Alarm Controls ZA-8N Specsheet

EIGHT ZONE ANNUNCIATOR
FOR ALL MONITORING APPLICATIONS
INDEPENDENT ZONE ANNUNCIATION WITH ZONE STATUS INDICATION
EIGHT RED LEDS INDICATE ZONE STATUS
SELECTABLE NORMALLY-OPEN, NORMALLY-CLOSED, SUPERVISED LOOPS
MEMORY FOR EACH ZONE WITH INDIVIDUAL ZONE OUTPUTS
INDIVIDUAL ZONE BYPASS SWITCHES WITH BYPASS DISABLE FEATURE
REMOTE ZONE ANNUNCIATION CAPABILITY
ADJUSTABLE DOOR AJAR TIMER
OPERATES ON 12 VOLTS AC OR DC
MODEL ZA-8N
ALARM CONTROLS CORPORATION
DEER PARK, NEW YORK
11729
OUTSTANDING FEATURES
ALARM CONTROLS CORPORATION
“QUALITY SECURITY EQUIPMENT SINCE 1971”
19 BRANDYWINE DRIVE, P.O. BOX 280, DEER PARK, NEW YORK
1 800 645-5538 631 586-4220 FAX 631 586-6500
EMAIL: INFO@ALARMCONTROLS.COM WWW.ALARMCONTROLS.COM
SPECIFICATIONS
VOLTAGE INPUT: 12 VOLTS AC, USE 20 VA TRANSFORMER, 12 VOLTS DC, USE 1 AMP SUPPLY
MAXIMUM CURRENT: 140 MILLIAMPERES
ZONE OUTPUT CURRENT: 100 MILLIAMPERES PER ZONE
REMOTE OUTPUT CURRENT: 80 MILLIAMPERES
LOOPS: NORMALLY-OPEN, NORMALLY-CLOSED, SUPERVISED WITH 10K RESISTOR (SUPPLIED)
LOOP LENGTH: 1000 FEET TOTAL
DOOR AJAR TIME RANGE: ONE SECOND TO FIVE MINUTES
REMOTE ANNUNCIATOR OUTPUT: LIMITED TO TWO MODEL ZP-8AN REMOTE PLATES
REMOTE ANNUNCIATOR: MODEL ZP-8AN, EIGHT RED LEDS MOUNTED ON SINGLE GANG PLATE
WITH ZONE RESET AND BUZZER
CABINET SIZE: 10” W x 7” H x 2” D
ZONE OUTPUTS
THE ZONE OUTPUTS
ARE LIMITED TO
100 MA / ZONE CAN DRIVE STROBE LAMPS AND RELAYS
2 AMP POWER FUSE
REMOTE PLATE CONNECTOR
USE TO CONNECT ZP-8AN
REMOTE PLATE TO ZA-8N
THIS OUTPUT IS LIMITED TO
TWO ZP-8AN REMOTE PLATES
LED ZONE INDICATORS
OFF ZONE NORMAL ON ZONE VIOLATED
FLASHING ZONE BYPASSED
BUZZER OFF - ON JUMPER
ZONE RESET
SWITCH
LOOP SELECTOR
SELECTS N/O, N/C
OR
SUPERVISED LOOPS
DOOR AJAR POT
ADJUSTS DOOR OPEN TIME FROM 1 SECOND
TO 5 MINUTES
DOOR AJAR TIMER
JUMPER
JUMPER TURNS TIMER
ON OR OFF
MODEL ZP-8AN
REMOTE PLATE
MODEL ZA-8N
ALARM CONTROLS CORPORATION
19 BRANDYWINE DRIVE, DEER PARK, NY 11729
800 645-5538 WWW.ALARMCONTROLS.COM
MODEL ZA-8N
EIGHT ZONE ANNUNCIATOR
LED ZONE
INDICATORS
OFF ZONE NORMAL ON ZONE VIOLATED
FLASHING ZONE
BYPASSED
DOOR AJAR
TIMER JUMPER
TO ACTIVATE TIMER
MOVE JUMPER TO
ON POSITION
LOOP SELECTOR
SWITCH
SELECTS N/O, N/C
OR
SUPERVISED LOOPS
2 AMP
POWER FUSE
REPLACE WITH
2 AMPERE
SLOW BLOW FUSE
P/N MDL-2
ZONE BYPASS
SWITCHES
SHUNTS
INDIVIDUAL
ZONES
ZONE RESET
SWITCH
RESETS ZONES
THAT HAVE BEEN
VOILATED
DOOR AJAR POT
ADJUSTS DOOR
OPEN TIME FROM
ONE SECOND TO
FIVE MINUTES
ZONE OUTPUTS
THE ZONE OUTPUTS ARE
LIMITED TO 100 MA. / ZONE
CAN DRIVE STROBE LAMPS
AND RELAYS
COMMON RELAY
OUTPUT
S.P.D.T. CONTACTS
RATED 12A@28VDC OR
120 VAC
REMOTE PLATE CONNECTOR
USE TO CONNECT ZP-8AN
REMOTE PLATE TO ZA-8N
THIS OUTPUT IS LIMITED TO
TWO ZP-8AN REMOTE PLATES
BUZZER OFF - ON JUMPER
TO DISABLE BUZZER MOVE
JUMPER FROM ON TO OFF
POSITION
IMPORTANT
THE ZA-8N HAS EFFECTIVE LIGHTNING PROTECTION ONLY WHEN GROUNDED
ACCORDING TO THE FOLLOWING INSTRUCTIONS:
CONNECT EG TERMINAL TO A COLD WATER PIPE
WITH NOT LESS THAN 18GA. SOLID WIRE OR TWO
CONDUCTOR 18 GA.STRANDED WIRE.
DO NOT GROUND TO A GAS PIPE OR THE
BUILDINGS ELECTRICAL GROUND!
ZP-8AN REMOTE ANNUNCIATOR
THE ZA-8AN IS A SINGLE GANG STAINLESS STEEL
WALLPLATE WITH EIGHT RED LEDS, REMOTE ZONE
RESET BUTTON AND AUDIBLE BUZZER
THE ZP-8AN CONNECTS TO THE REMOTE PLATE
CONNECTOR AND DISPLAYS ZONE STATUS
INSTALLATION INSTRUCTIONS
MODEL ZA-8N
EIGHT ZONE ANNUNCIATOR
SPECIFICATIONS
VOLTAGE INPUT: 12 VOLTS AC, USE 20 VA TRANSFORMER, 12 VOLTS DC, USE 1 AMP. SUPPLY MAXIMUM CURRENT: 140 MILLIAMPERES ZONE OUTPUT CURRENT: 100 MILLIAMPERES PER ZONE REMOTE OUTPUT CURRENT: 80 MILLIAMPERES LOOPS: NORMALLY-OPEN, NORMALLY-CLOSED, SUPERVISED WITH 10K RESISTOR (SUPPLIED) LOOP LENGTH: 1000 FEET TOTAL EACH ZONE LOOP DOOR AJAR TIMER RANGE: ONE SECOND TO FIVE MINUTES REMOTE ANNUNCIATOR OUTPUT: LIMITED TO TWO MODEL ZP-8AN REMOTE PLATES REMOTE ANNUNCIATOR: MODEL ZP-8AN, EIGHT RED LEDS MOUNTED ON SINGLE GANG WALLPLATE
WITH ZONE RESET AND BUZZER
10 K
RES.
10 K
RES.
10 K
RES.
10 K
RES.
10 K
RES.
10 K
RES.
10 K
RES.
10 K
RES.
NORMALLY-OPEN LOOPS
NORMALLY-CLOSED LOOPS
SUPERVISED LOOPS
DISABLE BYPASS FEATURE
TO DISABLE ZONE BYPASSING CONNECT A S.P.S.T. SWITCH OR JUMPER TO TERMINALS 2 AND 19
FOR TECHNICAL ASSISTANCE CALL 800 645-5538
SINGLE GANG STAINLESS STEEL PLATE
EIGHT RED LEDS
MOMENTARY ACTION RESET SWITCH
ALARM CONTROLS CORPORATION
19 BRANDYWINE DRIVE DEER PARK, NY 11729
1 631 586-4220 1 800 645-5538
WWW.ALARMCONTROLS.COM EMAIL INFO@ALARMCONTROLS.COM
MODEL ZP-18AN
FOR USE WITH MODEL ZA-8N
MODEL ZP-8A REMOTE PLATE ALLOWS THE REMOTE
DISPLAY OF ZONE ANNUNCIATOR STATUS AND
THE CAPABILITY OF REMOTE RESET
ALARM CONTROLS CORPORATION
DEER PARK, NY 11729
800 645-5538
ZP-18AN WIRING INSTRUCTIONS
THE ZP-18AN REMOTE ANNUNCIATOR PLATE PLUGS INTO A MALE CONNECTOR LABELED REMOTE PLATE
ON THE
ZA-8N ZONE ANNUNCIATOR.
CUT THE 12 COLORED LEADS 4” FROM THE CONNECTOR.
CONNECT ADDITIONAL FIELD WIRES TO THE ZP-18A AND THE ZA-8N AS REQUIRED. BE SURE THAT THE COLORS OF THE FIELD WIRES MATCH THE CONNECTIONS ON BOTH ENDS.
PLUG THE FEMALE CONNECTOR FROM THE ZP-18AN INTO THE CONNECTOR ON THE ZA-18AN.
THE BROWN WIRE ON THE CONNECTOR MUST BE ON THE LEFT!