Allegro A3189LUA, A3189LU, A3189LLT, A3189EUA, A3189EU Datasheet

...
HALL-EFFECT LATCHES
FOR HIGH-TEMPERATURE OPERATION
These Hall-effect latches are extremely temperature-stable and stress­resistant sensors especially suited for operation over extended temperature ranges to +150°C. Superior high-temperature performance is made possible through a novel Schmitt trigger circuit that maintains operate and release point symmetry by compensating for temperature changes in the Hall ele­ment. Additionally, internal compensation provides magnetic switch points that become more sensitive with temperature, hence offsetting the usual degradation of the magnetic field with temperature. The symmetry capability makes these devices ideal for use in pulse-counting applications where duty cycle is an important parameter. The four basic devices (3185, 3187, 3188, and 3189) are identical except for magnetic switch points.
Each device includes on a single silicon chip a voltage regulator, qua­dratic Hall-voltage generator, temperature compensation circuit, signal amplifier, Schmitt trigger, and a buffered open-collector output to sink up to 25 mA. The on-board regulator permits operation with supply voltages of 3.8 to 24 volts.
The first character of the part number suffix determines the device operating temperature range. Suffix ‘E–’ is for -40°C to +85°C, and suffix ‘L–’ is for -40°C to +150°C. Three package styles provide a magnetically optimized package for most applications. Suffix ‘–LT’ is a miniature SOT­89/TO-243AA transistor package for surface-mount applications; suffix ‘–U’ is a three-lead plastic mini-SIP, while suffix ‘–UA’ is a three-lead ultra-mini­SIP.
Data Sheet
27609.2A
ABSOLUTE MAXIMUM RATINGS
at TA = +25°C
Supply Voltage, VCC............................ 30 V
Reverse Battery Voltage, V
RCC
........... -30 V
Magnetic Flux Density, B ........... Unlimited
Output OFF Voltage, V
OUT
.................. 30 V
Reverse Output Voltage, V
OUT
.......... -0.5 V
Continuous Output Current, I
OUT
..... 25 mA
Operating Temperature Range, T
A
Suffix ‘E–’ ................... -40°C to +85°C
Suffix ‘L–’ ................. -40°C to +150°C
Storage Temperature Range,
TS............................... -65°C to +170°C
FEATURES
Symmetrical Switch Points
Superior Temperature Stability
Operation From Unregulated Supply
Open-Collector 25 mA Output
Reverse Battery Protection
Activate With Small, Commercially Available Permanent Magnets
Solid-State Reliability
Small Size
Resistant to Physical Stress
Pinning is shown viewed from branded side.
Always order by complete part number: the prefix ‘A’ + the basic four-digit part number + a suffix to indicate operating temperature range + a suffix to indicate package style, e.g., A3185ELT .
3185
THRU
3189
Dwg. PH-003A
1
SUPPLY
V
CC
GROUND
32
OUTPUT
X
3185
THRU
3189
HALL-EFFECT LATCHES FOR HIGH-TEMPERATURE OPERATION
115 Northeast Cutoff, Box 15036 Worcester, Massachusetts 01615-0036 (508) 853-5000
ELECTRICAL CHARACTERISTICS over operating temperature range, at V
CC
= 12 V.
Limits
Characteristic Symbol Test Conditions Min. Typ. Max. Units
Supply Voltage V
CC
Operating 3.8 24 V
Output Saturation Voltage V
OUT(SAT)
I
OUT
= 20 mA, B > B
OP
175 400 mV
Output Leakage Current I
OFF
V
OUT
= 24 V, B < B
RP
0.05 5.0 µA
Supply Current I
CC
B < BRP (Output OFF) 4.75 8.0 mA
B > B
OP
(Output ON) 5.7 mA
Output Rise Time t
r
RL = 820 , CL = 20 pF 100 ns
Output Fall Time t
f
RL = 820 , CL = 20 pF 100 ns
MAGNETIC CHARACTERISTICS in gauss over operating supply voltage range.
Part Numbers*
A3185 A3187 A3188 A3189
Characteristic Min. Max. Min. Max. Min. Max. Min. Max.
B
OP
at TA = 25°C 170 270 50 150 100 180 50 230
over operating temp. range 140 300 50 175 80 200 50 250
B
RP
at TA = 25°C -270 -170 -150 -50 -180 -100 -230 -50
over operating temp. range -300 -140 -175 -50 -200 -80 -250 -50
B
hys
at TA = 25°C 340 540 100 300 200 360 100 460
over operating temp. range 280 600 100 350 160 400 100 500
FUNCTIONAL BLOCK DIAGRAM
NOTES: BOP = operate point (output turns ON); BRP = release point (output turns OFF); B
hys
= hysteresis (BOP - BRP). As used here, negative flux densities are defined as less than zero (algebraic convention). *Complete part number includes a suffix to identify operating temperature range (E or L) and package type ( LT, U, or UA).
V
CC
X
REG.
Dwg. FH-005-3
GROUND
OUTPUT
1
3
2
Copyright © 1995, 1999, Allegro MicroSystems, Inc.
3185
THRU
3189
HALL-EFFECT LATCHES
FOR HIGH-TEMPERATURE
OPERATION
TYPICAL OPERATING CHARACTERISTICS
A3185* SWITCH POINTS A3187* SWITCH POINTS
* Complete part number includes a suffix denoting operating temperature range (E or L) and package type (LT, U, or UA).
OUTPUT SATURATION VOLTAGE
SUPPLY CURRENT
SUPPLY CURRENT
OPERATE POINT
0 50 100
AMBIENT TEMPERATURE IN °C
-50
Dwg. GH-027
SWITCH POINT IN GAUSS
0
50
100
-50
-100
OPERATE POINT
RELEASE POINT
V = 12 V
CC
150
150
-150
-25 25 75 125
0 25 50 75
100
AMBIENT TEMPERATURE IN °C
-50
Dwg. GH-028
125
-25
V = 12 V
CC
B B
RP
SUPPLY CURRENT IN mA
7.0
6.0
5.0
4.0
B ≥ B
OP
150
0255075
100
300
0
AMBIENT TEMPERATURE IN °C
200
100
-50
Dwg. GH-029
SATURATION VOLTAGE IN mV
150
-25
125
I = 20 mA
V = 4.5–24 V
OUT
CC
10 15 20 25
SUPPLY VOLTAGE IN VOLTS
0
Dwg. GH-037
5
CHANGE IN OPERATE POINT IN GAUSS
-5.0
0
5.0
10
15
20
T = +25°C
A
0 50 100
AMBIENT TEMPERATURE IN °C
-50
Dwg. GH-026
SWITCH POINT IN GAUSS
0
100
200
-100
-200
OPERATE POINT
RELEASE POINT
V = 12 V
CC
150
300
-300
-25 25 75 125
10 15 20 25
SUPPLY VOLTAGE IN VOLTS
0
Dwg. GH-030
5
SUPPLY CURRENT IN mA
0
2.0
4.0
6.0
8.0
10
B B
OP
B B
RP
T = +25°C
A