Allied Telesis AT-B17 User Manual

AT-B15/SX AT-B15/LX AT-B17 Expansion Modules
For the AT-8324SX Fast Ethernet Switch
Quick Install Guide
Copyright 2000 Allied Telesyn International, Corp. 960 Stewart Drive Suite B, Sunnyvale CA 94086 USA
All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesyn International, Corp.
Ethernet is a registered trademark of Xerox Corporation. All other product names, company names, logos or other designations mentioned herein are trademarks or registered trademarks of their respective owners.
Allied Telesyn International, Corp. reserves the right to make changes in specifications and other information contained in this document without prior written notice. The information provided herein is subject to change without notice. In no event shall Allied Telesyn International, Corp. be liable for any incidental, special, indirect, or consequential damages whatsoever, including but not limited to lost profits, arising out of or related to this manual or the information contained herein, even if Allied Telesyn International Corp. has been advised of, known, or should have known, the possibility of such damages.

Electrical Safety and Emission Statement

Standards
RADIATED ENERGY Note: This equipment has been tested and found to comply with the limits for a Class A
digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with this instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Note: Modifications or changes not expressly approved of by the manufacturer or the FCC, can void your right to operate this equipment.
This Class A digital apparatus meets all requirements of the Canadian Interference­Causing Equipment Regulations.
Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.
RFI Emission EN55022 Class A (CISPR 22)
WARNING
which case the user may be required to take adequate measures. Immunity IEC 1000-4-2 (4 kV CD, 8 kV AD)
Important
equipment. When you see the your language.
Wichtig
Geräts. Wenn Sie Sicherheitshinweis in Ihrer Sprache nach.
Vigtigt
dette udstyr. Når De ser symbolet sikkerhedsadvarsler i Deres eget sprog.
Belangrijk
deze apparatuur. Wanneer u de veiligheidsinstructies in uw taal.
Important
équipement. Lorsque vous voyez le symbole la traduction de ces instructions dans votre langue.
Tärkeää
Kun näe
Importante
questa apparecchiatura. Il simbolo sicurezza nella propria lingua.
: This product meets the following standards.
U.S. Federal Communications Commission
Industry Canada
!
1
EN60555-2 (1995) Class A EN60555-3
: In a domestic environment this product may cause radio interference in
IEC 1000-4-3 (1995) (3 V/m) IEC 1000-4-4 (1995) (1.0 kV - (power line);
0.5 kV - (signal line)) IEC 1000-4-6 (1995) (3 Vrms) EN50082-1 (1992) EN61000-4-2 (1995) EN61000-4-4 (1995)
: Appendix A contains translated safety statements for installing this
: Anhang A enthält übersetzte Sicherheitshinweise für die Installation dieses
: Tillæg A indeholder oversatte sikkerhedsadvarsler, der vedrører installation af
!
: Appendix A bevat vertaalde veiligheidsopmerkingen voor het installeren van
: L'annexe A contient les instructions de sécurité relatives à l'installation de cet
: Liite A sisältää tämän laitteen asentamiseen liittyvät käännetyt turvaohjeet.
!
-symbolin, katso käännettyä turvaohjetta liitteestä A.
: l’Appendice A contiene avvisi di sicurezza tradotti per l’installazione di
!
, go to Appendix A for the translated safety statement in
sehen, schlagen Sie in Anhang A den übersetzten
!
, skal De slå op i tillæg A og finde de oversatte
!
ziet, raadpleeg Appendix A voor vertaalde
!
, reportez-vous à l'annexe A pour consulter
!
, indica di consultare l’Appendice A per l’avviso di
!
2
!
3
iii
Viktig
: Tillegg A inneholder oversatt sikkerhetsinformasjon for installering av dette utstyret. Når du ser sikkerhetsinformasjonen på ønsket språk.
Importante
equipamento. Quando vir o símbolo idioma no Anexo A.
Importante
instalación de este equipo. Cuando vea el símbolo mensaje de seguridad traducido a su idioma.
Obs
! Bilaga A innehåller översatta säkerhetsmeddelanden avseende installationen av denna utrustning. När du ser säkerhetsmeddelandet på ditt språk.
!
, åpner du til Tillegg A for å finne den oversatte
: O Anexo A contém advertências de segurança traduzidas para instalar este
: El Apéndice A contiene mensajes de seguridad traducidos para la
!
, leia a advertência de segurança traduzida no seu
!
, vaya al Apéndice A para ver el
!
, skall du gå till Bilaga A för att läsa det översatta
iv

Table of Contents

Electrical Safety and Emission Statement
Table of Contents
Welcome to Allied Telesyn
Where to Find Web-based Guides....................................................................vii
Document Conventions..................................................................................... vii
Contacting Allied Telesyn ...............................................................................viii
Online Support .........................................................................................viii
For Technical Support and Services........................................................viii
Technical Support E-mail Addresses ......................................................viii
Returning Products............................................................................................ ix
FTP Server ......................................................................................................... ix
For Sales or Corporate Information................................................................... x
Tell Us What You Think..................................................................................... x
Overview
Installing the Expansion Module....................................................................... 2
Verifying the Package Contents ................................................................. 2
Reviewing Safety Guidelines ......................................................................3
Reviewing Connectivity Guidelines............................................................4
Handling the Module................................................................................... 5
Installing the Module..................................................................................5
LEDs.................................................................................................................... 8
Troubleshooting .................................................................................................. 8
Warranty Registration ....................................................................................... 8
Technical Specifications ..................................................................................... 9
.......................................................................................................... 1
........................................................................................... v
.........................................................................vii
..............................................iii
Appendix A Translated Safety and Emission Information
Appendix B Technical Support Fax Order
Incident Summary............................................................................................ 23
Appendix C AT-B15 and AT-B17 Quick Install Guide Feedback
................................................................... 23
....................................... 11
.............................25
v

Welcome to Allied Telesyn

This guide contains instructions on how to install an AT-B15/SX, AT-B15/LX, or AT-B17 expansion module in an AT-8324SX Fast Ethernet Switch.

Where to Find Web-based Guides

The Allied Telesyn web site at easy way to access the most recent documentation and technical information for all of our products. All web-based documents relating to this product and other Allied Telesyn products can be downloaded from the web site in pdf format.
www.alliedtelesyn.com
provides you with an

Document Conventions

This guide uses several conventions that you should become familiar with first before you begin to install the product.
Note
A note provides additional information.
Caution
A caution indicates that performing or omitting a specific action may result in equipment damage or loss of data.
Warning
A warning indicates that performing or omitting a specific action may result in bodily injury.
vii

Contacting Allied Telesyn

There are several ways to contact Allied Telesyn technical support: online, telephone, fax and e-mail.

Online Support

You can request technical support online by filling out the Tech-Assistant Form at

For Technical Support and Services

www.alliedtelesyn.com/support.htm
.
Americas
United States, Canada, Mexico, Central America, South A m erica Tel: 1 (800) 428-4835, option 4 Fax: 1 (503) 639-3176
Asia
Singapore, Taiwan, Thailand, Malaysia, Indonesia, Korea, Philippines, China, India, Hong Kong Tel: (+65) 381-5612 Fax: (+65) 383-3830
Australia
Tel: 1 (800) 000-880 Fax: (+61) 2-9438-4966
France
France, Belgium, Luxembourg, The Netherlands, Middle East, Africa Tel: (+33) 0-1-60-92-15-25 Fax: (+33) 0-1-69-28-37-49

Technical Support E-mail Addresses

United States and Canada
TS1@alliedtelesyn.com
Germany
Germany, Switzerland, Austria, Eastern Europe Tel: (+49) 0130/83-56-66 Fax: (+49) 30-435-900-115
Italy
Italy, Spain, Portugal, Greece, Turkey, Israel Tel: (+39) 02-416047 Fax: (+39) 02-419282
Japan
Tel: (+81) 3-3443-5640 Fax: (+81) 3-3443-2443
United Kingdom
United Kingdom, Denmark, Norway, Sweden, Finland Tel: (+0044) 1235-442500 Fax: (+44) 1-235-442680
Latin America, Mexico, Puerto Rico, Caribbean, and Virgin Islands
latin_america@alliedtelesyn.com
United Kingdom, Sweden, Norway, Denmark, and Finland
support_europe@alliedtelesyn.com
viii
AT-B15 and AT-B17 Quick Install Guide

Returning Products

Products for return or repair must first be assigned a Return Materials Authorization (RMA) number. A product sent to Allied Telesyn without a RMA number will be returned to the sender at the sender’s expense.
To obtain an RMA number, contact Allied Telesyn’s Technical Support at one of the following locations:
North America
2205 Ringwood Ave San Jose, CA 95131 Tel: 1-800-428-4835, option 4 Fax: 1-503-639-3716
Latin America, the Caribbean, Virgin Islands
Tel: international code + 425-481-3852 Fax: international code + 425-483-9458
European Customer Support Centre
10/11 Bridgemead Close Westmead Industrial Estate Swindon, Wiltshire SN5 7YT England Tel: +44-1793-501401 Fax: +44-1793-431099
Mexico and Puerto Rico
Tel: 1-800-424-5012, ext 3852 or
1-800-424-4284, ext 3852
Mexico only: 95-800-424-5012, ext 3852 Fax: international code + 425-489-9191

FTP Server

If you know the name of a specific driver that you need for an Allied Telesyn device, you can download the software by connecting directly to our FTP server at
At login, enter ‘anonymous’. Enter your e-mail address for the password as requested by the server at login.
ftp://gateway.centre.com
.
ix

For Sales or Corporate Information

Allied Telesyn International, Corp.
19800 North Creek Parkway, Suite 200 Bothell, WA 98011 Tel: 1 (425) 487-8880 Fax: 1 (425) 489-9191
Allied Telesyn International, Corp.
960 Stewart Drive, Suite B Sunnyvale, CA 94086 Tel: 1 (800) 424-4284 (USA and Canada) Fax: 1 (408) 736-0100

Tell Us What You Think

If you have any comments or suggestions on how we might improve this or other Allied Telesyn documents, please fill out the “AT-B15 and AT-B17 Quick Install Guide Feedback” on page 25 and return the form to us at the address or fax number provided. You can also provide feedback online by filling out the Feedback on Documentation form at
feedbackman.htm
.
www.alliedtelesyn.com/forms/
x

Overview

The AT-B15/SX, AT-B15/LX, and AT-B17/SM are optional expansion modules for the AT-8324SX Fast Ethernet Switch. These expansion modules can be used to extend your network to remote sites, build a Fast Ethernet or Gigabit Ethernet backbone, or connect additional nodes to the network, such as high­speed servers.
Table 1 lists the basic specifications of the modules.
Table 1 Expansion Modules
Model Number and Type of Ports Maximum Distance
AT-B15/SX One 1000BASE-SX port 550 m (1805 ft)
AT-B15/LX One 1000BASE-LX port 5 km (3 mi)
AT-B17 Two 100BASE-FX ports 2 km (1.24 mi)
1. The maximum distance can be less depending on the type of fiber optic cabling used with the port and the duplex mode of the end node.
Caution
The expansion modules are designed for the AT-8324SX Fast Ethernet Switch only. Do not install these modules in any other Allied Telesyn device.
1
1
Loading...
+ 25 hidden pages