345 Bayview Avenue
Amityville, New York 11701
For Sales and Repairs 1-800-ALA-LOCK
For Technical Service 1-800-645-9440
Publicly traded on NASDAQ Symbol: NSSC
© ALARM LOCK 2007
DL1200 - DL1300 - PDL1300
NARROW STILE ACCESS LOCKS
ADDENDUM
WI1626 6/07
DESCRIPTION
This addendum is intended to ensure that the
face of the interface cylinder is parallel with the
surface of the door. Use this addendum with
the "DL1200 - DL1300 - PDL1300 Narrow Stile
Mounting and Installation Instructions"
WI1458, pages 4-5, steps 5-5e:
PROCEDURE
Locate the heading entitled "Insert the Interface Cylinder" on page 4 (step 5). After per-
forming step 5e (installing the latch face plate
on page 5), the following additional step is recommended before installing the lock in step 6:
5f. Verify the face of the interface cylinder
("HW1299") is positioned parallel to the
surface of the door.
With a straight edge flush against the sur-
face of the door as shown in the image below, place a small ruler on the right face of
the interface cylinder to measure the distance between the face of the interface cylinder and the surface of the door (the right
"gap"). See Fig. 7c below.
Fig. 7c: Measure right "gap": Place a small ruler against the right
Interface
Cylinder
(HW1299)
Straight
Edge
side of the interface cylinder.
Right
"Gap"
Door
5g. Measure the left "gap" with the ruler on the
left face of the interface cylinder, as shown
in Fig 7d, below:
Door
Interface
Cylinder
(HW1299)
Left
"Gap"
Straight
Edge
Fig. 7d: Measure left "gap": Place a small ruler against the left side of
the interface cylinder.
The difference between the right and the
left "gap" distances must not exceed
1/32".
If face of the lock body is not parallel to the
surface of the door and the difference between the left and right "gap" measurements exceeds 1/32", adjust the position of
the Adams Rite® lock body until the face of
the interface cylinder is parallel with the face
of the door.