Allegro A3058LU, A3058EU, A3056LU, A3056EU, A3046LU Datasheet

...
HALL EFFECT GEAR-TOOTH SENSORS
X X
V
CC
1
SUPPLY
Pinning is shown viewed from branded side.
ABSOLUTE MAXIMUM RATINGS
Supply Voltage, VCC. . . . . . . . . . . . . . 28 V
Reverse Battery Voltage,
V
. . . . . . . . . . . . . . . . . . . . . . -30 V
RCC
Magnetic Flux Density, B . . . . . Unlimited
Output OFF Voltage, V
Reverse Output Voltage, V
Output Current, I
Package Power Dissipation, P
Operating Temperature Range, T
Suffix “EU” . . . . . . . . . -40°C to +85°C
Suffix “LU” . . . . . . . . -40
Storage Temperature Range,
TS. . . . . . . . . . . . . . . -65°C to +170°C
OUT
. . . . . . . . . . . . 25 mA
OUT
32
GROUND
Dwg. PH-012
OUTPUT
. . . . . . . . . 28 V
. . . . . -0.5 V
OUT
. . 500 mW
D
A
°C to +150°C
3046, 3056, AND 3058
The A3046EU/LU, A3056EU/LU, and A3058EU/LU Hall effect gear-tooth sensors are monolithic integrated circuits that switch in response to differential magnetic fields created by ferrous targets. These devices are ideal for use in gear-tooth-based speed, position, and timing applications and operate down to zero rpm over a wide range of air gaps and temperatures. When combined with a back­biasing magnet and proper assembly techniques, devices can be configured to give 50% duty cycle or to switch on either leading, trailing, or both edges of a passing gear tooth or slot.
The six devices differ only in their magnetic switching values and operating temperature ranges. The low hysteresis of the A3046/56EU and A3046/56LU makes them perfectly suited for ABS (anti-lock brake system) or speed sensing applications where maintaining large air gaps is important. The A3046EU/LU features improved switch point stability with temperature over the A3056EU/LU. The high hysteresis of the A3058EU and A3058LU, with their excellent temperature stability, makes them especially suited to ignition timing applications where switch-point accuracy (and latching requirements) is extremely important.
Continued next page...
BENEFITS
Senses Ferrous Targets Down to Zero RPM
Large Effective Air Gap
Wide Operating Temperature Range
Operation from Unregulated Supply
High-Speed Operation
Output Compatible With All Logic Families
Reverse Battery Protection
Solid-State Reliability
Resistant to Physical Stress
SELECTION GUIDE
Switching Hysteresis
15-90 G 150-250 G
Operating Temp. Range Device Type Number
-40°C to +85°C A3046EU A3058EU A3056EU
-40°C to +150°C A3046LU A3058LU A3056LU
Data Sheet
27612A†
3046, 3056, AND 3058
HALL EFFECT GEAR-TOOTH SENSORS –ZERO SPEED
All devices, when used with a back­biasing magnet, can be configured to turn ON or OFF with the leading or trailing edge of a gear tooth or slot. Changes in fields on the magnet face caused by a moving ferrous mass are sensed by two integrated Hall transducers and are differentially amplified by on-chip electronics. The on-chip temperature compensation and Schmitt trigger circuitry minimizes shifts in effective working air gaps and switch points over temperature making these devices ideal for use in ignition timing, anti-lock braking systems, and speed mea­surement systems in hostile automotive and industrial environments.
Each Hall effect digital Integrated circuit includes two quadratic Hall effect sensing elements, a voltage regulator, temperature compensating circuitry, low-level amplifier, Schmitt trigger, and an open-collector output driver. The on-board regulator permits operation with supply voltages of 4.5 to 24 volts. The output stage can switch up to 20 mA at conservatively specified repetition rates to 20 kHz and is compatible with bipolar and MOS logic circuits.
FUNCTIONAL BLOCK DIAGRAM
SUPPLY
1
REG
OUTPUT
3
+
X X
Both magnetic characteristics are available in a choice of two operat-
ing temperature ranges. Suffix EU devices have an operating range of
-40°C to +85°C while suffix LU devices feature an operating range of
-40°C to +150°C. All devices are packaged in a 3-pin plastic SIP.
2
GROUND
Dwg. FH-010
ELECTRICAL CHARACTERISTICS at VCC = 8 V, over operating temperature range.
Limits
Characteristic Symbol Test Conditions Min. Typ. Max. Units
Supply Voltage V
Power-Up State 3058* only, Output is OFF
Output Saturation Voltage V
Output Leakage Current I
Supply Current I
Output Rise time t
Output Fall time t
CC
OUT(SAT)
OFF
CC
r
f
Operating 4.5 24 V
V
= 0 4.5 V, B < B
CC
I
= 20 mA, B > B
OUT
VCC = V
VCC = 24 V, B < B
RL = 820 , CL = 20 pF 100 ns
RL = 820 , CL = 20 pF 100 ns
115 Northeast Cutoff, Box 15036 Worcester, Massachusetts 01615-0036 (508) 853-5000
Copyright © 1989, 1995 Allegro MicroSystems, Inc.
= 24 V, B < B
OUT
RP
OP
OP
RP
135 400 mV
5.0 µA
7.2 14 mA
3046, 3056, AND 3058
HALL EFFECT
GEAR-TOOTH SENSORS
–ZERO SPEED
MAGNETIC CHARACTERISTICS in gauss at VCC = 8 V.
Part Numbers*
3046 3056 3058
Characteristic Test Conditions Min. Typ. Max. Min. Typ. Max. Min. Typ. Max.
Operate Point, B
OP
Output Switches OFF to ON, 150 150 250
TA = +25°C
Release Point, B
RP
Output Switches ON to OFF, -150 -150 -250
TA = +25°C
Hysteresis, B
hys
Change in Trip Point, ±50 ±75 ±50
B
or ∆B
OP
RP
NOTES: 1. Magnetic switch points are specified as the
difference in magnetic fields at the two Hall elements.
2. As used here, negative flux densities are defined as less than zero (algebraic conven­tion).
BOP-BRP, TA = +25°C 15 50 90 15 50 90 150 200 250
Over operating temperature range,
Ref. B
or BRP at TA = +25°C
OP
TYPICAL OPERATING CHARACTERISTICS
200
V = 8 V
CC
I = 20 mA
OUT
180
3. Typical values are at TA = +25°C. * Complete part number includes the prefix
160
‘A’ and a suffix to identify operating tempera­ture range and package style. See selection guide.
10
9
8
7
SUPPLY CURRENT IN mA
6
B > B
B < B
T = +25°C
A
OP
RP
140
SATURATION VOLTAGE IN mV
120
100
-50
11
10
9
8
7
SUPPLY CURRENT IN mA
6
0
AMBIENT TEMPERATURE IN °C
50 100 150
Dwg. GH-033
V = 24 V
CC
B > B
OP
B < B
RP
5
0
510152025
SUPPLY VOLTAGE IN VOLTS
www.allegromicro.com
Dwg. GH-031
5
-50
0
AMBIENT TEMPERATURE IN °C
50 100 150
Dwg. GH-032
Loading...
+ 5 hidden pages