Allied Telesis AT-B17 User Manual

AT-B15/SX AT-B15/LX AT-B17 Expansion Modules
For the AT-8324SX Fast Ethernet Switch
Quick Install Guide
Copyright 2000 Allied Telesyn International, Corp. 960 Stewart Drive Suite B, Sunnyvale CA 94086 USA
All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesyn International, Corp.
Ethernet is a registered trademark of Xerox Corporation. All other product names, company names, logos or other designations mentioned herein are trademarks or registered trademarks of their respective owners.
Allied Telesyn International, Corp. reserves the right to make changes in specifications and other information contained in this document without prior written notice. The information provided herein is subject to change without notice. In no event shall Allied Telesyn International, Corp. be liable for any incidental, special, indirect, or consequential damages whatsoever, including but not limited to lost profits, arising out of or related to this manual or the information contained herein, even if Allied Telesyn International Corp. has been advised of, known, or should have known, the possibility of such damages.

Electrical Safety and Emission Statement

Standards
RADIATED ENERGY Note: This equipment has been tested and found to comply with the limits for a Class A
digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with this instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Note: Modifications or changes not expressly approved of by the manufacturer or the FCC, can void your right to operate this equipment.
This Class A digital apparatus meets all requirements of the Canadian Interference­Causing Equipment Regulations.
Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.
RFI Emission EN55022 Class A (CISPR 22)
WARNING
which case the user may be required to take adequate measures. Immunity IEC 1000-4-2 (4 kV CD, 8 kV AD)
Important
equipment. When you see the your language.
Wichtig
Geräts. Wenn Sie Sicherheitshinweis in Ihrer Sprache nach.
Vigtigt
dette udstyr. Når De ser symbolet sikkerhedsadvarsler i Deres eget sprog.
Belangrijk
deze apparatuur. Wanneer u de veiligheidsinstructies in uw taal.
Important
équipement. Lorsque vous voyez le symbole la traduction de ces instructions dans votre langue.
Tärkeää
Kun näe
Importante
questa apparecchiatura. Il simbolo sicurezza nella propria lingua.
: This product meets the following standards.
U.S. Federal Communications Commission
Industry Canada
!
1
EN60555-2 (1995) Class A EN60555-3
: In a domestic environment this product may cause radio interference in
IEC 1000-4-3 (1995) (3 V/m) IEC 1000-4-4 (1995) (1.0 kV - (power line);
0.5 kV - (signal line)) IEC 1000-4-6 (1995) (3 Vrms) EN50082-1 (1992) EN61000-4-2 (1995) EN61000-4-4 (1995)
: Appendix A contains translated safety statements for installing this
: Anhang A enthält übersetzte Sicherheitshinweise für die Installation dieses
: Tillæg A indeholder oversatte sikkerhedsadvarsler, der vedrører installation af
!
: Appendix A bevat vertaalde veiligheidsopmerkingen voor het installeren van
: L'annexe A contient les instructions de sécurité relatives à l'installation de cet
: Liite A sisältää tämän laitteen asentamiseen liittyvät käännetyt turvaohjeet.
!
-symbolin, katso käännettyä turvaohjetta liitteestä A.
: l’Appendice A contiene avvisi di sicurezza tradotti per l’installazione di
!
, go to Appendix A for the translated safety statement in
sehen, schlagen Sie in Anhang A den übersetzten
!
, skal De slå op i tillæg A og finde de oversatte
!
ziet, raadpleeg Appendix A voor vertaalde
!
, reportez-vous à l'annexe A pour consulter
!
, indica di consultare l’Appendice A per l’avviso di
!
2
!
3
iii
Viktig
: Tillegg A inneholder oversatt sikkerhetsinformasjon for installering av dette utstyret. Når du ser sikkerhetsinformasjonen på ønsket språk.
Importante
equipamento. Quando vir o símbolo idioma no Anexo A.
Importante
instalación de este equipo. Cuando vea el símbolo mensaje de seguridad traducido a su idioma.
Obs
! Bilaga A innehåller översatta säkerhetsmeddelanden avseende installationen av denna utrustning. När du ser säkerhetsmeddelandet på ditt språk.
!
, åpner du til Tillegg A for å finne den oversatte
: O Anexo A contém advertências de segurança traduzidas para instalar este
: El Apéndice A contiene mensajes de seguridad traducidos para la
!
, leia a advertência de segurança traduzida no seu
!
, vaya al Apéndice A para ver el
!
, skall du gå till Bilaga A för att läsa det översatta
iv

Table of Contents

Electrical Safety and Emission Statement
Table of Contents
Welcome to Allied Telesyn
Where to Find Web-based Guides....................................................................vii
Document Conventions..................................................................................... vii
Contacting Allied Telesyn ...............................................................................viii
Online Support .........................................................................................viii
For Technical Support and Services........................................................viii
Technical Support E-mail Addresses ......................................................viii
Returning Products............................................................................................ ix
FTP Server ......................................................................................................... ix
For Sales or Corporate Information................................................................... x
Tell Us What You Think..................................................................................... x
Overview
Installing the Expansion Module....................................................................... 2
Verifying the Package Contents ................................................................. 2
Reviewing Safety Guidelines ......................................................................3
Reviewing Connectivity Guidelines............................................................4
Handling the Module................................................................................... 5
Installing the Module..................................................................................5
LEDs.................................................................................................................... 8
Troubleshooting .................................................................................................. 8
Warranty Registration ....................................................................................... 8
Technical Specifications ..................................................................................... 9
.......................................................................................................... 1
........................................................................................... v
.........................................................................vii
..............................................iii
Appendix A Translated Safety and Emission Information
Appendix B Technical Support Fax Order
Incident Summary............................................................................................ 23
Appendix C AT-B15 and AT-B17 Quick Install Guide Feedback
................................................................... 23
....................................... 11
.............................25
v

Welcome to Allied Telesyn

This guide contains instructions on how to install an AT-B15/SX, AT-B15/LX, or AT-B17 expansion module in an AT-8324SX Fast Ethernet Switch.

Where to Find Web-based Guides

The Allied Telesyn web site at easy way to access the most recent documentation and technical information for all of our products. All web-based documents relating to this product and other Allied Telesyn products can be downloaded from the web site in pdf format.
www.alliedtelesyn.com
provides you with an

Document Conventions

This guide uses several conventions that you should become familiar with first before you begin to install the product.
Note
A note provides additional information.
Caution
A caution indicates that performing or omitting a specific action may result in equipment damage or loss of data.
Warning
A warning indicates that performing or omitting a specific action may result in bodily injury.
vii

Contacting Allied Telesyn

There are several ways to contact Allied Telesyn technical support: online, telephone, fax and e-mail.

Online Support

You can request technical support online by filling out the Tech-Assistant Form at

For Technical Support and Services

www.alliedtelesyn.com/support.htm
.
Americas
United States, Canada, Mexico, Central America, South A m erica Tel: 1 (800) 428-4835, option 4 Fax: 1 (503) 639-3176
Asia
Singapore, Taiwan, Thailand, Malaysia, Indonesia, Korea, Philippines, China, India, Hong Kong Tel: (+65) 381-5612 Fax: (+65) 383-3830
Australia
Tel: 1 (800) 000-880 Fax: (+61) 2-9438-4966
France
France, Belgium, Luxembourg, The Netherlands, Middle East, Africa Tel: (+33) 0-1-60-92-15-25 Fax: (+33) 0-1-69-28-37-49

Technical Support E-mail Addresses

United States and Canada
TS1@alliedtelesyn.com
Germany
Germany, Switzerland, Austria, Eastern Europe Tel: (+49) 0130/83-56-66 Fax: (+49) 30-435-900-115
Italy
Italy, Spain, Portugal, Greece, Turkey, Israel Tel: (+39) 02-416047 Fax: (+39) 02-419282
Japan
Tel: (+81) 3-3443-5640 Fax: (+81) 3-3443-2443
United Kingdom
United Kingdom, Denmark, Norway, Sweden, Finland Tel: (+0044) 1235-442500 Fax: (+44) 1-235-442680
Latin America, Mexico, Puerto Rico, Caribbean, and Virgin Islands
latin_america@alliedtelesyn.com
United Kingdom, Sweden, Norway, Denmark, and Finland
support_europe@alliedtelesyn.com
viii
AT-B15 and AT-B17 Quick Install Guide

Returning Products

Products for return or repair must first be assigned a Return Materials Authorization (RMA) number. A product sent to Allied Telesyn without a RMA number will be returned to the sender at the sender’s expense.
To obtain an RMA number, contact Allied Telesyn’s Technical Support at one of the following locations:
North America
2205 Ringwood Ave San Jose, CA 95131 Tel: 1-800-428-4835, option 4 Fax: 1-503-639-3716
Latin America, the Caribbean, Virgin Islands
Tel: international code + 425-481-3852 Fax: international code + 425-483-9458
European Customer Support Centre
10/11 Bridgemead Close Westmead Industrial Estate Swindon, Wiltshire SN5 7YT England Tel: +44-1793-501401 Fax: +44-1793-431099
Mexico and Puerto Rico
Tel: 1-800-424-5012, ext 3852 or
1-800-424-4284, ext 3852
Mexico only: 95-800-424-5012, ext 3852 Fax: international code + 425-489-9191

FTP Server

If you know the name of a specific driver that you need for an Allied Telesyn device, you can download the software by connecting directly to our FTP server at
At login, enter ‘anonymous’. Enter your e-mail address for the password as requested by the server at login.
ftp://gateway.centre.com
.
ix

For Sales or Corporate Information

Allied Telesyn International, Corp.
19800 North Creek Parkway, Suite 200 Bothell, WA 98011 Tel: 1 (425) 487-8880 Fax: 1 (425) 489-9191
Allied Telesyn International, Corp.
960 Stewart Drive, Suite B Sunnyvale, CA 94086 Tel: 1 (800) 424-4284 (USA and Canada) Fax: 1 (408) 736-0100

Tell Us What You Think

If you have any comments or suggestions on how we might improve this or other Allied Telesyn documents, please fill out the “AT-B15 and AT-B17 Quick Install Guide Feedback” on page 25 and return the form to us at the address or fax number provided. You can also provide feedback online by filling out the Feedback on Documentation form at
feedbackman.htm
.
www.alliedtelesyn.com/forms/
x

Overview

The AT-B15/SX, AT-B15/LX, and AT-B17/SM are optional expansion modules for the AT-8324SX Fast Ethernet Switch. These expansion modules can be used to extend your network to remote sites, build a Fast Ethernet or Gigabit Ethernet backbone, or connect additional nodes to the network, such as high­speed servers.
Table 1 lists the basic specifications of the modules.
Table 1 Expansion Modules
Model Number and Type of Ports Maximum Distance
AT-B15/SX One 1000BASE-SX port 550 m (1805 ft)
AT-B15/LX One 1000BASE-LX port 5 km (3 mi)
AT-B17 Two 100BASE-FX ports 2 km (1.24 mi)
1. The maximum distance can be less depending on the type of fiber optic cabling used with the port and the duplex mode of the end node.
Caution
The expansion modules are designed for the AT-8324SX Fast Ethernet Switch only. Do not install these modules in any other Allied Telesyn device.
1
1
Figure 1 through Figure 3 illustrate the expansion modules.
Figure 1 AT-B15/SX Expansion Module
Figure 2 AT-B15/LX Expansion Module
Figure 3 AT-B17 Expansion Module

Installing the Expansion Module

The following sections contain the instructions on how to install an expansion module in the switch.

Verifying the Package Contents

Check to be sure that your module package contains the following items. If any of the items are missing or damaged, contact your Allied Telesyn representative.
"
One AT-B15/SX, AT-B15/LX, or AT-B17 Expansion Module
"
Warranty Card
"
This Quick Install Guide
2
AT-B15 and AT-B17 Quick Install Guide

Reviewing Safety Guidelines

Please review the following safety guidelines before you begin to install the expansion module in the switch.
Warning
Class 1 laser product. !4
Warning
Do not stare into the laser beam. !5
Warning Electric Shock Hazard
cover. There are no user-serviceable parts inside. The unit contains hazardous voltages and should only be opened by a trained and qualified technician. !6
Warning Lightning Danger
periods of lightning activity. !7
Warning Power cord is used as a disconnection device:
equipment, disconnect the power cord. !8
: To prevent electric shock, do not remove the
: Do not work on this equipment or cables during
To de-energize
Warning Electrical-Type Class 1 Equipment
: This equipment must be earthed. The power plug must be connected to a properly wired earth ground socket outlet. An improperly wired socket outlet could place hazardous voltages on accessible metal parts. !9
Caution Pluggable Equipment
: The socket outlet should be installed near the
equipment and should be easily accessible. !10
Caution Air vents
: The air vents must not be blocked on the unit and must have
free access to the room ambient air for cooling. !11
Caution Operating Temperature
: This product is designed for a maximum
ambient temperature of 50°C. !12
Caution All Countries
: Install this product in accordance with local and
National Electric Codes. !13
3

Reviewing Connectivity Guidelines

The AT-B15/SX has one 1000BASE-SX fiber optic port with an SC connector. This module operates at 1Gbps and supports auto-negotiation for duplex mode (half- or full-duplex) and flow control. Refer to Table 2 for the cabling specifications for this module.
Table 2 Cabling Specifications for the AT-B15/SX Expansion Module
Cable Fiber Bandwidth
62.5/125 micron multi­mode fiber
50/125 micron multi-
160 MHz/km 2-220 m (7-722 ft)
200MHz/km 2-275 m (7-902 ft)
400MHz/km 2-500 m (7-1641 ft)
Minimum to Maximum Cable Length
mode fiber
500 MHz/km 2-550 m (7-1805 ft)
The AT-B15/LX has one 1000BASE-LX fiber optic port with an SC connector. This module operates at 1Gbps and supports auto-negotiation for duplex mode (half- or full-duplex) and flow control. Refer to Table 3 for the cabling specifications for this module.
Table 3 Cabling Specifications for the AT-B15/LX Expansion Module
Cable Fiber Bandwidth
62.5/125 micron multi-
500 MHz/km 2-550 m (7-1805 ft)
Minimum to Maximum Cable Length
mode fiber
50/125 micron multi-
400MHz/km 2-550 m (7-1805 ft)
mode fiber
500 MHz/km 2-550 m (7-1805 ft)
9/125 micron single-
N/A 2-5 km (7-16,404 ft)
mode fiber
The AT-B17 expansion module has two 100BASE-FX ports with SC connectors. For cabling specifications for this module, refer to the
Fast Ethernet Switch Installation Guide
4
.
AT-8324SX
AT-B15 and AT-B17 Quick Install Guide

Handling the Module

Caution
The expansion module can easily be damaged by electrostatic discharge.
To prevent electrostatic damage, observe the following guidelines:
"
Wear an anti-static wristband connected to a suitable earth ground whenever handling the module.
"
Do not remove the module from its packaging until you are ready to install it.
"
Do not touch any of the module’s pins, connectors or components.
"
Hold the module only by its edges or front panel.
"
Store or transport this module only in appropriate anti-static packaging.

Installing the Module

To install the expansion module, perform the following procedure:
1. Power off the switch by disconnecting the AC power cord from the switch. If a redundant power unit (RPU) is present, disconnect its DC cable connection to the switch.
Caution
The switch must be powered off before installing or replacing any module. Installing a module with the switch powered on can damage the module.
2. Using a flathead screwdriver, remove the faceplate from either the lower
right (slot A) or the lower left (slot B) expansion slot, as shown in Figure 4.
Allied Telesyn recommends installing the module in the lower right expansion slot (slot A) and reserving the lower left slot for the optional AT-STACK1 Stacking Module.
Caution
Do not install the expansion module in the upper expansion slot (slot MGMT). This slot is reserved for the optional AT-BMGMT Management Module.
5
Figure 4 Removing a Faceplate
Note
Keep the original faceplate for future use. If you should remove the module, replace the faceplate to prevent dust and debris from entering the unit and to maintain proper air flow.
Caution
Be sure to wear an anti-static wristband while performing the next step. The AT-STACK1 module can be damaged by electrostatic discharge.
6
AT-B15 and AT-B17 Quick Install Guide
3. Insert the new module into the switch. Holding the new module with the
text on the front panel upright, carefully slide the module into the switch slot, ensuring that the edge connector is fully engaged. Once the new module is installed, check to be sure the front panel of the module is flush against the switch.
Figure 5 Installing the Expansion Module
4. Using a flathead screwdriver, secure the new module to the switch by
tightening the attached screws.
5. Connect the fiber optic cable(s) to the port(s) on the newly installed
module.
6. Power on the switch by reconnecting the previously removed power sources
to the switch. The switch’s front-panel LEDs should indicate their status of the new connection. Check the LED indicators for the fiber ports to ensure that they are operating properly. Refer to the table of LEDs in this guide for a description of the LED indications. If the module does not respond, see "Troubleshooting" below.
More details concerning connection options and network applications can be found in the
AT-8324SX Fast Ethernet Switch Installation Guide
, which is
available from the Allied Telesyn web site.
7

LEDs

The front panel of the switch has several LEDs that report the status of the port(s) on the expansion module. Table 4 defines the LEDs.
Table 4 Expansion Module LEDs
LED Condition Status
STATUS On A module is installed in the slot.
ACT Flashing Traffic is passing through the port.

Troubleshooting

If you experience any problems with the module, check the following items before contacting Allied Telesyn Technical Support:
"
Ensure the switch with the module is powered up.
"
Ensure that the device attached to the module is powered up and operating correctly.
"
Ensure that the module is properly seated in the slot.
"
Verify that the module port is configured to match the communication mode used by the attached device.
"
Check the connectors on both ends of the cable to be sure they are properly engaged. When attaching fiber cable to an SC-type port, be sure the plug clicks into place to ensure that it is properly seated.
"
If you are using fiber optic cable with an ST-type connector (in conjunction with an SC-ST converter), try switching the TX and RX connectors. Also, be sure the fiber terminators are clean. Dirty fiber terminators on fiber optic cables will impair the quality of the light transmitted through the cable.

Warranty Registration

When you are finished installing the module, register your product by completing the enclosed warranty card and sending it in, or by visiting our web site at the on-line registration form.
8
www.alliedtelesyn.com/forms/warranty.htm
and completing
AT-B15 and AT-B17 Quick Install Guide

Technical Specifications

Table 5 lists the technical specifications for the expansion modules.
Table 5 Technical Specifications
Ports
AT-B15/SX
AT-B15/LX
AT-B17
Cable Type
AT-B15/SX
AT-B15/LX
AT-B17
Switching Method
Filtering/Forwarding
Queue Buffer
AT-B15/SX
AT-B15/LX
AT-B17
Power Consumption
One 1000BASE-SX with SC connector
One 1000BASE-LX with SC connector
Two 100BASE-FX with SC connectors
50/125 or 62.5/125 micron multimode fiber
50/125 or 62.5/125 micron multimode fiber
50/125 or 62.5/125 micron multimode or 9/125 micron single-mode fiber
Store-and-forward
Full line speed
2 Mbytes
2 Mbytes
128K bytes per port
AT-B15/SX
AT-B15/LX
AT-B17
Temperature
Operating Humidity
2.4W maximum
2.4W maximum
10.6W maximum
Operating: 32° to 122° F (0° to 50° C) Storage: -4° to 158° F (-20° to 70° C)
5% to 95% (non-condensing)
9
Compliances
Standards
Table 5 Technical Specifications
CE Mark EN55022 (CISPR22) Class A VCCI Class A C-Tick
AT-B15/SX
AT-B15/LX
AT-B17
Certification
Emissions
Immunity
CE Mark
IEEE 802.3z, ISO/IEC 8802-3
IEEE 802.3z, ISO/IEC 8802-3
IEEE 802.3, IEEE 802.3u, ISO/IEC 8802-3
FCC Class A, VCCI Class A, CISPR Class A
IEC 1000-4-2/3/4/6
10

Appendix A

Translated Safety and Emission Information

Important
safety statements in this guide.
Wichtig
enthaltenen Sicherheitshinweise in mehreren Sprachen.
Vigtigt
sikkerhedsadvarslerne i denne håndbog.
Belangrijk
veiligheidsopmerkingen in deze gids.
Important
instructions de sécurité figurant dans ce guide.
Tärkeää
kielellä.
Importante
sicurezza di questa guida.
Viktig
sikkerhetsinformasjonen i denne veiledningen.
Importante
de segurança neste guia.
Importante
mensajes de seguridad incluidos en esta guía.
: This appendix contains multiple-language translations for the
: Dieser Anhang enthält Übersetzungen der in diesem Handbuch
: Dette tillæg indeholder oversættelser i flere sprog af
: Deze appendix bevat vertalingen in meerdere talen van de
: Cette annexe contient la traduction en plusieurs langues des
: Tämä liite sisältää tässä oppaassa esiintyvät turvaohjeet usealla
: questa appendice contiene traduzioni in più lingue degli avvisi di
: Dette tillegget inneholder oversettelser til flere språk av
: Este anexo contém traduções em vários idiomas das advertências
: Este apéndice contiene traducciones en múltiples idiomas de los
Obs
! Denna bilaga innehåller flerspråkiga översättningar av
säkerhetsmeddelandena i denna handledning.
11
Standards
RADIATED ENERGY
Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with this instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Note: Modifications or changes not expressly approved of by the manufacturer or the FCC, can void your right to operate this equipment.
This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.
Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.
!
1
!
2 WARNING
!
3
!
4 WARNING
!
5 WARNING
!
6 ELECTRICAL NOTICES
!
7 LIGHTNING DANGER
!
8CAUTION:
RFI Emission EN55022 Class A
which case the user may be required to take adequate measures.
Immunity IEC 1000-4-2 (4 kV CD, 8 kV AD)
SAFETY
WARNING:
To prevent ELECTRIC shock, do not remove the cover. No user-serviceable parts inside. This unit contains HAZARDOUS VOLTAGES and should only be opened by a trained and qualified technician. To avoid the possibility of ELECTRIC SHOCK, disconnect electric power to the product before connecting or disconnecting the LAN cables.
DANGER:
LIGHTNING ACTIVITY.
ENERGIZE EQUIPMENT, disconnect the power cord.
: This product meets the following standards.
: In a domestic environment this product may cause radio interference in
: Class 1 Laser product.
: Do not stare into the laser beam.
ELECTRIC SHOCK HAZAR
DO NOT WORK on equipment or CABLES during periods of
POWER CORD IS USED AS A DISCONNECTION DEVICE. TO DE-
U.S. Federal Communications Commission
Industry Canada
EN60555-2 (1995) Class A EN60555-3
IEC 1000-4-3 (1995) (3 V/m) IEC 1000-4-4 (1995) (1.0 kV - (power line);
0.5 kV - (signal line)) IEC 1000-4-6 (1995) (3 Vrms) EN50082-1 (1992) EN61000-4-2 (1995) EN61000-4-4 (1995)
D
12
!
9
!
10
!
11 CAUTION:
!
12 OPERATING TEMPERATURE:
!
13 ALL COUNTRIES:
!
1
!
2 WARNUNG
!
3
!
4 WARNUNG
!
5 WARNUNG
!
6ACHTUNG:
!
7 GEFAHR DURCH BLITZSCHLAG
!
8VORSICHT:
!
9
!
10
ELECTRICAL - TYPE CLASS 1 EQUIPMENT THIS EQUIPMENT MUST BE EARTHED. Power plug must be connected to a properly wired earth ground socket outlet. An improperly wired socket outlet could place hazardous voltages on accessible metal parts.
PLUGGABLE EQUIPMENT, the socket outlet shall be installed near the equipment and shall be easily accessible.
ambient air for cooling.
temperature of 50° degrees C.
Codes.
Normen
Hochfrequenzstörung EN55022 Klasse A
hervorrufen. In diesem Fall müßte der Anwender angemessene Gegenmaßnahmen ergreifen.
Störsicherheit IEC 1000-4-2 (4 kV CD, 8 kV AD)
SICHERHEIT
Das Gehäuse nicht öffnen. Das Gerät enthält keine vom Benutzer wartbaren Teile. Das Gerät steht unter Hochspannung und darf nur von qualifiziertem technischem Personal geöffnet werden. Vor Anschluß der LAN-Kabel, Gerät vom Netz trennen.
GEFAHR:
ausführen.
STROMVERSORGUNG. ZUR TRENNUNG VOM NETZ, KABEL AUS DE STECKDOSE ZIEHEN.
GERÄTE DER KLASSE 1 DIESE GERÄTE MÜSSEN GEERDET SEIN. Der Netzstecker darf nur mit einer vorschriftsmäßig geerdeten Steckdose verbunden werden. Ein unvorschriftsmäßiger Anschluß kann die Metallteile des Gehauses unter gefährliche elektrische Spannungen setzen.
STECKBARES GERÄT: Die Anschlußbuchse sollte in der Nähe der Einrichtung angebracht werden und leicht zugänglich sein."
Air vents must not be blocked and must have free access to the room
Install product in accordance with local and National Electrical
: Dieses Produkt erfüllt die Anforderungen der nachfolgenden Normen.
: Bei Verwendung zu Hause kann dieses Produkt Funkstörungen
Laserprodukt der Klasse 1.
Nicht direkt in den Strahl blicken.
GEFÄHRLICHE SPANNUNG
Keine Arbeiten am Gerät oder an den Kabeln während eines Gewitters
DAS NETZKABEL DIENT ZUM TRENNEN DE
AT-B15 and AT-B17 Quick Install Guide
This product is designed for a maximum ambient
EN60555-2 (1995) Klasse A EN60555-3
IEC 1000-4-3 (1995) (3 V/m) IEC 1000-4-4 (1995) (1.0 kV - (power line);
0.5 kV - (signal line)) IEC 1000-4-6 (1995) (3 Vrms) EN50082-1 (1992) EN61000-4-2 (1995) EN61000-4-4 (1995)
13
!
11 VORSICHT
!
12 BETRIEBSTEMPERATUR:
!
13 ALLE LÄNDER:
Die Entlüftungsöffnungen dürfen nicht versperrt sein und müssen zum Kühlen freien Zugang zur Raumluft haben.
Umgebungstemperatur von nicht mehr als 50° C entworfen.
Installation muß örtlichen und nationalen elektrischen
Vorschriften entsprechen.
Dieses Produkt wurde für den Betrieb in einer
Standarder
!
1
!
2ADVARSEL
!
3
!
4ADVARSEL
!
5ADVARSEL
!
6 ELEKTRISKE FORHOLDSREGLER
!
7 FARE UNDER UVEJR
!
8ADVARSEL:
!
9
!
10
!
11 ADVARSEL:
!
12 BETJENINGSTEMPERATUR:
Radiofrekvens forstyrrelsesemission EN55022 Klasse
Bliver det tilfældet, påkræves brugeren muligvis at tage tilstrækkelige foranstaltninger.
Immunitet IEC 1000-4-2 (4 kV CD, 8 kV AD)
SIKKERHED
ADVARSEL:
For at forebygge ELEKTRISK stød, undlad at åbne apparatet. Der er ingen indre dele, der kan repareres af brugeren. Denne enhed indeholder LIVSFARLIGE STRØMSPÆNDINGER og bør kun åbnes af en uddannet og kvalificeret tekniker. For at undgå risiko for ELEKTRISK STØD, afbrydes den elektriske strøm til produktet, før LAN-kablerne monteres eller afmonteres.
FARE:
LYNAKTIVITET.
STRØMMEN. SKAL STRØMMEN TIL APPARATET AFBRYDES, tages ledningen ud af stikket.
ELEKTRISK - KLASSE 1-UDSTYR DETTE UDSTYR KRÆVER JORDFORBINDELSE. Stikket skal være forbundet med en korrekt installeret jordforbunden stikkontakt. En ukorrekt installeret stikkontakt kan sætte livsfarlig spænding til tilgængelige metaldele.
UDSTYR TIL STIKKONTAKT, stikkontakten bør installeres nær ved udstyret og skal være lettilgængelig.
omgivende luft i rummet for afkøling.
temperatur på maksimum 50 grader C.
: Dette produkt tilfredsstiller de følgende standarder.
: I et hjemligt miljø kunne dette produkt forårsage radio forstyrrelse.
Laserprodukt av klasse 1.
Stirr ikke på strålen.
RISIKO FOR ELEKTRISK STØD
UNDLAD at arbejde på udstyr eller KABLER i perioder med
DEN STRØMFØRENDE LEDNING BRUGES TIL AT AFBRYDE
Ventilationsåbninger må ikke blokeres og skal have fri adgang til den
A
EN60555-2 (1995) Klasse EN60555-3
IEC 1000-4-3 (1995) (3 V/m) IEC 1000-4-4 (1995) (1.0 kV - (power line);
0.5 kV - (signal line)) IEC 1000-4-6 (1995) (3 Vrms) EN50082-1 (1992) EN61000-4-2 (1995) EN61000-4-4 (1995)
Dette apparat er konstrueret til en omgivende
A
14
AT-B15 and AT-B17 Quick Install Guide
!
13 ALLE LANDE:
!
1
!
2WAARSCHUWING
!
3
!
4WAARSHUWING
!
5 WAARCHUWING
!
6 WAARSCHUWINGEN MET BETREKKING TOT ELEKTRICITEIT
!
7 GEVAAR VOOR BLIKSEMINSLAG
!
8WAARSCHUWING:
!
9
!
10
!
11 OPGELET:
!
12 BEDRIJFSTEMPERATUUR:
!
13 ALLE LANDEN:
national lovgivning for elektriske installationer.
Eisen
: Dit product voldoet aan de volgende eisen.
RFI Emissie EN55022 Klasse
geval de gebruiker verplicht kan worden om gepaste maatregelen te nemen.
Immuniteit IEC 1000-4-2 (4 kV CD, 8 kV AD)
VEILIGHEID
WAARSCHUWING:
Verwijder het deksel niet, teneinde ELEKTRISCHE schokken te voorkomen. Binnenin bevinden zich geen onderdelen die door de gebruiker onderhouden kunnen worden. Dit toestel staat onder GEVAARLIJKE SPANNING en mag alleen worden geopend door een daartoe opgeleide en bevoegde technicus. Om het gevaar op ELEKTRISCHE SCHOKKEN te vermijden, moet u het toestel van de stroombron ontkoppelen alvorens de LAN-kabels te koppelen of ontkoppelen.
GEVAAR:
STROOMKABEL TE ONTKOPPELEN.OM HET TOESTEL STROOMLOOS TE MAKEN: de stroomkabel ontkoppelen.
ELEKTRISCHE TOESTELLEN VAN KLASSE 1 DIT TOESTEL MOET GEAARD WORDEN. De stekker moet aangesloten zijn op een juist geaarde contactdoos. Een onjuist geaarde contactdoos kan de metalen onderdelen waarmee de gebruiker eventueel in aanraking komt onder gevaarlijke spanning stellen.
AAN TE SLUITEN APPARATUUR, de contactdoos wordt in de nabijheid van de apparatuur geïnstalleerd en is gemakkelijk te bereiken."
omgevingslucht ongehinderd toelaten voor afkoeling.
niet meer bedragen dan 50 graden Celsius.
elektrische voorschriften.
Installation af produktet skal ske i overensstemmelse med lokal og
EN60555-2 (1995) Klasse EN60555-3
: Binnenshuis kan dit product radiostoring veroorzaken, in welk
IEC 1000-4-3 (1995) (3 V/m) IEC 1000-4-4 (1995) (1.0 kV - (power line);
0.5 kV - (signal line)) IEC 1000-4-6 (1995) (3 Vrms) EN50082-1 (1992) EN61000-4-2 (1995) EN61000-4-4 (1995)
Klasse-1 laser produkt.
Neit in de straal staren.
GEVAAR VOOR ELEKTRISCHE SCHOKKEN
NIET aan toestellen of KABELS WERKEN bij BLIKSEM.
HET TOESTEL WORDT UITGESCHAKELD DOOR DE
De ventilatiegaten mogen niet worden gesperd en moeten de
De omgevingstemperatuur voor dit produkt mag
het toestel installeren overeenkomstig de lokale en nationale
A
A
15
Normes:
ce produit est conforme aux normes de suivantes:
!
1
!
2 MISE EN GARDE
!
3
!
4ATTENTION
!
5ATTENTION
!
6 INFORMATION SUR LES RISQUES ÉLECTRIQUES
!
7 DANGER DE FOUDRE
!
8 ATTENTION:
!
9
!
10
!
11 ATTENTION:
!
12 TEMPÉRATURE DE FONCTIONNEMENT:
!
13 POUR TOUS PAYS:
Emission d’interférences radioélectriques EN55022 Classe
des interférences radioélectriques. Auquel cas, l’utilisateur devra prendre les mesures adéquates.
Immunité IEC 1000-4-2 (4 kV CD, 8 kV AD)
SÉCURITÉ
AVERTISSEMENT
Pour éviter toute ÉLECTROCUTION, ne pas ôter le revêtement protecteur du matériel. Ce matériel ne contient aucun élément réparable par l’utilisateur. Il comprend des TENSIONS DANGEREUSES et ne doit être ouvert que par un technicien dûment qualifié. Pour éviter tout risque d’ÉLECTROCUTION, débrancher le matériel avant de connecter ou de déconnecter les câbles LAN.
DANGER:
POUR COUPER L’ALIMENTATION DU MATÉRIEL, débrancher le cordon.
ÉQUIPEMENT DE CLASSE 1 ÉLECTRIQUE CE MATÉRIEL DOIT ÊTRE MIS A LA TERRE. La prise de courant doit être branchée dans une prise femelle correctement mise à la terre car des tensions dangereuses risqueraient d’atteindre les pièces métalliques accessibles à l’utilisateur.
EQUIPEMENT POUR BRANCHEMENT ELECTRIQUE, la prise de sortie doit être placée près de l’équipement et facilement accessible".
de circuler librement pour le refroidissement.
une température ambiante maximum de ou 50 degrés Celsius.
nationales et locales.
: dans un environnement domestique, ce produit peut provoquer
Producit laser di classe 1.
Ne pas fixer le faisceau des yeux.
: DANGER D’ÉLECTROCUTION
NE PAS MANIER le matériel ou les CÂBLES lors d’activité orageuse.
LE CORDON D’ALIMENTATION SERT DE MISE HORS CIRCUIT.
Ne pas bloquer les fentes d’aération, ceci empêcherait l’air ambiant
Installer le matériel conformément aux normes électriques
EN60555-2 (1995) Classe EN60555-3
IEC 1000-4-3 (1995) (3 V/m) IEC 1000-4-4 (1995) (1.0 kV - (power line);
0.5 kV - (signal line)) IEC 1000-4-6 (1995) (3 Vrms) EN50082-1 (1992) EN61000-4-2 (1995) EN61000-4-4 (1995)
A
A
Ce matériel est capable de tolérer
16
AT-B15 and AT-B17 Quick Install Guide
Standardit
!
1
!
2
!
3
!
4VAROITUS
!
5VARIOTUS
!
6 SÄHKÖÖN LIITTYVIÄ HUOMAUTUKSIA
!
7 SALAMANISKUVAARA
!
8 HUOMAUTUS:
!
9
!
10
!
11 HUOMAUTUS:
!
12 KÄYTTÖLÄMPÖTILA:
!
13 KAIKKI MAAT:
Radioaaltojen häirintä EN55022 Luokka
VAROITUS: Kotiolosuhteissa tämä laite voi aiheuttaa radioaaltojen häiröitä, missä tapauksessa laitteen käyttäjän on mahdollisesti ryhdyttävä tarpeellisiin toimenpiteisiin.
Kestävyys IEC 1000-4-2 (4 kV CD, 8 kV AD)
TURVALLISUUS
VAROITUS:
Estääksesi SÄHKÖISKUN älä poista kantta. Sisällä ei ole käyttäjän huollettavissa olevia osia. Tämä laite sisältää VAARALLISIA JÄNNITTEITÄ ja sen voi avata vain koulutettu ja pätevä teknikko. Välttääksesi SÄHKÖISKUN mahdollisuuden katkaise sähkövirta tuotteeseen ennen kuin liität tai irrotat paikallisverkon (LAN) kaapelit.
HENGENVAARA:
SALAMOINNIN AIKANA.
VIRTA KATKAISTAAN irrottamalla virtajohto.
SÄHKÖ - TYYPPILUOKAN 1 LAITTEET TÄMÄ LAITE TÄYTYY MAADOITTAA. Pistoke täytyy liittää kunnollisesti maadoitettuun pistorasiaan. Virheellisesti johdotettu pistorasia voi altistaa metalliosat vaarallisille jännitteille.
PISTORASIAAN KYTKETTÄVÄ LAITE; pistorasia on asennettava laitteen lähelle ja siihen on oltava esteetön pääsy."
ympäröivään huoneilmaan, jotta ilmanvaihto tapahtuisi.
maksimilämpötilalle 50°C.
sähköturvallisuusmääräysten mukaisesti.
: Tämä tuote on seuraavien standardien mukainen.
Luokan 1 Lasertuote.
Älä katso säteeseen.
SÄHKÖISKUVAARA
ÄLÄ TYÖSKENTELE laitteiden tai KAAPELEIDEN KANSSA
VIRTAJOHTOA KÄYTETÄÄN VIRRANKATKAISULAITTEENA.
Ilmavaihtoreikiä ei pidä tukkia ja niillä täytyy olla vapaa yhteys
Tämä tuote on suunniteltu ympäröivän ilman
Asenna tuote paikallisten ja kansallisten
A
EN60555-2 (1995) Luokka EN60555-3
IEC 1000-4-3 (1995) (3 V/m) IEC 1000-4-4 (1995) (1.0 kV - (power line);
0.5 kV - (signal line)) IEC 1000-4-6 (1995) (3 Vrms) EN50082-1 (1992) EN61000-4-2 (1995) EN61000-4-4 (1995)
A
17
Standard
!
1
!
2 AVVERTENZA:
!
3
!
4 AVVERTENZA
!
5 AVERTENZA
!
6 AVVERTENZE ELETTRICHE
!
7 PERICOLO DI FULMINI
!
8 ATTENZIONE:
!
9
!
10
!
11 ATTENZIONE:
!
12 TEMPERATURA DI FUNZIONAMENTO:
!
13 TUTTI I PAESI:
Emissione RFI (interferenza di radiofrequenza) EN55022 Classe
interferenza. In questo caso potrebbe richiedersi all’utente di prendere gli adeguati provvedimenti.
Immunità IEC 1000-4-2 (4 kV CD, 8 kV AD)
NORME DI SICUREZZA
ATTENZIONE:
Per evitare SCOSSE ELETTRICHE non asportare il coperchio. Le componenti interne non sono riparabili dall’utente. Questa unità ha TENSIONI PERICOLOSE e va aperta solamente da un tecnico specializzato e qualificato. Per evitare ogni possibilità di SCOSSE ELETTRICHE, interrompere l’alimentazione del dispositivo prima di collegare o staccare i cavi LAN.
PERICOLO:
PRECIPITAZIONI TEMPORALESCHE.
DI DISATTIVAZIONE. PER TOGLIERE LA CORRENTE AL DISPOSITIVO staccare il cavo di alimentazione.
ELETTRICITÀ - DISPOSITIVI DI CLASSE 1 QUESTO DISPOSITIVO DEVE AVERE LA MESSA A TERRA. La spina deve essere inserita in una presa di corrente specificamente dotata di messa a terra. Una presa non cablata in maniera corretta rischia di scaricare una tensione pericolosa su parti metalliche accessibili.
APPARECCHIATURA COLLEGABILE, la presa va installata vicino all’apparecchio per risultare facilmente accessibile".
ricircolo dell’aria ambiente per il raffreddamento.
temperatura ambientale massima di 50 gradi centigradi.
elettriche nazionali.
: Questo prodotto è conforme ai seguenti standard.
in ambiente domestico questo prodotto potrebbe causare radio
Prodotto laser di Classe 1.
Non fissare il raggio con gli occhi.
PERICOLO DI SCOSSE ELETTRICHE
NON LAVORARE sul dispositivo o sui CAVI durante
IL CAVO DI ALIMENTAZIONE È USATO COME DISPOSITIVO
le prese d’aria non vanno ostruite e devono consentire il libero
installare il prodotto in conformità delle vigenti normative
A
EN60555-2 (1995) Classe EN60555-3
IEC 1000-4-3 (1995) (3 V/m) IEC 1000-4-4 (1995) (1.0 kV - (power line);
0.5 kV - (signal line)) IEC 1000-4-6 (1995) (3 Vrms) EN50082-1 (1992) EN61000-4-2 (1995) EN61000-4-4 (1995)
Questo prodotto è concepito per una
A
18
AT-B15 and AT-B17 Quick Install Guide
Sikkerhetsnormer
!
1
!
2ADVARSEL
!
3
!
4ADVARSEL
!
5ADVARSAL
!
6 ELEKTRISITET
!
7 FARE FOR LYNNEDSLAG
!
8 FORSIKTIG:
!
9
!
10
!
11 FORSIKTIG:
!
12 DRIFTSTEMPERATUR:
!
13 ALLE LAND:
RFI stråling EN55022 Klasse
radioforstyrrelse. Hvis dette skjer, må brukeren ta de nødvendige forholdsregler.
Immunitet IEC 1000-4-2 (4 kV CD, 8 kV AD)
SIKKERHET
ADVARSEL:
For å unngå ELEKTRISK sjokk, må dekslet ikke tas av. Det finnes ingen deler som brukeren kan reparere på innsiden. Denne enheten inneholder FARLIGE SPENNINGER, og må kun åpnes av en faglig kvalifisert tekniker. For å unngå ELEKTRISK SJOKK må den elektriske strømmen til produktet være avslått før LAN-kablene til- eller frakobles.
FARE:
FOR Å DEAKTIVISERE UTSTYRET, må strømforsyningen kobles fra.
ELEKTRISK - TYPE 1- KLASSE UTSTYR DETTE UTSTYRET MÅ JORDES. Strømkontakten må være tilkoplet en korrekt jordet kontakt. En kontakt som ikke er korrekt jordet kan føre til farlig spenninger i lett t ilgjengelige metalldeler.
UTSTYR FOR STIKKONTAKT. Stikkontakten skal monteres i nærheten av utstyret og skal være lett tilgjengelig."
romtemperatur for avkjøling.
romtemperatur på 50 grader celsius.
elektriske koder.
: Hvis dette produktet benyttes til privat bruk, kan produktet forårsake
Laserprodukt av klasse 1.
Stirr ikke på strålen.
FARE FOR ELEKTRISK SJOKK
ARBEID IKKE på utstyr eller KABLER i TORDENVÆR.
STRØMLEDNINGEN BRUKES TIL Å FRAKOBLE UTSTYRET.
Lufteventilene må ikke blokkeres, og må ha fri tilgang til luft med
Produktet må installeres i samsvar med de lokale og nasjonale
: Dette produktet tilfredsstiller følgende sikkerhetsnormer.
A
EN60555-2 (1995) Klasse EN60555-3
IEC 1000-4-3 (1995) (3 V/m) IEC 1000-4-4 (1995) (1.0 kV - (power line);
0.5 kV - (signal line)) IEC 1000-4-6 (1995) (3 Vrms) EN50082-1 (1992) EN61000-4-2 (1995) EN61000-4-4 (1995)
Dette produktet er konstruert for bruk i maksimum
A
19
Padrões
: Este produto atende aos seguintes padrões.
!
1
!
2AVISO
!
3
!
4AVISO
!
5AVISO
!
6 AVISOS SOBRE CARACTERÍSTICAS ELÉTRICAS
!
7 PERIGO DE CHOQUE CAUSADO POR RAIO
!
8 CUIDADO:
!
9
!
10
!
11 CUIDADO:
!
12 TEMPERATURA DE FUNCIONAMENTO:
!
13 TODOS OS PAÍSES:
Emissão de interferência de radiofrequênciaEN55022 Classe
: Num ambiente doméstico este produto pode causar interferência na radiorrecepção e, neste caso, pode ser necessário que o utente tome as medidas adequadas.
Imunidade IEC 1000-4-2 (4 kV CD, 8 kV AD)
SEGURANÇA
Produto laser de classe 1
Não olhe fixamente para o raio.
ATENÇÃO:
Para evitar CHOQUE ELÉTRICO, não retire a tampa. Não contém peças que possam ser consertadas pelo usuário. Este aparelho contém VOLTAGENS PERIGOSAS e só deve ser aberto por um técnico qualificado e treinado. Para evitar a possibilidade de CHOQUE ELÉTRICO, desconecte o aparelho da fonte de energia elétrica antes de conectar e desconectar os cabos da LAN.
PERIGO:
suscetíveis a QUEDAS DE RAIO.
DISPOSITIVO DE DESCONEXÃO. PARA DESELETRIFICAR O EQUIPAMENTO, desconecte o cabo de ALIMENTAÇÃO.
ELÉTRICO - EQUIPAMENTOS DO TIPO CLASSE 1 DEVE SER FEITA LIGAÇÃO DE FIO TERRA PARA ESTE EQUIPAMENTO. O plugue de alimentação deve ser conectado a uma tomada com adequada ligação de fio terra. Tomadas sem adequada ligação de fio terra podem transmitir voltagens perigosas a peças metálicas expostas.
EQUIPAMENTO DE LIGAÇÃO, a tomada eléctrica deve estar instalada perto do equipamento e ser de fácil acesso."
livre ao ar ambiente para arrefecimento adequado do aparelho.
temperatura ambiente máxima de 50 graus centígrados.
para instalações elétricas.
PERIGO DE CHOQUE ELÉTRICO
NÃO TRABALHE no equipamento ou nos CABOS durante períodos
O CABO DE ALIMENTAÇÃO É UTILIZADO COMO UM
As aberturas de ventilação não devem ser bloqueadas e devem ter acesso
Instale o produto de acordo com as normas nacionais e locais
EN60555-2 (1995) Classe EN60555-3
IEC 1000-4-3 (1995) (3 V/m) IEC 1000-4-4 (1995) (1.0 kV - (power line);
0.5 kV - (signal line)) IEC 1000-4-6 (1995) (3 Vrms) EN50082-1 (1992) EN61000-4-2 (1995) EN61000-4-4 (1995)
A
A
Este produto foi projetado para uma
20
AT-B15 and AT-B17 Quick Install Guide
Estándares:
!
1
!
2 ADVERTENCIA
!
3
!
4 ¡ADVERTENCIA!
!
5 ¡ADVERTENCIA!
!
6 AVISOS ELECTRICOS
!
7 PELIGRO DE RAYOS
!
8 ATENCION:
!
9
!
10
!
11 ATENCION:
!
12 TEMPERATURA REQUERIDA PARA LA OPERACIÓN:
!
13 PARA TODOS LOS PAÍSES:
Emisión RFI EN55022 Clase
radiointerferencias, en cuyo caso, puede requerirse del usuario que tome las medidas que sean convenientes al respecto.
Inmunidad IEC 1000-4-2 (4 kV CD, 8 kV AD)
SEGURIDAD
ADVERTENCIA:
Para evitar un ELECTROCHOQUE, no quite la tapa. No hay ningún componente en el interior al cual puede prestar servicio el usuario. Esta unidad contiene VOLTAJES PELIGROSOS y sólo deberá abrirla un técnico entrenado y calificado. Para evitar la posibilidad de ELECTROCHOQUE desconecte la corriente eléctrica que llega al producto antes de conectar o desconectar los cables LAN.
PELIGRO:
equipos o en LOS CABLES durante TORMENTAS ELECTRICAS.
DE DESCONEXION. PARA DESACTIVAR EL EQUIPO, desconecte el cable de alimentación.
ELECTRICO - EQUIPO DEL TIPO CLASE 1 ESTE EQUIPO TIENE QUE TENER CONEXION A TIERRA. El cable tiene que conectarse a un enchufe a tierra debidamente instalado. Un enchufe que no está correctamente instalado podría ocasionar tensiones peligrosas en las partes metálicas que están expuestas.
EQUIPO CONECTABLE, el tomacorriente se debe instalar cerca del equipo, en un lugar con acceso fácil".
acceso libre al aire ambiental de la sala para su enfriamiento.
diseñado para una temperatura ambiental máxima de 50 grados C.
Eléctricos locales y nacionales.
Este producto cumple con los siguientes estándares.
EN60555-2 (1995) Clase EN60555-3
: en un entorno doméstico, este producto puede causar
IEC 1000-4-3 (1995) (3 V/m) IEC 1000-4-4 (1995) (1.0 kV - (power line);
0.5 kV - (signal line)) IEC 1000-4-6 (1995) (3 Vrms) EN50082-1 (1992) EN61000-4-2 (1995) EN61000-4-4 (1995)
Producto láser Clase 1.
No mirat fijamente el haz.
PELIGRO DE ELECTROCHOQUE
NO REALICE NINGUN TIPO DE TRABAJO O CONEXION en los
EL CABLE DE ALIMENTACION SE USA COMO UN DISPOSITIVO
Las aberturas para ventilación no deberán bloquearse y deberán tener
Monte el producto de acuerdo con los Códigos
A
A
Este producto está
21
Standarder:
!
1
!
2VARNING
!
3
!
4VARNING!
!
5VARNING!
!
6 TILLKÄNNAGIVANDEN BETRÄFFANDE ELEKTRICITETSRISK:
!
7 FARA FÖR BLIXTNEDSLAG
!
8VARNING:
!
9
!
10
!
11 VARNING:
!
12 DRIFTSTEMPERATUR:
!
13 ALLA LÄNDER:
Radiostörning EN55022 Klass
tvinga användaren till att vidtaga erforderliga åtgärder.
Immunitet IEC 1000-4-2 (4 kV CD, 8 kV AD)
SÄKERHET
RISK FÖR ELEKTRISK STÖTFör att undvika ELEKTRISK stöt, ta ej av locket. Det finns inga delar inuti som behöver underhållas. Denna apparat är under HÖGSPÄNNING och får endast öppnas av en utbildad kvalificerad tekniker. För att undvika ELEKTRISK STÖT, koppla ifrån produktens strömanslutning innan LAN­kablarna ansluts eller kopplas ur.
FARA:
FRÅN STRÖMMEN, dra ur nätkabeln.
ELEKTRISKT - TYP KLASS 1 UTRUSTNING DENNA UTRUSTNING MÅSTE VARA JORDAD. Nätkabeln måste vara ansluten till ett ordentligt jordat uttag. Ett felaktigt uttag kan göra att närliggande metalldelar utsätts för högspänning. Apparaten skall anslutas till jordat uttag, när den ansluts till ett nätverk.
UTRUSTNING MED PLUGG. Uttaget skall installeras i utrustningens närhet och vara lättåtkomligt".
rumsluft för avsvalning.
överstigande 50 grader Celsius.
bestämmelser för elektrisk utrustning.
Denna produkt uppfyller följande standarder.
EN60555-2 (1995) Klass EN60555-3
: Denna produkt kan ge upphov till radiostörningar i hemmet, vilket kan
IEC 1000-4-3 (1995) (3 V/m) IEC 1000-4-4 (1995) (1.0 kV - (power line);
0.5 kV - (signal line)) IEC 1000-4-6 (1995) (3 Vrms) EN50082-1 (1992) EN61000-4-2 (1995) EN61000-4-4 (1995)
Laserprodukt av klass 1.
Laserstrålning när enheten är öppen.
ARBETA EJ på utrustningen eller kablarna vid ÅSKVÄDER.
NÄTKABELN ANVÄNDS SOM STRÖMBRYTARE FÖR ATT KOPPLA
Luftventilerna får ej blockeras och måste ha fri tillgång till omgivande
Denna produkt är konstruerad för rumstemperatur ej
Installera produkten i enlighet med lokala och statliga
A
A
22

Appendix B

Technical Support Fax Order

Name _________________________________________________________________ Company______________________________________________________________ Address _______________________________________________________________ City______________________ State/Province_______________________________ Zip/Postal Code ________________ Country_______________________________ Phone______________________________ Fax _______________________________

Incident Summary

Model number of Allied Telesyn product I am using _______________________ Firmware release number of Allied Telesyn product _______________________ Other network software products I am using (e.g., network managers)
______________________________________________________________________ ______________________________________________________________________ ______________________________________________________________________
Brief summary of problem ______________________________________________
______________________________________________________________________ ______________________________________________________________________
Conditions (List the steps that led up to the problem.)______________________
______________________________________________________________________ ______________________________________________________________________ ______________________________________________________________________ ______________________________________________________________________
______________________________________________________________________ Detailed description (Please use separate sheet) Please also fax printouts of relevant files such as batch files and configuration
files. When completed, fax this sheet to the appropriate Allied Telesyn office. Fax numbers can be found on page viii.
23

Appendix C

AT-B15 and AT-B17 Quick Install Guide Feedback

Please tell us what additional information you would like to see discussed in this guide. If there are topics you would like information on that were not covered in this guide, please photocopy this page, answer the questions and fax or mail this form back to Allied Telesyn. The mailing address and fax number are at the bottom of the page. Your comments are valuable when we plan future revisions of this guide.
I found the following the most valuable ___________________________
_______________________________________________________________ _______________________________________________________________ _______________________________________________________________ _______________________________________________________________
I would like the following more developed ________________________
_______________________________________________________________ _______________________________________________________________ _______________________________________________________________ _______________________________________________________________
I would find this guide more useful if _____________________________
_______________________________________________________________ _______________________________________________________________ _______________________________________________________________
Please fax or mail your feedback. Fax to 1-408-736-0100. Or mail to: Allied Telesyn International, Corp. c/o Technical Communications 960 Stewart Drive, Suite B Sunnyvale, CA 94086 USA
PN 613-50113-00 Rev A
25
Loading...