Alliance Laundry Systems PHM1263R User Manual

Washer-Extractor
PHM1263R
Refer to Page 4 for Model Numbers
Programming
Keep These Instructions for Future Reference.
(If this machine changes ownership, this manual must accompany machine.)
www.comlaundry.com
Part No. F8208801R5
NOTE: The WARNING and IMPORTANT
Failure to install, maintain, and/or operate this machine according to the manufacturer's instructions may result in conditions which can produce bodily injury and/or property damage.
W030
WARNING
instructions appearing in this manual are not meant to cover all possible conditions and situations that may occur. It must be understood that common sense, caution, and carefulness are factors which cannot be built into these washer-extractors. These factors MUST BE supplied by the person(s) installing, maintaining, or operating the washer­extractor.
Always contact the distributor, service agent, or the manufacturer about any problems or conditions you do not understand.
F8208801
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
1
Table of
Content s
Model Identification ........................................................................... 4
Preliminary Information.................................................................... 5
About the Control.......................... ..... .................................................. 5
Glossary of Terms................................................................................. 5
Power Failure Recovery ....................................................................... 5
Communications................................................................................... 5
Control Identification......................................................................... 6
Select Cycle Pads.................................................................................. 6
Display Identification ......................................................................... 7
Light Emitting Diodes (LEDs)............................................................. 7
Washer-Extractor Operation ............................................................ 8
Start Up................................................................................................. 8
Door Locking Mode ............................................................................. 8
Stop Mode............................................................................................. 8
Start Mode ............................................................................................ 8
End of Cycle Mode............................................................................... 8
Cycle Sequence..................................................................................... 8
Run Mode ............................................................................................. 8
Signals................................................................................................... 8
Special Features.................................................................................. 9
Programming Control........................................................................... 9
Collecting Audit Information ............................................................... 9
Testing Machine and Control Functions............................................... 9
Rapid Advance Feature......................................................................... 9
Communications Mode......................................................................... 9
Entering the Manual Mode................................................................ 10
How to Enter the Manual Mode ........................................................... 10
Manual Diagnostics.............................................................................. 10
Programming Control........................................................................ 11
What Can Be Programmed? ........................................................ .... ..... 11
Programmable Options Available......................................................... 11
Manual Mode Flowchart....................................................................... 14
Manual Programming Flowchart (1 of 3)............................................. 15
Manual Programming Flowchart (2 of 3)............................................. 16
Manual Programming Flowchart (3 of 3)............................................. 17
Diagnostic Tests Flowchart .................................................................. 18
1. Default Cycle “dCYC” ................................................................ 19
2. Audio Signal “AUd”.................................................................... 20
3. Error Code Programming “Err-”.................................................. 22
4. Cycle Programming “Cy--” ......................................................... 26
5. Number of Balance Retries “bALr”
(Variable Frequency Drives Only)............................................... 30
6. IR Access (On/Off) “IrA”............................................................ 31
7. Fahrenheit/Celsius “t FC”............................................................ 31
8. Hot Water Temperature “FH”...................................................... 32
9. Warm Water Temperature “FHC”............................................... 32
10. Cold Water Temperature “FC”.................................................... 33
11. Cooldown Enable/Temperature “Codn”...................................... 33
12. Production Test Cycle (On/Off) “PtEn” ...................................... 34
13. Manual Rapid Advance (On/Off) “rAEn”................................... 34
14. No Cycle Time Display “nCtd”................................................... 35
15. Programmable Cycle Time Display “PCtd” ................................ 35
© Copyright 2010, Alliance Laundry Systems LLC All rights reserved. No part of the contents of this book may be reproduced or transmitted in any form or by any
means without the expressed written consent of the publisher.
2
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
F8208801
16. Slow Drain Detection Adjust “SdAd” ......................................... 36
17. Set Real-Time Clock “rtC-”’ ....................................................... 37
18. Manual Diagnostics (On/Off) “dAEn” ........................................ 38
19. Low Water Level “FLo”.............................................................. 38
20. Medium Water Level “FnEd”........................................ ..... ......... 39
21. High Water Level “FHI”.............................................................. 39
22. Temperature Controlled Fill Enable/Disable “tCF” .................... 40
23. Auto-Water Leak Detection “ALd”............................................. 41
Collecting Audit Information ............................................................ 42
Manual Reset....................................................................................... 43
Testing Machine and
Electronic Control Functions............................................................. 44
Diagnostic Test Descriptions................................................................ 46
Production Test Cycle.................................................... ....................... 48
Error Codes......................................................................................... 51
Rapid Advance Feature...................................................................... 53
Communications Mode ...................................................................... 54
Infra-red Communications.................................................................... 54
Default Cycles...................................................................................... 55
F8208801
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
3
Model Identification
Information in this manual is applicable to these washer-extractor models:
UWL035K12 UWN080K1M UWL035K1L UWN080K1V UWL035K1M UWN100K1M UWL060K12 UWN100K1V UWL060K1L UWN125K1M UWL060K1M UWN125K1V UWL080K1M UWU035K12 UWL100K1M UWU035K1L UWL125K1M UWU035K1M UWN035K12 UWU060K12 UWN035K1L UWU060K1L UWN035K1M UWU060K1M UWN060K12 UWU080K1M UWN060K1L UWU100K1M UWN060K1M UWU125K1M UWN060K1V
4
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
F8208801
Preliminary Information
About the Control
This control is an advanced, programmable computer that lets the owner control most machine features by pressing a sequence of keypads. Refer to Figure 1.
The control allows the owner to program custom cycles, retrieve audit information, run diagnostic tests, and other programmable features. Refer to Programming Control for a list of features. Washer- extractors shipped from the factory have a default cycle of Cycle #5 built in. However, the owner can change the default cycle, or any cycle, as needs permit.
IMPORTANT: In the event of a power failure, the control will not have to be reprogrammed. It is designed with a memory system that will remember how it was programmed until the electrical power is restored.
IMPORTANT: It is extremely important that the washer-extractor has a good gro und connection and that all mechanical and electrical connections to the control are made before applying power to or operating the washer-extractor.
Glossary of Terms
The following are a few terms and abbreviations to learn. These are referred to throughout the instructions.
Power Failure Recovery
If a cycle is in progress and the power fails for less than five seconds, the cycle status is saved in memory. When the power recovers, the washer-extractor will resume into the previously active cycle.
If the length of the power failure is greater than five seconds, the control will end the cycle and the display will revert back to Start Mode.
Communications
The control may be programmed manually or by infra­red communication with an external device.
Infra-red Communications
An external device, such as a PDA, allows the owner to program and retrieve information from the control without touching the keypad. An external device greatly expands the programming options available to the owner. However, it is not required to program and operate the washer-extractor. The operation of an external device and the advanced features available are covered separately in the instructions included with the external device software. Contact Alliance Laundry Systems for a list of approved PDAs and other external devices.
Display – This term refers to the window area of the
control that displays words and values.
LED (Light Emitting Diode) – This term refers to the
lights next to the keypads and status words of the control.
F8208801
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
5
Control Identification
PHM1263R
1
2
4
5
3
7
6
Select Cycle Pads (Refer to Figure 1)
SELECT CYCLE pads are used to select the specific washer cycle. These pads are numbered 0-9 and allow the user to select a cycle other than the default cycle (#5). The SELECT CYCLE keypads are not active after a cycle has been started. Pressing the flashing START pad will confirm the selection and the cycle will begin.
The SELECT CYCLE pads are used in va rious combinations for programming cycles, retrieving audit information, running diagnostic tests, and other operations. These instructions cover the manual programming and data retrieval options.
1 SELECT CYCLE pads 2 Display 3 Four 7-Segment Digits 4 STOP UNLOCK pad 5 START pad 6 LED Light 7 LED Status Lights
6
Figure 1
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
PHM1263R
F8208801
Display Identification
Light Emitting Diodes (LEDs) (Refer to Figure 1)
LIGHT EMITTING DIODES (LEDs) are used to indicate the chosen cycle, cycle status, when the bleach compartment is dispensing, and door lock information. See below for information on each LED.
WASH LED
WASH LED is lit at the beginning of a wash portion of the cycle and will remain lit until the wash is complete.
RINSE LED
RINSE LED is lit at the beginning of a rinse portion of the cycle and will remain lit until the rinse is complete.
SPIN LED
SPIN LED is lit during the Final Spin portion of the cycle.
DOOR LED
DOOR LED is lit whenever the door is locked.
Four 7-Segment Digits
The 7-SEGMENT DIGITS are used to display the time remaining in a cycle, error messages and descriptive codes. During diagnostic testing or manual programming of the control, these digits will display descriptive codes and values (as described in Entering the Manual Mode).
F8208801
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
7
Washer-Extractor Operation
Start Up
When power is applied to the washer-extractor, the control will display its software version as “S XX” (“XX” is the version number) for one second. If the control was not powered down during a running cycle, it will enter Start Mode.
Door Locking Mode
The control enters this mode after the START (enter) keypad is pressed in Start Mode. The control stays in Door Locking Mode until it confirms the door is closed and locked.
Stop Mode
The control enters this mode if the user stops the cycle by pressing the STOP keypad. If control does not detect water or cylinder rotation it will enter End Of Cycle mode.
Start Mode
The control enters this mode when machine is ready for operation. The display will show “CYxx” where “xx” is the cycle number.
After pressing the START keypad, with the door closed and locked, the cycle will begin. The cycle cannot be changed once the cycle has st arte d.
Run Mode
The control enters this mode when a cycle is running. The time remaining appears in the display , the status LED’s are lit and the loading door is locked.
Signals
There are two options when a signal can be used during the washer operation. These two options are listed below:
1. End of Cycle Signal
By default, this signal is turned off. If turned on, the signal sounds for three (3) seconds at the end of a cycle.
2. Signal On Keypad Depression
By default, this signal is turned on and sounds for a quarter of a second each time a keypad is pressed.
NOTE: Refer to Programming Control to program signal options.
End of Cycle Mode
When a cycle is complete, the control will display “00” and will prompt for door unlock by flashing STOP/ UNLOCK LED until the washer door is unlocked and opened. When this event occurs, the display will revert back to Start Mode.
Cycle Sequence
Upon the start of a cycle, the control will display the total cycle time. The appropriate LEDs will light while the machine passes through different cycle steps. The user will not be able to change cycles or water temperature.
8
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
F8208801
Special Features
Programming Control
The control allows the washer-extractor owner to program the control with the use of the keypad. Cycle options may be programmed, audit information may be viewed and diagnostic tests may be run by pressing combinations of the select cycle keypads.
For details on programming select cycle options, refer to Programming Control.
Collecting Audit Information
The control will store audit information in its memory that can be retrieved by pressing various combinations of Select Cycle keyp a d s . The control will record total machine cycles.
For more information on the audit features, refer to Collecting Audit Information.
NOTE: Additional audit information is retrievable with an external device, using infra-red communications. Refer to the appropriate instruction manual.
Testing Machine and Control Functions
Rapid Advance Feature
This feature allows the user to quickly advance through active cycles. This feature is useful when tests must be performed immediately on a washer-extractor currently in an active cycle. In this case, the user can quickly advance through the cycles to shakeout. At this point, the user can perform the required tests and then return the washer-extractor to the point it was interrupted.
For detailed information on using the Rapid Advance feature, refer to Rapid Advance Feature.
Communications Mode
This feature allows the control to communicate with an external device using infra-red communications. This allows the control to be programmed and have its data read without using the keypad.
For more detailed information on using the Communications Mode feature, refer to Communications Mode.
Special diagnostic features built into the control allow the owner to run specific diagnostic tests. By opening and closing the access panel and then pressing various sequences of Select Cycle keypads, the owner may retrieve or perform the following tests:
Front End Control Software Version Number
Output Board Control Software Version Number
Output Board Water Level Sensor Trim Value
Access Panel Opening Test
Door Switch Input Test
Door Lock Input Test
Show Fill Time Test
Show Drain Time Test
Temperature Sensor Display Test
Start Pulse Test
VFD Balance Input Test
24 VAC Switch Input Test
VFD Drive Fault Input Test
Frame Balance Switch Input Test
VFD Balance Weight Test
Water Purge Test
Water Leak Detection test
For detailed information on running diagnostic tests, refer to Testing Machine and Control Functions.
F8208801
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
9
Entering the Manual Mode
>
<
For programming, testing, and retrieving information from the control, it is often necessary to enter the Manual Mode by following the six simple steps below .
How to Enter the Manual Mode
1. If the washer is in an active cycle, rapid advance
through the cycle. Refer to the Rapid Advance Feature.
2. Press and hold the #4 keypad and the #1 keypad at the same time.
3. The display will show “rAPd”.
4. Press the #3 ( ) keypad or the #6 ( ) keypad to scroll through the options until the desired option appears in the display.
5. Press the START (enter) keypad.
Manual Mode is broken into three groups: Manual Programming, Manual Rapid Advance and Manual Diagnostics. Manual Programming can only be turned on or off with an external device. Refer to the appropriate instruc tion m anual. Manual Rapid Advance and Ma nua l D iag no sti cs can be turned on and off usi ng an external device or by manual p rogramming (refer to 13 and 15 of Programming Control).
Manual Programming
Manual Programming (Prog) Manual Read Audit (AUdt) Manual Reset (rSEt)
Manual Rapid Advance
Rapid Advance (rAPd)
Manual Diagnostics
Manual Diagnostic Tests (dIAg) If a group is turned off, the display will change from
the selected feature to “OFF” when the START pad is pressed and an audio signal will sound for one second. The display will then return to the selected feature. The features in the group cannot be entered.
By default, all groups are turned “ON”. The manual features available in each group are as
follows (the menu displayed on the display in this mode is in parentheses).
10
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
F8208801
Programming Control
What Can Be Programmed?
Each description includes instructions on when and why the option might be used and, more importantly,
This feature allows the owner to program cycle information and other features by using the keypads. The control must have the Manual Programming Mode enabled, which is the factory default. This mode can only be turned “OFF” and “ON” by using an external device. Refer to this section when programming the control.
This section offers a detailed description of all available programmable options.
how to program the option. For more advanced users, a quick reference list (refer
to Table 1) of the options available through the programming mode is available. Programming flowcharts (refer to Figures Figure 2-Figure 6) are located on the following pages.
NOTE: The letters and numbers in the Option Display column of the Programmable Options List are what will be shown in the display when that option is selected.
Programmable Options Available
Option
Number
1“dCYC” Default Cycle Cy05”* Cy01”-“Cy30”* 2“AUd” Audio Signal 29”* 0”-“31”* 3“Err-” Errors ——
a. b. c. d. e. f. g.
h.
4“Cy--” Cycle Programming Refer to Operation Manual for default cycle
a.
b.
Option
Display
E FL Fill Errors on”“on”/“oFF”
E dr Drain Error on”“on”/“oFF”E Ub Unbalance Error Display on”“on”/“oFF”E oP Open Therm ister Error Display on”“on”/“oFF”
E SH Shorted Thermistor Error Display on”“on”/“oFF”
E Ht Heat Error Display (Heater only) on”“on”/“oFF”
LEr- Water Leak Detection Error
1.
2.
3.
1.
2.
1.
LEr1 1. W ater Leak Detection During a Machine Cycle
(On/Off)
LEr2 2. Water Leak Detection Day of Week Enable 127”* 0”-“127”*
LEr3”*** 3. Number of Cycles Between Water Leak
Detection During a Machine Cycle
ESd” Slow Drain Detection oFF”“on”/“oFF”
AgIt Cycle Agitate ——
tyPE Agitate Type ** 1”-“4”*
ASPd Agitate Speed (VFD only) ** Lo”/“rEg”*
Segx
(1-8)
SgEn Segment Enable/Disable ** on”/“oFF
Cycle Segment Programming ——
Description Default
Value
oFF”“on”/“oFF”
0”“0”-“127”
Table 1 (continued)
Value Range
information
F8208801
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
11
Programming Control
Table 1 (continued)
Option
Number
c.
Option
Display
Description Default
Value
Value Range
FILL Fill Step ——
1.
FLEn Fill Step Enable/Disable ** on”/“oFF
2.
FLEU F ill Level ** HI”/“nEd”/“Lo” or 1-30
3.
tEnP Fill Temperature ** CoLd”/“Uarn”/“Hot”or
35°F-194°F/2°C-90°C
d.
SUPL Supply Step ——
1.
SUEn Supply Step Enable/Disable ** on”/“oFF
2.
dISP Dispenser Options ** Display will show “Sx”
3.
4.
5.
6.
7.
S1 Supply #1 ** on”/“oFF” “S2 Supply #2 ** “on”/“oFF” “S3 Supply #3 ** on”/“oFF” “S4 Supply #4 ** on”/“oFF
SdUr Supply Duration ** Press START keypad to access
options
8.
9.
e.
1.
2.
SEC Seconds ** 0-59
nIn Minutes ** 0-9
AgSt Agitate Step
——
AgEn Agitate Step Enable/Disable ** on”/“oFF
AdUr Agitate Duratio n (in minutes) ** 1-30 for agitate types 1 or 2;
1-180 for agitate types 3 or 4
3.
HEAt Heat in Agitate (if heater is present) oFF” (Rinse)
oFF”/“1”/“2”**
2” (Wash)
f. g.
drAn Drain Step —“on”/“oFFSPIn Spin Stop ——
1.
SPEn” Extract Step Enable/Disable ** on”/“oFF”
2.
SSEC Extract Seconds ** 0-59
3.
SnIn Extract Minutes ** Intermediate Extract:
Min. Step Time = 30 seconds, Max. Step Time = 3:59 minutes
Final Extract: Min. Step Time = 30 seconds, Max. Step Time = 9:59 minutes
4.
SSPd Extract Speed (VFD only) ** “1”-“3”*
h.
Cnin”*** Cycle Time in Minutes (If PCtd is enabled) 00-255 minutes 5“bALr” Number of Balance Retries (VFD only) 31-7 6“IrA” IR Access (On/Off) on”“on”/“oFF 7“t FC” Fahrenheit/Celsius FAHr
(Fahrenheit)
FAHr” (Fahrenheit)/“CEL (Celsius)
8“FH” Hot Water Temperature 140°F (60°C) 35°F-194°F/2°C-90°C 9“FHC” Warm Water Temperature 100°F (38°C) 35°F-194°F/2°C-90°C 10 FC Cold Water Temperature 35°F (2°C) 35°F-194°F/2°C-90°C
Table 1 (continued)
12
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
F8208801
Programming Control
Table 1 (continued)
Option
Number
Option
Display
Description Default
Value
Value Range
11 Codn Cooldown Enable/Temperature oFF”“oFF” or 50°F-160°F/10°C-71°C 12 PtEn Production Test Cycle (On/Off) on”“on”/“oFF 13 rAEn Manual Rap id Ad vance (On/Off) on”“on”/“oFF 14 nCtd No Cycle Time Display oFF”“on”/“oFF 15 PCtd”*** Programmable Cycle Time Display 0 0 = Disabled / 1 = Enabled 16 SdAd Slow Drain Detection Adjust 0 0-255 seconds 17 rtC-” Real Time Clock ——
a. b. c. d. e. f. g.
18 dAEn Manual Diagnostics (On/Off) on”“
rtC1 Set Real Time Clock Minutes 00-59 “rtC2 Set Real Time Clock Hours 00-23 “rtC3 Set Real Time Clock Day 001” (Sunday)-“007” (Saturday) “rtC4 Set Real Time Clock Date 1-31 “rtC5 Set Real Time Clock Month 1-12 “rtC6 Set Real Time Clock Year 00 (2000)-99 “rtC7 Daylight Savings Option on”“on”/“oFF”
on”/“oFF
19 FLo Low Water Level 31-10 20 FnEd Medium Water Level 15 11-20 21 FHI High Water Level 27 21-30 22 tCF Temperature Controlled Fill oFF”“on”/“oFF 23 ALd Auto-Water Leak Detection ——
a. b. c.
ALd1 Auto-Water Leak Detection (On/Off and cycles) oFF”“oFF”/0-127 (Cycles)ALd2 Auto-Water Leak Detection Hour 0 0-23 “ALd3 Auto-Water Leak Detection Day of Week 127”* “0”-“127”*
*Refer to programming section for value definition. **Refer to the Operation Manual for default cycle setting information. ***Option not available on Software Version 1.
Table 1
F8208801
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
13
Programming Control
Enter Manual Mode.
Press and hold both #4 keypad and
#1 keypad at the same time.
“rAPd” - Quickly advance through active
cycles.
1. Press START (enter) keypad to begin Rapid Advance cycle and advance through cycle
steps.
“AUdt” - Retrieve audit information for
machine.
1. Press START (enter) keypad.
“CyC” - Total number of machine cycles:
1. Press START (enter) once to read audit.
“rSEt” - Reset the control’s programming data
to factory default.
1. Press START (enter) keypad.
“Prog” - Program cycle information and other
features into the control.
1. Refer to the Manual Programming flowchart.
“dIAg” - Run diagnostic tests on machine
operations.
1. Press START (enter) keypad. Refer to Diagnostic Tests flowchart.
“rCyC” * - Total number of rapid advance cycles:
1. Press START (enter) once to read audit.
* Option available on software version 2 only.
PHM140
Manual Mode Flowchart
PHM1401R
14
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Figure 2
F8208801
Manual Programming Flowchart (1 of 3)
PHM128
“AUd” - Program when the signal will sound.
“Err-” - Turn on/off certain errors in control.
“E FL” - Fill Error
“E dr” - Drain Error
“E Ub” - Unbalance Error (VFD only)
“E Sd” - Slow Drain Detection
“FILL” - Program fill step options
“LEr-” - Leak Detection
“E oP” - Open Thermistor Error
(temp sensor only)
“E SH” - Shorted Thermistor Error
(temp sensor only)
“LEr1” - Water Leak Detection During
a Machine Cycle
“LEr2” - Water Leak Detection - Day
of Week
“dCYC” - Set the default cycle and
temperature.
“Cy--” - Program aspects for the various
steps in each type of cycle. There are (30)
cycles available for programming.
(continued)
“SEg1” - Program options for each
segment. There are (8) segments
available for programming
“SgEn” - Segment Enabled/Disabled:
“on” = Enabled
“oFF” = Disabled
“tyPE” - Agitation Type:
1 = 18/3/18
2 = 10/20/10
3 = 3/27/3 4 = 4/56/4
“ASPd” - Agitation Speed (VFD only):
“Lo” = Reduced Speed
“rEg” = Normal Speed
“AgIt” - Program the cycles agitation
action and speed
(continued)
““FLEn” - Fill Step Enable/Disable:
“on” = Enabled
“oFF” = Disabled
“FLEU” - Fill Level:
“HI” = High Level
“nEd” = Medium Level
“Lo” = Low Level
“1-30” = Fill Level
“tEnP” - Fill Temperature:
“CoLd” = Cold
“UArn” = Warm
“Hot” = Hot
(35˚F - 194˚F [2˚C - 90˚C])
“E Ht” - Heat Error (heater only)
Programming Control
F8208801
Figure 3
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
PHM1280R
15
Programming Control
Manual Programming Flowchart (2 of 3)
(continued) (continued)
“SUPL” - Program supply step options
“AgSt” - Program agitate step options
“SUEn” - Supply Step Enable/Disable:
Press START (enter) to access options
Press START (enter) to access options
“1” - “30” (for agitation types 1 or 2) or
“on” = Enabled
“oFF” = Disabled
“dISP” Dispenser Options:
“SdUr” Supply Duration:
“AgEn” - Agitate Step
Enabled/Disabled:
“on” = Enabled
“oFF” = Disabled
“AdUr” - Agitate Duration (min):
“1” - “180” for agitation types 3 or 4
“HEAt” - Heat in Agitate
(heat present only):
“oFF” = Disabled
“1” = To Target
“2” = Maintain
“S1” -
Supply #1:
“on” = Enabled
“oFF” = Disabled
“S2” -
Supply #2:
“on” = Enabled
“oFF” = Disabled
“S3” -
Supply #3:
“on” = Enabled
“oFF” = Disabled
“S4” - Supply #4:
“on” = Enabled
“oFF” = Disabled
“SEC” - Seconds:
“0” - “59”
“nIn” - Minutes:
“0” - “9”
“drAn” - Enable/disable drain step
“SPIn” - Program extract step options
(continued)
“Cnin” * - Programmable
Cycle Time Display
in Minutes: "0" - "255"
* Option available on software version 2 only.
“oFF” = Disabled
“SPEn” - Extract Step
Enabled/Disabled:
“on” = Enabled
“oFF” = Disabled
“SSEC” - Extract Seconds:
“SnIn” - Extract Minutes:
“30” - “3.59”: Intermediate Step
“30” - “9:59”: Final Step
“SSPd” Extract Speed (VFD only):
1 = Very Low Speed (60g) 2 = Low Speed (L - Speed = 100g; M - Speed = 120g) 3 = Medium Speed (L - Speed = 100g; M - Speed = 180g)
Figure 4
Drain Step:
“on” = Enabled
“0” - “59”
PHM1402R
PHM1402R
16
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
F8208801
Manual Programming Flowchart (3 of 3)
(continued)
“bALr” (VFD only) - Program the number
of times control will retry balancing the
load before moving to extract step: 1-7.
“IrA” - Enable/disable the ability to read
the control by an external device:
“on” = Enabled
“off” = Disabled.
“t FC” (Temp Sensor only) - Set
temperature shown in Fahrenheit or Celsius.
“FH” (Temp Sensor only) - Set
the temperature of the hot water:
35°F - 194°F / 2°C - 90°C.
“FHC” (Temp Sensor only) - Set the
temperature of the warm water:
35°F - 194°F / 2°C - 90°C.
“FC” (Temp Sensor only) - Set the
temperature of the cold water:
35°F - 194°F / 2°C - 90°C.
“Codn” (Temp Sensor only) - Enable/disable
the cool down water temperature option:
“off” or 50°F - 160°F / 10°C - 71°C.
“PtEn” - Enable/disable access to the
production test cycle:
“on” = Enabled
“off” = Disabled.
“rAEn” - Enable/disable the rapid advance
“nCtd” - Enable/disable whether the cycle
“PCtd” * - When enabled, the control
displays the programmed time during
“SdAd” - Enable/disable slow drain
increase/decrease the time before a slow
“rtC-” - set the control’s internal clock.
“dAEn” - Enable/disable the manual
“FLo” - Program the low water level
during fill and tumble of all cycles:
“FnEd” - Program the medium water level
during fill and tumble of all cycles:
“FHI” - Program the high water level during
“tCF” (Temp Sensor only) - Enable/disable a
“ALd-” - Set the time and frequency that the control automatically checks the water level.
* Option available on software version 2 only.
feature:
“on” = Enabled
“off” = Disabled.
time will appear in display:
“on” = Enabled
“off” = Disabled.
a machine cycle:
“0” = Disabled “1” = Enabled
detection. When enabled can
drain error will occur:
0 - 255 seconds
diagnostics option:
“on” = Enabled
“off” = Disabled.
“1” - “10”
“11” - “20”
fill and tumble of all cycles:
“21” - “30”
temperature controlled fill:
“on” = Enabled
“off” = Disabled.
Temperature:
“CEL” = Celsius
“FAHr” = Fahrenheit
“rtC1” - Programs minutes:
“0” - “59”
“rtC2” - Programs Hours:
“0” - “23”
“rtC3” - Programs Day of Week:
“1” - “7”
“rtC4” - Programs Date of Month:
“1” - “31”
“rtC5” - Programs Month:
“1” - “12”
“rtC6” - Programs Year:
“0” - “99”
“rtC7” - Programs Daylight Saving:
“on” = Enabled
“oFF” = Disabled
“ALd1” - Auto-Water Leak Detection:
“on”, then “0” - “127”
“oFF”
“ALd2”” - Auto-Water Leak Detection
“ALd3” - Auto-Water Leak Detection
Hour:
“0” - “23”
Day of Week:
“0” - “127”
Programming Control
PHM1400R
F8208801
Figure 5
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
PHM1400R
17
Loading...
+ 43 hidden pages