Allied Telesis AT-DC2552XS User Manual

Page 1
Switches
product information
AT-DC2552XS
HIGH PERFORMANCE, LOW LATENCY
TOP-OF-RACK DATA CENTER SWITCH
Designed for virtualized data center and cloud environments, the
Allied Telesis AT-DC2552XS switch provides high density 10GbE
and 40GbE connectivity, making it ideal for today’s big data, cloud and optimized workloads.
This data center switch has been
designed with green functionality in mind, resulting in lower power consumption per port, which results in a lower Total Cost of Ownership.
The AT-DC2552XS is a 48 x 10GbE
(SFP+) port high-bandwidth and high density switch designed for data center applications. It also provides four QSFP+ 40GbE slots for “fat-pipe” high bandwidth uplinks. This switch delivers
1280Gbps of switching fabric with ultra
low sub-μsec latency. Airow has been optimized for front-to-back cooling for data center environments. The unit can also accommodate a 1+1 resilient power supply, all of this in a very compact 1RU unit chassis.
A smarter data center with improved
economics of IT can be achieved by connecting servers and storage facilities with a high-speed and low latency network fabric that is smarter, faster, greener, open and easy to manage.
Advanced Energy Efciency
The AT-DC2552XS provides more
than just speeds and feeds. Energy efcient architecture and front-to-back air-ow cooling of the AT-DC2552XS are critical factors in optimizing data
center economics—as companies need
to balance performance with power
consumption to meet energy budgets.
High-bandwidth
As bandwidth-intensive applications
such as Web 2.0, virtualization, High­Performance Computing (HPC) and Network Attached Storage (NAS) continue to proliferate within enterprise data centers, 10 Gigabit Ethernet
(10GbE) provides a cost effective
way to increase throughput and seamlessly deliver customer service level agreements.
Future Proong
10GbE empowers companies to
expand application capabilities, reduce time to solve complex nancial and scientic applications, and quickly respond to changing customer needs and market conditions.
In combination with the AT-VNC10S Network Interface Cards for servers, it helps clients to reduce the of I/O adapters, reducing costs and complexity.
High Availability
The AT-DC2552XS has two slots for
hot-swappable PSU’s (Power Supply Unit) and FANs. Also SFP+ and QSFP modules can be easily removed and replaced with no interruption to the network. These hot-swappable modules guarantee the continued delivery of essential services.
Cut-through
Cut-through switching sends the packet to the destination as soon as the rst packet is ready. The delay is minimal and the packet reaches its destination in the shortest possible time. With cut-through mode, the AT-DC2552XS forwards packets with a latency of 505 nanoseconds with 40Gb / 800 nanoseconds with 10Gb and is ideal use for inter-server communication.
Air Flow
Cooling air ow has become a major design concern in modern data centers.
The AT-DC2552XS utilizes front (PSU/
and FAN side) to back (ports side) airow which is suitable for rack mounting in data centers.
alliedtelesis.com
Page 2
AT-DC2552XS | High Performance, Low Latency Top-of-Rack Data Center Switch
Servers-Storage
DC2552XS
SERVER RACK
DC2552XS
DC2552XS
AoE communication
SBx8100
LAYER 3 FEATURES
x900-24 x900-24
DC2552XS
DC2552XS
DC2552XS
STORAGE RACK
DC2552XS
Specifications
Port
» Switch port
SFP+ slot x 48 ports QSFP+ slot x 4
» Console port
RS-232 (USB connector) x 1
» Management port
10/100/1000T (RJ-45 connector) x 1 Auto negotition, MDI-MDI-X
System
» Forwarding rate 952.38Mpps
» Switching capacity 1280Gbps
» 128K MAC addresses
» Cut-through mode
Latency 40GB:505ns (64byte)
10GB:800ns (64byte)
» 2GB RAM
» 128MB flash memory
» 1.3Ghz CPU
» 9MB packet buffer
» Maximum jumbo frames 12K bytes
» 32 link aggregation group / 8 members per group
Wire-speed switching on all Ethernet ports
» 14,880,000pps for 10Gbps Ethernet
» 59,523,800pps for 40Gbps Ethernet
Environmental Specifications
» Operating temperature 0ºC to 40ºC
» Storage temperature -20ºC to 60ºC
» Operating humidity 10% to 80%
(non-condensing
» Storage humidity 5% to 90%
(non-condensing)
Port Configuration
» Auto-negotiation, duplex, MDI/MDI-X, IEEE
802.3x flow control
» Packet storm protection
» Port mirroring
» Broadcast storm control
» Ethernet statistics
» Egress-rate-limit
» LinkTrap
10 Gigabit link 40 Gigabit link
Ethernet Specifications
» IEEE 802.3 10T*
» IEEE 802.3u 100TX*
» IEEE 802.3ab 1000T*
» IEEE 802.3ae 10GBASE-SR, 10GBASE-LR
» IEEE 802.3ba 10GBASE-SR4/XLPPI,40GBASE-CR4
» IEEE 802.1Q Virtual LANs
» IEEE 802.3ad (LACP) Link aggregation
» IEEE 802.3z Gigabit Ethernet
*Only for management port use
Quality of Service (QoS)
» Head-of-line blocking prevention
» Eight egress queues per port
» IEEE 802.1p Class of Service with strict and weighted
round robin scheduling/strict priority scheduling
» Access Control Lists (ACLs)
Spanning-Tree Protocol
» IEEE 802.1D Spanning-Tree Protocol
» IEEE 802.1w Rapid Spanning-Tree
» IEEE 802.1s Multiple Spanning-Tree
2 | AT-DC2552XS
Page 3
AT-DC2552XS | High Performance, Low Latency Top-of-Rack Data Center Switch
Management
» Enviromental monitoring
» DHCP client
» RFC 1350 TFTP client
» NTP
» Zmodem
» HT TP
» TFTP
» RFC 1157 SNMPv1
» RFC 1901 SNMPv2c
» RFC 2571-5 SNMPv3
» RFC 1757 RMON group 1, 3, 9
» Syslog client support
» Event log
» Telnet
» SSHv2
MIB Support
» RFC 1643 Ethernet-like MIB
» Allied Telesis private MIB
» RFC 1757 RMON MIB
» RFC 1493 Bridge MIB
» RFC 1573/2863 Interfaces group MIB
» RFC 1213 MIB-II
» RFC 1215 TRAP MIB
» RFC 3635 Ethernet MIB
VLAN
» 4094 VLANs
» MAC based VLANs – 1K
» Port-based VLANs
» IEEE 802.1Q tag-based VL ANs
Link Aggregation
» Static trunking
» IEEE 802.3ad LACP
» IP option
» Dynamic LACP
» Port trunking
IP Multicasting
» RFC 1112 IGMPv1 snooping
» RFC 2236 IGMPv2 snooping
» RFC 3376 IGMPv3 snooping
» Multicast groups - 255
Security
» Hardware packet filtering
» Layer 2/3/4/ Access Control Lists (ACLs)
» 512 ACL profiles
» 256 rules per ACL profile
» ACLs based on:
- ICMP
- IP
- MAC address
- IP protocol
- TCP
- UDP
» DoS attack protection
- Smurf
- SYN flood
- Teardrop
- Land
- IP option
- Ping attack
Compliance Standards
» IEEE 802.3 – 10T
» IEEE 802.3u – 100TX with auto-negotiation
» IEEE 802.3ab – 1000T Gigabit Ethernet
» IEEE 802.3ae, 10G SFP+ - SFP+ fiber, SFP+ direct
attach
» IEEE 802.3ba - QSFP+
Safety and Electromagnetic Emissions
Certifications
» EMI : FCC class A, CISPR class A, EN55022 class A
» C-TICK, VCCI Class A, CE
» Immunity: EN50024, EN601000-3-3,
EN601000-3-2
» Safety: UL 60950-1 (cUlus), EN60950-1 (T UV)
Physical Specifications
Compliant with European RoHS standards
Package Specifications
» AT-DC2552 XX switch with two PSU bay cover and
two FAN unit bay covers
» Management cable (RS-232 to USB)
» Rubber feet and 19” rack-mountable hardware kit
accessories
» Install Guide and CLI users guide available at
alliedtelesis.com
Physical Specifications
Dimensions 44.1cm x 46cm x 4.4cm
(W x D x H) 17.4in x 18.1in x 1.7in
Weight 8.3kg /18.3lb (chassis only)
11.3kg/24.9lb (chassis with two fans and two PSUs)
Quality and Reliability
» MTBF (Switch + 2 PSU): 180,000
» MTTF (FAN): 2470 hrs (40ºC)
5000 hrs (30ºC) 6970 hrs (25ºC)
Power Characteristics
» Voltage: 100-240V AC (10% auto-ranging)
» Frequency: 50/60 Hz
» Maximum current: 14A @ 100V
» Heat dissipation: 900 BTU/hr
Power Consumption
» 250W (max 280W )
AT-DC2552XS | 3
Page 4
AT-DC2552XS | High Performance, Low Latency Top-of-Rack Data Center Switch
Ordering Information
AT-DC2552XS
48 port SFP+ slot 4 port QSFP slot 1 port console port 1 port management port 2 slots for PWR
2 slots for FAN
SFP+ Modules
AT-SP10SR
10GBASE-SR
AT-SP10LR
10GBASE-LR
AT-PWR06 -xx
Hot-swappable AC power supply
AT-FAN06
Hot-swappable FAN (Two FANs are needed to operate reverse cooling
airflow - port side to PSU/FAN side - is not supported)
QSFP+ and Cable
AT-QSFP1CU
QSFP+copper cable 1m
AT-QSFP3CU
QSFP+ copper cable 3m
AT-QSFPSR
QSFP+ module
Optical Cables
AT-MTP12-1
MTHTP cable for AT-QSFPSR, 1m
AT-MTP12-5
MTHTP cable for AT-QSFPSR, 5m
Where xx = 10 for US power cord 30 for UK power cord 40 for Australian power cord 50 for European power cord
AT-SP10TW1
10GBASE SFP+ direct attach cable (1m)
AT-SP10TW3
10GBASE SFP+ direct attach cable (3m)
AT-SP10TW7
10GBASE SFP+ direct attach cable (7m)
North America Headquarters | 19800 North Creek Parkway | Suite 100 | Bothell | WA 98011 | USA | T: +1 800 424 4284 | F: +1 425 481 3895 Asia-Pacic Headquarters | 11 Tai Seng Link | Singapore | 534182 | T: +65 6383 3832 | F: +65 6383 3830 EMEA & CSA Operations | Antareslaan 18 | 2132 JE Hoofddorp | Netherlands | T: +31 23 5656800 | F: +31 23 5575466
alliedtelesis.com
© 2012 Allied Telesis, Inc. All right s reser ved. Information in this document is subject to change wit hout notice. All company names, logos, and product desi gns that are tradema rks or registe red trademarks are the prope rty of their respective owner s. 617-0 0453 Rev.B
Loading...