Features a real-time clock/calendar that automatically adjusts for Daylight
Saving Time and allows for automated programming of events. Features
three methods of programming:
(1) All features can be programmed manually through the keypad;
(2) You can transfer programming instructions directly from your lap-
top or desktop PC using DL Windows software and a special AL-PCI cable; and
(3) data can be transferred from your PC to your DL lock via the AL
DTM handheld Data Transfer Module.
In addition, data can be retrieved from the lock in one of three ways (1)
through an infrared printer; (2) directly from the lock to the PC; or (3)
through an AL-DTM to your PC.
Table of Contents
DL2800 Lock Features .........................................3
Product Communication Examples ..................... 12
2
------- AUDIT LOG -------
09/23/05 13:06:35 Fri
13:01:59 001 PROGRAM 56
13:01:29 001 PROGRAM 57
13:00:53 001 ENTRY
13:00:26 013 ENTRY
13:00:03 012 ENTRY
12:56:27 001 PROGRAM 2
12:56:27 001 PROGRAM 40
12:56:04 001 PROGRAM 39
12:55:00 NEW CLCK TIME
12:01:39 OLD CLCK TIME
12:00:45 RAM TEST:PASS
12:00:45 POWER UP
------------------------End of Audit Log
DL2800 Lock Features
User Features
• 200 Users
• Pre-defined Administration User Levels including Master, Manager and Supervisor
User Codes (see page 9)
• User Code Lengths from 3-6 digits
• Service Code (“One-Time-Only” Code) (see page 8)
• User Lockout Mode (see page 15, Function 6)
• Users Assignable to 4 Groups (see page 17)
Lock Features
• Metal Key Override
• Keypad Lockout (see page 22, Functions 60-61)
• Non-Volatile (Fixed) Memory
• Real-Time Clock adjustable to within 1 second (see page 19, Functions 43-44)
• Visual and Audible Keypad Feedback (see page 11)
• Battery Status Monitor (see page 10-11)
Scheduling
• 150 Scheduled Events (see page 24)
• Automated Unlock/Lock
• Enable/Disable Users (see page 14, Function 3)
• Enable/Disable Groups (see page 16)
• Four "Quick Schedules" (contains 4 most common schedules) (see page 25)
• Real-time clock and calendar (see page 18)
• Programmable Timeout Functions (see page 17)
User Access Methods
• Keypad Entered User Codes (see page 14)
• Metal Key Override
Keypad and Computer Programming
• All programming may be performed manually from the keypad, or from a PC using
Alarm Lock's DL-Windows Software (see page 8. "What is DL-Windows?")
Audit Trail
• 1000 Event Capacity
• Entries Logged with Time and Date
• Critical Programming Events Logged
• Printable using the AL-IR1 Hand-Held Printer (see page 21, Function 55)
• Transferable using Alarm Lock's DL-Windows software (see page 21, Function 58)
• Transferable to AL-DTM
AL-DTM Data Transfer Module
• Use Alarm Lock’s AL-DTM to easily transfer program data between locks and a PC
running DL-WINDOWS software. Easily transfer Audit Trail from multiple locks and
then view or print each Audit Trail from a computer.
3
Supported Products
Data Transfer Module (AL-DTM)
An AL-DTM can be used to transfer Lock Programs (and other data) between DL-Windows and locks. When
computers cannot be transported or when electrical power is not available, the hand-held AL-DTM device acts as
a go-between--it allows the transfer of lock data from the computer (through the AL-DTM) and to the lock, or in
reverse (from the lock through the AL-DTM back to the computer). Use of the older AL-DTM model 1 is not
recommended. Note: The latest model, the AL-DTM-III, is supported in DL-Windows version 3.5.1 or
later.
Infrared Printer (AL-IR1)
An AL-IR1 printer is used to print Audit Trails and User Code lists without the need for a PC. Its infrared
reader means no cable connection to the lock is needed.
AL-PCI Cable
An ALARM LOCK AL-PCI cable is required to communicate between your computer’s RS-232 serial communications port (COM 1-4) and the AL-DTM or lock. One end of the AL-PCI cable is designed to be used
on a 9-pin serial Com Port. If your computer has a 25-pin Com Port only, a 25-pin to 9-pin adapter must be
used. The other end of the AL-PCI cable features a 2-pin banana plug connector which is polarity sensitive-
-the TAB (marked “GND”) side must be plugged into the lock’s black (left) terminal.
Double-ended Mini Banana Plug Connector
After you create the program in DL-Windows and transfer the program from your computer to an AL-DTM,
transfer the program from the AL-DTM to the lock(s) via a double-ended mini banana plug.
DB9 to DB9 Serial Cable
Enroll User Codes into DL-Windows, then transfer this new User Code data from the computer to the AL-PRE via this 9-pin DB9 to DB9 serial cable. Once the data is in the AL-PRE, you can transfer the data to
the lock via the double-ended mini banana plug (see above), thus avoiding the need to use an AL-PCI
cable for this process.
USB to RS-232 Cable
If your computer does not have a serial COM port (DB-9 male) available, you can plug your
AL-PCI2 cable into a special USB to RS-232 cable. Order part PCI-USB for the USB to RS232 cable only, or ALPCI2-U for both the USB to RS-232 cable and an AL-PCI2 cable).
4
Lock Design Overview
Why Use Software inside a Lock?
With ordinary door locks, the need to make physical copies of metal keys and distributing them can be a huge organizational and
financial task -- and what will you do if someone causes a security breach by losing their key?
The answer lies in the advantage of software. Software (also called "firmware") is not "hard" or "fixed" like hardware--software is
flexible and changeable to your needs. Software can be programmed (and re-programmed again and again) to suit your changing
requirements. Rather than copy and distribute metal keys, distribute User Codes -- and delete them from the Lock Program software when required. (A User Code is the software equivalent of a metal key--it is a series of numbers the User enters into the
keypad to unlock the lock).
Preparing to Program your Lock
The DL2800 lock keypad contains 12 buttons, numbers 1 through 9 plus zero, a star button (:) and a special "AL" button
(;). You can either use these 12 buttons to program your lock--or--you can program your lock using a computer program
called DL-Windows. DL-Windows is not needed--but it makes programming faster and easier. This guide will show you how to
program your lock manually (using only the keypad), without DL-Windows. (For more information about DL-Windows, see User
Guide OI237).
Programming your lock begins after you unpack it from the box -- there is a specific procedure outlined on page 6 ("Quick Start") in
which you "wake up" the lock to prepare it for use. To begin programming the lock, you must first enter something called "Program
Mode".
What is Program Mode?
The software inside the lock has two "modes": "Normal Mode" and "Program Mode". When you want to make changes to the lock
program (add User Codes for example), enter "Program Mode". When you finish programming and wish to put the lock into use,
exit "Program Mode" to enter "Normal Mode".
You enter Program Mode using the keypad--by pressing the Master Code of the lock that was set at the factory. The Master Code
is basically a secret passcode that allows you to enter Program Mode. But since all locks are identical and leave the factory with
the same Master Code, the factory Master Code is therefore not very secret--and should be changed to your own personal Master
Code. This is to ensure that only YOU can enter Program Mode and make changes to the lock programming.
Once the new Master Code is set , then you can continue with the Quick Start procedure and set the weekday, date and time. Af-
ter this, you can start entering User Codes for people to use. All changes to the lock are organized by their "Function Number".
Want to change the date? Use Function Number 38. Want to add a User Code? Use Function Number 2. There are 99 Functions in total, some that you will use often, and others that you may never need.
Notice that when you program your lock, programming tends to follow a
(2) Press ; followed by the Function Number (3) Press ; and enter data (4) Press : to end (5) Exit Program
Mode.
Turn to page 7 and learn about the special terminology used with your lock. The Quick Start procedure (on page 6) will
help you get up and running quickly.
consistent 5-step pattern: (1) Enter Program Mode
Tri-Color Status LED
Infrared LED (for Printer)
PC / AL-DTM Interface
Keypad
Special "AL" (;) Key
"STAR" (:) Key
Lever
Lock Operation
• While the lever may be rotated at any time, the latch will not be
engaged to unlock the lock unless a valid User Code has been
entered into the keypad.
• When a valid User Code is entered, the lock will unlock imme-
diately and remain unlocked for 5 seconds (this 5 second
"Pass Time" can be changed--see page 20, functions 51-53).
5
Quick Start
First Time Start Up
IMPORTANT: Failure to follow this exact procedure can result in erratic lock behavior.
The DL2800 lock uses five (5) AA-size 1.5 volt alkaline batteries. Remove the back cover, install batteries into the battery
pack. Connect the battery pack plugs and the lock will beep 3 times. To load the default program press any key within 5 seconds, the lock will beep slowly while the default values are loaded and beep rapidly upon completion.
Enter Program Mode and Change Factory Master Code
1. Press the default Master Code: 1 2 3 4 5 6.
2. Wait for the green light and press ; until multiple beeps are heard. You are now in Program Mode.
(Note: The lock will beep every 6 seconds as a reminder that you are in Program Mode).
3. Enter a new personal 6-digit Master Code number by pressing the following keys:
; 1 ; [
(For example, if you want your new Master Code to be “664433”. Press:
; 1 ; 664433 ; 664433 :).
Now that the Master Code has been changed, there is no need to change it again (unless you want to). Since you
are still in Program Mode, you can now proceed directly below and program various functions. Note: Programming any Function, such as setting the time, follows a consistent 5-step pattern: (1) Enter Program Mode (2)
Press ; [Function #]
(3) Press ; and enter data (4) Press : to end (5) Exit Program Mode (if desired).
(For example, John Smith is designated as User 21. You want him to use the User Code of “232323” to unlock the
lock. Program the lock by pressing: ; 2 ; 21 ; 232323 :).
3. Repeat step 2 for each new User.
Exit Program Mode
Hold Down any key for 3 seconds. Program Mode exit is confirmed by several beeps. You are now in "normal" operation.
Re-enter Program Mode
If you wish to re-enter Program Mode, key-in your new 6-digit Master Code, and press ;.
You are now ready to mount and install your DL2800 series lock and give out your User Codes. Before installation, it is suggested you test and verify that all User Codes entered are active. Use the IR1 infrared printer (available separately) to print your
own audit logs and User Codes list.
new Master Code] ; [new Master Code] : (the second set of digits must be exactly the same).
number of weekday] :. (Use 1= Sunday, 7 = Saturday).
MMDDYY] :.
HHMM] :. (Use 24-hour military (HHMM) format, where PM adds 12 hours).
User Number] ; [User Code] :.
6
Terminology Used in this Manual
The Lock Program
A Lock Program is stored within the lock's circuitry and contains
the instructions that the lock uses to perform its various functions. You can use the keypad to change the Lock Program,
and you can also use DL-Windows (defined below) to create a
Lock Program on your computer, and then transfer and store
the Lock Program within the lock circuitry.
The Lock Program consists of 4 areas: User Codes, Func-
tions, Time Zones, and Schedules, all defined below:
User Codes
Also called "User Access Codes", "Passcode numbers" or "PIN
Number Codes", a User Code is a 3 to 6 digit number the User
enters into the keypad (using the keypad buttons) to unlock the
lock. The DL2800 can store hundreds of different User Codes
in its Lock Program, and the Lock Program is stored in the lock
circuitry awaiting the Users to key in their individual User
Codes. Each User Code is associated with a User Number,
defined below.
The User
A User is defined as a person who is authorized to operate or
perform programming changes to the Lock Program. The
DL2800 lock can hold hundreds of "Users" (in the form of User Codes) in its Lock Program, and each User possesses a predefined level of authority--a Programming Level--as to their
ability to use or make changes to the Lock Program. Some
Users may be able to unlock the lock only; others may also be
able to make changes to the Lock Program.
User Numbers
(User Number = Location Number = User Location = Slot)
User Numbers are used and are significant within each individual lock only. The DL2800 Series locks can hold up to 200
User Numbers in its Lock Program, which can be thought of as
simply a numbered list from 1 through 200 (with number 1 at
the top). Each User Number can be programmed with a User
Code. In addition, each User Number possesses a pre-defined
level of authority--a Programming Level--as to the User's ability make changes to the Lock Program. Where a User is lo-
cated in this list--their User Location--is a commonly used description of their User Number. Because of their similarities,
the terms User Number, User Location and Location Number
can be used interchangeably. In some DL-Windows screens,
the word "Slot" is also used. They all mean the same thing.
Since User Numbers are fixed, knowing the location of a User
Number will specify its associated Programming Level, and will
in turn indicate a User’s programming abilities (if any). For example, User Number 1 is always the Master, who can perform
all programming tasks. Lower down the list, User Number 189
is a Basic User and although this User is assigned a User Code
to unlock the lock, because they are a "Basic User" they are
unable to perform any programming changes.
Programming Functions
Your lock is designed to support many different features that
can be programmed to suit each installation. Using the keypad
(or DL-Windows software), authorized Users can activate these
features and make other changes to the Lock Program. Each
of these features is called a Programming Function. In addition, each Function possesses its own pre-defined Program-
ming Level to access that Function. Each User must possess
a Programming Level EQUAL to the Programming Level
assigned to the Function in order to access that Function.
When programming via the keypad, see page 13 for a list of all
Functions 1 through 99. For example, you can enable Daylight
Saving Time via Function number 41. Each Programming
Function is described on pages 14-26.
Programming Levels
The Programming Level defines which Programming Functions
a User is allowed to perform. Each User Number is associated
with a defined level of ability--a Programming Level--as to
which Functions the assigned User can access. The highest
level--Master--allows access to ALL Functions.
In addition, each Function (see pages 14-26) has its own fixed
Programming Level.
A User must possess a Programming Level equal to the
Programming Level of the Function in order to access that
Function.
Programming Levels can have a value of "1", "2", "3", "4" or
"M". Note: Having a Programming Level of "3" does not allow
access to Functions with Programming Levels of 1, 2 or 4.
The following defaults apply when adding User Codes via Programming Function 2:
Master: The highest level User, and always associated with
User Number 1 and its Master Code only. Master is always
enabled and can program ALL Functions. (Abbreviated as
the Programming Level = "M").
Manager: Always associated with User Numbers 2-6. Can
program all Functions except Functions relating to lock configuration. (Abbreviated as Programming Level = "1", "2" or
"3").
Supervisor: Always associated with User Numbers 7-11. Can
only program Functions relating to certain day to day operations. (Abbreviated as Programming Level = "1" or "2").
Basic Users: Always associated with User Numbers 12
through 200. When adding User Codes for Basic Users via
Programming Function 2, Programming Levels are not assigned by default. Note: Programming Levels for Users 2200 can be assigned via Function 8. For Users 299 and
300, see below for entries.
See chart on page 9 for a summary.
Groups
It is convenient for large numbers of similar Users to be
grouped together. By placing Users into Groups (assigning
them to a specific range of User Numbers), large numbers of
Users can be controlled all at once rather than individually-saving time and effort. Groups are controlled via schedules,
and a typical example involves enabling or disabling a Group at
a certain time. The DL2800 lock has factory-programmed De-fault Group Associations that are specified in the table on page
9. For example, if you wish to add a User to Group 1, assign
this User to a User Number between 51 and 100. These Default Group Associations can be changed if needed to allow
Groups larger than the default quantity of 50 (by using keypad
Function 35). (See page 25 for some Group function examples).
7
Terminology Used in this Manual (cont'd)
TimeZones
Events (recorded lock activities) can be programmed to occur
at specific times. It is these times (for example, “every Tuesday at 5PM”) that are referred to as TimeZones. TimeZones
can be created manually through the keypad. In DL-Windows,
you can create TimeZones and link events to them.
Schedules
Program your lock to maintain a schedule in which certain
events occur automatically. For example, you can program the
lock to allow Groups 1 Users access ONLY during specific
business hours. With another example, you can program the
lock to UNLOCK at 9AM, LOCK at noon for lunch, UNLOCK at
1PM, and LOCK again at 5PM--every weekday. As you can
see, many different combinations of Schedules can be created
to suit your installation. First you create TimeZones (see
above), then create events and link them to your TimeZones.
Users 299 & 300
User Codes added to locations 299 and 300 have special abilities, as follows:
User 299: AL-DTM Code
This is the only User Code that will initiate data transfer with
the AL-DTM--and without allowing the lock to unlock (the User
Code for User Number 299 does NOT allow access). An ALPCI cable and an AL-DTM (pre-programmed by a computer
with DL-Windows) are required.
User 300: One-Time Only Service Code
This is a one-time-only service User Code designed to be
used for access by temporary workers. When enabled, entering User Code 300 into the keypad will allow the DL2800 lock
to unlock only once (re-entering User Code 300 will not operate). User Number 300 is enabled by Function 9. (Note:
Function 9 can only be enabled by Users with a Program Authority Level of 2).
User Code 300 can also be used for guard tour duties.
DL-Windows
DL-Windows is a computer program that allows you to program
your ALARM LOCK Security Lock. You do not need DLWindows to program your lock, but it makes programming
much faster and easier. With DL-Windows, you can quickly
create Lock Programs, add multiple Users, retrieve event logs,
and create Schedules. The benefit of DL-Windows is that it
allows you to set up all lock programming in advance (on your
computer), and then later transfer the information into the installed locks at your convenience.
Conventions Used in this Manual
2
Enabling/Disabling Users (By User Number)
User Number must be between 2 and 200. (DL2800 Series locks all ow up to 200 Users).
Function
Description
Programming
Information
Function
Number
NOTE: Will Enable/Disable users even if the user is assoc iated with an enabled group.
3. Disable User
4. Enable User
Function
Name
; 3 ; [ _ _ _ ] :
; 4 ; [ _ _ _ ] :
Programming Key
Sequence
.
General Program Mode Information
If a wrong key is pressed during code entry, hold any key continuously until the error sound is heard (7 short beeps), this will clear the entry. Re-enter the key
sequence again.
All program sequences are followed by the : key; 2 short beeps indicate a successful program sequence.
8
Required Programming Level
This is the Programming Level required to access the Function.
Possible Programming Levels are "1", "2", "3", "4" and "M", where"M" = Master Code.
The Programming Level of theUser must be equalto the Func-tion that is to be accessed.
Programming Levels
The Programming Level defines which Programming Functions a User is allowed to perform. Each User Number is associated with a defined level of ability--a Programming Level-
-as to which Functions the assigned User can access. The
highest level--Master--allows access to ALL Functions.
In addition, each Function (see pages 14-26) has its own fixed
Programming Level.
A User must possess a Programming Level equal to the
Programming Level of the Function in order to access that
Function.
Programming Levels can have a value of "1", "2", "3", "4" or
"M". Note: Having a Programming Level of "3" does not allow
access to Functions with Programming Levels of 1, 2 or 4.
The following defaults apply when adding User Codes via Programming Function 2:
Master: The highest level User, and always associated with
User Number 1 and its Master Code only. Master is always enabled and can program ALL Functions.
Users programmed with Function 2 will default to a Group
Association and a Programming Level Ability as follows:
USER TYPE USER NUMBER DEFAULT
(Abbreviated as the Programming Level = "M").
Manager: Always associated with User Numbers 2-6. Can
program all Functions except Functions relating to lock
configuration. (Abbreviated as Programming Level = "1",
"2" or "3").
Supervisor: Always associated with User Numbers 7-11.
Can only program Functions relating to certain day to day
operations. (Abbreviated as Programming Level = "1" or
"2").
Basic Users: Always associated with User Numbers 12
through 200. When adding User Codes for Basic Users via
Programming Function 2, Programming Levels are not assigned by default. Note: Programming Levels for Users 2200 can be assigned via Function 8.
DEFAULT
GROUP ASSOCIATION
PROGRAMMING LEVEL
Master Code 1 none M, 4, 3, 2, 1
Manager Codes 2 - 6 none 3, 2, 1
Supervisor 7 - 11 none 2, 1
Basic User Codes 12 - 50 none none
Basic User Codes Group 1 51 - 100 1 none
Basic User Codes Group 2 101 - 150 2 none
Basic User Codes Group 3 151 - 200 3 none
Initiate DTM (Non-Pass Code) 299 none none
Service Code 300 none none
NOTE:
User 299 is a Non-Pass Code. This is the only code that will initiate data transfer with the AL-DTM.
9
Wiring, Power Up & Battery Replacement
WIRING
See the Installation Manual for more information.
Batteries:
Use only 1.5 volt Duracell Alkaline size-AA batteries.
With average use, batteries last about 5 years.
Terminals (Standard Models Only)
Red & Black Wires (Operation without Batteries) -
Optional 7.5 VDC Voltage for operation without batteries.
White & White Wires (Remote Input) - Wire a Nor-
mally Open Contact to Terminals 3 & 4. Momentarily
close to allow person to pass through door. NOTE: Re-
mote Input is enabled from the factory.
PC Interface - Connect to Serial Port on Computer us-
ing A-PCI interface cable.
Wire Leads for DL2800WP Models
Note: On all WP (waterproof) models, be sure to use
provided dielectric grease on the battery connector to
ensure a waterproof connection.
WHITE
Remote
Release
WHITE
RED
BLACK
Battery
Connector
RED
BLACK
Motor
Connector
POWER DOWN
--RETAIN LOCK PROGRAMMING
• When applying power to the lock for the first time,
stop here and follow the procedure outlined in "QUICK
START" on page 6.
• When power is re-applied to a lock that was already
operational and you wish to retain the lock programming (such as when transferring the lock from one door
to another door), proceed as follows:
1. Unplug battery pack.
2. Press any key to ensure the lock's capacitor is fully discharged.
3. Re-connect battery pack (lock will give 3 short beeps).
4. Do not press any keys for 10 seconds.
5. After the 10 second period the LED will flash red 6
times and 6 beeps will sound.
The lock is now ready for use. Program is loaded from
non-volatile (fixed) memory. Note: Audit Trail and Clock
Settings are lost. Re-set the clock using functions 38, 39
and 40.
ERASE ALL PROGRAMMING
• The "out of box" factory default will be loaded.
1. Unplug battery pack.
2. Press any key to ensure lock's capacitor is fully discharged.
3. Re-connect battery pack (lock will give 3 short beeps).
4. Press any key within 5 sec after hearing the 3 beeps.
5. A series of beeps will be heard.
All settings and programming have been erased and the
lock is now ready for use. Note: All lock programming can
also be erased (without need to disconnect the batteries)
by entering Function 99.
BATTERY REPLACEMENT
• When applying power to the lock for the first time,
stop here and follow the procedure outlined in "QUICK
START" on page 6.
You will know the batteries are weak when a valid
code is entered and the following occurs: the light
amber LED lights and the sounder sounds for 4 seconds. The DL2800 lock uses five (5) AA-size 1.5 volt
alkaline batteries. Always replace weak batteries as
soon as possible.
CAUTION: Do not press any keys while batteries are
disconnected or you may erase the real-time clock
settings. Pressing any key will remove the voltage that
is required to keep the system clock and Audit Trail in
memory.
1. At the back of the lock, remove the screw at the bottom
of the lock housing and remove the cover.
2. Pull out the battery pack and quickly replace all 5 batteries - within 2 minutes.
3. If you do not hear the 3 beeps when power is reapplied, all programming and settings have been retained, and the lock is ready for use. Go to step 5.
4. If you do hear 3 beeps when power is re-applied, do not press any keys for 15 seconds. After the 15 second period, the LED will flash red 6 times and 6 beeps
will sound. Reset the clock using functions 38, 39 and
40.
5. Replace the cover and tighten the screw.
10
LED and Sounder Indicators
The DL Series locks provide visual and audible keypad feedback. With a fully charged battery, the LED and sounder feedback
is as follows:
ACTIVITY LED SOUNDER COMMENTS
Keypress 1 RED Flash 1 Beep Normal Operation
Access Granted or Remote Input 2 GREEN Flashes 2 Beeps For Remote Input, wire a normally
open contact to these two white
wires. Momentarily close to
unlock. See page 10 for more in-
formation.
Valid Code 1 Momentary GREEN
Flash
Invalid Code 6 RED Flashes 6 Beeps Re-enter User Code
Successful Program Entry 1+2 GREEN Flashes 1+2 Beeps When in Program Mode
Unsuccessful Program Entry 7 RED Flashes 7 Beeps When in Program Mode
Enter Program Mode 2 YELLOW & 1 GREEN
LED Flash
Exit Program Mode 1 RED, 2 GREEN,
1 RED Flashes
Valid but Disabled Code 1 RED, 1 GREEN, 4
RED Flashes
Low Battery upon User Code En-
try or upon closing of Remote Re-
lease switch
User Code Entered YELLOW Flash Sequence of 7
Button Press Continuous Series
YELLOW Flash during
key presses
1 long, 5 short
Steady 4-Second
Beeps Repeated 4
2 Groups of 5
Beeps
Code exists in memory, but dis-
Beeps
LED and sounder indications occur
Tone
Times
of Beeps
only when a valid code is entered.
See page 10 before changing bat-
Non-fatal memory or clock error
has been detected. Under this
condition, unexpected operation is
possible. Remove power and restart. Do not mistake the low bat-
tery indication as a memory or
System Fault. Ensure batteries
abled
teries
clock error
are fresh
11