Legacy PanelView Terminals to PanelView Plus 7 Terminals
Catalog Number Conversions
Top icPa ge
About This Publication1
Summary of Changes2
Application Migration2
Catalog Number Explanations3
Catalog Number Conversion Tables10
PanelView Standard 300 and 300 Micro Terminals Conversions10
PanelView Standard 550 Terminals Conversions11
PanelView Standard 600 Terminals Conversions15
PanelView Standard 900 Terminals Conversions19
PanelView Standard 1000 Terminals Conversions25
PanelView Standard 1400 Terminals Conversions31
PanelView Enhanced 1000e, 1200e, and 1400e Terminals Conversions33
Accessories34
Legacy Communication Support34
Adapter Kit Convers ion Table35
Additional Resources35
About This Publication
This publication provides information to help you convert legacy 2711 PanelView™ Standard terminals and
2711E PanelView Enhanced terminals to these new generation terminals:
• PanelView Plus 7 Standard terminals
• PanelView Plus 7 Performance terminals
Legacy PanelView Terminals to PanelView Plus 7 Terminals Catalog Number Conversions
Summary of Changes
This publication contains new and updated information as indicated in the following table.
Top icPag es
Updated the document with information about the PanelView Plus 7 Performance Series B
terminals.
Throughout
Application Migration
Human Machine Interface (HMI) applications for PanelView Plus 7 terminals are created by using FactoryTalk® View
Studio for Machine Edition software. You can import PanelView Standard and Enhanced/PanelBuilder™ 32 applications
into FactoryTalk View Studio as Machine Edition applications by using the Machine Edition Import Wizard. The
Import Wizard takes you through a series of steps, such as scaling to a new screen resolution size, and then converts
objects, text, tags, and communication configurations to ones that are available in Machine Edition software. See the
Migrating PanelView Standard Applications to PanelView Plus 7 Migration Guide, publication 2711P-AP006
Resolution Differences
.
What impact does the resolution have when you run a PanelView Standard or Enhanced terminal application on a
PanelView Plus 7 terminal?
• The PanelView Plus 7 terminals have greater resolution than the PanelView Standard or Enhanced terminals.
• If you do not resize the application, the application runs in the top-left of the terminal. This issue is true for
FactoryTalk View ME station platforms.
• If you do resize the application, you can go into each screen and adjust the position and layout of the objects. This
is especially useful when you convert from a normal screen to a wide screen.
If the terminal is set to allow desktop access and the shell type is set to open, these issues occur:
• The application does not resize to match the resolution of the screen.
• The application does not cover the screen. The Windows CE desktop is exposed, and can be activated by touch.
If the terminal is set to disallow desktop access and the shell type is set to close, these issues occur:
• The application does not resize to match the resolution of the screen.
• The application does not cover the screen. The FactoryTalk View ME station is exposed, and cannot be activated
by touch.
Application Migration for Communication
All PanelView Standard and Enhanced terminal applications that are set to serial communication must be changed to
Ethernet communication for PanelView Plus 7 terminals.
2Rockwell Automation Publication 2711P-AP005E-EN-P - March 2021
Legacy PanelView Terminals to PanelView Plus 7 Terminals Catalog Number Conversions
Catalog Number Explanations
This section provides a description of the catalog numbers for the standard and enhanced terminals.
PanelView 300 Monochrome Terminals
Cat. No.Input
2711-K3A2L1
2711-K3A5L1
2711-K3A5L1K
(1)
(1)
(1)(2)
Keypad3-in.Monochrome
Display
SizeType
CommunicationPower
DH-485
RS-232 (DH-485)
RS-232 (DH-485)
DC240 KB/170 KB
Memory
Nonvolatile/RAM
2711-K3A10L1DeviceNet® and RS-232
2711-K3A17L1
(1) Terminals with a DH-485 communication port require application uploads and downloads through the communication port. The RS-232 printer port is only for printing.
(2) K at the end of a catalog number means that the terminal is conformal-coated.
(3) This terminal does not have an RS-232 printer port. Use the communic ation port to download or upload application files.
(3)
RS-232 (DF1)
PanelView 300 Micro Terminals
(1)
Cat. No.
Input
2711-M3A18L1
Keypad3-in.Monochrome
2711-M3A19L1
(1) These terminals do not have an RS-232 printer port. Use the communication port to upload and download application files.
(1) Touch terminals with L1 at the end of the catalog number support only DC power. Keypad or keypad/touch terminals with L1 added to the catalog number indicate DC power; for example, 2711-
K5A10L1.
(2) L2 added to the catalog number of keypad or keypad/touch terminals indicate a stainless steel terminal with AC power; for example, 2711-K5A5L2.
(3) L3 added to the catalog number of keypad or keypad/touch terminals indicate a stainless steel terminal with DC power; for example, 2711-BFA10L3.
(4) Terminals with DH-485 communication require that you upload or download applications by using the communication port. The RS-232 port on these terminals is only for printing.
Rockwell Automation Publication 2711P-AP005E-EN-P - March 20213
Legacy PanelView Terminals to PanelView Plus 7 Terminals Catalog Number Conversions
(1) Touch terminals with L1 at the end of the catalog number support only DC power. Keypad or keypad/touch terminals with L1 added to the catalog number indicate DC power; for example, 2711-
K6C3L1.
(2) Terminals with DH-485 communication require that you upload or download applications by using the communication port. The RS-232 port on these terminals is only for printing.
4Rockwell Automation Publication 2711P-AP005E-EN-P - March 2021
PanelView Standard 900 Terminals
Legacy PanelView Terminals to PanelView Plus 7 Terminals Catalog Number Conversions
(1) Terminals with L1 added to the catalog number indicate DC power; for example, 2711-K9C10L1 or 2711-T9A10L1.
(2) Terminals with DH-485 communication require that you upload or download applications by using the communication port. The RS-232 port on these terminals is only for printing.
AC
Rockwell Automation Publication 2711P-AP005E-EN-P - March 20215
Legacy PanelView Terminals to PanelView Plus 7 Terminals Catalog Number Conversions
(1) Terminals with L1 added to the catalog number indicate DC power; for example, 2711-K10C3L1 or 2711-K10G3L1.
(2) Terminals with DH-485 communication require that you upload or download applications by using the communication port. The RS -232 port on these terminals is only for printing.
(1) Terminals with DH-485 communication require that you upload or download applications by using the communication port. The RS-232 port on these terminals is only for printing.
6Rockwell Automation Publication 2711P-AP005E-EN-P - March 2021
Legacy PanelView Terminals to PanelView Plus 7 Terminals Catalog Number Conversions
PanelView Enhanced Terminals
Catalog Number Product Description
2711E-T10C6 1000e Touch Screen TerminalColor display, clip mount, NEMA 4X
2711E-K10C6 1000e Keypad Terminal Color display, clip mount, NEMA 4X
(1) The standard models support the Windows CE version 6.0 operating system with an FTP server, VNC client ser ver, ActiveX controls, and PDF reader.
PanelView Plus 7 Standard Terminals Product Selections without Extended Features
(1)
Cat. No.
Touch Screen SizeType
2711P-T4W21D8S
2711P-T4W22D8S–Yes
2711P-T6C21D8S
2711P-T6C22D8S–Yes
2711P-T7C21D8S
2711P-T7C22D8S–Yes
2711P-T9W21D8S
2711P-T9W22D8S–Yes
2711P-T10C21D8S
2711P-T10C22D8S–Yes
2711P-T12W21D8S
2711P-T12W22D8S–Yes
2711P-T15C21D8S
2711P-T15C22D8S–Yes
(1) Add -B to the end of a catalog number to order a terminal without the Allen-Bradley® logo and product identification; for example, 2711P-T9W21D8 S-B.
Display
4.3-in.
5.7-in.
6.5-in.
9.0-in.
10.4-in.
12.1-in.
15.0-in.
WQVGA
TFT color
VGA
TFT color
VGA
TFT color
WVGA
TFT color
SVGA
TFT color
WXGA
TFT color
XGA
TFT color
Aspect
Ratio
Pixels
(W x H)
16:9480 x 272
4:3640 x 480
4:3640 x 480
5:3800 x 480
4:3800 x 600
16:101280 x 800
4:31024 x 768
Input
Power
DC
Operating
System
Model-Option
Ethernet PortsMemory
SingleDLRRAMNonvolatile
Yes–
Yes–
Yes–
Yes–
Yes–
Yes–
Yes–
512 MB
(1)
B = No brand
label
512 MB
nonvolatile
memory
(approx. 80 MB
free user
memory)
8Rockwell Automation Publication 2711P-AP005E-EN-P - March 2021
Legacy PanelView Terminals to PanelView Plus 7 Terminals Catalog Number Conversions
This section shows the catalog number breakdown for the PanelView Plus 7 Performance terminals.
PanelView Plus 7 Performance Terminal Product Selections with Extended Features
(1) (2)
Cat. No.
TouchKey and Touch SizeTypeDLRAC or DCRAMNonvolatile
2711P-T7C22D9P2711P-B7C22D9P
2711P-T7C22A9P2711P-B7C22A9PAC
2711P-T9W22D9P–
2711P-T9W22A9P–AC
2711P-T10C22D9P2711P-B10C22D9P
2711P-T10C22A9P2711P-B10C22A9PAC
2711P-T12W22D9P–
2711P-T12W22A9P–AC
2711P-T15C22D9P2711P-B15C22D9P
2711P-T15C22A9P2711P-B15C22A9PAC
2711P-T19C22D9P–
2711P-T19C22A9P–AC
(1) Add -B to the end of a catalog number to order a terminal without the Allen-Bradley® logo and product identification; for example, 2711P-T 9W22D9P-B.
(2) Conformal coating is available f or the DC power, touch models (and the 15-in. DC power combination keypad/touch model) of the PanelVi ew Plus 7 Perform ance fa mily. To order a terminal that is
conformal-coated, add K to the end of a DC-power catalog number; for example, 2711P-T7C22D9PK.
(3) Available on Series A terminals only.
6.5-in.
9-in. (wide)
10.4-in.
12.1-in. (wide)
15-in.
19-in.
DisplayEthernet Power Memory
VGA
TFT Color
WVGA
TFT Color
SVGA
TFT Color
WXGA
TFT Color
XGA
TFT Color
SXGA
TFT Color
Operating
System
9 =
Window s CE
(Series A)
or
Windows 10 IoT
Core (Series B)
Yes
Model-Option
P =Performance -
DC
(3)
DC
(3)
DC
(3)
DC
(3)
Series A
512 MB
Series B
4 GB
DC
(3)
DC
(3)
B = No brand
identity
K = Conform alcoated
Series A
512 MB
nonvolatile
memor
(approx. 80 MB
free user
memory)
Series B
19.87 GB
nonvolatile
memory
(approx. 3GB
free user
memory)
Rockwell Automation Publication 2711P-AP005E-EN-P - March 20219
Legacy PanelView Terminals to PanelView Plus 7 Terminals Catalog Number Conversions
Catalog Number Conversion Tables
Tables in this section provide a direct catalog number conversion for your PanelView Standard terminal to a compatible
PanelView Plus 7 terminal.
PanelView Standard 300 and 300 Micro Terminals Conversions
See the tables in this section for primary and secondary conversions for PanelView Standard 300 and 300 Micro
terminals.
PanelView Standard 300 and 300 Micro Terminals Primary Replacement Options
PanelView Standard TerminalsPanelView Plus 7 Terminals – Primary Replacement Options
Panel Cutout
Dimensions
Model Cat. No.
Height
mm (in.)
Width
mm (in.)
2711-K3A5L1K
2711-K3A10L1DH-485
300
300
Micro
2711-K3A17L1
2711-K3A2L1
2711-K3A5L1
2711-M3A18L1
2711-M3A19L1
197
(7.76)
133
(5.23)
140
(5.53)
111
(4.38)
Display
Resolution
128 x 64
Comm.Cat. No.
RS-232
(DF1)
RS-232
(D-485)
RS-232
(D-485)
DeviceNet
and RS-232
RS-232
(DF1)
2711P-T4W21D8S
Panel Cutout
Dimensions
Height
mm (in.)
92
117
(3.62)
(4.61)
Width
Display
Resolution
mm (in.)
480 x 272
Comm.
One
Ethernet
port
Adapter
Plate
Cat. No.
N/A
Notes
PanelView Plus 7 Standard 4-in.
terminal benefits:
Higher resolution
Application limits:
• Max. screen count: 25
• Max. alarm messages: 200
• Max. number of controllers: 1
Communication = Ethernet
(dual Ethe rnet ports are
available) .
Operator input = only touch.
Power i nput = on ly DC.
Confor mal coat = No.
PanelView Standard 300 and 300 Micro Terminals Secondary Replacement Options
PanelView Standard TerminalsPanelView Plus 7 Terminals – Secondary Replacement Options
Panel Cutout
Dimensions
Model Cat. No.
Height
mm (in.)
Width
mm (in.)
2711-K3A5L1K
2711-K3A10L1DH-485
300
300
Micro
2711-K3A17L1
2711-K3A2L1
2711-K3A5L1
2711-M3A18L1
2711-M3A19L1
197
(7.76)
133
(5.23)
140
(5.53)
111
(4.38)
Display
Resolution
128 x 64
Comm.Cat. No.
RS-232
(DF1)
RS-232
(D-485)
RS-232
(D-485)
DeviceNet
and RS-232
RS-232
(DF1)
2711P-B7C22D9P
Panel Cutout
Dimensions
Height
142
(5.59)
Display
Width
237
(9.33)
Resolution
mm (in.)
640 x 480
mm (in.)
Comm.
Dual
Ethernet
ports
Adapter
Plate
Cat. No.
N/A
Notes
PanelView Plus 7 Performance
6.5-in. terminal benefits:
• Higher resolution
• DLR
Communication = Ethernet.
Operator input = keypad and
touch.
Power i nput = on ly DC.
Confor mal coat = No.
10Rockwell Automation Publication 2711P-AP005E-EN-P - March 2021
Legacy PanelView Terminals to PanelView Plus 7 Terminals Catalog Number Conversions
PanelView Standard 550 Terminals Conversions
See the tables in this section for primary and secondary conversions for PanelView Standard 550 terminals.
PanelView Standard 550 Terminals Primary Replacement Options
PanelView Standard TerminalsPanelView Plus 7 Terminals – Primary Replacement Options
Model Cat. No.
2711-K5A1
2711-K5A1L1
2711-K5A10
2711-K5A10L1
2711-K5A14
2711-K5A14L1
2711-K5A12
2711-K5A12L1
2711-K5A16
2711-K5A16L1
2711-K5A15
2711-K5A15L1
2711-K5A2
2711-K5A2L1
2711-K5A3
2711-K5A3L1
2711-K5A5
550
2711-K5A5L1
2711-K5A9
2711-K5A9L1
2711-K5A8
2711-K5A8L1
2711-K5A20
2711-K5A20L1
2711-B5A1
2711-B5A1L1
2711-B5A10
2711-B5A10L1
2711-B5A14
2711-B5A14L1
2711-B5A12
2711-B5A12L1
2711-B5A16
2711-B5A16L1
Panel Cutout
Dimensions
Height
mm (in.)
144
243
(5.67)
(9.57)
Width
mm (in.)
Display
Resolution
256 x 128
Comm.Cat. No.
Remote I/O
DeviceNet
RS-232
RS-232
(DF1)
Control Net
DH-485
2711P-T6C21D8S
RS-232
(DH-485)
DH+
EtherNet/IP
Remote I/O
DeviceNet
RS-232
RS-232
(DF1)
Panel Cut out
Dimensions
Height
mm (in.)
123
156
(4.84)
(6.14)
Width
Display
Resolution
mm (in.)
640 x 480
Comm.
One
Ethernet
port
Adapter
Plate
Cat. No.
N/A
Notes
PanelView Plus 7 Standard 6in. terminal benefits:
Higher resolution
Application limits:
• Max. screen count: 25
• Max. alarm messages: 200
• Max. number of controllers: 1
Communication = Ethernet
(dual Ethernet ports are
available).
Operator input = only touch.
Power input = only DC.
Confor mal coat = No.
Rockwell Automation Publication 2711P-AP005E-EN-P - March 202111