1 Installation Guide

Selecting a Site

Be sure to observe the following requirements when choosing a site for the AT-EX1001SC/GM1 Multimode Extender.
Select a site that is dust-free and moisture-free. Do not block the ventilation openings on the unit. The site should
allow for proper heat dissipation from and adequate ventilation around the unit.
Be sure that the site will allow you to easily access the fiber optic
cables and the power cable.
Use dedicated power circuits or power conditioners to supply reliable
power to the unit.

Verifying Package Contents

Make sure that the following items are included in your package, If any of the following items are missing or damaged, contact your Allied Telesyn sales representative.
One AT-EX1001SC/GM1 Gigabit Ethernet Multimode Extender Power cord (Americas, EC, Australia, and UK only) This installation guide Warranty card

Reviewing Safety Guidelines

Please review the following safety guidelines before you begin to install the unit. Refer to Appendix A for translated safety statements in your language.
Laser
Class 1 laser product. ! 6
Laser
Do not stare into the laser beam. ! 7
Warning
Electric Shock Hazard: To prevent electric shock, do not remove the
cover. There are no user-serviceable parts inside. The unit contains hazardous voltages and should only be opened by a trained and qualified technician. ! 8
7
Page 18
Warning Lightning Danger: Do not work on this equipment or cables during
periods of lightening activity. ! 9
Warning Power cord is used as a disconnection device: To de-energize
equipment, disconnect the power cord. ! 10
Warning Electrical-Type Class 1 Equipment: This equipment must be
earthed. The power plug must be connected to a properly wired earth ground socket outlet. An improperly wired socket outlet could place hazardous voltages on accessible metal parts. ! 11
Caution Pluggable Equipment: The socket outlet should be installed near the
equipment and should be easily accessible. ! 12
Caution Air vents: The air vents must not be blocked on the unit and must have
free access to the room ambient air for cooling. ! 13
Caution Operating Temperature: This product is designed for a maximum
ambient temperature of 50°C. ! 14
Caution All Countries: Install this product in accordance with local and
National Electric Codes. ! 15
8
Page 19
AT-EX1001SC/GM1 Installation Guide

Installing the Unit

To install the AT-EX1001SC/GM1 Multimode Extender on a desktop, perform the following steps:
1. Remove all components from the shipping package and store the packaging material in a safe location.
2. Locate a level, secure surface for the unit.
Warning
The power cord is used as a disconnection device. To de-energize equipment, disconnect the power cord. ! 10
3. Apply AC power to the AT-EX1001SC/GM1 Multimode Extender by plugging the power cord into the AC power connector on the front of the unit and plugging the other end into a wall outlet. Check that the Power LED illuminates.
Caution
Do not remove the dust covers from the fiber optic ports on the unit until you are ready to connect the cables. Dust contamination can adversely impact the operation of the ports.
4. Remove the dust cover from Port 1 (P1) on the AT-EX1001SC/GM1 Multimode Extender.
5. Connect the appropriate fiber optic cable to Port 1 (P1) on the Gigabit Ethernet multimode extender. The cable should connect the TX port of one AT-EX1001SC/GM1 Multimode Extender to the RX port of the other multimode extender.
6. Remove the dust cover from Port 2 (P2) on the AT-EX1001SC/GM1 Multimode Extender.
7. Connect one end of the fiber optic cable to Port 2 (P2) and the other end to the host. The cable should connect the TX port of the extender to the RX port of the host device. Similarly, the RX port of the extender should connect to the TX port of the host device.
8. Check that the LEDs on the unit. Refer to Table 1 for a description of the functions of each LED.
9
Page 20

Troubleshooting

This sections contains troubleshooting recommendations should you encounter any problems with the unit.
If the Power LED does not light up after connecting the AC power cord, do the following:
Make sure that the power cord is securely connected to the front of the
AT-EX1001SC/GM1 Multimode Extender and that the other end is securely connected to a power outlet.
Try using another power cord to see if power is supplied to the unit. Check that the power outlet has power by connecting another device
to it.
If the PLL Lock and SC LEDs of Port 1 do not illuminate after connecting both AT-EX1001SC/GM1 Multimode Extenders, do the following:
Make sure that the power cords of both units are securely connected
to their power outlets and that power is being fed into the units.
Check the connections between units. The cable attached to the TX
port of one unit should connect to the RX port of the other unit.
Make sure that the entire network is functioning properly in case the
problem might lie beyond the unit.
If after connecting one of the units to the host device the PLL Lock and SC LEDs of Port 2 fail to light up, do the following:
Make sure that both the host device and the AT-EX1001SC/GM1
Multimode Extender are powered up and functioning properly.
Check the connections between the AT-EX1001SC/GM1 Multimode
Extender and the host device. The cable attached to the TX port on AT-EX1001SC/GM1 Multimode Extender should connect to the RX port of the host. Likewise, the RX port of the unit should connect to the TX port of the host device.
Check that the entire network is functioning properly in case the
problem might lie beyond the AT-EX1001SC/GM1 Multimode Extender.
10
Page 21
AT-EX1001SC/GM1 Installation Guide

Technical Specifications

Table 3 lists the technical specifications of the unit.
Table 3 Technical Specifications
Specifications
Dimensions (W x D x H) 16 cm x 20 cm x 3.8 cm (6.39 in x 7.9 in x 1.5 in)
Weight 1.29 kg (2.85 lbs)
Maximum Operating Temperature
Maximum Storage Temperature
Operating Altitude Up to 10,000 feet (3,048 meters)
Humidity 5% to 85% (non-condensing)
EMI/RFI FCC Class A, EN55022 Class A
Safety EN60950, UL 1950
Immunity EN50082-1
Power:
Input Supply Voltage Power Consumption
-5° C to 45° C (23° F to 113° F)
-10° C to 60° C (14° F to 140° F)
100-240 VAC 50/60 Hz 12 watts

Warranty Registration

The AT-EX1001SC/GM1 Gigabit Ethernet Multimode Extender comes with a Limited Lifetime Warranty. The power supply has a five (5) year warranty.
When you have finished installing the unit, you should register your product by completing the enclosed warranty card and sending it in, or by visiting our web site at www.alliedtelesyn.com/forms/warranty.htm and completing the on-line registration.
11
Page 22
Page 23

Appendix A

Translated Safety and Emission Information

Important: This appendix contains multiple-language translations for the safety statements in this guide.
Wichtig: Dieser Anhang enthält Übersetzungen der in diesem Handbuch enthaltenen Sicherheitshinweise in mehreren Sprachen.
Vigtigt: Dette tillæg indeholder oversættelser i flere sprog af sikkerhedsadvarslerne i denne håndbog.
Belangrijk: Deze appendix bevat vertalingen in meerdere talen van de veiligheidsopmerkingen in deze gids.
Important: Cette annexe contient la traduction en plusieurs langues des instructions de sécurité figurant dans ce guide.
Tärkeää: Tämä liite sisältää tässä oppaassa esiintyvät turvaohjeet usealla kielellä.
Importante: questa appendice contiene traduzioni in più lingue degli avvisi di sicurezza di questa guida.
Viktig: Dette tillegget inneholder oversettelser til flere språk av sikkerhetsinformasjonen i denne veiledningen.
Importante: Este anexo contém traduções em vários idiomas das advertências de segurança neste guia.
Importante: Este apéndice contiene traducciones en múltiples idiomas de los mensajes de seguridad incluidos en esta guía.
Obs! Denna bilaga innehåller flerspråkiga översättningar av säkerhetsmeddelandena i denna handledning.
13
Page 24
Standards
RADIATED ENERGY
Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with this instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Note: Modifications or changes not expressly approved of by the manufacturer or the FCC, can void your right to operate this equipment.
This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.
Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.
: This product meets the following standards.
U.S. Federal Communications Commission
Industry Canada
!
1
!
2 WARNING
!
3
!
4
!
5
!
6 WARNING:
!
7 WARNING
!
8 ELECTRICAL NOTICES
!
9 LIGHTNING DANGER
!
10 CAUTION:
!
11
RFI Emission EN55022 Class A
which case the user may be required to take adequate measures.
Immunity EN50082-1
Electrical Safety EN60950, UL 1950
Laser EN60825
SAFETY
WARNING:
To prevent ELECTRIC shock, do not remove the cover. No user-serviceable parts inside. This unit contains HAZARDOUS VOLTAGES and should only be opened by a trained and qualified technician. To avoid the possibility of ELECTRIC SHOCK, disconnect electric power to the product before connecting or disconnecting the LAN cables.
DANGER:
LIGHTNING ACTIVITY.
ENERGIZE EQUIPMENT, disconnect the power cord.
ELECTRICAL - TYPE CLASS 1 EQUIPMENT THIS EQUIPMENT MUST BE EARTHED. Power plug must be connected to a properly wired earth ground socket outlet. An improperly wired socket outlet could place hazardous voltages on accessible metal parts.
: In a domestic environment this product may cause radio interference in
Class 1 Laser product.
: Do not stare into the laser beam.
ELECTRIC SHOCK HAZAR
DO NOT WORK on equipment or CABLES during periods of
POWER CORD IS USED AS A DISCONNECTION DEVICE. TO DE-
D
14
Page 25
AT-EX1001SC/GM1 Installation Guide
!
12
!
13 CAUTION:
!
14 OPERATING TEMPERATURE:
!
15 ALL COUNTRIES:
!
1
!
2 WARNUNG
!
3
!
4
!
5
!
6 WARNUNG:
!
7 WARNUNG:
!
8ACHTUNG:
!
9 GEFAHR DURCH BLITZSCHLAG
!
10 VORSICHT:
!
11
!
12
!
13 VORSICHT
!
14 BETRIEBSTEMPERATUR:
!
15 ALLE LÄNDER:
PLUGGABLE EQUIPMENT, the socket outlet shall be installed near the equipment and shall be easily accessible.
ambient air for cooling.
temperature of 40° degrees C.
Codes.
Normen
Hochfrequenzstörung EN55022 Klasse A
hervorrufen. In diesem Fall müßte der Anwender angemessene Gegenmaßnahmen ergreifen.
Störsicherheit EN50082-1
Elektrische Sicherheit EN60950, UL 1950
Laser EN60825
SICHERHEIT
Das Gehäuse nicht öffnen. Das Gerät enthält keine vom Benutzer wartbaren Teile. Das Gerät steht unter Hochspannung und darf nur von qualifiziertem technischem Personal geöffnet werden. Vor Anschluß der LAN-Kabel, Gerät vom Netz trennen.
GEFAHR:
ausführen.
STROMVERSORGUNG. ZUR TRENNUNG VOM NETZ, KABEL AUS DE STECKDOSE ZIEHEN.
GERÄTE DER KLASSE 1 DIESE GERÄTE MÜSSEN GEERDET SEIN. Der Netzstecker darf nur mit einer vorschriftsmäßig geerdeten Steckdose verbunden werden. Ein unvorschriftsmäßiger Anschluß kann die Metallteile des Gehauses unter gefährliche elektrische Spannungen setzen.
STECKBARES GERÄT: Die Anschlußbuchse sollte in der Nähe der Einrichtung angebracht werden und leicht zugänglich sein."
Die Entlüftungsöffnungen dürfen nicht versperrt sein und müssen zum Kühlen freien Zugang zur Raumluft haben.
Umgebungstemperatur von nicht mehr als 40° C entworfen.
Vorschriften entsprechen.
Air vents must not be blocked and must have free access to the room
Install product in accordance with local and National Electrical
: Dieses Produkt erfüllt die Anforderungen der nachfolgenden Normen.
: Bei Verwendung zu Hause kann dieses Produkt Funkstörungen
Laserprodukt der Klasse 1.
Nicht direkt in den Strahl blicken.
GEFÄHRLICHE SPANNUNG
Keine Arbeiten am Gerät oder an den Kabeln während eines Gewitters
DAS NETZKABEL DIENT ZUM TRENNEN DE
Installation muß örtlichen und nationalen elektrischen
This product is designed for a maximum ambient
Dieses Produkt wurde für den Betrieb in einer
15
Page 26
Standarder
!
1
!
2ADVARSEL
!
3
!
4
!
5
!
6ADVARSEL
!
7ADVARSEL
!
8 ELEKTRISKE FORHOLDSREGLER
!
9 FARE UNDER UVEJR
!
10 ADVARSEL:
!
11
!
12
!
13 ADVARSEL:
!
14 BETJENINGSTEMPERATUR:
!
15 ALLE LANDE:
Radiofrekvens forstyrrelsesemission EN55022 Klasse A
Bliver det tilfældet, påkræves brugeren muligvis at tage tilstrækkelige foranstaltninger.
Immunitet EN50082-1
Elektrisk sikkerhed EN60950, UL 1950
Laser EN60825
SIKKERHED
ADVARSEL:
For at forebygge ELEKTRISK stød, undlad at åbne apparatet. Der er ingen indre dele, der kan repareres af brugeren. Denne enhed indeholder LIVSFARLIGE STRØMSPÆNDINGER og bør kun åbnes af en uddannet og kvalificeret tekniker. For at undgå risiko for ELEKTRISK STØD, afbrydes den elektriske strøm til produktet, før LAN-kablerne monteres eller afmonteres.
FARE:
LYNAKTIVITET.
STRØMMEN. SKAL STRØMMEN TIL APPARATET AFBRYDES, tages ledningen ud af stikket.
ELEKTRISK - KLASSE 1-UDSTYR DETTE UDSTYR KRÆVER JORDFORBINDELSE. Stikket skal være forbundet med en korrekt installeret jordforbunden stikkontakt. En ukorrekt installeret stikkontakt kan sætte livsfarlig spænding til tilgængelige metaldele.
UDSTYR TIL STIKKONTAKT, stikkontakten bør installeres nær ved udstyret og skal være lettilgængelig.
omgivende luft i rummet for afkøling.
temperatur på maksimum 40 grader C.
national lovgivning for elektriske installationer.
: Dette produkt tilfredsstiller de følgende standarder.
: I et hjemligt miljø kunne dette produkt forårsage radio forstyrrelse.
Laserprodukt av klasse 1
Stirr ikke på strålen.
RISIKO FOR ELEKTRISK STØD
UNDLAD at arbejde på udstyr eller KABLER i perioder med
DEN STRØMFØRENDE LEDNING BRUGES TIL AT AFBRYDE
Ventilationsåbninger må ikke blokeres og skal have fri adgang til den
Installation af produktet skal ske i overensstemmelse med lokal og
.
Dette apparat er konstrueret til en omgivende
16
Page 27
AT-EX1001SC/GM1 Installation Guide
: Dit product voldoet aan de volgende eisen.
Eisen
!
1
!
2WAARSCHUWING
!
3
!
4
!
5
!
6WAARSHUWING
!
7 WAARCHUWING
!
8 WAARSCHUWINGEN MET BETREKKING TOT ELEKTRICITEIT
!
9 GEVAAR VOOR BLIKSEMINSLAG
!
10 WAARSCHUWING:
!
11
!
12
!
13 OPGELET:
!
14 BEDRIJFSTEMPERATUUR:
!
15 ALLE LANDEN:
RFI Emissie EN55022 Klasse A
geval de gebruiker verplicht kan worden om gepaste maatregelen te nemen.
Immuniteit EN50082-1
Electrische Veiligheid EN60950, UL 1950
Laser EN60825
VEILIGHEID
WAARSCHUWING:
Verwijder het deksel niet, teneinde ELEKTRISCHE schokken te voorkomen. Binnenin bevinden zich geen onderdelen die door de gebruiker onderhouden kunnen worden. Dit toestel staat onder GEVAARLIJKE SPANNING en mag alleen worden geopend door een daartoe opgeleide en bevoegde technicus. Om het gevaar op ELEKTRISCHE SCHOKKEN te vermijden, moet u het toestel van de stroombron ontkoppelen alvorens de LAN-kabels te koppelen of ontkoppelen.
GEVAAR:
STROOMKABEL TE ONTKOPPELEN.OM HET TOESTEL STROOMLOOS TE MAKEN: de stroomkabel ontkoppelen.
ELEKTRISCHE TOESTELLEN VAN KLASSE 1 DIT TOESTEL MOET GEAARD WORDEN. De stekker moet aangesloten zijn op een juist geaarde contactdoos. Een onjuist geaarde contactdoos kan de metalen onderdelen waarmee de gebruiker eventueel in aanraking komt onder gevaarlijke spanning stellen.
AAN TE SLUITEN APPARATUUR, de contactdoos wordt in de nabijheid van de apparatuur geïnstalleerd en is gemakkelijk te bereiken."
omgevingslucht ongehinderd toelaten voor afkoeling.
niet meer bedragen dan 40 graden Celsius.
elektrische voorschriften.
NIET aan toestellen of KABELS WERKEN bij BLIKSEM.
: Binnenshuis kan dit product radiostoring veroorzaken, in welk
Klasse-1 laser produkt.
Neit in de straal staren.
GEVAAR VOOR ELEKTRISCHE SCHOKKEN
HET TOESTEL WORDT UITGESCHAKELD DOOR DE
De ventilatiegaten mogen niet worden gesperd en moeten de
De omgevingstemperatuur voor dit produkt mag
het toestel installeren overeenkomstig de lokale en nationale
17
Page 28
ce produit est conforme aux normes de suivantes:
Normes:
!
1
!
2 MISE EN GARDE
!
3
!
4
!
5
!
6ATTENTION
!
7ATTENTION
!
8 INFORMATION SUR LES RISQUES ÉLECTRIQUES
!
9 DANGER DE FOUDRE
!
10 ATTENTION:
!
11
!
12
!
13 ATTENTION:
!
14 TEMPÉRATURE DE FONCTIONNEMENT:
!
15 POUR TOUS PAYS:
Emission d’interférences radioélectriques EN55022 Classe
des interférences radioélectriques. Auquel cas, l’utilisateur devra prendre les mesures adéquates.
Immunité EN50082 - 1
Sécurité électrique EN60950, UL 1950
Laser EN60825
SÉCURITÉ
AVERTISSEMENT
Pour éviter toute ÉLECTROCUTION, ne pas ôter le revêtement protecteur du matériel. Ce matériel ne contient aucun élément réparable par l’utilisateur. Il comprend des TENSIONS DANGEREUSES et ne doit être ouvert que par un technicien dûment qualifié. Pour éviter tout risque d’ÉLECTROCUTION, débrancher le matériel avant de connecter ou de déconnecter les câbles LAN.
DANGER:
POUR COUPER L’ALIMENTATION DU MATÉRIEL, débrancher le cordon.
ÉQUIPEMENT DE CLASSE 1 ÉLECTRIQUE CE MATÉRIEL DOIT ÊTRE MIS A LA TERRE. La prise de courant doit être branchée dans une prise femelle correctement mise à la terre car des tensions dangereuses risqueraient d’atteindre les pièces métalliques accessibles à l’utilisateur.
EQUIPEMENT POUR BRANCHEMENT ELECTRIQUE, la prise de sortie doit être placée près de l’équipement et facilement accessible".
de circuler librement pour le refroidissement.
une température ambiante maximum de ou 40 degrés Celsius.
nationales et locales.
: dans un environnement domestique, ce produit peut provoquer
Producit laser di classe 1.
Ne pas fixer le faisceau des yeux.
: DANGER D’ÉLECTROCUTION
NE PAS MANIER le matériel ou les CÂBLES lors d’activité orageuse.
LE CORDON D’ALIMENTATION SERT DE MISE HORS CIRCUIT.
Ne pas bloquer les fentes d’aération, ceci empêcherait l’air ambiant
Ce matériel est capable de tolérer
Installer le matériel conformément aux normes électriques
A
18
Page 29
AT-EX1001SC/GM1 Installation Guide
Standardit
!
1
!
2VAROITUS
!
3
!
4
!
5
!
6VAROITUS
!
7VARIOTUS
!
8 SÄHKÖÖN LIITTYVIÄ HUOMAUTUKSIA
!
9 SALAMANISKUVAARA
!
10 HUOMAUTUS:
!
11
!
12
!
13 HUOMAUTUS:
!
14 KÄYTTÖLÄMPÖTILA:
!
15 KAIKKI MAAT:
Radioaaltojen häirintä EN55022 Luokka A
tapauksessa laitteen käyttäjän on mahdollisesti ryhdyttävä tarpeellisiin toimenpiteisiin.
Kestävyys EN50082-1
Sähköturvallisuus EN60950, UL 1950
Laser EN60825
TURVALLISUUS
VAROITUS:
Estääksesi SÄHKÖISKUN älä poista kantta. Sisällä ei ole käyttäjän huollettavissa olevia osia. Tämä laite sisältää VAARALLISIA JÄNNITTEITÄ ja sen voi avata vain koulutettu ja pätevä teknikko. Välttääksesi SÄHKÖISKUN mahdollisuuden katkaise sähkövirta tuotteeseen ennen kuin liität tai irrotat paikallisverkon (LAN) kaapelit.
HENGENVAARA:
SALAMOINNIN AIKANA.
VIRTA KATKAISTAAN irrottamalla virtajohto.
SÄHKÖ - TYYPPILUOKAN 1 LAITTEET TÄMÄ LAITE TÄYTYY MAADOITTAA. Pistoke täytyy liittää kunnollisesti maadoitettuun pistorasiaan. Virheellisesti johdotettu pistorasia voi altistaa metalliosat vaarallisille jännitteille.
PISTORASIAAN KYTKETTÄVÄ LAITE; pistorasia on asennettava laitteen lähelle ja siihen on oltava esteetön pääsy."
ympäröivään huoneilmaan, jotta ilmanvaihto tapahtuisi.
maksimilämpötilalle 40°C.
sähköturvallisuusmääräysten mukaisesti.
: Tämä tuote on seuraavien standardien mukainen.
: Kotiolosuhteissa tämä laite voi aiheuttaa radioaaltojen häiröitä, missä
Luokan 1 Lasertuote.
Älä katso säteeseen.
SÄHKÖISKUVAARA
ÄLÄ TYÖSKENTELE laitteiden tai KAAPELEIDEN KANSSA
VIRTAJOHTOA KÄYTETÄÄN VIRRANKATKAISULAITTEENA.
Ilmavaihtoreikiä ei pidä tukkia ja niillä täytyy olla vapaa yhteys
Tämä tuote on suunniteltu ympäröivän ilman
Asenna tuote paikallisten ja kansallisten
19
Page 30
Standard
!
1
!
2 AVVERTENZA:
!
3
!
4
!
5
!
6 AVVERTENZA
!
7 AVERTENZA
!
8 AVVERTENZE ELETTRICHE
!
9 PERICOLO DI FULMINI
!
10 ATTENZIONE:
!
11
!
12
!
13 ATTENZIONE:
!
14 TEMPERATURA DI FUNZIONAMENTO:
!
15 TUTTI I PAESI:
Emissione RFI (interferenza di radiofrequenza) EN55022 Classe
interferenza. In questo caso potrebbe richiedersi all’utente di prendere gli adeguati provvedimenti.
Immunità EN50082-1
Sicurezza elettrica EN60950, UL 1950
Laser EN60825
NORME DI SICUREZZA
ATTENZIONE:
Per evitare SCOSSE ELETTRICHE non asportare il coperchio. Le componenti interne non sono riparabili dall’utente. Questa unità ha TENSIONI PERICOLOSE e va aperta solamente da un tecnico specializzato e qualificato. Per evitare ogni possibilità di SCOSSE ELETTRICHE, interrompere l’alimentazione del dispositivo prima di collegare o staccare i cavi LAN.
PERICOLO:
PRECIPITAZIONI TEMPORALESCHE.
DI DISATTIVAZIONE. PER TOGLIERE LA CORRENTE AL DISPOSITIVO staccare il cavo di alimentazione.
ELETTRICITÀ - DISPOSITIVI DI CLASSE 1 QUESTO DISPOSITIVO DEVE AVERE LA MESSA A TERRA. La spina deve essere inserita in una presa di corrente specificamente dotata di messa a terra. Una presa non cablata in maniera corretta rischia di scaricare una tensione pericolosa su parti metalliche accessibili.
APPARECCHIATURA COLLEGABILE, la presa va installata vicino all’apparecchio per risultare facilmente accessibile".
ricircolo dell’aria ambiente per il raffreddamento.
temperatura ambientale massima di 40 gradi centigradi.
elettriche nazionali.
: Questo prodotto è conforme ai seguenti standard.
in ambiente domestico questo prodotto potrebbe causare radio
Prodotto laser di Classe 1.
Non fissare il raggio con gli occhi.
PERICOLO DI SCOSSE ELETTRICHE
NON LAVORARE sul dispositivo o sui CAVI durante
IL CAVO DI ALIMENTAZIONE È USATO COME DISPOSITIVO
le prese d’aria non vanno ostruite e devono consentire il libero
installare il prodotto in conformità delle vigenti normative
A
Questo prodotto è concepito per una
20
Page 31
AT-EX1001SC/GM1 Installation Guide
Sikkerhetsnormer
!
1
!
2ADVARSEL
!
3
!
4
!
5
!
6ADVARSEL
!
7ADVARSAL
!
8 ELEKTRISITET
!
9 FARE FOR LYNNEDSLAG
!
10 FORSIKTIG:
!
11
!
12
!
13 FORSIKTIG:
!
14 DRIFTSTEMPERATUR:
!
15 ALLE LAND:
RFI stråling EN55022 Klasse A
radioforstyrrelse. Hvis dette skjer, må brukeren ta de nødvendige forholdsregler.
Immunitet EN50082-1
Elektrisk sikkerhet EN60950, UL 1950
Laser EN60825
SIKKERHET
ADVARSEL:
For å unngå ELEKTRISK sjokk, må dekslet ikke tas av. Det finnes ingen deler som brukeren kan reparere på innsiden. Denne enheten inneholder FARLIGE SPENNINGER, og må kun åpnes av en faglig kvalifisert tekniker. For å unngå ELEKTRISK SJOKK må den elektriske strømmen til produktet være avslått før LAN-kablene til- eller frakobles.
FARE:
FOR Å DEAKTIVISERE UTSTYRET, må strømforsyningen kobles fra.
ELEKTRISK - TYPE 1- KLASSE UTSTYR DETTE UTSTYRET MÅ JORDES. Strømkontakten må være tilkoplet en korrekt jordet kontakt. En kontakt som ikke er korrekt jordet kan føre til farlig spenninger i lett t ilgjengelige metalldeler.
UTSTYR FOR STIKKONTAKT. Stikkontakten skal monteres i nærheten av utstyret og skal være lett tilgjengelig."
romtemperatur for avkjøling.
romtemperatur på 40 grader celsius.
elektriske koder.
: Hvis dette produktet benyttes til privat bruk, kan produktet forårsake
Laserprodukt av klasse 1.
Stirr ikke på strålen.
FARE FOR ELEKTRISK SJOKK
ARBEID IKKE på utstyr eller KABLER i TORDENVÆR.
STRØMLEDNINGEN BRUKES TIL Å FRAKOBLE UTSTYRET.
Lufteventilene må ikke blokkeres, og må ha fri tilgang til luft med
Produktet må installeres i samsvar med de lokale og nasjonale
: Dette produktet tilfredsstiller følgende sikkerhetsnormer.
Dette produktet er konstruert for bruk i maksimum
21
Page 32
: Este produto atende aos seguintes padrões.
Padrões
!
1
!
2AVISO
!
3
!
4
!
5
!
6AVISO
!
7AVISO
!
8 AVISOS SOBRE CARACTERÍSTICAS ELÉTRICAS
!
9 PERIGO DE CHOQUE CAUSADO POR RAIO
!
10 CUIDADO:
!
11
!
12
!
13 CUIDADO:
!
14 TEMPERATURA DE FUNCIONAMENTO:
!
15 TODOS OS PAÍSES:
Emissão de interferência de radiofrequência EN55022 Classe
: Num ambiente doméstico este produto pode causar interferência na radiorrecepção e, neste caso, pode ser necessário que o utente tome as medidas adequadas.
Imunidade EN50082-1
Segurança Eléctrica EN60950, UL 1950
Laser EN60825
SEGURANÇA
Produto laser de classe 1.
Não olhe fixamente para o raio.
ATENÇÃO:
Para evitar CHOQUE ELÉTRICO, não retire a tampa. Não contém peças que possam ser consertadas pelo usuário. Este aparelho contém VOLTAGENS PERIGOSAS e só deve ser aberto por um técnico qualificado e treinado. Para evitar a possibilidade de CHOQUE ELÉTRICO, desconecte o aparelho da fonte de energia elétrica antes de conectar e desconectar os cabos da LAN.
PERIGO:
suscetíveis a QUEDAS DE RAIO.
DISPOSITIVO DE DESCONEXÃO. PARA DESELETRIFICAR O EQUIPAMENTO, desconecte o cabo de ALIMENTAÇÃO.
ELÉTRICO - EQUIPAMENTOS DO TIPO CLASSE 1 DEVE SER FEITA LIGAÇÃO DE FIO TERRA PARA ESTE EQUIPAMENTO. O plugue de alimentação deve ser conectado a uma tomada com adequada ligação de fio terra. Tomadas sem adequada ligação de fio terra podem transmitir voltagens perigosas a peças metálicas expostas.
EQUIPAMENTO DE LIGAÇÃO, a tomada eléctrica deve estar instalada perto do equipamento e ser de fácil acesso."
livre ao ar ambiente para arrefecimento adequado do aparelho.
temperatura ambiente máxima de 40 graus centígrados.
para instalações elétricas.
PERIGO DE CHOQUE ELÉTRICO
NÃO TRABALHE no equipamento ou nos CABOS durante períodos
O CABO DE ALIMENTAÇÃO É UTILIZADO COMO UM
As aberturas de ventilação não devem ser bloqueadas e devem ter acesso
Este produto foi projetado para uma
Instale o produto de acordo com as normas nacionais e locais
A
22
Page 33
AT-EX1001SC/GM1 Installation Guide
Estándares:
!
1
!
2 ADVERTENCIA
!
3
!
4
!
5
!
6 ¡ADVERTENCIA!
!
7 ¡ADVERTENCIA!
!
8 AVISOS ELECTRICOS
!
9 PELIGRO DE RAYOS
!
10 ATENCION:
!
11
!
12
!
13 ATENCION:
!
14 TEMPERATURA REQUERIDA PARA LA OPERACIÓN:
!
15 PARA TODOS LOS PAÍSES:
Emisión RFI EN55022 Clase
radiointerferencias, en cuyo caso, puede requerirse del usuario que tome las medidas que sean convenientes al respecto.
Inmunidad EN50082-1
Seguridad eléctrica EN60950, UL 1950
Laser EN60825
SEGURIDAD
ADVERTENCIA:
Para evitar un ELECTROCHOQUE, no quite la tapa. No hay ningún componente en el interior al cual puede prestar servicio el usuario. Esta unidad contiene VOLTAJES PELIGROSOS y sólo deberá abrirla un técnico entrenado y calificado. Para evitar la posibilidad de ELECTROCHOQUE desconecte la corriente eléctrica que llega al producto antes de conectar o desconectar los cables LAN.
PELIGRO:
equipos o en LOS CABLES durante TORMENTAS ELECTRICAS.
DE DESCONEXION. PARA DESACTIVAR EL EQUIPO, desconecte el cable de alimentación.
ELECTRICO - EQUIPO DEL TIPO CLASE 1 ESTE EQUIPO TIENE QUE TENER CONEXION A TIERRA. El cable tiene que conectarse a un enchufe a tierra debidamente instalado. Un enchufe que no está correctamente instalado podría ocasionar tensiones peligrosas en las partes metálicas que están expuestas.
EQUIPO CONECTABLE, el tomacorriente se debe instalar cerca del equipo, en un lugar con acceso fácil".
acceso libre al aire ambiental de la sala para su enfriamiento.
diseñado para una temperatura ambiental máxima de 40 grados C.
Eléctricos locales y nacionales.
Este producto cumple con los siguientes estándares.
: en un entorno doméstico, este producto puede causar
Producto láser Clase 1.
No mirat fijamente el haz.
PELIGRO DE ELECTROCHOQUE
NO REALICE NINGUN TIPO DE TRABAJO O CONEXION en los
EL CABLE DE ALIMENTACION SE USA COMO UN DISPOSITIVO
Las aberturas para ventilación no deberán bloquearse y deberán tener
Monte el producto de acuerdo con los Códigos
A
Este producto está
23
Page 34
Standarder:
!
1
!
2VARNING
!
3
!
4
!
5
!
6 VARNING!
!
7VARNING!
!
8 TILLKÄNNAGIVANDEN BETRÄFFANDE ELEKTRICITETSRISK:
!
9 FARA FÖR BLIXTNEDSLAG
!
10 VARNING:
!
11
!
12
!
13 VARNING:
!
14 DRIFTSTEMPERATUR:
!
15 ALLA LÄNDER:
Radiostörning EN55022 Klass A
tvinga användaren till att vidtaga erforderliga åtgärder.
Immunitet EN50082-1
Elsäkerhet EN60950, UL 1950
Laser EN60825
SÄKERHET
RISK FÖR ELEKTRISK STÖTFör att undvika ELEKTRISK stöt, ta ej av locket. Det finns inga delar inuti som behöver underhållas. Denna apparat är under HÖGSPÄNNING och får endast öppnas av en utbildad kvalificerad tekniker. För att undvika ELEKTRISK STÖT, koppla ifrån produktens strömanslutning innan LAN­kablarna ansluts eller kopplas ur.
FARA:
FRÅN STRÖMMEN, dra ur nätkabeln.
ELEKTRISKT - TYP KLASS 1 UTRUSTNING DENNA UTRUSTNING MÅSTE VARA JORDAD. Nätkabeln måste vara ansluten till ett ordentligt jordat uttag. Ett felaktigt uttag kan göra att närliggande metalldelar utsätts för högspänning. Apparaten skall anslutas till jordat uttag, när den ansluts till ett nätverk.
UTRUSTNING MED PLUGG. Uttaget skall installeras i utrustningens närhet och vara lättåtkomligt".
rumsluft för avsvalning.
överstigande 40 grader Celsius.
bestämmelser för elektrisk utrustning.
Denna produkt uppfyller följande standarder.
: Denna produkt kan ge upphov till radiostörningar i hemmet, vilket kan
Laserprodukt av klass 1.
Laserstrålning när enheten är öppen.
ARBETA EJ på utrustningen eller kablarna vid ÅSKVÄDER.
NÄTKABELN ANVÄNDS SOM STRÖMBRYTARE FÖR ATT KOPPLA
Luftventilerna får ej blockeras och måste ha fri tillgång till omgivande
Denna produkt är konstruerad för rumstemperatur ej
Installera produkten i enlighet med lokala och statliga
24
Page 35

Appendix B

Technical Support Fax Order

Name _________________________________________________________________ Company______________________________________________________________ Address _______________________________________________________________ City______________________ State/Province_______________________________ Zip/Postal Code ________________ Country_______________________________ Phone______________________________ Fax _______________________________

Incident Summary

Model number of Allied Telesyn product I am using _______________________ Firmware release number of Allied Telesyn product _______________________ Other network software products I am using (e.g., network managers)
______________________________________________________________________ ______________________________________________________________________ ______________________________________________________________________
Brief summary of problem ______________________________________________
______________________________________________________________________ ______________________________________________________________________
Conditions (List the steps that led up to the problem.)______________________
______________________________________________________________________ ______________________________________________________________________ ______________________________________________________________________ ______________________________________________________________________
______________________________________________________________________ Detailed description (Please use separate sheet). Please also fax printouts of relevant files such as batch files and configuration
files. When completed, fax this sheet to the appropriate Allied Telesyn office. Fax numbers can be found on page viii.
25
Page 36
Page 37

Appendix C

AT-EX1001SC/GM1 Installation Guide Feedback

Please tell us what additional information you would like to see discussed in this guide. If there are topics you would like information on that were not covered in this guide, please photocopy this page, answer the questions and fax or mail this form back to Allied Telesyn. The mailing address and fax number are at the bottom of the page. Your comments are valuable when we plan future revisions of this guide.
I found the following the most valuable __________________________________
______________________________________________________________________
______________________________________________________________________
______________________________________________________________________
______________________________________________________________________ I would like the following more developed ________________________________
______________________________________________________________________
______________________________________________________________________
______________________________________________________________________
______________________________________________________________________ I would find this guide more useful if ____________________________________
______________________________________________________________________
______________________________________________________________________
______________________________________________________________________
Please fax or mail your feedback. Fax to 1-408-736-0100. Or mail to:
Allied Telesyn International, Corp.
c/o Technical Communications 960 Stewart Drive, Suite B Sunnyvale, CA 94085 USA
PN 613-10857-00 Rev A
27
Page 38
Loading...