Alarm Lock DL1200, DL1300, PDL1300 Installation Instruction

345 Bayview Avenue
Amityville, New York 11701
For Sales and Repairs 1-800-ALA-LOCK
For Technical Service 1-800-645-9440
Publicly traded on NASDAQ Symbol: NSSC
© ALARM LOCK 2007
DL1200 - DL1300 - PDL1300
NARROW STILE ACCESS LOCKS
ADDENDUM
WI1626 6/07
DESCRIPTION
This addendum is intended to ensure that the face of the interface cylinder is parallel with the surface of the door. Use this addendum with the "DL1200 - DL1300 - PDL1300 Narrow Stile Mounting and Installation Instructions" WI1458, pages 4-5, steps 5-5e:
PROCEDURE
Locate the heading entitled "Insert the Inter­face Cylinder" on page 4 (step 5). After per-
forming step 5e (installing the latch face plate on page 5), the following additional step is rec­ommended before installing the lock in step 6:
5f. Verify the face of the interface cylinder
("HW1299") is positioned parallel to the surface of the door.
With a straight edge flush against the sur-
face of the door as shown in the image be­low, place a small ruler on the right face of the interface cylinder to measure the dis­tance between the face of the interface cyl­inder and the surface of the door (the right "gap"). See Fig. 7c below.
Fig. 7c: Measure right "gap": Place a small ruler against the right
Interface
Cylinder
(HW1299)
Straight
Edge
side of the interface cylinder.
Right
"Gap"
Door
5g. Measure the left "gap" with the ruler on the
left face of the interface cylinder, as shown in Fig 7d, below:
Door
Interface Cylinder
(HW1299)
Left
"Gap"
Straight
Edge
Fig. 7d: Measure left "gap": Place a small ruler against the left side of
the interface cylinder.
The difference between the right and the
left "gap" distances must not exceed
1/32".
If face of the lock body is not parallel to the
surface of the door and the difference be­tween the left and right "gap" measure­ments exceeds 1/32", adjust the position of the Adams Rite® lock body until the face of the interface cylinder is parallel with the face of the door.
Loading...