Alarm Lock PDL3300 User Manual

PDL3300
345 Bayview Avenue
Amityville, New York 11701
For Sales and Repairs 1-800-ALA-LOCK
For Technical Service 1-800-645-9440
© ALARM LOCK 2004
Alarm Lock’s new PDL3300 Series digital lock is a cylindrical-based door lock that includes a "Door Ajar" feature, allow­ing an audible warning should the door remain open beyond a programmed period of time. In addition, a relay can be activated by a Door Ajar event, allowing the activation of an external device, such as a siren or a camera. The PDL3300 includes an HID compatible ProxCard
The PDL3300 is based upon the existing PDL3000 lock design (see WI1021 for more information), with modifications to accommodate new features:
1. Door Ajar Sensor White Wires: Monitor the status of a Door Sensor (a normally closed magnetic reed switch that when closed indicates a closed door, and when open indicates an open door). Door Sensor is enabled at the factory, and can be disabled by physically disconnecting the two white wires from the door switch and program­ming
;64:
than approximately 25 seconds, the lock will silence and go back to sleep. However, the lock will wake up upon a door closure in order to log the closure event (see "New Door Events" below).
2. New Door Events: When the monitored door remains open after a pre-programmed length of time, a "Door Ajar" event is logged. When the door is closed again, a "Door Closure" event is logged as well.
3. New Programming Functions: New functions can be enabled via the keypad, as follows:
Audible Sounder on Door Ajar: When the magnetic reed switch is held open beyond the "Door Ajar Trip Time" (default is 20 seconds), the sounder will activate.
Activate Relay on Door Ajar
Time" (default is 20 seconds), the relay will close for 2 seconds. (Specifications for relay)
Door Ajar Time Duration: Specifies the amount of time for an open magnetic reed switch to trigger a Door Ajar event, and, if programmed, activating the sounder or relay.
One Time Only for Group 3 Users
When enabled, specifies that all User Codes assigned to Group 3 will be permitted access for one time only. Once access is granted, the User is then disabled, disallowing future access to the secured door. Unless re­enabled by entering Program Mode, the user must present a valid proximity card and/or enter a valid User Code (at the keypad) to allow access. Re-enable the User in one of three ways: (a) In Program Mode, en-
;4;
ter disabled); or (c) Re-enable each user individually via a schedule. See the PDL3000 Programming Instruc-
tions (WI1021) for more information.
, "Disable Door Ajar Monitoring". If the door is held open (in the "Door Ajar" state) for more
[User Number] :; (b) Download original program via DL-Windows (with Users enabled or
WITH "DOOR AJAR" FEATURE
®
reader.
: When the magnetic reed switch is held open beyond the "Door Ajar Trip
CYLINDRICAL LOCK
WI1293 9/04
: (Implemented in all new Trilogy T3 locks starting with ETDL V36c).
DL-Windows Compatibility
The new features were added to DL-Windows, all located on the Features screen, Options tab:
Enable/Disable Door Ajar Monitoring
Audible Sounder on Door Ajar
Activate Relay on Door Ajar
Door Ajar Time Duration
One Time Only for Group 3 Users
New Programming Functions
Door Ajar Features
Audible Sounder on Door Ajar
Factory Default = ON. When the magnetic reed switch is held open beyond the "Door Ajar Time Duration" (default is 20 sec­onds), the sounder will activate. program
the DL/PDL3000 Programming Instructions for more information.
;67;000:
Enable Sounder
Delete ALL Features added by Function 67
"Use Sounder on Door Ajar" is active by default; to disable,
NOTE:
to delete ALL features added by Function 67. See
; 6 7 ; 3 5 :
;67;000:
Activate Relay on Door Ajar
Factory Default = OFF. When the magnetic reed switch is held open beyond the "Door Ajar Time Duration" (default is 20 sec­onds), the relay will close for 2 seconds.
;67;000:
gram
the DL/PDL3000 Programming Instructions for more information.
Enable Relay
To disable "Activate Relay on Door Ajar", pro-
NOTE:
to delete ALL features added by Function 67. See
; 6 7 ; 1 2 :
Delete ALL Features added by Function 67
;67;000:
Door Ajar Time Duration
Factory Default = 20 seconds Valid entries are 2 – 250 seconds
Specifies the amount of time for an open magnetic reed switch to trigger a Door Ajar event, and, if pro­grammed, activating the sounder or relay.
Door Ajar Trip Time (sec.)
;68; [ _ _ _ ] :
(Number of seconds)
One Time Only for Group 3 Users
Specifies that all User Codes assigned to Group 3 will be permitted access for one time only. Once access is granted, the User (and therefore their User Code and/or Proximity Card/Fob) is then disabled, disallowing future access to the protected door. To add a User to Group 3, see the PDL3000 Program­ming Instructions.
features added by Function 67. See the DL/PDL3000 Programming Instructions for more information.
Programming
NOTE:
;67;000:
will delete ALL
Enable One Time Only for Group 3 Users
Enable User
(By User Number)
Delete ALL Features added by Function 67
;67;24:
;4; [ _ _ _ _ ] :
;67;000:
(User Number)
Loading...