Alliance CP080PMN2 Installation Manual

Washer-Extractors
Pocket Hardmount Variable-Speed
PS40 Control
Refer to Page 4 for Model Identification
Installation/Operation Supplement
Keep These Instructions for Future Reference.
(If this machine changes ownership, this manual must accompany machine.)
www.comlaundry.com
PHM1397C
PHM1397C
March 2008
Installation/Operation Supplement
Table of
Contents
Safety Information.............................................................................. 2
Explanation of Safety Messages........................................................... 2
Important Safety Instructions ............................................................... 2
Model Identification ............................................................................. 4
Specifications and Dimensions........................................................... 5
High Speed Models............................................................................... 5
Medium Speed Models......................................................................... 8
Machine Dimensions ............................................................................ 10
40 Pound Models ............................................................................. 11
60 Pound Models ............................................................................. 12
80 Pound Models ............................................................................. 13
100 Pound Models ........................................................................... 14
125 Pound Models ........................................................................... 15
140 Pound Models ........................................................................... 16
175 Pound Models ........................................................................... 17
Front and Rear Features........................................................................ 18
Floor Load Data.................................................................................... 19
Installation Instructions ........................................................................ 21
Surface ............................................................................................. 21
Anchors ............................................................................................ 21
Mounting.......................................................................................... 21
Mounting Bolt Installation Requirements ............................................ 22
Location ........................................................................................... 22
Clearances ........................................................................................ 22
40 Pound Models ............................................................................. 23
60, 80 and 100 Pound Models.......................................................... 25
125, 140 and 175 Pound Models...................................................... 27
Provisions for 50 Hz Installations.................................................... 29
Operation............................................................................................. 31
General Operation Instructions............................................................. 32
Operating PS40 Control........................................................................ 32
Disposal of Unit................................................................................... 34
© Copyright 2008, Alliance Laundry Systems LLC All rights reserved. No part of the contents of this book may be reproduced or transmitted in any form or by any
means without the expressed written consent of the publisher.
C002882
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
1
Installation/Operation Supplement
Safety Information
Explanation of Safety Messages
Precautionary statements (“DANGER,” “WARNING,” and “CAUTION”), followed by specific instructions, are found in this manual and on machine decals. These precautions are intended for the personal safety of the operator, user, servicer, and those maintaining the machine.
DANGER
DANGER indicates the presence of a hazard that will cause severe personal injury, death, or substantial property damage if the danger is ignored.
WARNING
WARNING indicates the presence of a hazard that can cause severe personal injury, death, or substantial property damage if the warning is ignored.
Important Safety Instructions
WARNING
To reduce the risk of fire, electric shock, serious injury or death to persons when using your washer, follow these basic precautions:
W023
1. Read all instructions before using the washer.
2. Refer to the GROUNDING INSTRUCTIONS in the INSTALLATION manual for the proper grounding of the washer.
3. Do not wash textiles that have been previously cleaned in, washed in, soaked in, or spotted with gasoline, kerosene, waxes, cooking oils, dry­cleaning solvents, or other flammable or explosive substances as they give off vapors that could ignite or explode.
4. Do not add gasoline, dry-cleaning solvents, or other flammable or explosive substances to the wash water. These substances give off vapors that could ignite or explode.
CAUTION
CAUTION indicates the presence of a hazard that will or can cause minor personal injury or property damage if the caution is ignored.
Additional precautionary statements (“IMPORTANT” and “NOTE”) are followed by specific instructions.
IMPORTANT: The word “IMPORTANT” is used to inform the reader of specific procedures where minor machine damage will occur if the procedure is not followed.
NOTE: The word “NOTE” is used to communicate installation, operation, maintenance or servicing information that is important but not hazard related.
5. Under certain conditions, hydrogen gas may be produced in a hot water system that has not been used for two weeks or more. HYDROGEN GAS IS EXPLOSIVE. If the hot water system has not been used for such a period, before using a washing machine or combination washer-dryer, turn on all hot water faucets and let the water flow from each for several minutes. This will release any accumulated hydrogen gas. The gas is flammable, do not smoke or use an open flame during this time.
6. Do not allow children to play on or in the washer. Close supervision of children is necessary when the washer is used near children. This is a safety rule for all appliances.
7. Before the washer is removed from service or discarded, remove the door to the washing compartment.
8. Do not reach into the washer if the wash drum is moving.
2
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT C002882
Installation/Operation Supplement
9. Do not install or store the washer where it will be exposed to water and/or weather.
10. Do not tamper with the controls.
11. Do not repair or replace any part of the washer, or attempt any servicing unless specifically recommended in the user-maintenance instructions or in published user-repair instructions that the user understands and has the skills to carry out.
12. To reduce the risk of an electric shock or fire, DO NOT use an extension cord or an adapter to connect the washer to the electrical power source.
13. Use washer only for its intended purpose, washing textiles.
14. Never wash machine parts or automotive parts in the machine. This could result in serious damage to the basket.
15. ALWAYS disconnect the washer from electrical supply before attempting any service. Disconnect the power cord by grasping the plug, not the cord.
16. Install the washer according to the INSTALLATION INSTRUCTIONS. All connections for water, drain, electrical power and grounding must comply with local codes and be made by licensed personnel when required.
17. To reduce the risk of fire, textiles which have traces of any flammable substances such as vegetable oil, cooking oil, machine oil, flammable chemicals, thinner, etc., or anything containing wax or chemicals such as in mops and cleaning cloths, must not be put into the washer. These flammable substances may cause the fabric to catch on fire by itself.
18. Do not use fabric softeners or products to eliminate static unless recommended by the manufacturer of the fabric softener or product.
20. Be sure water connections have a shut-off valve and that fill hose connections are tight. CLOSE the shut-off valves at the end of each wash day.
21. Loading door MUST BE CLOSED any time the washer is to fill, tumble or spin. DO NOT bypass the loading door switch by permitting the washer to operate with the loading door open.
22. Always read and follow manufacturer’s instructions on packages of laundry and cleaning aids. Heed all warnings or precautions. To reduce the risk of poisoning or chemical burns, keep them out of the reach of children at all times (preferably in a locked cabinet).
23. Always follow the fabric care instructions supplied by the textile manufacturer.
24. Never operate the washer with any guards and/or panels removed.
25. DO NOT operate the washer with missing or broken parts.
26. DO NOT bypass any safety devices.
27. Failure to install, maintain, and/or operate this washer according to the manufacturer’s instructions may result in conditions which can produce bodily injury and/or property damage.
NOTE: The WARNINGS and IMPORTANT SAFETY INSTRUCTIONS appearing in this manual are not meant to cover all possible conditions and situations that may occur. Common sense, caution and care must be exercised when installing, maintaining, or operating the washer.
Any problems or conditions not understood should be reported to the dealer, distributor, service agent or the manufacturer.
19. Keep washer in good condition. Bumping or dropping the washer can damage safety features. If this occurs, have washer checked by a qualified service person.
C002882
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
3
Installation/Operation Supplement
Model Identification
Information in this manual is applicable to these models:
Medium Speed High Speed
IP040PMQ1 IP040PMX1 IPH40M IPH180
IP060PMQ1 IP060PMX1 IPH60M IPH270 JP060PMQ1
IP080PMQ1 IPH80M IPH370
IP100PMQ1 IPH100M IPH460 JP100PMQ1
IP140PMQ1 IPH140M IPH640 JP140PMQ1
40
Pound
60
Pound
80
Pound
100
Pound
125
Pound
140
Pound
175
Pound
CP040PMN1 CP040PMQ1 CP040PMX1 CPC40M IP040PMN1
CP060PMN1 CP060PMQ1 CP060PMX1 CPC60M IP060PMN1
CP080PMN1 CP080PMQ1 CPC80M IP080PMN1
CP100PMN1 CP100PMQ1 CPC100M IP100PMN1
Not Applicable
CP140PMN1 CP140PMQ1 CPC140M IP140PMN1
Not Applicable
CP040PHN1 CP040PHQ1 CP040PHX1 CPC40H IP040PHN1
CP060PHN1 CP060PHQ1 CP060PHX1 CPC60H IP060PHN1
CP080PHN1 CP080PHQ1 CPC80H IP080PHN1
CP100PHN1 CP100PHQ1 CPC100H IP100PHN1
CP125PHN1 CP125PHQ1 CPC125H IP125PHN1
CP140PHN1 CP140PHQ1 CPC140H IP140PHN1
CP175PHN1 CPC175H IP175PHN1
IP040PHQ1 IP040PHX1 IPH40H JP040PHN1 JP040PHQ1
IP060PHQ1 IP060PHX1 IPH60H JP060PHN1 JP060PHQ1
IP080PHQ1 IPH80H JP080PHN1 JP080PHQ1
IP100PHQ1 IPH100H JP100PHN1 JP100PHQ1
IP125PHQ1 IPH125H IPH570 JP125PHN1
IP140PHQ1 IPH140H JP140PHN1 JP140PHQ1
IPH175H IPH790
4
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
C002882
Installation/Operation Supplement
Specifications and Dimensions
High Speed Models
Models
Specifications 40H 60H 80H 100H 125H 140H 175H
Overall Dimensions
Overall Width, mm (in.)
Overall Height, mm (in.)
Overall Depth, mm (in.)
Weight and Shipping Information
Net Weight, kg (lbs.)
Domestic Shipping Wei ght, kg (lbs.)
Domestic Shipping Vo lu m e, m3 (ft.3)
813
(32)
1448
(57)
1158
(45.6)
768.2
(1690)
804.5
(1770)
1.78 (63)
876
(34.5)
1590
(62.6)
1213
(47.8)
815.9
(1795)
861.3
(1895)
2.18
(76.9)
1080
(42.5)
1778
(70)
1306
(51.4)
875.5
(1926)
920.9
(2026)
3.11
(110)
1080
(42.5)
1778
(70)
1433
(56.4)
985
(2167)
1030.5 (2267)
3.45
(122)
1430
(56.3)
1958
(77.1)
1425
(56.1)
1247
(2749)
1292
(2849)
4.53
(160)
1430
(56.3)
1958
(77.1)
1502
(59.1)
1375.9 (3027)
1421.3 (3127)
4.73
(167)
1430
(56.3)
1958
(77.1)
1626
(64)
1489.5 (3277)
1535
(3377)
5.16
(179)
Wash Cylinder Information
Cylinder Diameter, mm (in.)
Cylinder Depth, mm (in.)
Cylinder Volume, l (ft.3)
Perforation Size, mm (in.)
Cylinder Capacity 1:10 Fill Ratio, kg (lbs.)
686
(27)
483
(19)
178.3 (6.3)
4.83
(0.19)
17.8
(39.3)
787
(31)
559
(22)
271.7 (9.6)
4.83
(0.19)
27.2 (60)
Door Opening Information
Door Opening Size, mm (in.)
Height of Door Bottom Above Floor, mm (in.)
381
(15)
648
(25.5)
432
(17)
730
(28.8)
Drain System
Overflow Size, mm (in.)
Drain Outlet Size, mm (in.)
Number of Drain Outlets, (std/opt)
All specifications are subject to change without notification.
38.1
(1.5)
76.2 (3)
38.1
(1.5)
76.2 (3)
1/2 1/2 1/2 1/2 1/2 1/2 1/2
940
(37)
533
(21)
370.7
(13.1)
4.83
(0.19)
37
(81.6)
508
(20)
752
(29.6)
38.1
(1.5)
76.2 (3)
Table 1 (continued)
940
(37)
660
(26)
458.5
(16.2)
4.83
(0.19)
45.9
(101)
508
(20)
765
(30.1)
38.1
(1.5)
76.2 (3)
1092
(43)
610
(24)
569.2
(20.1)
4.83
(0.19)
57
(125)
622
(24.5)
837
(34)
76.2 (3)
76.2 (3)
1092
(43)
686
(27)
642.4
(22.7)
4.83
(0.19)
64.3
(141.7)
622
(24.5)
871
(34.3)
76.2 (3)
76.2 (3)
1092
(43)
813
(32)
759.9
(26.8)
4.83
(0.19)
79.5
(175)
622
(24.5)
884
(34.8)
76.2 (3)
76.2 (3)
C002882
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
5
Installation/Operation Supplement
Table 1 (continued)
Models
Specifications 40H 60H 80H 100H 125H 140H 175H
Water Inlet
Connection Size
Number of Inlets, (std/opt)
3/4 NPT 3/4 NPT 3/4 NPT 3/4 NPT 3/4 NPT 1-1/4 NPT 1-1/4 NPT
2/3 2/3 2/3 2/3 2/3 2/3 2/3
Chemical Supply System
Number of Dry Chemical Compartments, (std/opt)
Number of Liquid Supply Connections, (std/opt)
1/5 1/5 1/5 1/5 1/5 1/5 1/5
6/12 6/12 6/12 6/12 6/12 6/12 6/12
Cylinder Speeds/Centrifugal Force Data
Low Wash Speed, G-Force (RPM)
Wash Speed, G-Force (RPM)
Balance Speed, G-Force (RPM)
Low Extract Speed, G-Force (RPM)
Medium Extract Speed, G-Force (RPM)
High Extract Speed, G-Force (RPM)
Maximum SmartSpin Speed, G-Force (RPM)
0.014 (6)
0.8
(46)
2
(72)
100
(511)
140
(605)
230
(775)
300
(885)
0.016 (6)
0.8
(43)
2
(67)
100
(477)
140
(564)
230
(723)
300
(826)
0.019 (6)
0.8
(39)
2
(62)
100
(437)
140
(516)
230
(662)
300
(756)
0.019 (6)
0.8
(39)
2
(62)
100
(437)
140
(516)
230
(662)
300
(756)
0.022 (6)
0.8
(36)
2
(57)
100
(405)
140
(479)
200
(573)
300
(701)
0.022 (6)
0.8
(36)
2
(57)
100
(405)
140
(479)
200
(573)
250
(640)
0.022 (6)
0.8
(36)
2
(57)
100
(405)
140
(479)
200
(573)
250
(640)
Drive Train Information
Number of Motors In Drive Train
Drive Motor Power, kW (hp)
1111111
2.3 (3)
3.7 (5)
(7.5)
Balance Detection
Vibration Switch Installed
STD STD STD STD STD STD STD
Electrical Heating (Optional)
Total Electrical Heating Capacity, kW
Number of Electrical Heating Elements
Electrical Heating Element Size, kW
21.5@240V
21.5@480V
6 – 240V 6 – 480V
32.2@240V
21.5@480V
9 – 240V 6 – 480V
32.2@240V
21.5@480V
9 – 240V 6 – 480V
3333Not
Electrical Connections (Non-electric Heated Models)
Table 1 (continued)
6
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
5.6
5.6
(7.5)
32.2@240V
21.5@480V
9 – 240V 6 – 480V
7.5
(10)
Not
Applicable
Not
Applicable
Applicable
5.6
(7.5)
Not
Applicable
Not
Applicable
Not
Applicable
11.2 (15)
Not
Applicable
Not
Applicable
Not
Applicable
C002882
Installation/Operation Supplement
Table 1 (continued)
Specifications 40H 60H 80H 100H 125H 140H 175H
Max. Circuit Breaker Size (200-240V, 3P)
Max. Circuit Breaker Size (380-480V, 3P)
All specifications are subject to change without notification.
15 15 20 20 30 30 Not
15 15 15 15 15 15 20
Tab le 1
Applicable
C002882
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
7
Installation/Operation Supplement
Medium Speed Models
Specifications 40M 60M 80M 100M 140M
Overall Dimensions
Overall Width, mm (in.)
Overall Height, mm (in.)
Overall Depth, mm (in.)
Weight and Shipping Information
Net Weight, kg (lbs.)
Domestic Shipping Weight, kg (lbs.)
Domestic Shipping Volume, m3 (ft.3)
Wash Cylinder Information
Cylinder Diameter, mm (in.)
Cylinder Depth, mm (in.)
Cylinder Volume, l (ft.3)
Perforation Size, mm (in.)
Cylinder Capacity 1:10 Fill Ratio, kg (lbs.)
813
(32)
1448
(57)
1158
(45.6)
499
(110)
536
(1180)
1.78 (63)
686
(27)
483
(19)
178.3 (6.3)
4.83
(0.19)
17.8
(39.3)
Models
(34.5)
1590
(62.6)
1213
(47.8)
(1175)
(1250)
2.18
(76.9)
(31)
(22)
271.7 (9.6)
4.83
(0.19)
27.2 (60)
876
533
567
787
559
1080
(42.5)
1778
(70)
1306
(51.4)
740
(1630)
785
(1730)
3.11
(110)
940
(37)
533
(21)
370.7
(13.1)
4.83
(0.19)
37
(81.6)
1080
(42.5)
1778
(70)
1433
(56.4)
804
(1770)
849
(1870)
3.45
(122)
940
(37)
660
(26)
458.5
(16.2)
4.83
(0.19)
45.9
(101)
1276
(50.3)
1958
(77.1)
1502
(59.1)
1044
(2300)
1112
(2450)
4.73
(167)
1092
(43)
686
(27)
642.4
(22.7)
4.83
(0.19)
64.3
(141.7)
Door Opening Information
Door Opening Size, mm (in.)
Height of Door Bottom Above Floor, mm (in.)
381
(15)
648
(25.5)
Drain System
Overflow Size, mm (in.)
Drain Outlet Size, mm (in.)
Number of Drain Outlets, (std/opt)
38.1
(1.5)
76.2 (3)
1/2 1/2 1/2 1/2 1/2
Water Inlet
Connection Size
Number of Inlets, (std/opt)
All specifications are subject to change without notification.
8
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
3/4 NPT 3/4 NPT 3/4 NPT 3/4 NPT 1-1/4 NPT
2/3 2/3 2/3 2/3 2/3
432
(17)
730.3
(28.8)
38.1
(1.5)
76.2 (3)
Table 2 (continued)
508
(20)
751.8
(29.6)
38.1
(1.5)
76.2 (3)
508
(20)
765
(30.1)
38.1
(1.5)
76.2 (3)
622
(24.5)
871.2
(34.3)
76.2 (3)
76.2 (3)
C002882
Specifications 40M 60M 80M 100M 140M
Chemical Supply System
Number of Dry Chemical compartments, (std/opt)
Number of Liquid Supply Connections, (std/opt)
Liquid Supply Connection Size
1/51/51/51/51/5
6/12 6/12 6/12 6/12 6/12
1/2 NPT1/2 NPT1/2 NPT1/2 NPT1/2 NPT
Drive Train Information
Number of Motors In Drive Train
Drive Motor Power, kW (hp)
2.3 (3)
Cylinder Speeds/Centrifugal Force Data
Low Wash Speed, G-Force (RPM)
Was h S peed , G-Force (RPM)
Balance Speed, G-Force (RPM)
Extract Speed, G-Force (RPM)
Maximum SmartSpin Speed, G-Force (RPM)
0.014 (6)
0.8
(46)
(72)
100
(511)
150
(625)
Installation/Operation Supplement
Table 2 (continued)
Models
11111
2.3 (3)
0.016 (6)
0.8
(43)
2
2
(67)
100
(477)
150
(585)
3.7 (5)
0.019 (6)
0.8
(39)
2
(62)
100
(437)
150
(535)
3.7 (5)
0.019 (6)
0.8
(39)
2
(62)
100
(437)
150
(535)
5.6
(7.5)
0.022 (6)
0.8
(36)
2
(57)
100
(405)
152
(500)
Balance Detection
Vibration Switch Installed
STDSTDSTDSTDSTD
Electrical Heating (Optional)
Total Electrical Heating Capacity, kW
Number of Electrical Heating Elements
Electrical Heating Element Size, kW
21.5@240V
21.5@480V
6 – 240V 6 – 480V
3 3 3 3 Not Applicable
32.2@240V
21.5@480V
9 – 240V 6 – 480V
Electrical Connections (Non-electric Heated Models)
Max. Circuit Breaker Size (200-240V, 3P)
Max. Circuit Breaker Size (380-480V, 3P)
15 15 15 15 20
15 15 15 15 15
All specifications are subject to change without notification.
Tab le 2
32.2@240V
21.5@480V
9 – 240V 6 – 480V
32.2@240V
21.5@480V
9 – 240V 6 – 480V
Not Applicable
Not Applicable
C002882
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
9