Alarm Controls ZA-8N Specsheet

EIGHT ZONE ANNUNCIATOR
FOR ALL MONITORING APPLICATIONS
INDEPENDENT ZONE ANNUNCIATION WITH ZONE STATUS INDICATION
EIGHT RED LEDS INDICATE ZONE STATUS
SELECTABLE NORMALLY-OPEN, NORMALLY-CLOSED, SUPERVISED LOOPS
MEMORY FOR EACH ZONE WITH INDIVIDUAL ZONE OUTPUTS
INDIVIDUAL ZONE BYPASS SWITCHES WITH BYPASS DISABLE FEATURE
REMOTE ZONE ANNUNCIATION CAPABILITY
ADJUSTABLE DOOR AJAR TIMER
OPERATES ON 12 VOLTS AC OR DC
MODEL ZA-8N
ALARM CONTROLS CORPORATION
DEER PARK, NEW YORK
11729
OUTSTANDING FEATURES
ALARM CONTROLS CORPORATION
“QUALITY SECURITY EQUIPMENT SINCE 1971”
19 BRANDYWINE DRIVE, P.O. BOX 280, DEER PARK, NEW YORK
1 800 645-5538 631 586-4220 FAX 631 586-6500
EMAIL: INFO@ALARMCONTROLS.COM WWW.ALARMCONTROLS.COM
SPECIFICATIONS
VOLTAGE INPUT: 12 VOLTS AC, USE 20 VA TRANSFORMER, 12 VOLTS DC, USE 1 AMP SUPPLY
MAXIMUM CURRENT: 140 MILLIAMPERES
ZONE OUTPUT CURRENT: 100 MILLIAMPERES PER ZONE
REMOTE OUTPUT CURRENT: 80 MILLIAMPERES
LOOPS: NORMALLY-OPEN, NORMALLY-CLOSED, SUPERVISED WITH 10K RESISTOR (SUPPLIED)
LOOP LENGTH: 1000 FEET TOTAL
DOOR AJAR TIME RANGE: ONE SECOND TO FIVE MINUTES
REMOTE ANNUNCIATOR OUTPUT: LIMITED TO TWO MODEL ZP-8AN REMOTE PLATES
REMOTE ANNUNCIATOR: MODEL ZP-8AN, EIGHT RED LEDS MOUNTED ON SINGLE GANG PLATE
WITH ZONE RESET AND BUZZER
CABINET SIZE: 10” W x 7” H x 2” D
ZONE OUTPUTS
THE ZONE OUTPUTS
ARE LIMITED TO
100 MA / ZONE CAN DRIVE STROBE LAMPS AND RELAYS
2 AMP POWER FUSE
REMOTE PLATE CONNECTOR
USE TO CONNECT ZP-8AN
REMOTE PLATE TO ZA-8N
THIS OUTPUT IS LIMITED TO
TWO ZP-8AN REMOTE PLATES
LED ZONE INDICATORS
OFF ZONE NORMAL ON ZONE VIOLATED
FLASHING ZONE BYPASSED
BUZZER OFF - ON JUMPER
ZONE RESET
SWITCH
LOOP SELECTOR
SELECTS N/O, N/C
OR
SUPERVISED LOOPS
DOOR AJAR POT
ADJUSTS DOOR OPEN TIME FROM 1 SECOND
TO 5 MINUTES
DOOR AJAR TIMER
JUMPER
JUMPER TURNS TIMER
ON OR OFF
MODEL ZP-8AN
REMOTE PLATE
MODEL ZA-8N