788 MONITORING FUNCTION INSTRUCTIONS
345 Bayview Avenue
Amityville, New York 11701
For Sales and Repairs 1-800-ALA-LOCK
For Technical Service 1-800-645-9440
Publicly traded on NASDAQ Symbol: NSSC
© ALARM LOCK 2004
MODEL 250 / 700 SERIES
P5401 12/04
The 788 monitoring function consists of a reed switch in our 730 keeper and an activating magnet in the lock's deadbolt. The 730 keeper has a pair of flying leads that provide normally closed dry contacts when the door is closed and the deadbolt is locked.
INSTALLATION
Follow the normal instructions for mounting the keeper with the following exception: Drill a 1/4" hole into the hollow metal door frame for the keepers flying leads to run through.
WIRING
OPERATION
When the door is closed and the deadbolt locked, the monitor will report a secure condition. Unlocking the deadbolt by depressing the pushbar (causing an alarm) or using a key will cause a break in the loop to the re­mote monitor. The monitor will simultaneously turn on the buzzer and light the lamp associated with that door. The tone may be reset at the monitor at once in order to continue monitoring other locks. The lamp may be reset only after the deadbolt is projected by the key.
MODEL 700
MODEL 250