Allen & Heath M-sq-slink User Manual

M-SQ-SLINK Fitting Note AP11565 Issue 1
SQ SLink Option Card
Fitting the card
1. Switch the system off.
2. Use a Torx T8 driver to remove the 2 screws securing the I/O Port
blank panel to the SQ mixer.
3. Slide the card into the slot and press it firmly into the mating
connector.
4. Refit the 2 screws to secure the card.
Software and firmware
Download and install the latest version of SQ firmware:
http://www.allen-heath.com
M-SQ-SLINK requires SQ firmware V1.3 or above.
Front panel
Link Status
Flashes to indicate
network activity
SLink port
Locking EtherCon port
Setting clock and patching signals
Use the SQ I/O screen to patch signals to or from the I/O Port.
Use the Setup / Audio / Audio Sync screen to select the clock source for the mixer. Typically, this is set to Internal, though can be switched to I/O Port if connecting directly to another desk i.e. when connecting to a dLive GigaACE option card or another SLink port.
There should only be one clock ‘master’ in a system. For more information on SQ setup and functions please
refer to the SQ Firmware Reference Guide available for download at www.allen-heath.com.
Different protocols
The built-in SLink port and the port on the SLink Option Card are independent from one another and automatically switch between 3 modes. Each port can be in either dSnake/ME, DX or GigaACE mode.
You cannot run two different protocols on the same port